Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

Abstract:

:Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, the method of treatment differs from country to country and even from hospital to hospital within the same country. To illuminate such differences 187 radioiodine treatments for Graves' disease at Malmö University Hospital in Sweden have been analysed. Comparative dose calculations were carried out assuming that the individual patients had also been treated according to a number of other protocols in current use. The results show that the protocol used for calculating the administered activity in radioiodine therapy is far from optimised in many hospitals. Following the protocols where the absorbed dose to the thyroid is calculated without any uptake measurements after administration of a test activity, most of the patients were treated with an unnecessarily high activity, as a mean factor of 2.5 times too high and in individual patients up to eight times too high, leading to an unnecessary radiation exposure both for the patient, the family and the public. This is not in accordance with generally accepted radiation protection principles. Using higher activity than necessary will also prolong the patient's stay at the hospital and thus increase the costs for the care. Unnecessarily high activity will also necessitate more long-lasting radiation protection restriction relative to family members when the patient is back home.

journal_name

Radiat Prot Dosimetry

authors

Jönsson H,Mattsson S

doi

10.1093/rpd/nch013

keywords:

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

107-14

issue

2

eissn

0144-8420

issn

1742-3406

pii

108/2/107

journal_volume

108

pub_type

杂志文章
  • New data on direct ion storage dosemeters.

    abstract::The DIS-1 dosemeter from the Finnish company RADOS is an innovative kind of passive electronic dosemeter for photon and beta radiation. This study examines the 'long-term' linear response behaviour, the calibration and readout accuracy with large samples of 'used' DIS-1 dosemeters especially in the low-dose region, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm240

    authors: Fuchs H,Stähler S,Dittmar M

    更新日期:2008-01-01 00:00:00

  • SAR distribution in human beings when using body-worn RF transmitters.

    abstract::This study analyzes the exposure of the human torso to electromagnetic fields caused by wireless body-mounted or handheld devices. Because of the frequency and distance ranges from 30-5800 MHz and 10 to 200 mm, respectively, both near-field and far-field effects are considered. A generic body model and simulations of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm377

    authors: Christ A,Samaras T,Neufeld E,Klingenböck A,Kuster N

    更新日期:2007-01-01 00:00:00

  • CT equipment and performance issues: radiation protection 162.

    abstract::Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in pa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs285

    authors: Edyvean S

    更新日期:2013-02-01 00:00:00

  • 238U CONTENT IN URINE OF URANIUM MINERS AND ITS MODELED VALUES.

    abstract::The aim of the study is to make a comparison of daily 238U excretion in urine among 115 active uranium miners and its modeled values obtained from inhalation intake of long-lived alpha emitters as measured by personal dosemeters and assessed by biokinetic models for different absorption parameters settings for inhaled...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx061

    authors: Kotík L,Becková V,Malátová I,Tomasek L

    更新日期:2017-12-01 00:00:00

  • Determination of human absorbed dose of 201Tl(III)-DTPA-HIgG based on biodistribution data in rats.

    abstract::To estimate the absorbed dose in normal organs and inflamed tissue following i.v. administration of [201Tl](III)-DTPA-HIgG by using biodistribution data in inflamation bearing rats was attempted. The percentages of injected dose per gram of each organ were calculated. The medical internal radiation dose formulation was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq172

    authors: Khorrami Moghaddam A,Reza Jalilian A,Hayati V,Shanehsazzadeh S

    更新日期:2010-10-01 00:00:00

  • Cellular signal transduction events as a function of linear energy transfer (LET).

    abstract::In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation, the number and size of pATM (S1981) and gamma-H2AX foci were compared in cultures of diploid human fibroblasts after exposure to charged particles of varying species, energ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm086

    authors: Fürweger C,Hajek M,Vana N,Kodym R,Okayasu R

    更新日期:2007-01-01 00:00:00

  • Neutron spectra unfolding in Bonner spheres spectrometry using neural networks.

    abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006158

    authors: Kardan MR,Setayeshi S,Koohi-Fayegh R,Ghiassi-Nejad M

    更新日期:2003-01-01 00:00:00

  • STRUCTURAL ANALYSIS OF DNA REPAIR PROTEIN XRCC4 APPLYING CIRCULAR DICHROISM IN AN AQUEOUS SOLUTION.

    abstract::We applied circular dichroism (CD) spectral analysis to obtain the secondary structure of the DNA repair protein XRCC4, with a focus on its C-terminus. Using synchrotron radiation as a light source across a wide range of wavelengths, including vacuum ultraviolet (UV) light from 180 to 200 nm and UV light from 200 to 2...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy275

    authors: Nishikubo K,Izumi Y,Matsumoto Y,Fujii K,Matsuo K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00

  • Determination of a neutron source position in an unknown homogeneous medium; the 2D case.

    abstract::The localisation of an unknown neutron source in various bulky homogeneous media was studied. For the planar case two (3)He detectors on the opposite faces of a box were used. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm048

    authors: Dubinski S,Presler O,Alfassi ZB

    更新日期:2007-01-01 00:00:00

  • Narrow beam dosimetry for high energy hadrons and electrons.

    abstract::Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10-400 GeV. The target organs considered were right eye, thyroid,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006556

    authors: Pelliccioni M,Silari M,Ulrici L

    更新日期:2001-01-01 00:00:00

  • A survey of patient dose and clinical factors in a full-field digital mammography system.

    abstract::In this work, we analyse the dose to 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography (FFDM) system over a 2-y period. The information relevant to this study has been extracted from the image Digital Imaging and Communications in Medicine (DICOM) headers. Entr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch514

    authors: Morán P,Chevalier M,Ten JI,Fernández Soto JM,Vañó E

    更新日期:2005-01-01 00:00:00

  • An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures.

    abstract::In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs in the Sou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006486

    authors: Waite JC,Fitzgerald M

    更新日期:2001-01-01 00:00:00

  • A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.

    abstract::A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NR...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv478

    authors: Walbersloh J,Busch F

    更新日期:2016-09-01 00:00:00

  • Radon diffusion coefficients in 360 waterproof materials of different chemical composition.

    abstract::This paper summarises the results of radon diffusion coefficient measurements in 360 common waterproof materials available throughout Europe. The materials were grouped into 26 categories according to their chemical composition. It was found that the diffusion coefficients of materials used for protecting houses again...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr043

    authors: Jiránek M,Kotrbatá M

    更新日期:2011-05-01 00:00:00

  • New diagnostic reference level for full-field digital mammography units.

    abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct136

    authors: Hauge IH,Bredholt K,Olerud HM

    更新日期:2013-12-01 00:00:00

  • Analysis of the reliability of the local effect model for the use in carbon ion treatment planning systems.

    abstract::In radiotherapy with carbon ions, biological effects of treatments have to be predicted. For this purpose, one of the most used models is the local effect model (LEM) developed at the Gesellschaft für Schwerionenforschung (GSI), Germany. At the Istituto Nazionale di Fisica Nucleare, Italy, the reliability of the last ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq407

    authors: Russo G,Attili A,Bourhaleb F,Marchetto F,Peroni C,Schmitt E,Bertrand D

    更新日期:2011-02-01 00:00:00

  • INITIAL EVALUATION OF INDIVIDUAL DOSES IN THE EARLY PHASE OF A NUCLEAR REACTOR ACCIDENT BASED ON IN-VIVO MONITORING DATA AND SIMULATED RADIOLOGICAL CONSEQUENCES.

    abstract::In the early phase of a nuclear reactor accident, in-vivo monitoring of impacted population would be highly useful to detect potential contamination during the passage of the cloud and to estimate the dose from inhalation of measured radionuclides. However, it would be important to take into account other exposure com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy277

    authors: Challeton-de Vathaire C,Quentric E,Didier D,Blanchardon E,Davesne E,Rannou A,Agarande M,Renaud-Salis V,Franck D

    更新日期:2019-11-30 00:00:00

  • Czech results at criticality dosimetry intercomparison 2002.

    abstract::Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters use...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/nch276

    authors: Frantisek S,Jaroslav T

    更新日期:2004-01-01 00:00:00

  • Measurements of radon concentrations in waters and soil gas of Zonguldak, Turkey.

    abstract::The radon concentrations in soil-gas and water samples (in the form of springs, catchment, tap, thermal) used as drinking water or thermal were measured using a professional radon monitor AlphaGUARD PQ 2000PRO. The measured radon concentrations in water samples ranged from 0.32 to 88.22 Bq l(-1). Most of radon levels ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct308

    authors: Koray A,Akkaya G,Kahraman A,Kaynak G

    更新日期:2014-12-01 00:00:00

  • Dose assessment from activated sodium within a body in criticality accidents.

    abstract::Some data were derived using recent sophisticated methods to rapidly convert specific activity of induced 24Na to average dose over a whole body in criticality accidents. Monte Carlo calculations using the MCNP-4B code were performed to study energy spectra of neutrons and gamma rays for some criticality systems with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006350

    authors: Takahashi F,Endo A,Yamaguchi Y

    更新日期:2003-01-01 00:00:00

  • Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry.

    abstract::The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al(2)O(3):C,Mg) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm058

    authors: Sykora GJ,Akselrod MS,Salasky M,Marino SA

    更新日期:2007-01-01 00:00:00

  • Reliability of the ICRP'S dose coefficients for members of the public: IV. basis of the human alimentary tract model and uncertainties in model predictions.

    abstract::The biokinetic and dosimetric model of the gastrointestinal (GI) tract applied in current documents of the International Commission on Radiological Protection (ICRP) was developed in the mid-1960s. The model was based on features of a reference adult male and was first used by the ICRP in Publication 30, Limits for In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl104

    authors: Leggett R,Harrison J,Phipps A

    更新日期:2007-01-01 00:00:00

  • Measurement of patient radiation doses in certain urography procedures.

    abstract::Patients are exposed to significant radiation doses during diagnostic and interventional urologic procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv185

    authors: Sulieman A,Barakat H,Zailae A,Abuderman A,Theodorou K

    更新日期:2015-07-01 00:00:00

  • Dose assessment for ingestion of a 330 kilobecquerel 60Co hot particle.

    abstract::On leaving the irradiated fuel bay at Pickering A nuclear power station, a worker triggered a whole body monitor alarm with activity in or on his head, and despite careful decontamination techniques he subsequently swallowed a hot particle. Over the next 3 d, the radioactivity was tracked through the body. It was then...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm256

    authors: Whillans DW,Chase WJ,Wolodarsky WH

    更新日期:2007-01-01 00:00:00

  • OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE.

    abstract::The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy057

    authors: Ubeda C,Morales C,Gutiérrez D,Oliveira M,Manterola C

    更新日期:2018-12-01 00:00:00

  • INVESTIGATION OF THERMOLUMINESCENCE CHARACTERISTICS OF Y2O3:Er3+ NANOPHOSPHORS.

    abstract::Thermoluminescence (TL) characteristics of Y2O3:Er3+ nanophosphor exposed to UV radiations were investigated. Combustion synthesis method was employed to synthesise the nanophosphors. The confirmation for the pure cubic phase was done by powder X-ray diffraction. The particles formed were found to have 23.19 nm size a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw014

    authors: Kaur M,Bisen DP,Brahme N,Singh P

    更新日期:2017-04-15 00:00:00

  • 131I DOSE ESTIMATION FROM INTAKE OF TAP WATER IN THE EARLY PHASE AFTER FUKUSHIMA DAIICHI NUCLEAR POWER PLANT ACCIDENT.

    abstract::In March 2011, the Fukushima Daiichi Nuclear Power Plant Accident occurred and a large amount of radionuclides was released. To study its effect, we estimated the internal exposure due to intake of tap water in the early phase after the accident. As the number of measured values of tap water following the accident was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx208

    authors: Kawai M,Yoshizawa N,Suzuki G

    更新日期:2018-04-01 00:00:00

  • Long-term measurements of radon equilibrium factor in Greek dwellings.

    abstract::The time variation of the radon equilibrium factor F was measured every four hours in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki (in northern Greece) during October 1998-April 1999. The time dependence of the mean weekly value of radon equilibrium factor F is relatively small. During...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006143

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • ORGANIC SCINTILLATOR FOR REAL-TIME NEUTRON DOSIMETRY.

    abstract::We developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept mea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx255

    authors: Beyer KA,Di Fulvio A,Stolarczyk L,Parol W,Mojzeszek N,Kopéc R,Clarke SD,Pozzi SA

    更新日期:2018-08-01 00:00:00