MICRODOSIMETRIC SIMULATIONS OF CARBON IONS USING THE MONTE CARLO CODE FLUKA.

Abstract:

:Therapeutic carbon ion beams produce a complex and variable radiation field that changes along the penetration depth due to the high density of energy loss along the particle track together with the secondary particles produced by nuclear fragmentation reactions. An accurate physical characterisation of such complex mixed-radiation fields can be performed by measuring microdosimetric spectra with mini tissue-equivalent proportional counters (mini-TEPCs), which are one of the most accurate devices used in experimental microdosimetry. Numerical calculations with Monte Carlo codes such as FLUKA can be used to supplement experimental microdosimetric measurements performed with TEPCs, but the nuclear cross sections and fragmentation models need to be benchmarked with experimental data for different energies and scenarios. The aim of this work is to compare experimental carbon microdosimetric data measured with the mini TEPC with calculated microdosimetry spectra obtained with FLUKA for 12C ions of 189.5 MeV/u in the Bragg peak region.

journal_name

Radiat Prot Dosimetry

authors

Chiriotti S,Conte V,Colautti P,Selva A,Mairani A

doi

10.1093/rpd/ncx201

subject

Has Abstract

pub_date

2018-08-01 00:00:00

pages

187-191

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

4282619

journal_volume

180

pub_type

杂志文章
  • RADIOLOGICAL HAZARD INDICES OF GRANITIC ROCKS USED FOR THE CONSTRUCTION OF BUILDINGS FROM NUBA MOUNTAINS SUDAN.

    abstract::This study was conducted to assess the level of radioactivity and the radiation hazards associated with granite rocks used for construction of buildings. The measurement of radioactivity content of the rock samples was performed with gamma-spectrometry equipped with Nal (TI) detector. From the results obtained in this...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx295

    authors: Fadol N,Idriss H,Salih I,Ragab NA,Osman S,Sam AK

    更新日期:2018-06-01 00:00:00

  • A large-scale measurement, analysis and modelling of electromagnetic radiation levels in the vicinity of GSM/UMTS base stations in an urban area.

    abstract::The present study analyses the electric field radiating from the GSM/UMTS base stations located in central Malatya, a densely populated urban area in Turkey. The authors have conducted both instant and continuous measurements of high-frequency electromagnetic fields throughout their research by using non-ionising radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv008

    authors: Karadağ T,Yüceer M,Abbasov T

    更新日期:2016-01-01 00:00:00

  • A fast and simple approach for the estimation of a radiological source from localised measurements after the explosion of a radiological dispersal device.

    abstract::After an explosion of a radiological dispersal device, decision-makers need to implement countermeasures as soon as possible to minimise the radiation-induced risks to the population. In this work, the authors present a tool, which can help providing information about the approximate size of source term and radioactiv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct263

    authors: Urso L,Kaiser JC,Woda C,Helebrant J,Hulka J,Kuca P,Prouza Z

    更新日期:2014-03-01 00:00:00

  • Filter, collimator and moderating material to achieve boron neutron capture enhanced fast neutron therapy.

    abstract::The combination of fast neutron therapy and boron neutron capture therapy is currently being studied as a possible treatment for some radio-resistant brain tumours. In an attempt to design a boron-enhanced fast neutron therapy beam for the Fermilab Fast Neutron Therapy Facility, the use of moderating material surround...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci256

    authors: Sweezy J,Hertel N,Lennox A

    更新日期:2005-01-01 00:00:00

  • Seasonal variation of indoor radon-222 levels in dwellings in Ramallah province and East Jerusalem suburbs, Palestine.

    abstract::This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated bu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr013

    authors: Leghrouz AA,Abu-Samreh MM,Shehadeh AK

    更新日期:2012-01-01 00:00:00

  • Radiation Protection Studies for Medical Particle Accelerators using Fluka Monte Carlo Code.

    abstract::Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw302

    authors: Infantino A,Cicoria G,Lucconi G,Pancaldi D,Vichi S,Zagni F,Mostacci D,Marengo M

    更新日期:2017-04-01 00:00:00

  • SAR distribution in human beings when using body-worn RF transmitters.

    abstract::This study analyzes the exposure of the human torso to electromagnetic fields caused by wireless body-mounted or handheld devices. Because of the frequency and distance ranges from 30-5800 MHz and 10 to 200 mm, respectively, both near-field and far-field effects are considered. A generic body model and simulations of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm377

    authors: Christ A,Samaras T,Neufeld E,Klingenböck A,Kuster N

    更新日期:2007-01-01 00:00:00

  • Spot measurements of intermediate frequency electric fields in the vicinity of compact fluorescent lamps.

    abstract::Starting in 2009, certain types of incandescent light bulbs will be withdrawn from the market in the European Union and elsewhere. However, compact fluorescent lamps that are among the candidates to replace them produce intermediate frequency electric fields (EFs) much higher than any other device or appliance previou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq276

    authors: Bakos J,Nagy N,Juhász P,Thuróczy G

    更新日期:2010-12-01 00:00:00

  • Risk management policies and practices regarding radio frequency electromagnetic fields: results from a WHO survey.

    abstract::This study aims to describe current risk management practices and policies across the world in relation to personal exposures from devices emitting radiofrequency fields, environmental exposures from fixed installations and exposures in the work environment. Data from 86 countries representing all WHO regions were col...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu324

    authors: Dhungel A,Zmirou-Navier D,van Deventer E

    更新日期:2015-04-01 00:00:00

  • Activity concentrations and mean annual effective dose from gamma-emitting radionuclides in the Lebanese diet.

    abstract::Since the primary factor contributing to the internal effective dose in the human organism is contaminated food, the control of radionuclides in food represents the most important means of protection. This study was conducted to determine the levels of the dietary exposure of the Lebanese population to gamma-emitting ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn160

    authors: Nasreddine L,El Samad O,Hwalla N,Baydoun R,Hamzé M,Parent-Massin D

    更新日期:2008-01-01 00:00:00

  • Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control.

    abstract::Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the prac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw241

    authors: Kobayashi M,Asada Y,Matsubara K,Suzuki S,Matsunaga Y,Haba T,Kawaguchi A,Daioku T,Toyama H,Kato R

    更新日期:2017-05-01 00:00:00

  • EPR DOSIMETRY STUDY FOR POPULATION RESIDING IN THE VICINITY OF FALLOUT TRACE FOR NUCLEAR TEST ON 7 AUGUST 1962.

    abstract::The method of electron paramagnetic resonance (EPR) dosimetry using extracted teeth has been applied to human tooth enamel to obtain individual absorbed doses of residents of settlements in the vicinity of the central axis of radioactive fallout trace from the contaminating surface nuclear test on 7 August 1962. Most ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw178

    authors: Zhumadilov KS,Ivannikov AI,Stepanenko VF,Toyoda S,Skvortsov VG,Hoshi M

    更新日期:2016-12-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00

  • Cytogenetic studies for a group of people living in Japan 1 year after the Fukushima nuclear accident.

    abstract::In order to understand the potential health effect of radiation from Fukushima nuclear disaster, a group of people living in Japan during and after the accident were investigated 1 y after the accident. The venous blood samples were extracted in tune from 156 tested persons living in Tokyo and Niigata with average age...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu180

    authors: Chen Y,Zhou PK,Zhang XQ,Wang ZD,Wang Y,Darroudi F

    更新日期:2014-06-01 00:00:00

  • Regional cooperation in RWM in the AO countries.

    abstract::Regional cooperation in radioactive waste management (RWM) in the Asian and Oceanic countries has been successfully developing for more than 20 y. At present, the Asian and Oceanic countries recognise that there are several projects under the regional cooperation, such as the Forum for Nuclear Cooperation in Asia (FNC...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr124

    authors: Ya-anant N,Thiangtrongjit S

    更新日期:2011-07-01 00:00:00

  • SIMULATION OF OSL AND TLD DOSEMETER RESPONSE FOR THE DEVELOPMENT OF NEW EXTREMITY DOSEMETERS.

    abstract::The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy299

    authors: Hoedlmoser H,Brönner J,Bandalo V,Wahl F,Greiter MB

    更新日期:2019-12-23 00:00:00

  • EURADOS coordinated action on research, quality assurance and training of internal dose assessments.

    abstract::EURADOS working group on 'Internal Dosimetry (WG7)' represents a frame to develop activities in the field of internal exposures as coordinated actions on quality assurance (QA), research and training. The main tasks to carry out are the update of the IDEAS Guidelines as a reference document for the internal dosimetry ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq435

    authors: Lopez MA,Balásházy I,Bérard P,Blanchardon E,Breustedt B,Broggio D,Castellani CM,Franck D,Giussani A,Hurtgen C,James AC,Klein W,Kramer GH,Li WB,Marsh JW,Malatova I,Nosske D,Oeh U,Pan G,Puncher M,Peixoto Telles P,

    更新日期:2011-03-01 00:00:00

  • Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

    abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp019

    authors: Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

    更新日期:2009-01-01 00:00:00

  • A theoretical study on accurate measurements of thoron with airflow-through scintillation cell method.

    abstract::For accurate measurements of (220)Rn concentration with airflow-through scintillation cell method, a theoretical study was performed for discussing the influences of sampling flow rate, volumes of sampling tube and scintillation cell on the measurements. It is found that a high flow rate and a large inner volume of sc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq252

    authors: Tang F,Zhuo W,Zhao C,Chen B,Xu Y,He L

    更新日期:2010-10-01 00:00:00

  • Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project.

    abstract::The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in differen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq508

    authors: Domienik J,Brodecki M,Carinou E,Donadille L,Jankowski J,Koukorava C,Krim S,Nikodemova D,Ruiz-Lopez N,Sans-Mercé M,Struelens L,Vanhavere F

    更新日期:2011-03-01 00:00:00

  • Measurement of neutron inelastic scattering cross sections for 52Cr from threshold up to 18 MeV.

    abstract::The powerful white neutron spectrum from Gelina is used for the investigation of gamma ray production cross sections in the reaction 52Cr(n,n'gamma)52Cr. The gamma rays from the inelastic process are detected with two large volume HPGe detectors placed at 110 degrees and 150 degrees with respect to the beam direction....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci199

    authors: Mihailescu LC,Borcea C,Plompen AJ

    更新日期:2005-01-01 00:00:00

  • Spatial distribution of indoor radon in Triveneto (Northern Italy): a geostatistical approach.

    abstract::The study of spatial distribution of the indoor radon has assumed in the last years a lot of interest. The geostatistical techniques turn out to be particularly promising. The present work presents the results of a study where around 4000 indoor radon data from Veneto, Friuli Venezia-Giulia and Alto Adige, collected d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp252

    authors: Bertolo A,Bigliotto C,Giovani C,Garavaglia M,Spinella M,Verdi L,Pegoretti S

    更新日期:2009-12-01 00:00:00

  • Development of a nanotechnology based low-LET multi-microbeam array single cell irradiation system.

    abstract::A novel single cell irradiation system using carbon nanotube (CNT) based field emission technology is proposed. The system can produce electron microbeam at a large range of pulsation frequencies and dose rates with energy between 20 and 60 keV. Different from any existing single beam microbeam device, the CNT-based s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl508

    authors: Chang S,Zhang J,Bordelon D,Schreiber E,Cox A,Zhou O

    更新日期:2006-01-01 00:00:00

  • Development of a new thoron progeny detector based on SSNTD and the collection by an electric field.

    abstract::The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found between indoor thoron and its progeny, and the concentration of thoron progeny varies with time, it is necessary to develop detectors for long-term measurement that...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr078

    authors: Bi L,Tschiersch J,Meisenberg O,Wielunski M,Li JL,Shang B

    更新日期:2011-05-01 00:00:00

  • A United States perspective on long-term management of areas contaminated with radioactive materials.

    abstract::The US has far-reaching and extensive experience in the long-term management of areas contaminated with radioactive materials. This experience base includes the Department of Energy's continued follow-up with Hiroshima and Nagasaki from the 1940s at the Radiological Effects Research Foundation in Hiroshima, Japan, the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nch255

    authors: Jones CR

    更新日期:2004-01-01 00:00:00

  • CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II.

    abstract::Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx236

    authors: Harrison J,Moreno B,Van Hoey O,Mihailescu LC,Vanhavere F,Million M,Fomenko V,Akselrod M

    更新日期:2018-08-01 00:00:00

  • Hardness ratios of different neutron spectra.

    abstract::Extensive data have been gathered in the past on the response of different detectors, based on the registration of neutron-induced fissions in bismuth, gold, tantalum and thorium by the spark-replica counter and the thin film breakdown counter. These detectors make it possible to exploit the excellent characteristics ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch168

    authors: Tommasino L,Tripathy SP

    更新日期:2004-01-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • PRACTICAL METHODS FOR INTERNAL DOSE ASSESSMENT FOR RADIOIODINE INTAKE AFTER THYROID BLOCKING: CLASSIFICATION OF DEGREE OF BLOCKAGE AND DETERMINATION OF INSENSITIVE MEASUREMENT POINT.

    abstract::Iodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz139

    authors: Kwon TE,Park M,Jung GH,Chung Y,Ha WH,Jin YW

    更新日期:2019-12-31 00:00:00

  • Plutonium isotopes in marine sediments and some biota from the Sudanese coast of the Red Sea.

    abstract::Measurements of (239+240)Pu and (238)Pu were carried out on marine biota as well as on sediments from the fringing reefs area extending towards north and south (Flamingo Bay) of PortSudan harbour. The analyses were performed using radiochemical separation and alpha spectrometry. The range of the activity concentration...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn193

    authors: Sirelkhatim DA,Sam AK,Hassona RK

    更新日期:2008-01-01 00:00:00