MEASUREMENT OF THE POTENTIAL ALPHA ENERGY CONCENTRATION OF RADON PROGENY BY USING LIQUID SCINTILLATION COUNTING METHOD.

Abstract:

:For more accurate measurement of the potential alpha energy concentration (PAEC) of radon progeny by the liquid scintillation counting (LSC) method, its counting efficiency was studied in this work. A radon progeny standard source was used to provide different concentrations of radon progeny, and the progeny collected on the sampling filters were measured with a low background liquid scintillation counter. The result showed that the quenching effect could not be ignored, and the counting efficiency was estimated to be 86.12%. The co-comparison experiments showed that the PAECs of radon progeny measured by the LSC methods were in generally consistent with those of other three methods. It indicates that for more accurate measurements of PAEC of radon progeny by using the LSC method, the counting efficiency should be well determined.

journal_name

Radiat Prot Dosimetry

authors

Feng B,Tang Q,Zhang H,Chen B,Qiu S,Zhuo W

doi

10.1093/rpd/ncz069

subject

Has Abstract

pub_date

2019-10-01 00:00:00

pages

440-443

issue

3-4

eissn

0144-8420

issn

1742-3406

pii

5480493

journal_volume

184

pub_type

杂志文章
  • Dosimetry of a set-up for the exposure of newborn mice to 2.45-GHZ WiFi frequencies.

    abstract::This work describes the dosimetry of a two waveguide cell system designed to expose newborn mice to electromagnetic fields associated with wireless fidelity signals in the frequency band of 2.45 GHz. The dosimetric characterisation of the exposure system was performed both numerically and experimentally. Specific meas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq129

    authors: Pinto R,Lopresto V,Galloni P,Marino C,Mancini S,Lodato R,Pioli C,Lovisolo GA

    更新日期:2010-08-01 00:00:00

  • A new position recording system for the partial-body counter at KIT.

    abstract::The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq416

    authors: Hegenbart L,Breustedt B

    更新日期:2011-03-01 00:00:00

  • Detection system built from commercial integrated circuits for real-time measurement of radiation dose and quality using the variance method.

    abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm231

    authors: Hsu WH,Braby LA,Reece WD

    更新日期:2008-01-01 00:00:00

  • Internal dosimetry verification and validation database.

    abstract::Simulated-data internal dosimetry cases for use in intercomparison exercises or as a software verification and validation tool have been published on the internet (www.lanl.gov/bayesian/software Bayesian software package II). A user may validate their internal dosimetry code or method using this simulated bioassay dat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm470

    authors: Miller G,Bertelli L,Little T,Guilmette RA

    更新日期:2007-01-01 00:00:00

  • Radiation doses in cerebral perfusion computed tomography: patient and phantom study.

    abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs260

    authors: Arandjic D,Bonutti F,Biasizzo E,Ciraj-Bjelac O,Floreani M,Giustizieri M,Iaiza F,Inkoom S,Tommasini G,Padovani R

    更新日期:2013-05-01 00:00:00

  • Computed tomography dose index for head CT in northern Nigeria.

    abstract::Computed tomography dose index w and dose length product were recorded for the purpose of developing diagnostic reference levels (DRLs) for radiation dose optimisation. The study was conducted in three radiology departments with CT centres in Northern Nigeria. Data were collected from 54 consenting adult participants ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncv188

    authors: Garba I,Engel-Hills P,Davidson F,Tabari AM

    更新日期:2015-07-01 00:00:00

  • MEASUREMENTS IN AFGHANISTAN USING AN ACTIVE RADON EXPOSURE METER AND ASSESSMENT OF RELATED ANNUAL EFFECTIVE DOSE.

    abstract::Radon gas concentrations in eight basements, four living rooms and four caves from different locations in Kabul and Panjsher, Afghanistan, were measured by using eight active radon exposure meters recently developed by the Helmholtz Center in Munich, Germany. The two-phase measurements lasted from a week to a year. In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx086

    authors: Tanha MR,Vahlbruch JW,Riebe B,Irlinger J,Rühm W,Khalid FR,Storai A,Walther C

    更新日期:2018-01-01 00:00:00

  • Inter-comparison among different TLD-based techniques in a standard multisphere assembly for the characterisation of neutron fields.

    abstract::In the framework of collaboration among the ENEA Radiation Protection Institute (Bologna), the ENEA Fusion Department (Frascati) and the INFN-LNF-Radiation Protection Group (Frascati), an experimental campaign was organised on the usage of thermoluminescence dosemeters (TLDs) for the dosimetric and spectrometric chara...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci577

    authors: Bedogni R,Angelone M,Esposito A,Chiti M

    更新日期:2006-01-01 00:00:00

  • Blood tritium level as an estimate of soft tissue dose.

    abstract::To test the blood tritium level as an estimate of free water tritium (FWT) and organically bound tritium (OBT) in human soft tissues, a tritiated amino acid mixture (TAA) and tritiated water (HTO) were injected or orally administered to mice. Relatively high tritium retention in the blood was found after TAA injection...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006272

    authors: Saito M

    更新日期:2003-01-01 00:00:00

  • Radon in waterworks: dose assessment, analysis of influence parameters and improved methods of measurement.

    abstract::In Austria a comprehensive study on radiation exposure in waterworks was conducted. The aim of this study was to evaluate the risks for the affected employees. On the basis of geographical, geological and hydrological aspects, 21 waterworks were selected. A total of 85 passive short-term measurements and measurements ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu067

    authors: Michael S,Andreas B,Claudia S,Fabian R,Ringer W,Josef MF

    更新日期:2014-07-01 00:00:00

  • Review of the correlation between results of cytogenetic dosimetry from blood lymphocytes and EPR dosimetry from tooth enamel for victims of radiation accidents.

    abstract::The goal of this study was to compare dose estimates from electron paramagnetic resonance (EPR) dosimetry with teeth and cytogenetic dosimetry with blood lymphocytes for 30 victims of radiation accidents. The whole-body exposures estimated by tooth enamel EPR dosimetry were ranging from 0.01 to 9.3 Gy. Study group com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu203

    authors: Khvostunov IK,Ivannikov AI,Skvortsov VG,Nugis VY,Golub EV

    更新日期:2015-03-01 00:00:00

  • Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control.

    abstract::Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the prac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw241

    authors: Kobayashi M,Asada Y,Matsubara K,Suzuki S,Matsunaga Y,Haba T,Kawaguchi A,Daioku T,Toyama H,Kato R

    更新日期:2017-05-01 00:00:00

  • Methodology for Simple Spot Measurement of Equilibrium Equivalent Radon Concentration.

    abstract::Estimation of the effective inhalation dose of short half-life radon progeny requires the quantification of radon equilibrium equivalent activity concentrations (EEC, Ceq). The aim of the present study is to develop new methodology that focuses on spot measurements to determine EEC from single gross alpha counts and d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa176

    authors: Sakoda A,Ishimori Y,Kanzaki N,Tanaka H

    更新日期:2020-11-13 00:00:00

  • Induced radioactivity in and around high-energy particle accelerators.

    abstract::Particle accelerators and their surroundings are locations of residual radioactivity production that is induced by the interaction of high-energy particles with matter. This paper gives an overview of the principles of activation caused at proton accelerators, which are the main machines operated at Conseil Européen p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr245

    authors: Vincke H,Theis C,Roesler S

    更新日期:2011-07-01 00:00:00

  • BAYESIAN SPECTRUM DECONVOLUTION INCLUDING UNCERTAINTIES AND MODEL SELECTION: APPLICATION TO X-RAY EMISSION DATA USING WINBUGS.

    abstract::Spectrum deconvolution is an important task in ionizing radiation measurements, as the pulse height spectra, or, in general, the measured data from spectrometers or other measuring instruments are usually determined by the convolution of the response function with the fluence spectra. The method presented here for obt...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy286

    authors: Behrens R,Reginatto M

    更新日期:2019-12-23 00:00:00

  • A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    abstract::Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw266

    authors: Bonin A,Tsilanizara A

    更新日期:2017-06-01 00:00:00

  • Soil gas radon measurements in a region of the Bohemian Massif: investigations in the framework of an Austrian pilot study.

    abstract::Soil gas radon measurements are carried out in a pilot study in three municipalities in Upper Austria. The selected municipalities are characterised by a high radon potential. Sixty measuring sites--well distributed over the region and over the different geological areas--were selected. Additionally, the permeability ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr089

    authors: Seidel C,Baumgartner A,Ringer W,Gräser J,Friedmann H,Kaineder H,Maringer FJ

    更新日期:2011-05-01 00:00:00

  • Application of the high-temperature ratio method for evaluation of the depth distribution of dose equivalent in a water-filled phantom on board space station Mir.

    abstract::A water-filled tissue equivalent phantom with a diameter of 35 cm was developed at the Institute for Biomedical Problems. Moscow. Russia. It contains four channels perpendicular to each other, where dosemeters can be exposed at different depths. Between May 1997 and February 1999 the phantom was installed at three dif...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005923

    authors: Berger T,Hajek M,Schöner W,Fugger M,Vana N,Akatov Y,Shurshakov V,Arkhangelsky V,Kartashov D

    更新日期:2002-01-01 00:00:00

  • Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital.

    abstract::Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibilit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq059

    authors: Johnsson AA,Vikgren J,Svalkvist A,Zachrisson S,Flinck A,Boijsen M,Kheddache S,Månsson LG,Båth M

    更新日期:2010-04-01 00:00:00

  • Photoneutron and capture gamma dose equivalent for different room and maze layouts in radiation therapy.

    abstract::In this paper the effect of treatment room and maze layout on the photoneutron and capture gamma dose equivalent in the maze was studied. MCNPX Monte Carlo (MC) code was used to simulate the Varian 2100 C/D Clinac 18 MV and four different room layouts. Two analytical methods, Wu-McGinley and McGinley, were used for do...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp303

    authors: Mesbahi A,Ghiasi H,Mahdavi SR

    更新日期:2010-08-01 00:00:00

  • A solid state microdosimeter based on a monolithic silicon telescope.

    abstract::A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl468

    authors: Agosteo S,Colautti P,Fazzi A,Moro D,Pola A

    更新日期:2006-01-01 00:00:00

  • General guidelines for the assessment of internal dose from monitoring data: progress of the IDEAS project.

    abstract::In recent major international intercomparison exercises on intake and internal dose assessments from monitoring data, the results calculated by different participants varied significantly. Based on this experience the need for harmonisation of the procedures has been formulated within an EU 5th Framework Programme res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl132

    authors: Doerfel H,Andrasi A,Bailey M,Blanchardon E,Cruz-Suarez R,Berkovski V,Castellani CM,Hurtgen C,LeGuen B,Malatova I,Marsh J,Stather J,Zeger J

    更新日期:2007-01-01 00:00:00

  • Radiative models for the evaluation of the UV radiation at the ground.

    abstract::The variety of radiative models for solar UV radiation is discussed. For the evaluation of measured UV radiation at the ground the basic problem is the availability of actual values of the atmospheric parameters that influence the UV radiation. The largest uncertainties are due to clouds and aerosol, which are highly ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp211

    authors: Koepke P

    更新日期:2009-12-01 00:00:00

  • Thorium isotopic analysis by alpha spectrometry.

    abstract::The technique of alpha spectrometry is used to detect alpha particles and to determine their energy. In this way the technique is able to provide simultaneously quantitative information (i.e. the activity) and qualitative information (the identity) on any radionuclide that emits an alpha particle. The longer-lived nat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006646

    authors: Gingell T

    更新日期:2001-01-01 00:00:00

  • Filter, collimator and moderating material to achieve boron neutron capture enhanced fast neutron therapy.

    abstract::The combination of fast neutron therapy and boron neutron capture therapy is currently being studied as a possible treatment for some radio-resistant brain tumours. In an attempt to design a boron-enhanced fast neutron therapy beam for the Fermilab Fast Neutron Therapy Facility, the use of moderating material surround...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci256

    authors: Sweezy J,Hertel N,Lennox A

    更新日期:2005-01-01 00:00:00

  • Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital.

    abstract::The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch508

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra for radiobiology studies.

    abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006532

    authors: Pattison JE,Hugtenburg RP,Charles MW,Beddoe AH

    更新日期:2001-01-01 00:00:00

  • Measurements of radon gas concentrations in dwellings of Al-Madinah Al-Munawarah province in Saudi Arabia.

    abstract::Indoor radon concentration levels in a large number of dwellings in Al-Madinah Al-Munawarah Province have been measured. Al-Madinah Al-Munawarah is in the western region of Saudi Arabia. It is the second holiest city in Islam after Mecca, because it is the burial place of the Islamic Prophet Muhammad. The city was div...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct219

    authors: Mohamed RI,Alfull ZZ,Dawood ND

    更新日期:2014-01-01 00:00:00

  • Radiation protection at low energy proton accelerators.

    abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006619

    authors: Moritz LE

    更新日期:2001-01-01 00:00:00

  • Maximum likelihood estimates of mean and variance of occupation radiation doses subjected to minimum detection levels.

    abstract::Data collection and its analysis in the field of nuclear safety is an important task in the sense that it powers the improvement of safety as well as reliability of the plant. Thus, occupational exposure data analysis is presented to measure the safety or reliability of radiation protection of a given facility. It als...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm483

    authors: Datta D,Singh S,Johnson BE,Kushwaha HS

    更新日期:2008-01-01 00:00:00