Abstract:
:The prevalent algorithm for the estimation of beta dose, which in turn is used for estimation of skin dose for exposures involving beta radiations was observed to significantly overestimate the dose in individual monitoring based on CaSO4:Dy TLD badge in India. A new algorithm has been developed by estimating the correction factor from the response of dosemeter to different beta sources at various angles of incidence. The correction factor was observed to vary linearly with the ratio of the responses of dosemeter element without filter (D3) and dosemeter element under Perspex filter (D2). The correction factor determined using the ratio of D3 and D2 was applied to the response (D3) of dosemeter element without filter for estimation of beta dose. Protocol for identification of beta in the mixed gamma beta fields was defined such that it resulted in nearly same correction factor for given beta source in both gamma beta mixed fields and pure beta fields. The beta dose evaluation algorithm has provided the beta dose estimation within the required accuracy for >90% cases obtained from national quality assurance test data from different laboratories.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Rakesh RB,Kumar M,Sneha C,Ratna P,Datta Ddoi
10.1093/rpd/ncw273subject
Has Abstractpub_date
2017-06-01 00:00:00pages
96-103issue
1eissn
0144-8420issn
1742-3406pii
ncw273journal_volume
175pub_type
杂志文章abstract::In 2000 and 2001 about 279 and 221 radiation workers, respectively, were monitored by the Federal Radiation Protection Service, University of Ibadan, in Nigeria. The distribution of the occupational doses shows that the majority of workers received doses below 4 mSv in each of the two years. The radiation workers in t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006116
更新日期:2003-01-01 00:00:00
abstract::Radiation protection in medicine is becoming more and more important with increasing wider use of X-rays, documentation of effects besides the potential for long-term carcinogenic effects. With computed tomography (CT) likely to become sub-mSv in coming years, positron emission tomography (PET), single photon emission...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv071
更新日期:2015-07-01 00:00:00
abstract::The radioisotopic content of 17 samples of natural and manufactured building materials collected in Tunisia have been analysed by using gamma spectrometry. From the measured gamma ray spectra, activity concentrations are determined for (232)Th, (226)Ra, (235)U and (40)K. The total effective dose and the activity conce...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch489
更新日期:2005-01-01 00:00:00
abstract::The European Basic Safety Standards demand the prediction of areas where a significant number of households exceed the reference level for the radon activity concentration. Therefore, radon maps are established which are based on indoor and soil gas measurements. In this study results of soil gas measurements are inte...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx141
更新日期:2017-11-01 00:00:00
abstract::Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw266
更新日期:2017-06-01 00:00:00
abstract::In order to determine the exposure to natural sources of radiation for people in the vicinity of remediated Hungarian uranium mine regional surveys were carried out. The surveys evaluated indoor radon concentrations and outdoor and indoor external gamma dose rates. Radon concentration has been measured with nuclear et...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci363
更新日期:2006-01-01 00:00:00
abstract::This paper describes the objectives and reviews the progress of EULEP Working Party 5, convened under the auspices of the European Union's Fifth Framework Programme, to 'cluster' two EU-supported contracts, Biokinetics and Dosimetry of Internal Contamination (BIODOS (EU Contract FIS5-1999-00214)) and Radionuclide Biok...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006318
更新日期:2003-01-01 00:00:00
abstract::An investigation of the thermoluminescence (TL) properties of high pressure, high temperature (HPHT) synthetic diamond crystals grown under diluted nickel or cobalt as solvent catalysts is reported. After a study of TL properties of 6 different samples, it is shown that a crystal grown with Ni+2%Ti and annealed at 210...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005880
更新日期:2002-01-01 00:00:00
abstract::The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protect...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci702
更新日期:2005-01-01 00:00:00
abstract::In order to estimate typical radio frequency exposures from indoor used wireless communication technologies applied in homes and offices, WLAN, Bluetooth and Digital Enhanced Cordless Telecommunications systems, as well as baby surveillance devices and wireless headphones for indoor usage, have been investigated by me...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm245
更新日期:2007-01-01 00:00:00
abstract::For more accurate measurement of the potential alpha energy concentration (PAEC) of radon progeny by the liquid scintillation counting (LSC) method, its counting efficiency was studied in this work. A radon progeny standard source was used to provide different concentrations of radon progeny, and the progeny collected...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz069
更新日期:2019-10-01 00:00:00
abstract::Biokinetic models are the scientific underpinning of internal dosimetry and depend, ultimately, for their scientific validation on comparisons with human bioassay data. Three significant plutonium/americium bioassay databases, known to the authors, are described: (1) Sellafield, (2) Los Alamos and (3) the United State...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm164
更新日期:2007-01-01 00:00:00
abstract::Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effec...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv539
更新日期:2016-09-01 00:00:00
abstract::Image quality for similar exposure conditions has been compared for two computed radiography (CR) systems (needle-based and conventional storage phosphor) and two flat-panel (DR) systems from different manufacturers mainly devoted to chest radiology. Image quality was assessed with a contrast-detail object and acrylic...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn026
更新日期:2008-01-01 00:00:00
abstract::Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is ass...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch209
更新日期:2004-01-01 00:00:00
abstract::The neural network method has been used for the unfolding of neutron spectra in neutron spectrometry by Bonner spheres. A back propagation algorithm was used for training of neural networks. 4 mm x 4 mm bare LiI (Eu) and in a polyethylene sphere set: 2, 3, 4, 5, 6, 7, 8, 10, 12, 18 inch diameter have been used for unf...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006158
更新日期:2003-01-01 00:00:00
abstract::This paper summarises the evaluation of the 1997 EURADOS questionnaire on dosimetric systems able to assess personal dose equivalent. In total, 56 approved dosimetric services in the European Union and Switzerland responded, together monitoring approximately 615,000 occupationally exposed persons. Of these services, 4...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/oxfordjournals.rpd.a006572
更新日期:2001-01-01 00:00:00
abstract::This paper presents the values of radon and thoron progeny concentrations for different seasons in the dwellings of Tehri Garhwal, India. The measurements have been carried out using LR-115 solid-state nuclear track detector-based passive time-integrated direct thoron progeny sensor/direct radon progeny sensor techniq...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv224
更新日期:2015-11-01 00:00:00
abstract::The Workshop on Emergency Preparedness for Vulnerable Population Groups was held on 2 and 3 March 2009 in Ottawa, ON, Canada. The purpose of the workshop was to enhance communications within the emergency community response network and to identify the needs and gaps of emergency preparedness against chemical, biologic...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp083
更新日期:2009-06-01 00:00:00
abstract::Magnetic resonance imaging (MRI) is one of the most common sources of electromagnetic (EM) fields as a diagnostic technique widely used in medicine. MRI staff during the working day is constantly exposed to static and spatially heterogeneous magnetic field. Also, moving around the MRI room to perform their functions, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy114
更新日期:2018-12-01 00:00:00
abstract::The aim of the present work is to investigate the possibility of using the properties of the thermoluminescent emission (TL) of Brazilian natural topaz for dosimetric applications. Topaz is an aluminium fluorsilicate with general composition of Al2(SiO4)(F,OH)2 found with relative abundance in Brazil and in other part...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005902
更新日期:2002-01-01 00:00:00
abstract::In the United Kingdom it is a legal requirement that the radiation doses received by classified persons are measured using dosemeters that have been provided by an approved dosimetry service. The Health and Safety Executive (HSE) is the regulatory body responsible for approving these dosimetry services. Until recently...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/oxfordjournals.rpd.a006612
更新日期:2001-01-01 00:00:00
abstract::EURADOS working group on 'Internal Dosimetry (WG7)' represents a frame to develop activities in the field of internal exposures as coordinated actions on quality assurance (QA), research and training. The main tasks to carry out are the update of the IDEAS Guidelines as a reference document for the internal dosimetry ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq435
更新日期:2011-03-01 00:00:00
abstract::The RABiT (Rapid Automated Biodosimetry Tool) is a dedicated Robotic platform for the automation of cytogenetics-based biodosimetry assays. The RABiT was developed to fulfill the critical requirement for triage following a mass radiological or nuclear event. Starting from well-characterized and accepted assays we deve...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw172
更新日期:2016-12-01 00:00:00
abstract::The ESOREX project was initiated in 1997 by the EC DG TREN and it was executed by the BfS/Germany in close co-operation with the State Office for Nuclear Safety/Czech Republic). It consists of surveys on radiation monitoring and exposure carried out in the 30 European states. The study provides comparable descriptions...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl566
更新日期:2007-01-01 00:00:00
abstract::The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm095
更新日期:2007-01-01 00:00:00
abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx244
更新日期:2018-08-01 00:00:00
abstract::The natural radionuclide (226Ra, 232Th and 40K) contents of building materials commonly used in South Korea have been determined by a gamma ray spectroscopy system using a high purity germanium detector. The radon exhalation rates and emanation coefficients of building materials have also been studied. The average con...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006499
更新日期:2001-01-01 00:00:00
abstract::The radioactivity concentrations of nuclides (238)U, (232)Th and (40)K in lake sediments collected from 15 different stations at Altınkaya dam lake and 12 different stations at Derbent dam lake in Turkey were measured using high-resolution gamma-ray spectrometry. The measurement was done using a coaxial HPGe detector ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct071
更新日期:2013-09-01 00:00:00
abstract::The aim of this work was to experimentally compare the contrast improvement factors (CIFs) of a newly developed software-based scatter correction to the CIFs achieved by an antiscatter grid. To this end, three aluminium discs were placed in the lung, the retrocardial and the abdominal areas of a thorax phantom, and di...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv432
更新日期:2016-06-01 00:00:00