Measurements of radon concentrations in waters and soil gas of Zonguldak, Turkey.

Abstract:

:The radon concentrations in soil-gas and water samples (in the form of springs, catchment, tap, thermal) used as drinking water or thermal were measured using a professional radon monitor AlphaGUARD PQ 2000PRO. The measured radon concentrations in water samples ranged from 0.32 to 88.22 Bq l(-1). Most of radon levels in potable water samples are below the maximum contaminant level of 11 Bq l(-1) recommended by the US Environmental Protection Agency. The calculated annual effective doses due to radon intake through water consumption varied from 0.07 to 18.53 µSv y(-1). The radon concentrations in soil gas varied from 295.67 to 70 852.92 Bq m(-3). The radon level in soil gas was found to be higher in the area close to the formation boundary thrust and faults. No correlation was observed between radon concentrations in groundwater and soil gas. Also, no significant correlation was observed between soil-gas radon and temperature, pressure and humidity. The emanation of radon from groundwater and soil gas is controlled by the geological formation and by the tectonic structure of the area.

journal_name

Radiat Prot Dosimetry

authors

Koray A,Akkaya G,Kahraman A,Kaynak G

doi

10.1093/rpd/nct308

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

375-81

issue

3

eissn

0144-8420

issn

1742-3406

pii

nct308

journal_volume

162

pub_type

杂志文章
  • Radioactive pollution from Fukushima Daiichi nuclear power plant in the terrestrial environment.

    abstract::Major contaminants from venting and hydrogen explosions at the Fukushima Daiichi nuclear reactors between 12 and 15 March 2011 were transported northwestward and deposited on soil and plants via precipitation. Surface soils and plant leaves were sampled at 64 sites in the Fukushima Prefecture. The highest concentratio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs222

    authors: Tazoe H,Hosoda M,Sorimachi A,Nakata A,Yoshida MA,Tokonami S,Yamada M

    更新日期:2012-11-01 00:00:00

  • A theoretical study on accurate measurements of thoron with airflow-through scintillation cell method.

    abstract::For accurate measurements of (220)Rn concentration with airflow-through scintillation cell method, a theoretical study was performed for discussing the influences of sampling flow rate, volumes of sampling tube and scintillation cell on the measurements. It is found that a high flow rate and a large inner volume of sc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq252

    authors: Tang F,Zhuo W,Zhao C,Chen B,Xu Y,He L

    更新日期:2010-10-01 00:00:00

  • General guidelines for the assessment of internal dose from monitoring data: progress of the IDEAS project.

    abstract::In recent major international intercomparison exercises on intake and internal dose assessments from monitoring data, the results calculated by different participants varied significantly. Based on this experience the need for harmonisation of the procedures has been formulated within an EU 5th Framework Programme res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl132

    authors: Doerfel H,Andrasi A,Bailey M,Blanchardon E,Cruz-Suarez R,Berkovski V,Castellani CM,Hurtgen C,LeGuen B,Malatova I,Marsh J,Stather J,Zeger J

    更新日期:2007-01-01 00:00:00

  • Accreditation in radiation protection for cardiologists and interventionalists.

    abstract::Training in radiation protection is widely recognised as one of the basic components of optimisation programmes for medical exposures. Occupational and patient radiation risks in interventional radiology can be quite high and international bodies have shown concern on this item. Following recommendations of the Intern...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci730

    authors: Vano E,Gonzalez L

    更新日期:2005-01-01 00:00:00

  • Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

    abstract::Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl144

    authors: Falcão RC,Facure A,Silva AX

    更新日期:2007-01-01 00:00:00

  • STUDY OF 222RN CONTINUOUS MONITORING TIME SERIES AND DOSE ASSESSMENT IN SIX EUROPEAN CAVES.

    abstract::The present work aims to assess the effective doses from long-term continual radon monitoring in six European caves (Slovenia, Slovakia and the Czech Republic), including influencing environmental factors. Caves are important radiation protection subjects because of elevated radon activity concentration (~kBq/m3), mos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa159

    authors: Ambrosino F,Thinová L,Briestenský M,Sabbarese C

    更新日期:2020-11-27 00:00:00

  • INTERVENTIONAL RADIOLOGICAL PROCEDURES MOST PRONE TO CAUSE HIGH PATIENT PEAK SKIN DOSES BASED ON REVIEW OF 7607 PROCEDURES.

    abstract::Peak skin doses to patients undergoing interventional radiological procedures in a 3-year period were assessed to identify the most critical procedures and evaluate probability for occurrence of radiation-induced tissue injuries. Data of 7607 patients were reviewed, identifying those with cumulative air kerma at a ref...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy119

    authors: Kuhelj D,Kovačič M,Zdešar U,Pekarovič D,Žontar D

    更新日期:2019-05-01 00:00:00

  • Calculation of the store house worker dose in a lost wax foundry using MCNP-4C.

    abstract::Lost wax casting is an industrial process which permits the transmutation into metal of models made in wax. The wax model is covered with a silicaceous shell of the required thickness and once this shell is built the set is heated and wax melted. Liquid metal is then cast into the shell replacing the wax. When the met...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci156

    authors: Alegría N,Legarda F,Herranz M,Idoeta R

    更新日期:2005-01-01 00:00:00

  • Dosimetric monitoring in Ukraine--present status and path to the future.

    abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl128

    authors: Chumak V,Boguslavskaya A

    更新日期:2007-01-01 00:00:00

  • Measurements of radon gas concentrations in dwellings of Al-Madinah Al-Munawarah province in Saudi Arabia.

    abstract::Indoor radon concentration levels in a large number of dwellings in Al-Madinah Al-Munawarah Province have been measured. Al-Madinah Al-Munawarah is in the western region of Saudi Arabia. It is the second holiest city in Islam after Mecca, because it is the burial place of the Islamic Prophet Muhammad. The city was div...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct219

    authors: Mohamed RI,Alfull ZZ,Dawood ND

    更新日期:2014-01-01 00:00:00

  • Thermoluminescence properties of LiMgF3 doped with Ce, Er and Dy.

    abstract::The main dosimetric properties are reported of a new perovskite, LiMgF3, doped with Ce, Er and Dy impurities. An annealing temperature of 400 degrees C for one hour is necessary to erase any previous signal and to stabilise its sensitivity. A readout up to 450 degrees C gives the same result. The glow curve structure ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005858

    authors: Kitis G,Furetta C,Sanipoli C

    更新日期:2002-01-01 00:00:00

  • The response of a bonner sphere spectrometer to charged hadrons.

    abstract::Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch187

    authors: Agosteo S,Dimovasili E,Fassò A,Silari M

    更新日期:2004-01-01 00:00:00

  • An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures.

    abstract::In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs in the Sou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006486

    authors: Waite JC,Fitzgerald M

    更新日期:2001-01-01 00:00:00

  • The effect of Mg, Cu and P impurities on dose response of LiF:Mg,Cu,P phosphors: simulation versus experiments.

    abstract::In this research, the effect of magnesium (Mg), copper (Cu) and phosphorus (P) impurities on dosimetry response of LiF:Mg,Cu,P phosphors is studied experimentally and by the simulation procedure. In the experimental procedure, LiF:Mg,Cu,P phosphors in the powder form were synthesised by chemical co-precipitation metho...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv002

    authors: Mohammadi K,Khayat O,Afarideh H

    更新日期:2016-01-01 00:00:00

  • Uranium isotopes in public drinking water and dose assessment for man in Poland.

    abstract::238U, 234U and 235U were determined in tap water from municipal water pipes that drew their supply from surface water or ground water in various locations in Poland. Average activity concentrations of 238U, 234U and 235U in tap water from surface water were 9.6 +/- 7.1, 12.8 +/- 9.7 and 0.41 +/- 0.31 Bq m(-3), respect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch425

    authors: Pietrzak-Flis Z,Kaminska I,Chrzanowski E

    更新日期:2005-01-01 00:00:00

  • SIMULATION OF OSL AND TLD DOSEMETER RESPONSE FOR THE DEVELOPMENT OF NEW EXTREMITY DOSEMETERS.

    abstract::The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy299

    authors: Hoedlmoser H,Brönner J,Bandalo V,Wahl F,Greiter MB

    更新日期:2019-12-23 00:00:00

  • Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032854

    authors: Vana N,Schoner W,Noll M,Fugger M,Akatov Y,Shurshakov V

    更新日期:1999-01-01 00:00:00

  • Aircraft crew radiation workplaces: comparison of measured and calculated ambient dose equivalent rate data using the EURADOS in-flight radiation data base.

    abstract::In May 2000, the chairman of the European Radiation Dosimetry Group (EURADOS) invited a number of experts with experience of cosmic radiation dosimetry to form a working group (WG 5) on aircraft crew dosimetry. Three observers from the Article 31 Group of Experts as well as one observer from the Joint Aviation Authori...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl029

    authors: Beck P,Bartlett D,Lindborg L,McAulay I,Schnuer K,Schraube H,Spurny F

    更新日期:2006-01-01 00:00:00

  • A co-ordinated network for radiation dosimetry (CONRAD): an overview.

    abstract::The European Radiation Dosimetry Group (EURADOS) carried out a co-ordinated action, supported within the 6th Framework Programme of the European Commission entitled 'A Co-ordinated Network for Radiation Dosimetry (CONRAD)'. The project, executed from January 2005 to March 2008, yielded a large number of scientific res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn209

    authors: Schuhmacher H,Fantuzzi E

    更新日期:2008-01-01 00:00:00

  • Filter, collimator and moderating material to achieve boron neutron capture enhanced fast neutron therapy.

    abstract::The combination of fast neutron therapy and boron neutron capture therapy is currently being studied as a possible treatment for some radio-resistant brain tumours. In an attempt to design a boron-enhanced fast neutron therapy beam for the Fermilab Fast Neutron Therapy Facility, the use of moderating material surround...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci256

    authors: Sweezy J,Hertel N,Lennox A

    更新日期:2005-01-01 00:00:00

  • Neutron spectra unfolding in Bonner spheres spectrometry using neural networks.

    abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006158

    authors: Kardan MR,Setayeshi S,Koohi-Fayegh R,Ghiassi-Nejad M

    更新日期:2003-01-01 00:00:00

  • UNATTACHED 212PB FRACTION IN THE WORKER'S BREATHING ZONE AT HIGH THORON CONCENTRATIONS.

    abstract::Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa154

    authors: Zhukovsky M,Vasyanovich M,Onishchenko A

    更新日期:2020-11-27 00:00:00

  • A comparative study of dielectric response function models for liquid water.

    abstract::Various methodologies that aim at an analytic representation of the dielectric response function (DRF) of liquid water with emphasis on the Bethe ridge region are compared. The use of optical data is a common feature to all models presented providing an empirical ground for modelling the valence energy losses where ma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl414

    authors: Emfietzoglou D,Nikjoo H,Pathak A

    更新日期:2006-01-01 00:00:00

  • Worldwide bioassay data resources for plutonium/americium internal dosimetry studies.

    abstract::Biokinetic models are the scientific underpinning of internal dosimetry and depend, ultimately, for their scientific validation on comparisons with human bioassay data. Three significant plutonium/americium bioassay databases, known to the authors, are described: (1) Sellafield, (2) Los Alamos and (3) the United State...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm164

    authors: Miller G,Riddell AE,Filipy R,Bertelli L,Little T,Guilmette R

    更新日期:2007-01-01 00:00:00

  • Uncertainty evaluation of radon measurements with LR115 detector and spark counter.

    abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch361

    authors: Campi F,Caresana M,Ferrarini M,Garlati L,Palermo M,Rusconi R

    更新日期:2004-01-01 00:00:00

  • The study of activity median aerodynamic diameter using imaging plate technique for assessment of effective dose from radon and its decay products.

    abstract::The indoor workplace environment was evaluated for exposure to radon and its decay products at two Universities in two metropolises of Japan. The mean radon concentrations in Nagoya University (NU) and Hokkaido University (HU) were 16.7 Bq m(-3) and 18.0 Bq m(-3), respectively. Activity median aerodynamic diameter (AM...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncm221

    authors: Rahman NM,Iida T,Yamazawa H,Yokoyama S,Moriizumi J,Saito F,Ito T

    更新日期:2007-01-01 00:00:00

  • BETA DOSE EVALUATION ALGORITHM FOR CaSO4:Dy BYSED TLD BADGE USED IN COUNTRYWIDE PERSONNEL MONITORING PROGRAMME IN INDIA.

    abstract::The prevalent algorithm for the estimation of beta dose, which in turn is used for estimation of skin dose for exposures involving beta radiations was observed to significantly overestimate the dose in individual monitoring based on CaSO4:Dy TLD badge in India. A new algorithm has been developed by estimating the corr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw273

    authors: Rakesh RB,Kumar M,Sneha C,Ratna P,Datta D

    更新日期:2017-06-01 00:00:00

  • Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments.

    abstract::High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with (252)Cf neutron sources and are used in various wor...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu298

    authors: Lee KW,Sheu RJ

    更新日期:2015-04-01 00:00:00

  • The efficiency of various thermoluminescence dosemeter types to heavy ions.

    abstract::Dose verification in heavy-ion beams using passive dosemeter systems, e.g. thermoluminescence dosemeters (TLDs), is crucial due to the changing efficiency of the dosemeters for different ion species and linear energy transfer (LET) values. This behaviour leads to a falsification of absorbed dose that can be significan...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci582

    authors: Berger T,Hajek M,Summerer L,Fugger M,Vana N

    更新日期:2006-01-01 00:00:00

  • Characterisation of non-constant background in counting measurements.

    abstract::A 'moving-target' method for characterising background in a counting measurement in which the instantaneous background count rate is a function of time, rather than being fixed, is proposed. This model treats the average Poisson mean in observation period P as coming from a gamma distribution with parameters αP and βP...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu297

    authors: Klumpp J,Miller G,Brandl A

    更新日期:2015-04-01 00:00:00