CONCEPTS OF OPERATIONS FOR A US DOSIMETRY AND BIODOSIMETRY NETWORK.

Abstract:

:The USA must be prepared to provide a prompt, coordinated and integrated response for radiation dose and injury assessment for suspected radiation exposure, whether it involves isolated cases or mass casualties. Dose estimation for radiation accidents typically necessitates a multiple parameter diagnostics approach that includes clinical, biological and physical dosimetry to provide an early-phase radiation dose. A US Individual Dosimetry and Biodosimetry Network (US-IDBN) will increase surge capacity for civilian and military populations in a large-scale incident. The network's goal is to leverage available resources and provide an integrated biodosimetry capability, using multiple parameter diagnostics. Initial operations will be to expand an existing functional integration of two cytogenetic biodosimetry laboratories by developing Standard Operating Procedures, cross-training laboratorians, developing common calibration curves, supporting inter-comparison exercises and obtaining certification to process clinical samples. Integration with certified commercial laboratories will increase surge capacity to meet the needs of a mass-casualty incident.

journal_name

Radiat Prot Dosimetry

authors

Dainiak N,Albanese J,Kaushik M,Balajee AS,Romanyukha A,Sharp TJ,Blakely WF

doi

10.1093/rpd/ncy294

subject

Has Abstract

pub_date

2019-12-31 00:00:00

pages

130-138

issue

1

eissn

0144-8420

issn

1742-3406

pii

5307765

journal_volume

186

pub_type

杂志文章
  • MICRODOSIMETRIC SIMULATIONS OF CARBON IONS USING THE MONTE CARLO CODE FLUKA.

    abstract::Therapeutic carbon ion beams produce a complex and variable radiation field that changes along the penetration depth due to the high density of energy loss along the particle track together with the secondary particles produced by nuclear fragmentation reactions. An accurate physical characterisation of such complex m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx201

    authors: Chiriotti S,Conte V,Colautti P,Selva A,Mairani A

    更新日期:2018-08-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • A solid state microdosimeter based on a monolithic silicon telescope.

    abstract::A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl468

    authors: Agosteo S,Colautti P,Fazzi A,Moro D,Pola A

    更新日期:2006-01-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • A micro-gap, air-filled ionisation chamber as a detector for criticality accident dosimetry.

    abstract::A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct323

    authors: Murawski Ł,Zielczyński M,Golnik N,Gryziński MA

    更新日期:2014-10-01 00:00:00

  • Spatial distribution of indoor radon in Triveneto (Northern Italy): a geostatistical approach.

    abstract::The study of spatial distribution of the indoor radon has assumed in the last years a lot of interest. The geostatistical techniques turn out to be particularly promising. The present work presents the results of a study where around 4000 indoor radon data from Veneto, Friuli Venezia-Giulia and Alto Adige, collected d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp252

    authors: Bertolo A,Bigliotto C,Giovani C,Garavaglia M,Spinella M,Verdi L,Pegoretti S

    更新日期:2009-12-01 00:00:00

  • EXPERIMENTAL VALIDATION OF ALGORITHMS USED TO ESTIMATE EFFECTIVE DOSE DURING INTERVENTIONAL RADIOLOGY PROCEDURES.

    abstract::In IR procedures, in order to evaluate the effective dose, the importance of the double dosemeter has been recognised, one worn above and one under the apron. Over the last few decades several algorithms have been developed to combine the readings of the dosemeters, however currently there is no international consensu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz136

    authors: Negri P,Campi F,De Crescenzo S,Garlati L,Tambussi O

    更新日期:2019-12-31 00:00:00

  • Comparison of two JAERI phantoms and the problems discovered.

    abstract::During the course of an intercomparison exercise it was possible to compare two JAERI phantoms with each other by using a multi-energy photon emitting lung set (241Am/152Eu). One belonged to the IAEA (Vienna), the other belonged to the Human Monitoring Laboratory (Ottawa). The intercomparison of the phantoms showed th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006511

    authors: Kramer GH,Hauck BM

    更新日期:2001-01-01 00:00:00

  • Using simple mathematical functions to simulate pathological structures--input for digital mammography clinical trial.

    abstract::In this study a set of structures has been simulated to represent a range of clinically relevant breast cancer mammographic lesions including solid tumours and microcalcifications. All structures have been created using simple random-based mathematical functions and have been inserted into a subset of digital mammogra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch552

    authors: Ruschin M,Tingberg A,Båth M,Grahn A,Håkansson M,Hemdal B,Andersson I

    更新日期:2005-01-01 00:00:00

  • WHO's health risk assessment of ELF fields.

    abstract::The World Health Organization (WHO), the International Commission on Non-Ionizing Radiation Protection (ICNIRP), WHO's scientific collaborating centres (including the UK's National Radiological Protection Board (NRPB)) and over 50 participating Member States are participants of WHO's International EMF Project. As part...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006363

    authors: Repacholi MH

    更新日期:2003-01-01 00:00:00

  • Radiological emergency: Malaysian preparedness and response.

    abstract::Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr102

    authors: Yusof MA,Ali HM

    更新日期:2011-07-01 00:00:00

  • SPECTROSCOPIC STUDY ON POLY(ACRYLIC ACID-CO-ACRYLAMIDE)-GRAFT-POLYANILINE AS A RADIATION DOSIMETER FOR ALPHA PARTICLES.

    abstract::Poly(acrylate-co-acrylamide) was a synthesis by chemical oxidation polymerization of an aqueous binary mixture of acrylate/acrylamide (1:1 mole ratio) using ammonium persulphate as an initiator at 70°C under the nitrogen atmosphere. The obtained copolymer was introduced for grafting with polyaniline. The grafting proc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx124

    authors: Abd El-Mageed HR,Abd El-Salam HM,Eissa MF

    更新日期:2018-03-01 00:00:00

  • Determination of gamma-emitting radionuclides in the inter-tidal sediments off Balochistan (Pakistan) Coast, Arabian Sea.

    abstract::Natural radionuclide contents of 226Ra, 228Ra and (40)K were studied for inter-tidal sediments collected from selected locations off the745 km long Balochistan Coast using HPGe detector based gamma-spectrometry system. The sampling zone extends from the beaches of Sonmiani (near Karachi metropolis) through Jiwani (clo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl105

    authors: Akram M,Qureshi RM,Ahmad N,Solaija TJ

    更新日期:2007-01-01 00:00:00

  • Albedo Neutron Dosimetry in a Deep Geological Disposal Repository for High-Level Nuclear Waste.

    abstract::Albedo neutron dosemeter is the German official personal neutron dosemeter in mixed radiation fields where neutrons contribute to personal dose. In deep geological repositories for high-level nuclear waste, where neutrons can dominate the radiation field, it is of interest to investigate the performance of albedo neut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw147

    authors: Pang B,Becker F

    更新日期:2017-04-28 00:00:00

  • Simultaneous measurements of indoor radon, radon-thoron progeny and high-resolution gamma spectrometry in Greek dwellings.

    abstract::Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci366

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2006-01-01 00:00:00

  • Variation of radiocesium concentrations in cedar pollen in the Okutama area since the Fukushima Daiichi Nuclear Power Plant accident.

    abstract::Due to releases of radionuclides in the Fukushima Daiichi Nuclear Power Plant accident, radiocesium ((134)Cs and (137)Cs) has been incorporated into large varieties of plant species and soil types. There is a possibility that radiocesium taken into plants is being diffused by pollen. Radiocesium concentrations in ceda...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv248

    authors: Tsuruoka H,Inoue K,Sakano Y,Hamada M,Shimizu H,Fukushi M

    更新日期:2015-11-01 00:00:00

  • Study of the transfer of 137Cs from fodder to cow milk in the region around Narora Atomic Power Station NPP Site, India.

    abstract::Site-specific transfer coefficient from feed to cow's milk, for (137)Cs in the villages around Narora, a nuclear power station site in India, determined over a period of 17 y, is presented in this paper. In the transport model for the prediction of the concentration of (137)Cs in milk, the transfer coefficient from fe...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct058

    authors: Kumar D,Kumar A,Sharma AK,Singh B,Ravi PM,Sarkar PK

    更新日期:2013-09-01 00:00:00

  • Simulation of 125I induced DNA strand breaks in a CAP-DNA complex.

    abstract::The E. coli catabolite gene activator protein (CAP)-DNA complex with 125I located at the position of the H5 atom of the cytosine near the centre was incorporated into the PARTRAC track structure code. DNA strand breaks due to irradiation were calculated by track structure and radical attack simulations; strand breaks ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006738

    authors: Li W,Friedland W,Jacob P,Paretzke HG,Panyutin I,Neumann RD

    更新日期:2002-01-01 00:00:00

  • Modelling of nuclear power plant decommissioning financing.

    abstract::Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv333

    authors: Bemš J,Knápek J,Králík T,Hejhal M,Kubančák J,Vašíček J

    更新日期:2015-06-01 00:00:00

  • A minimally invasive method to evaluate 131I kinetics in blood.

    abstract::The dose limiting factor for 131I therapy in patients with thyroid cancer is myelotoxicity, thus an accurate determination of radioiodine activity in the red marrow is of paramount importance. The reference method for red marrow dosimetry in radiometabolic therapy is based on the measurement of radioiodine kinetics, p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch041

    authors: Traino AC,Di Martino F,Boni G,Mariani G,Lazzeri M

    更新日期:2004-01-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures.

    abstract::A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of ph...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch468

    authors: Ohuchi H,Satoh T,Eguchi Y,Mori K

    更新日期:2005-01-01 00:00:00

  • DOSIMETRIC ASPECTS OF OPTIMIZATION OF PROTECTION IN IRAN INDUSTRIAL RADIOGRAPHY PRACTICE.

    abstract::According to the worldwide reports, industrial radiography is one of the highest risk radiation practices due to handling high activity sources. Therefore, an optimization of protection along with appropriate investigation level and/or dose constraint is required to achieve appropriate radiological safety. This resear...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy021

    authors: Hosseini Pooya SM,Dashtipour MR

    更新日期:2018-10-01 00:00:00

  • Type Testing of Model 7200 Automatic TLD Reader.

    abstract::The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminesce...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw100

    authors: Malek Mohammadi M,Hosseini Pooya SM

    更新日期:2017-04-20 00:00:00

  • Independent evaluation of optically stimulated luminescence (OSL) 'dot' dosemeters for environmental monitoring.

    abstract::Optically stimulated luminescence (OSL) 'dot' dosemeters (manufactured by Landauer®) are reported to have a high degree of environmental stability, high level of sensitivity and provide wide range of dose measuring capabilities from 0.05 mGy to 100 Gy. The optical read out method is fast and relatively simple and perm...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq289

    authors: Timilsina B,Gesell TF

    更新日期:2011-01-01 00:00:00

  • Levels of depleted uranium in Kosovo soils.

    abstract::The United Nations Environment Programme (UNEP) has performed a field survey at 11 sites located in Kosovo, where depleted uranium (DU) ammunitions were used by the North Atlantic Treaty Organization (NATO) during the last Balkans conflict (1999). Soil sampling was performed to assess the spread of DU ground contamina...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006679

    authors: Sansone U,Stellato L,Jia G,Rosamilia S,Gaudino S,Barbizzi S,Belli M

    更新日期:2001-01-01 00:00:00

  • Investigation of radiation-induced multilayered signalling response of the inflammatory pathway.

    abstract::Ionising radiation exposure of cells might induce the perturbation of cell functions and, in particular, the activation or inhibition of several important pathways. This perturbation can cause the deregulation of both intra- and extra-cellular signalling cascades (such as the inflammatory pathway) and alter not only t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv132

    authors: Babini G,Ugolini M,Morini J,Baiocco G,Mariotti L,de Fatis PT,Liotta M,Ottolenghi A

    更新日期:2015-09-01 00:00:00

  • Simulation of 3D objects into breast tomosynthesis images.

    abstract::Digital breast tomosynthesis is a new three-dimensional (3D) breast-imaging modality that produces images of cross-sectional planes parallel to the detector plane from a limited number of X-ray projections over a limited angular range. Several technical and clinical parameters have not yet been completely optimised. S...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq084

    authors: Shaheen E,Zanca F,Sisini F,Zhang G,Jacobs J,Bosmans H

    更新日期:2010-04-01 00:00:00

  • Calibration of EPR signal dose response of tooth enamel to photons: experiment and Monte Carlo simulation.

    abstract::The experimental energy dependence of the electron paramagnetic resonance (EPR) radiation-induced signal at irradiation by photons in the energy range of 13 keV-1.25 MeV was analysed in terms of the absorbed dose in human tooth enamel. The latter was calculated using a Monte Carlo simulation of the photon and electron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch040

    authors: Ivannikov AI,Tikunov DD,Borysheva NB,Trompier F,Skvortsov VG,Stepanenko VF,Hoshi M

    更新日期:2004-01-01 00:00:00

  • Radiation protection culture: a global challenge.

    abstract::The central motto 'Radiation Protection Culture-A Global Challenge' of the fourth European IRPA Congress is discussed on the basis of the IRPA Guiding Principles Establishing a Radiation Protection Culture and the contributions presented in the plenary sessions of the conference. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu325

    authors: Michel R,Henrichs K,Wernli C