Measurements of radon gas concentrations in dwellings of Al-Madinah Al-Munawarah province in Saudi Arabia.

Abstract:

:Indoor radon concentration levels in a large number of dwellings in Al-Madinah Al-Munawarah Province have been measured. Al-Madinah Al-Munawarah is in the western region of Saudi Arabia. It is the second holiest city in Islam after Mecca, because it is the burial place of the Islamic Prophet Muhammad. The city was divided into four regions: western (contains nine sites), eastern (contains six sites), northern (contains nine sites) and southern (contains five sites). Radon gas concentration was measured using the closed chamber technique employing 2×2 cm(2) sheets of CR-39 solid-state nuclear track detectors. The detectors were kept for a period of 5 to 6 months from September 2010 to February 2011 in order to expose to radon gas. The results of the survey in the western and eastern sites showed that the overall minimum, maximum and average radon concentration levels were 20±1.6, 27±3.2 and 21±2.5 Bq m(-3), respectively. The lowest average radon concentration (20±1.6 Bq m(-3)) was found in Al Anabes and Al Suqya in the western region and Bani Dhafar in the eastern region, while the highest average concentration (27±3.2 Bq m(-3)) was found in Teeyba in the western region and Al 'Aridh in the eastern region, with an average of 21±2.5 Bq m(-3) in the western and eastern sites of Al-Madinah Al-Munawarah. Also in the northern region, the minimum radon concentration was 20±1.6 Bq m(-3) in Oyun, while the maximum was 42±1.6 Bq m(-3) in Sayyed al Shuhadd and Hai Nasr. In the southern region, the minimum radon concentration was 25±2.6 Bq m(-3) at Hai Al Hejrah, while the maximum value was 37±2.6 Bq m(-3) at Al Awali and Dawadia. The average radon concentration was 26±2.5 Bq m(-3) for Al-Madinah Al-Munawarah (western, eastern, northern and southern regions). The corresponding annual effective dose E (mSv y(-1)) to public from (222)Rn and its progeny was estimated to be 0.66 mSv y(-1) as an average value for Al-Madinah Al-Munawarah. The authors concluded that all the dwellings monitored for indoor radon concentration and annual effective dose show values within the permissible level and this is a blessing from God that this area, which many visitors come from all over the world (to visit the burial place of the Prophet Muhammad), is safe. Consequently, the health hazards related to radiation are expected to be negligible. Occupants of these dwellings are relatively safe.

journal_name

Radiat Prot Dosimetry

authors

Mohamed RI,Alfull ZZ,Dawood ND

doi

10.1093/rpd/nct219

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

156-61

issue

2

eissn

0144-8420

issn

1742-3406

pii

nct219

journal_volume

158

pub_type

杂志文章
  • Secondary neutron doses in proton therapy treatments of ocular melanoma and craniopharyngioma.

    abstract::Monte Carlo simulations were used to assess secondary neutron doses received by patients treated with proton therapy for ocular melanoma and craniopharyngioma. MCNPX calculations of out-of-field doses were done for ∼20 different organs considering realistic treatment plans and using computational phantoms representati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct283

    authors: Farah J,Sayah R,Martinetti F,Donadille L,Lacoste V,Hérault J,Delacroix S,Nauraye C,Vabre I,Lee C,Bolch WE,Clairand I

    更新日期:2014-10-01 00:00:00

  • Early effects comparison of X-rays delivered at high-dose-rate pulses by a plasma focus device and at low dose rate on human tumour cells.

    abstract::A comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT). Experiments have been performed at 0.5 and 2 Gy doses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv163

    authors: Virelli A,Zironi I,Pasi F,Ceccolini E,Nano R,Facoetti A,Gavoçi E,Fiore MR,Rocchi F,Mostacci D,Cucchi G,Castellani G,Sumini M,Orecchia R

    更新日期:2015-09-01 00:00:00

  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00

  • Assessment of the Absorbed Dose in the Kidney of Nuclear Nephrology Paediatric Patients using ICRP Biokinetic Data and Monte Carlo Simulations with Mass-Scaled Paediatric Voxel Phantoms.

    abstract::The aim of this work is to use Monte Carlo simulations and VOXEL phantoms to estimate the absorbed dose in paediatric patients (aged from 2 weeks to 16 y), with normal renal function, to whom technetium-99m-dimercaptosuccinic acid (99mTc-DMSA) was administered, for diagnostic renal scintigraphy purposes; and compare t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw096

    authors: Teles P,Mendes M,Zankl M,de Sousa V,Santos AI,Vaz P

    更新日期:2017-04-20 00:00:00

  • Quality assurance (QA) procedures for software: evaluation of an ADC quality system.

    abstract::Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci742

    authors: Efstathopoulos EP,Benekos O,Molfetas M,Charou E,Kottou S,Argentos S,Kelekis NL

    更新日期:2005-01-01 00:00:00

  • Radon in waterworks: dose assessment, analysis of influence parameters and improved methods of measurement.

    abstract::In Austria a comprehensive study on radiation exposure in waterworks was conducted. The aim of this study was to evaluate the risks for the affected employees. On the basis of geographical, geological and hydrological aspects, 21 waterworks were selected. A total of 85 passive short-term measurements and measurements ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu067

    authors: Michael S,Andreas B,Claudia S,Fabian R,Ringer W,Josef MF

    更新日期:2014-07-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • DESIGN IMPROVEMENT OF A LIQUID-MODERATOR-BASED NEUTRON SPECTROMETER FOR BNCT.

    abstract::Boron neutron capture therapy is known to be an effective radiation cancer therapy that requires neutron irradiation. A neutron field generated by an accelerator-based neutron source has various energy spectra, and it is necessary to evaluate the neutron spectrum in the treatment field. However, the method used to mea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx237

    authors: Tamaki S,Kusaka S,Sato F,Murata I

    更新日期:2018-08-01 00:00:00

  • SPECTROSCOPIC STUDY ON POLY(ACRYLIC ACID-CO-ACRYLAMIDE)-GRAFT-POLYANILINE AS A RADIATION DOSIMETER FOR ALPHA PARTICLES.

    abstract::Poly(acrylate-co-acrylamide) was a synthesis by chemical oxidation polymerization of an aqueous binary mixture of acrylate/acrylamide (1:1 mole ratio) using ammonium persulphate as an initiator at 70°C under the nitrogen atmosphere. The obtained copolymer was introduced for grafting with polyaniline. The grafting proc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx124

    authors: Abd El-Mageed HR,Abd El-Salam HM,Eissa MF

    更新日期:2018-03-01 00:00:00

  • Discussion on optimisation below dose limit for public using background-cancer-risk-based approach.

    abstract::To improve a radiological protection system, the lower bound of optimisation was discussed using a newly proposed background-cancer-risk-based approach. This approach provides a new finding that the standard deviation of the background cancer risk in Japan is 7.4 × 10(-5) y(-1). If this risk level corresponding to 1σ ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr150

    authors: Hattori T

    更新日期:2011-07-01 00:00:00

  • Dose conversion of radon exposure according to new epidemiological findings.

    abstract::In 1993, ICRP-65 recommended that dose conversion of radon exposure should be based on the comparison of detriments between radon exposure and effective dose. The lifetime detriment from the radon exposure was projected according to the epidemiological studies of uranium miners then available. The projection model (GS...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn117

    authors: Tomasek L,Rogel A,Laurier D,Tirmarche M

    更新日期:2008-01-01 00:00:00

  • Comparison of various anthropomorphic phantom types for in vivo measurements by means of Monte Carlo simulations.

    abstract::Three widely used anthropomorphic phantoms are analysed with regard to their suitability for the efficiency calibration of whole-body counters (WBCs): a Bottle Manikin Absorber (BOMAB) phantom consisting of water-filled plastic containers, a St Petersburg block phantom (Research Institute of Sea Transport Hygiene, St ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq320

    authors: Schläger M

    更新日期:2011-03-01 00:00:00

  • Assessment of natural radioactivity concentrations and gamma dose rate levels in Kayseri, Turkey.

    abstract::This study assesses the level of background radiation for Kayseri province of Turkey. Natural radionuclide activity concentrations in soil samples were determined using high-resolution gamma spectroscopy. Outdoor gamma dose measurements in air at 1 m above ground level were determined using a portable gamma scintillat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr023

    authors: Otansev P,Karahan G,Kam E,Barut I,Taskin H

    更新日期:2012-01-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • VISUALIZATION OF THE DNA REPAIR PROCESS IN MAMMALIAN CELLS TRANSFECTED WITH EGFP-EXPRESSING PLASMID DNA AFTER EXPOSURE TO X-RAYS IN VITRO.

    abstract::To investigate the repair process of DNA damage induced by ionizing radiation in isolation from various types of cytoplasmic damage, we transfected X-irradiated enhanced green fluorescent protein (EGFP)-expressing plasmid DNA into non-irradiated mammalian cells using lipofectamine. The repair kinetics of the irradiate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy241

    authors: Nakaue H,Obata Y,Kaminaga K,Akimitsu N,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Childhood leukaemia near British nuclear installations: methodological issues and recent results.

    abstract::In 2008, the German Childhood Cancer Registry published the results of the Kinderkrebs in der Umgebung von Kernkraftwerken (KiKK) study of childhood cancer and leukaemia around German nuclear power stations. The positive findings appeared to conflict with the results of a recent British analysis carried out by the Com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncn254

    authors: Bithell JF,Keegan TJ,Kroll ME,Murphy MF,Vincent TJ

    更新日期:2008-01-01 00:00:00

  • Inter-laboratory test program (PTI) in 'neutron dosimetry'.

    abstract::The Laboratory of External Dosimetry Studies and Researches (LRDE), associated laboratory to the Bureau National de Métrologie, is strongly involved in the reference establishment and calibration of instruments in neutron radiation fields provided by 241Am-Be, 252Cf and (252Cf + D2O)/Cd sources. In 1997, on the reques...

    journal_title:Radiation protection dosimetry

    pub_type: 指南,杂志文章,多中心研究

    doi:10.1093/rpd/nch193

    authors: Van-Ryckeghem L,Pelcot G,Suder F,Bureau National de Métrologie.

    更新日期:2004-01-01 00:00:00

  • Evaluation of solid state nuclear track detector stacks exposed on the international space station.

    abstract::The aim of the study was to investigate the contribution of secondary neutrons to the total dose inside the International Space Station (ISS). For this purpose solid-state nuclear track detector (SSNTD) stacks were used. Each stack consisted of three CR-39 sheets. The first and second sheets were separated by a Ti pla...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch140

    authors: Pálfalvi JK,Akatov Y,Szabó J,Sajó-Bohus L,Eördögh I

    更新日期:2004-01-01 00:00:00

  • Dose tracking and radiology department management.

    abstract::The purpose of this work was to review the reasonable measures that should be implemented as part of a routine practice in the process of managing CT radiation risks in a typical average radiology department. Based on 6 y of experience in the management of a general radiology department and the newly implemented suppo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv038

    authors: Kirova G,Georgiev E,Zasheva C,St Georges A

    更新日期:2015-07-01 00:00:00

  • Looking into future: challenges in radiation protection in medicine.

    abstract::Radiation protection in medicine is becoming more and more important with increasing wider use of X-rays, documentation of effects besides the potential for long-term carcinogenic effects. With computed tomography (CT) likely to become sub-mSv in coming years, positron emission tomography (PET), single photon emission...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv071

    authors: Rehani MM

    更新日期:2015-07-01 00:00:00

  • Activity concentrations and mean annual effective dose from gamma-emitting radionuclides in the Lebanese diet.

    abstract::Since the primary factor contributing to the internal effective dose in the human organism is contaminated food, the control of radionuclides in food represents the most important means of protection. This study was conducted to determine the levels of the dietary exposure of the Lebanese population to gamma-emitting ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn160

    authors: Nasreddine L,El Samad O,Hwalla N,Baydoun R,Hamzé M,Parent-Massin D

    更新日期:2008-01-01 00:00:00

  • 226Ra AND 228Ra CONCENTRATIONS IN SOILS WITH INTENSE GROUNDWATER IRRIGATION IN AN ARID ENVIRONMENT.

    abstract::The enhancing effect due to long-time irrigation with radium-containing groundwater on soil was investigated in this work. Samples from the Al-Qassim and Hail areas in Saudi Arabia were studied for their 226Ra and 228Ra inventories. Groundwater and soil samples were collected from 32 farms where agricultural activitie...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz287

    authors: Ebaid YY

    更新日期:2020-06-24 00:00:00

  • Uncertainty evaluation of radon measurements with LR115 detector and spark counter.

    abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch361

    authors: Campi F,Caresana M,Ferrarini M,Garlati L,Palermo M,Rusconi R

    更新日期:2004-01-01 00:00:00

  • The first operational dosemeter for neutrons which complies with IEC standard 1323.

    abstract::Individual neutron dosimetry represents one of the current difficulties in the field of radiological protection of workers. Since March 1999, the regulatory requirements in France for active (i.e. operational) dosimetry have been those of ICRP Publication 60, applicable from May 2000, necessitating the introduction of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006592

    authors: Lahaye T,Cutarella D,Ménard S,Bolognese-Milsztajn T

    更新日期:2001-01-01 00:00:00

  • Personal monitor glass badge: theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX.

    abstract::This paper describes the results of the simulation of a radiophotoluminescent (RPL) dosemeter with the Monte Carlo transport code MCNPX. The aim of this study is to calculate the response with MCNPX of the RPL dosemeter in terms of equivalent doses H(p) (0.07) and H(p)(10) using X-ray photon radiation qualities N seri...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr009

    authors: Hocine N,Donadille L,Huet C,Itié C,Clairand I

    更新日期:2011-03-01 00:00:00

  • Review of retrospective dosimetry techniques for external ionising radiation exposures.

    abstract::The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by indivi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncq499

    authors: Ainsbury EA,Bakhanova E,Barquinero JF,Brai M,Chumak V,Correcher V,Darroudi F,Fattibene P,Gruel G,Guclu I,Horn S,Jaworska A,Kulka U,Lindholm C,Lloyd D,Longo A,Marrale M,Monteiro Gil O,Oestreicher U,Pajic J,Rakic B

    更新日期:2011-11-01 00:00:00

  • SOIL 222Rn CONCENTRATION, CO2 AND CH4 FLUX MEASUREMENTS AROUND THE JWALAMUKHI AREA OF NORTH-WEST HIMALAYAS, INDIA.

    abstract::Soil 222Rn concentration, CO2 and CH4 flux measurements were conducted around the Jwalamukhi area of North-West Himalayas, India. During this study, around 37 soil gas points and flux measurements were taken with the aim to assure the suitability of this method in the study of fault zones. For this purpose, RAD 7 (Dur...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw071

    authors: Kumar A,Walia V,Yang TF,Fu CC,Singh S,Bajwa BS,Arora V

    更新日期:2016-10-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • Cytogenic investigations of serious overexposures to an industrial gamma radiography source.

    abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006090

    authors: Sevan'kaev AV,Lloyd DC,Edwards AA,Moquet JE,Nugis VY,Mikhailova GM,Potetnya OI,Khvostunov IK,Guskova AK,Baranov AE,Nadejina NM

    更新日期:2002-01-01 00:00:00

  • High-Dose TL Dosimetry of Reactor Neutrons.

    abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx244

    authors: Obryk B,Malik K,Bilski P,Igielski A,Dankowski J,Kurowski A,Prokopowicz R,Pytel K

    更新日期:2018-08-01 00:00:00