CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II.

Abstract:

:Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum neutron field at various angles are analyzed to determine a calibration curve for angular dependence. MCNPX simulations were shown to be in good agreement with experimental results. A prototype triage reader was also designed and tested for quick assessment of dose. An unfolding technique incorporating both energy dependence and angular dependence is discussed. The advantages and shortcomings of using FNTDs in the event of a criticality excursion accident are analyzed.

journal_name

Radiat Prot Dosimetry

authors

Harrison J,Moreno B,Van Hoey O,Mihailescu LC,Vanhavere F,Million M,Fomenko V,Akselrod M

doi

10.1093/rpd/ncx236

subject

Has Abstract

pub_date

2018-08-01 00:00:00

pages

201-205

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

4560567

journal_volume

180

pub_type

杂志文章
  • Why can't we find a better biological indicator of dose?

    abstract::The three general principles of the International Commission on Radiological Protection (ICRP) are: justification, optimisation (ALARA) and dose limitation. The principle application of optimisation (ALARA) for occupational exposures of workers or the public to external radiation is reliant on low doses being assessed...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch094

    authors: Voisin P,Roy L,Benderitter M

    更新日期:2004-01-01 00:00:00

  • Uncertainty evaluation of radon measurements with LR115 detector and spark counter.

    abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch361

    authors: Campi F,Caresana M,Ferrarini M,Garlati L,Palermo M,Rusconi R

    更新日期:2004-01-01 00:00:00

  • OCCUPATIONAL EXPOSURE TO RADON IN DIFFERENT KINDS OF NON-URANIUM MINES.

    abstract::For more accurate assessments of the occupational exposure to radon for miners, the individual monitoring was conducted by using an improved passive integrating (222)Rn monitor. A total of 120 miners in 3 different kinds of mines were monitored throughout a year. The results showed that the individual exposure to rado...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw026

    authors: Fan D,Zhuo W,Zhang Y

    更新日期:2016-09-01 00:00:00

  • Non-human Primate Total-body Irradiation Model with Limited and Full Medical Supportive Care Including Filgrastim for Biodosimetry and Injury Assessment.

    abstract::An assessment of multiple biomarkers from radiation casualties undergoing limited- or full-supportive care including treatment with filgrastim is critical to develop rapid and effective diagnostic triage strategies. The efficacy of filgrastim with full-supportive care was compared with results with limited-supportive ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw176

    authors: Ossetrova NI,Blakely WF,Nagy V,McGann C,Ney PH,Christensen CL,Koch AL,Gulani J,Sigal GB,Glezer EN,Hieber KP

    更新日期:2016-12-01 00:00:00

  • Anatomical data and development of geometric models for the knee region bones.

    abstract::Analytical geometric models for the bones of the knee region have been developed. A survey was done on real pieces to obtain the dimensions of the geometric sections used in each model. The dependence of the section dimensions on the bone length and the estimated dimensions of the bones for a 1.70 m tall person are pr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm445

    authors: Venturini L,Sordi GM,Fernandes F

    更新日期:2008-01-01 00:00:00

  • Neutron spectra unfolding in Bonner spheres spectrometry using neural networks.

    abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006158

    authors: Kardan MR,Setayeshi S,Koohi-Fayegh R,Ghiassi-Nejad M

    更新日期:2003-01-01 00:00:00

  • Calculation of the store house worker dose in a lost wax foundry using MCNP-4C.

    abstract::Lost wax casting is an industrial process which permits the transmutation into metal of models made in wax. The wax model is covered with a silicaceous shell of the required thickness and once this shell is built the set is heated and wax melted. Liquid metal is then cast into the shell replacing the wax. When the met...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci156

    authors: Alegría N,Legarda F,Herranz M,Idoeta R

    更新日期:2005-01-01 00:00:00

  • A new device to expose cells to changing dose rates of ionising radiation.

    abstract::In many exposure scenarios to ionising radiation, the dose rate is not constant. Despite this, most in vitro studies aimed at investigating the effects of ionising radiation are carried out exposing samples at constant dose rates. Consequently, very little data exist on the biological effects of exposures to changing ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr092

    authors: Brehwens K,Bajinskis A,Staaf E,Haghdoost S,Cederwall B,Wojcik A

    更新日期:2012-02-01 00:00:00

  • Lithium fluoride: from LiF:Mg,Ti to LiF:Mg,Cu,P.

    abstract::Differences and similarities between LiF-based LiF:Mg,Ti and LiF:Mg,Cu,P are discussed, with respect to their dosimetric properties--sensitivity, non-linearity of dose response and heavy charged particle efficiency, as related to the concentration and the individual role of the Mg, Ti, Cu and P dopants. To study furth...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005847

    authors: Bilski P

    更新日期:2002-01-01 00:00:00

  • Neutron dose distribution at the GSI fragment separator.

    abstract::GSI is operating a facility for the production of rare isotopes. Nuclei are produced by fragmentation or fission of the impinging heavy ions with energies of approximately 1 GeV per nucleon. The major part of the primary beam and the produced nuclei is deposited in the components of the Fragment Separator (FRS) and ge...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch210

    authors: Fehrenbacher G,Festag JG

    更新日期:2004-01-01 00:00:00

  • An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures.

    abstract::In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs in the Sou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006486

    authors: Waite JC,Fitzgerald M

    更新日期:2001-01-01 00:00:00

  • Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    abstract::In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr252

    authors: Veinot KG,Hertel NE

    更新日期:2012-04-01 00:00:00

  • The present ICRP protection quantitites are seriously flawed. Opposing the proposition.

    abstract::Our debaters have agreed to defend positions that appear to be diametrically opposed; nevertheless, they have acknowledged some common ground. Although it was not explicitly stated, they would no doubt agree that workers and the public are adequately protected by our present system of radiation regulations. Our debate...

    journal_title:Radiation protection dosimetry

    pub_type: 评论,杂志文章

    doi:

    authors: Edwards AA

    更新日期:2003-01-01 00:00:00

  • Breast cancer risk after radiation treatment at infancy: potential consequences of radiation-induced genomic instability.

    abstract::Swedish hemangioma patients were treated in infancy mainly by external application of radium-226 starting from 1920. This work analysed the radiation risk among 17,158 women with a total of 678 breast cancer incidence cases with models of carcinogenesis and empirical excess relative risk models. Models incorporating e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq473

    authors: Eidemüller M,Holmberg E,Jacob P,Lundell M,Karlsson P

    更新日期:2011-02-01 00:00:00

  • Effective dose to a patient undergoing coronary angiography.

    abstract::Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effecti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006466

    authors: Lobotessi H,Karoussou A,Neofotistou V,Louisi A,Tsapaki V

    更新日期:2001-01-01 00:00:00

  • A solid state microdosimeter based on a monolithic silicon telescope.

    abstract::A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl468

    authors: Agosteo S,Colautti P,Fazzi A,Moro D,Pola A

    更新日期:2006-01-01 00:00:00

  • Determination of personal dose equivalents in accelerator radiation fields.

    abstract::Values for the dose equivalent are required for radiation protection purposes, but determination of such values can be quite difficult for high energy radiations. The accurate determination of personal dose equivalents in accelerator radiation fields requires the propel use of appropriate radiological quantities and u...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006629

    authors: McDonald JC

    更新日期:2001-01-01 00:00:00

  • Protocols for dosimetry and patient reference levels.

    abstract::Doses in radiology should be as low as reasonably achievable. In order to compare practice in different centres it is necessary to compare patient doses. This can only be undertaken if dosimetry studies are similar. In order to facilitate comparisons, the DIMOND consortium developed a patient dosimetry protocol. Refer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci715

    authors: Faulkner K

    更新日期:2005-01-01 00:00:00

  • Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.

    abstract::Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci586

    authors: Ginjaume M,Pérez S,Ortega X,Duch MA

    更新日期:2006-01-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

    abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch013

    authors: Jönsson H,Mattsson S

    更新日期:2004-01-01 00:00:00

  • Indoor radon measurements in the dwellings of Punjab and Himachal Pradesh, India.

    abstract::The measurement of indoor radon concentrations were performed in the dwellings of the Punjab and Himachal Pradesh, India by using LR-115 type II Solid-State Nuclear Track Detectors in the bare mode. The annual average indoor radon concentrations in the dwellings are found to vary from 114 to 400 Bq m(-3) with an avera...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct041

    authors: Rani A,Singh S,Duggal V

    更新日期:2013-01-01 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00

  • Radon as a potential health hazard for clients and workers of selected thermal spas in Poland.

    abstract::The radiation exposure due to 222Rn and its progeny inhalation for clients and employees of selected thermal water spas was assessed. The radon risk was calculated using the measured 222Rn activity concentrations in the investigated thermal waters and radon transfer coefficient, defined as a fraction of radon released...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw359

    authors: Nowak J,Nguyen Dinh C

    更新日期:2017-07-01 00:00:00

  • Luminescence dosimetry using building materials and personal objects.

    abstract::There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci699

    authors: Göksu HY,Bailiff IK

    更新日期:2006-01-01 00:00:00

  • INTERVENTIONAL RADIOLOGICAL PROCEDURES MOST PRONE TO CAUSE HIGH PATIENT PEAK SKIN DOSES BASED ON REVIEW OF 7607 PROCEDURES.

    abstract::Peak skin doses to patients undergoing interventional radiological procedures in a 3-year period were assessed to identify the most critical procedures and evaluate probability for occurrence of radiation-induced tissue injuries. Data of 7607 patients were reviewed, identifying those with cumulative air kerma at a ref...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy119

    authors: Kuhelj D,Kovačič M,Zdešar U,Pekarovič D,Žontar D

    更新日期:2019-05-01 00:00:00

  • Natural radioactivity levels in lake sediment samples.

    abstract::The radioactivity concentrations of nuclides (238)U, (232)Th and (40)K in lake sediments collected from 15 different stations at Altınkaya dam lake and 12 different stations at Derbent dam lake in Turkey were measured using high-resolution gamma-ray spectrometry. The measurement was done using a coaxial HPGe detector ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct071

    authors: Eroğlu H,Kabadayi Ö

    更新日期:2013-09-01 00:00:00

  • MCNPX CALCULATIONS OF SPECIFIC ABSORBED FRACTIONS IN SOME ORGANS OF THE HUMAN BODY DUE TO APPLICATION OF 133Xe, 99mTc and 81mKr RADIONUCLIDES.

    abstract::Monte Carlo simulations were performed to evaluate treatment doses with wide spread used radionuclides 133Xe, 99mTc and 81mKr. These different radionuclides are used in perfusion or ventilation examinations in nuclear medicine and as indicators for cardiovascular and pulmonary diseases. The objective of this work was ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx181

    authors: Jovanovic Z,Krstic D,Nikezic D,Ros JMG,Ferrari P

    更新日期:2018-03-01 00:00:00

  • Protection from radon exposure at home and at work in the directive 2013/59/Euratom.

    abstract::In recent years, international organisations involved in radiation protection and public health have produced new guidance, recommendations and requirements aiming better protection from radon exposure. These organisations have often worked in close collaboration in order to facilitate the establishment of harmonised ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu101

    authors: Bochicchio F

    更新日期:2014-07-01 00:00:00

  • A review of the properties of the dosimetric systems and the quality assurance programmes of 48 dosimetric services in the European Union and Switzerland.

    abstract::This paper summarises the evaluation of the 1997 EURADOS questionnaire on dosimetric systems able to assess personal dose equivalent. In total, 56 approved dosimetric services in the European Union and Switzerland responded, together monitoring approximately 615,000 occupationally exposed persons. Of these services, 4...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006572

    authors: van Dijk JW,Bordy JM,Vanhavere F,Wernli C,Zamani-Valasiadou M

    更新日期:2001-01-01 00:00:00