High-Dose TL Dosimetry of Reactor Neutrons.

Abstract:

:Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for measurements in order to evaluate neutron and non-neutron components of the radiation field in the reactor channel during exposure and to check their relevancy for dose measurements in the reactor environment. For high-dose evaluation a new Ultra-High-Temperature Ratio (UHTR) method established for highly sensitive LiF:Mg,Cu,P detectors has been applied. Neutron fluence evaluated from TL measurements was in good agreement with one calculated using neutron flux data during the experiment.

journal_name

Radiat Prot Dosimetry

authors

Obryk B,Malik K,Bilski P,Igielski A,Dankowski J,Kurowski A,Prokopowicz R,Pytel K

doi

10.1093/rpd/ncx244

subject

Has Abstract

pub_date

2018-08-01 00:00:00

pages

235-239

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

4614419

journal_volume

180

pub_type

杂志文章
  • Electric and magnetic fields generated by ac power lines: an application of advanced modelling tools in order to predict exposure levels.

    abstract::In view of expected legislation changes imposing more severe limits on magnetic flux density, proposals are made based on theory and measurement for adjustment of Fower placement with regard to efficiency, cost and cost-benefit. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006689

    authors: Manco D,Bruzzi L,Soloni A,Valbonetti D,Fabbri S,Violanti S

    更新日期:2001-01-01 00:00:00

  • Investigation of the neutron contribution in the 6 MeV to 7 MeV high energy photon reference field.

    abstract::In order to provide reference fields for the ionising radiation, PTB operates the ion accelerator facility. Referring to high energy photons, reference fields according to International Organization for Standardization 4037 series are produced. The neutron component of the 6-7 MeV photon field (R-F), which is produced...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp101

    authors: Röttger S,Heiske A,Nolte R

    更新日期:2009-07-01 00:00:00

  • Thermoluminescent properties of Ni and Co doped synthetic, high pressure, high temperature diamonds: application to ionising radiation dosimetry.

    abstract::An investigation of the thermoluminescence (TL) properties of high pressure, high temperature (HPHT) synthetic diamond crystals grown under diluted nickel or cobalt as solvent catalysts is reported. After a study of TL properties of 6 different samples, it is shown that a crystal grown with Ni+2%Ti and annealed at 210...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005880

    authors: Benabdesselam M,Iacconi P,Gheeraert E,Kanda H,Lapraz D,Briand D

    更新日期:2002-01-01 00:00:00

  • Dose imaging with gel-dosemeter layers: optical analysis and dedicated software.

    abstract::In radiotherapy involving thermal and epithermal neutrons, the knowledge of dose distributions, with separation of the contribution of each secondary radiation component, is of utmost importance. Layers of Fricke-Xylenol-Orange-infused gel dosemeters give the possibility of achieving such requirements because, owing t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci625

    authors: Gambarini G,Carrara M,Gay S,Tomatis S

    更新日期:2006-01-01 00:00:00

  • Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control.

    abstract::Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the prac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw241

    authors: Kobayashi M,Asada Y,Matsubara K,Suzuki S,Matsunaga Y,Haba T,Kawaguchi A,Daioku T,Toyama H,Kato R

    更新日期:2017-05-01 00:00:00

  • DEVELOPMENT OF A NEW SECONDARY STANDARD FOR H*(10).

    abstract::A secondary standard for ambient dose equivalent, H*(10), is necessary for the dissemination of the unit Sievert (Sv), but there is no such standard commercially available currently. Furthermore, the measurement of H*(10) instead of calculating H*(10) from air kerma and conversion coefficients is needed for unknown ra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz296

    authors: Bairlein K,Behnke B,Hupe O

    更新日期:2020-06-24 00:00:00

  • RECOMMENDATIONS FOR MONITORING AND INTERNAL DOSIMETRY FOR NUCLEAR MEDICINE STAFF EXPOSED TO RADIOPHARMACEUTICALS 223Ra DICHLORIDE.

    abstract::223Ra is a radiopharmaceutical used as unsealed source in nuclear medicine. In the case of staff inhalation contamination of 223Ra, methods to estimate the committed effective dose should be chosen with care. Three methods are available: whole-body measurement and gamma spectrometry for urine or faeces samples. Consid...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy065

    authors: Saurat D,Aupée O,Gontier E,Métivier D,Cazoulat A,Lecompte Y

    更新日期:2018-12-01 00:00:00

  • Migration of global radioactive fallout to the Arctic Ocean (on the example of the Ob's river drainage basin).

    abstract::This article provides an assessment of the impact of global fallout on (137)Cs contamination in the bottom sediments of Kara Sea. The erosiveness of 10th-level river basins was estimated by landscape-geochemical and geomorphological characteristics. All 10th-level basins (n=154) were separated into three groups: mount...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs195

    authors: Miroshnikov A,Semenkov I

    更新日期:2012-11-01 00:00:00

  • Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital.

    abstract::Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibilit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq059

    authors: Johnsson AA,Vikgren J,Svalkvist A,Zachrisson S,Flinck A,Boijsen M,Kheddache S,Månsson LG,Båth M

    更新日期:2010-04-01 00:00:00

  • Radical distributions in ammonium tartrate single crystals exposed to photon and neutron beams.

    abstract::The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu033

    authors: Marrale M,Longo A,Barbon A,Brustolon M,Brai M

    更新日期:2014-10-01 00:00:00

  • The Mayak Worker Dosimetry System (MWDS-2013): Estimate of Pu Content in Lungs and Thoracic Lymph Nodes From a Limited Set of Organ Autopsy Samples.

    abstract::A method to estimate plutonium content from a limited number of samples of lungs and pulmonary lymph nodes obtained at autopsies of former Mayak Production Association (MPA) workers is described. Historically from one to five samples of lung lobes and one to three respiratory lymph nodes (bronchopulmonary, tracheobron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw218

    authors: Sokolova AB,Suslova KG,Miller SC

    更新日期:2017-11-01 00:00:00

  • Czech results at criticality dosimetry intercomparison 2002.

    abstract::Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters use...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/nch276

    authors: Frantisek S,Jaroslav T

    更新日期:2004-01-01 00:00:00

  • Radiation protection at low energy proton accelerators.

    abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006619

    authors: Moritz LE

    更新日期:2001-01-01 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • MEASUREMENTS OF SPATIAL CORRELATIONS OF IONISATION CLUSTERS IN THE TRACK OF CARBON IONS-FIRST RESULTS.

    abstract::An attempt towards an experimental set up which could provide the experimental data on correlation processes occurred simultaneously in two distanced DNA targets within a charged particle track is presented. A modified Jet Counter nanodosemeter was used in two experiments with carbon ions with mean energies of 52 and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy079

    authors: Pietrzak M,Pszona S,Bantsar A

    更新日期:2018-08-01 00:00:00

  • Assessment of natural radioactivity concentrations and gamma dose rate levels in Kayseri, Turkey.

    abstract::This study assesses the level of background radiation for Kayseri province of Turkey. Natural radionuclide activity concentrations in soil samples were determined using high-resolution gamma spectroscopy. Outdoor gamma dose measurements in air at 1 m above ground level were determined using a portable gamma scintillat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr023

    authors: Otansev P,Karahan G,Kam E,Barut I,Taskin H

    更新日期:2012-01-01 00:00:00

  • RADON EXHALATION FROM SOIL AND ITS DEPENDENCE FROM ENVIRONMENTAL PARAMETERS.

    abstract::An automatic measuring apparatus called exhalometer for measurement of the radon exhalation rate from soil is introduced. It consists of a pneumatic driven accumulation chamber with an open bottom, a PC-based control system, six Lucas cells for radon measurement and sensors for environmental parameters. It allows movi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx165

    authors: Yang J,Buchsteiner M,Salvamoser J,Irlinger J,Guo Q,Tschiersch J

    更新日期:2017-11-01 00:00:00

  • A high-sensitivity method for the measurement of 222Rn based on liquid scintillation counting of polycarbonate powder.

    abstract::This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu075

    authors: Mitev K,Georgiev S,Pressyanov D,Dimitrova I,Zhivkova V,Boshkova T

    更新日期:2014-07-01 00:00:00

  • Neutron dose distribution at the GSI fragment separator.

    abstract::GSI is operating a facility for the production of rare isotopes. Nuclei are produced by fragmentation or fission of the impinging heavy ions with energies of approximately 1 GeV per nucleon. The major part of the primary beam and the produced nuclei is deposited in the components of the Fragment Separator (FRS) and ge...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch210

    authors: Fehrenbacher G,Festag JG

    更新日期:2004-01-01 00:00:00

  • A large-scale measurement, analysis and modelling of electromagnetic radiation levels in the vicinity of GSM/UMTS base stations in an urban area.

    abstract::The present study analyses the electric field radiating from the GSM/UMTS base stations located in central Malatya, a densely populated urban area in Turkey. The authors have conducted both instant and continuous measurements of high-frequency electromagnetic fields throughout their research by using non-ionising radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv008

    authors: Karadağ T,Yüceer M,Abbasov T

    更新日期:2016-01-01 00:00:00

  • Quality assurance (QA) procedures for software: evaluation of an ADC quality system.

    abstract::Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci742

    authors: Efstathopoulos EP,Benekos O,Molfetas M,Charou E,Kottou S,Argentos S,Kelekis NL

    更新日期:2005-01-01 00:00:00

  • A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    abstract::Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw266

    authors: Bonin A,Tsilanizara A

    更新日期:2017-06-01 00:00:00

  • Determination of radon concentration levels in well water in Konya, Turkey.

    abstract::Radon ((222)Rn) measurements were undertaken in 16 samples of well water representing different depths and different types of aquifers found at the city centre of Konya, Central Turkey. The radon activity concentrations of the well water samples collected in the spring and summer seasons of 2012 were measured by using...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct099

    authors: Erdogan M,Eren N,Demirel S,Zedef V

    更新日期:2013-10-01 00:00:00

  • Comparison of effective doses from various monoenergetic particles based on the stylised and the VIP-Man tomographic models.

    abstract::This study compares the effective doses from a MIRD-type stylised model with those derived from the scaled-down version of the tomographic VIP-Man model for photon, electron, neutron and proton beams. The effective dose results from these two models show that they differ from each other within approximately 10% for co...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci116

    authors: Xu XG,Chao TC,Bozkurt A

    更新日期:2005-01-01 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00

  • The influence of caesium-137 distribution in Poland's north-eastern ecosystem on effective dose 10 years after the Chernobyl disaster.

    abstract::A comparison is presented of particular methods of exposure in the first year after the Chernobyl disaster and ten years later. This comparison shows that the population exposure due to the presence of radiocaesium in the environment results from the presence of caesium contained in the soil, which provides 68% of the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006725

    authors: Zalewski M,Kapala J,Tomczak M

    更新日期:2002-01-01 00:00:00

  • Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes.

    abstract::Internal contamination due to high-energy photon (HEP) emitters is assessed using a scanning bed whole-body monitor housed in a steel room at the Bhabha Atomic Research Centre (BARC). The monitor consists of a (203 mm diameter × 102 mm thickness) NaI(Tl) detector and is calibrated using a Reference BOMAB phantom repre...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr203

    authors: Bhati S,Patni HK,Ghare VP,Singh IS,Nadar MY

    更新日期:2012-03-01 00:00:00

  • Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoring.

    abstract::In this paper, the results aimed at assessing the performance of two varieties of LiF detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) in photon fields relatively to reproducibility, detection threshold and angular dependence as defined in the ISO 12794 standard are presented. The fading properties and the limit of detection wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq366

    authors: Freire LC,Pereira MF,Calado AM,Santos LM,Cardoso JV,Alves JG

    更新日期:2011-03-01 00:00:00

  • Studies on the current 137Cs body burden of children in Belarus--can the dose be further reduced?

    abstract::After the Chernobyl reactor accident wide areas of Belarus were contaminated with radioactive fallout. The verification and documentation of the long-term development of radiation doses is still going on. A population group of special concern are the children living in contaminated regions. The annual dose limit of 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm153

    authors: Hill P,Schläger M,Vogel V,Hille R,Nesterenko AV,Nesterenko VB

    更新日期:2007-01-01 00:00:00

  • Calibration measurements and standards for radiation protection dosimetry.

    abstract::The safe use of ionising radiation for applications in medicine, electric power production and industrial processes requires accurate measurements that are traceable to national standards. Radiological calibration laboratories provide measurements that may be used to determine the calibration coefficients for personal...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nch308

    authors: McDonald JC

    更新日期:2004-01-01 00:00:00