Radon in waterworks: dose assessment, analysis of influence parameters and improved methods of measurement.

Abstract:

:In Austria a comprehensive study on radiation exposure in waterworks was conducted. The aim of this study was to evaluate the risks for the affected employees. On the basis of geographical, geological and hydrological aspects, 21 waterworks were selected. A total of 85 passive short-term measurements and measurements with active devices for the detection of 222Rn were conducted and compared regarding their applicability to waterworks. Additionally, the results of 47 passive combined 222Rn/220Rn measurements for the detection of 220Rn are part of this paper. 222Rn was determined in row water samples. The influences of water flow rates and of the 222Rn activity concentration in water on the 222Rn activity concentration in indoor air of water supplies were investigated. On the basis of the results of radon measurements at 165 points, the annual effective doses for 74 persons of the staff were determined.

journal_name

Radiat Prot Dosimetry

authors

Michael S,Andreas B,Claudia S,Fabian R,Ringer W,Josef MF

doi

10.1093/rpd/ncu067

subject

Has Abstract

pub_date

2014-07-01 00:00:00

pages

138-42

issue

1-3

eissn

0144-8420

issn

1742-3406

pii

ncu067

journal_volume

160

pub_type

杂志文章
  • ANALYSIS BY SCANNER OF TRACKS PRODUCED BY RADON ALPHA PARTICLES IN CR-39 DETECTORS.

    abstract::The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa140

    authors: Sabbarese C,Ambrosino F,Roca V

    更新日期:2020-11-27 00:00:00

  • On a model-based approach to radiation protection.

    abstract::There is a preoccupation with linearity and absorbed dose as the basic quantifiers of radiation hazard. An alternative is the fluence approach, whereby radiation hazard may be evaluated, at least in principle, via an appropriate action cross section. In order to compare these approaches, it may be useful to discuss th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006828

    authors: Waligórski MP

    更新日期:2002-01-01 00:00:00

  • Current challenges of full field digital mammography.

    abstract::Full field digital mammography (FFDM) has advantages over screen-film mammography (SFM), but some important challenges remain. The first challenge is related to the specific characteristics of FFDM. It remains unclear, which shape and limiting values of the modulation transfer function have the most influence on the p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci729

    authors: Van Ongeval C,Bosmans H,Van Steen A

    更新日期:2005-01-01 00:00:00

  • CABAS: a freely available PC program for fitting calibration curves in chromosome aberration dosimetry.

    abstract::The aim of biological dosimetry is to estimate the dose and the associated uncertainty to which an accident victim was exposed. This process requires the use of the maximum-likelihood method for fitting a calibration curve, a procedure that is not implemented in most statistical computer programs. Several laboratories...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm137

    authors: Deperas J,Szluinska M,Deperas-Kaminska M,Edwards A,Lloyd D,Lindholm C,Romm H,Roy L,Moss R,Morand J,Wojcik A

    更新日期:2007-01-01 00:00:00

  • Suppression methods of radon emanation from phosphorus fertiliser and diatomaceous earth.

    abstract::The present paper shows methods to suppress radon emanation from artificial porous materials such as phosphorous fertiliser or diatomaceous earth with a small amount of radium. The basic concept of suppression is making the radon emanation mechanism 'null', which comes from the fact that recoil is the main mechanism o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm420

    authors: Sasaki T,Gunji Y,Okuda T

    更新日期:2007-01-01 00:00:00

  • Correlation between thermoluminescence and mechanoluminescence of gamma-irradiated Dy activated potassium and magnesium mixed sulphate.

    abstract::Thermoluminescene (TL) and mechanoluminescence (ML) properties of gamma-irradiated Dy activated potassium and magnesium mixed sulphate have been studied. (K2Mg2:Dy) (SO4)3 samples having different concentrations of Dy were prepared by solid-state diffusion method. Two distinct peaks, the first approximately 130 degree...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci607

    authors: Kher RS,Panigrahi AK,Dhoble SJ,Khokhar MS

    更新日期:2006-01-01 00:00:00

  • Long-term measurements of radon equilibrium factor in Greek dwellings.

    abstract::The time variation of the radon equilibrium factor F was measured every four hours in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki (in northern Greece) during October 1998-April 1999. The time dependence of the mean weekly value of radon equilibrium factor F is relatively small. During...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006143

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • Modelling the energy-loss mechanism of charged particles in organic solids.

    abstract::The present study examines the energy-loss mechanism of charged particles in organic solids as determined by the inelastic interactions with the electronic sub-system of the target. The dielectric approach was applied to non-conducting valence electrons while an appropriate binary collision theory was used for core-el...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005836

    authors: Emfietzoglou D

    更新日期:2002-01-01 00:00:00

  • CAPABILITIES OF THE ARADOS-WG03 REGIONAL NETWORK FOR LARGE-SCALE RADIOLOGICAL AND NUCLEAR EMERGENCY SITUATIONS IN ASIA.

    abstract::In 2015, the Asian Radiation Dosimetry Group established a regional network of biological dosimetry laboratories known as the ARADOS-WG03 (Working Group 03; Biological Dosimetry). A survey was conducted in 2017 to evaluate the capabilities and capacities of the participating laboratories for emergency preparedness and...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy279

    authors: Jang S,Suto Y,Liu J,Liu Q,Zuo Y,Duy PN,Miura T,Abe Y,Hamasaki K,Suzuki K,Kodama S

    更新日期:2019-12-31 00:00:00

  • Investigations of thermoluminescence dosimetry in the Techa river flood plain: analysis of the new results.

    abstract::The Techa river region was highly contaminated due to radioactive releases from a nuclear production facility in the period from 1949 to 1956. The inhabitants of the upper Techa river settlements received significant doses of external radiation. The majority of the houses in the upper Techa river villages were demolis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005972

    authors: Bougrov NG,Baturin VA,Goeksu HY,Degteva MO,Jacob P

    更新日期:2002-01-01 00:00:00

  • Can the confidence in long range atmospheric transport models be increased? The pan-european experience of ensemble.

    abstract::Is atmospheric dispersion forecasting an important asset of the early-phase nuclear emergency response management? Is there a 'perfect atmospheric dispersion model'? Is there a way to make the results of dispersion models more reliable and trustworthy? While seeking to answer these questions the multi-model ensemble d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch261

    authors: Galmarini S,Bianconi R,Klug W,Mikkelsen T,Addis R,Andronopoulos S,Astrup P,Baklanov A,Bartniki J,Bartzis JC,Bellasio R,Bompay F,Buckley R,Bouzom M,Champion H,D'Amours R,Davakis E,Eleveld H,Geertsema GT,Glaab H,Kol

    更新日期:2004-01-01 00:00:00

  • PUBLIC HEALTH ENGLAND-CENTRE FOR RADIATION, CHEMICAL AND ENVIRONMENTAL HAZARDS (PHE-CRCE) EXTERNAL EXPERT EXPERIENCE IN THE JOINT EXTERNAL EVALUATION (JEE) MISSION FOR THE RADIATION EMERGENCIES TECHNICAL AREA.

    abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy142

    authors: de Ruvo A,Cox D

    更新日期:2018-12-01 00:00:00

  • High background radiation areas: the case of Villar de la Yegua village (Spain).

    abstract::The starting point of the Spanish experience in the study of High Background Radiation Areas is the development of a nationwide indoor radon survey carried out in 1988. This campaign, belonging to the first Spanish Radon Framework, consisted of approximately 2000 indoor radon measurements which represented a valuable ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm196

    authors: Sáinz C,Quindós LS,Fernández PL,Gómez J,Fuente I,Quindós L,Matarranz JL

    更新日期:2007-01-01 00:00:00

  • From films to thermoluminescence dosemeters: the Greek Atomic Energy Commission experience.

    abstract::The personnel dosimetry department of the Greek Atomic Energy Commission (GAEC) assures the individual monitoring of almost 8000 occupationally exposed workers. Thermoluminescence dosimetry systems will replace the existing photographic dosimetry system for the individual monitoring with the joint support of IAEA and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006582

    authors: Carinou E,Drikos G,Hourdakis C,Hyvönen H,Kamenopoulou V

    更新日期:2001-01-01 00:00:00

  • EFFECT OF PATIENT SIZE, ANATOMICAL LOCATION AND MODULATION STRENGTH ON DOSE DELIVERED AND IMAGE-QUALITY ON CT EXAMINATION.

    abstract::To study the effect of patient size, anatomical location and modulation strength (MS) on image-quality and delivered dose of CT scans acquired with automatic-exposure-control system (AEC). Four anthropomorphic phantoms (three paediatric and one thin adult) were studied, and normal and obese adults were simulated by pl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx055

    authors: Greffier J,Larbi A,Macri F,Beregi JP,Pereira F

    更新日期:2017-12-01 00:00:00

  • Electric and magnetic fields generated by ac power lines: an application of advanced modelling tools in order to predict exposure levels.

    abstract::In view of expected legislation changes imposing more severe limits on magnetic flux density, proposals are made based on theory and measurement for adjustment of Fower placement with regard to efficiency, cost and cost-benefit. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006689

    authors: Manco D,Bruzzi L,Soloni A,Valbonetti D,Fabbri S,Violanti S

    更新日期:2001-01-01 00:00:00

  • Study of the dosimetric characteristics of cosmic radiation at civil aviation altitudes.

    abstract::The dependence of the doses on solar activity for intermediate levels of the solar modulation parameter has been studied by means of simulations carried out by the Monte Carlo transport code FLUKA. The vertical cut-off rigidities investigated lie between 0.4 and 6.1 GV. The calculated results show that the linear depe...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006099

    authors: Ferrari A,Pellicioni M,Rancati T

    更新日期:2002-01-01 00:00:00

  • Monte Carlo calculations applied to the parametrical studies in a whole body counter.

    abstract::The use of a Monte Carlo code for the analysis and interpretation of whole body counting measurements is described. The sources of error are analysed and commented to show how a counting geometry can be improved by improving accuracy and precision in a measurement. The effects of body size, contamination distribution ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm242

    authors: Genicot JL,Koukouliou V,Carinou E

    更新日期:2008-01-01 00:00:00

  • A NEWLY DEVELOPED PHANTOM FOR PHYSICAL QUALITY ASSURANCE OF DENTAL CONE-BEAM COMPUTED TOMOGRAPHY.

    abstract::Two phantoms for a performance evaluation of cone-beam computed tomography (CBCT) were developed and their efficiency was tested. The first phantom, for low-contrast resolution, consisted of an acrylic circular plate with three 0.5-1.0 mm diameter rods. These rods enable the user to visually evaluate the limit of obse...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy116

    authors: Bamba J,Ishida H,Araki K

    更新日期:2019-05-01 00:00:00

  • Use of aspartame-based sweetener tablets in emergency dosimetry using EPR.

    abstract::Accident dosimetry aims to evaluate the unplanned radiation doses delivered to individuals through one of the objects exist in the area of the accident. The gamma dose response of free radicals generated in irradiated aspartame tablets and its usability for emergency dosimetry was studied. EPR spectra of unirradiated ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp293

    authors: Maghraby A,Salama E

    更新日期:2010-06-01 00:00:00

  • LiF:Mg,Cu,P glow curve shape dependence on heating rate.

    abstract::The glow curve shape of LiF:Mg,Cu,P (MCP) material is studied in this research. The study is focused on the effects of the heating rate on the dosimetric peaks. Different configurations of dosemeters (chips, cards and powder) are studied. The shifting of the dominant dosimetric peak is observed and analysed. The curve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci529

    authors: Luo LZ,Velbeck KJ,Moscovitch M,Rotunda JE

    更新日期:2006-01-01 00:00:00

  • Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation.

    abstract::In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiograp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr355

    authors: Paulo G,Santos J,Moreira A,Figueiredo F

    更新日期:2011-09-01 00:00:00

  • INFLUENCE OF STATIC ELECTRICITY ON RADON MEASUREMENT USING PASSIVE DETECTORS.

    abstract::In order to investigate the influence of the static electricity on the measurement using passive radon detector, detectors were charged at the surface of chamber and its CR-39 elements respectively on purpose before the exposure in this study. The results of in-chamber experiments revealed that the static electricity ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz067

    authors: Chen B,Zhao C,Fan D,Zhuo W

    更新日期:2019-10-01 00:00:00

  • Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital.

    abstract::Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibilit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq059

    authors: Johnsson AA,Vikgren J,Svalkvist A,Zachrisson S,Flinck A,Boijsen M,Kheddache S,Månsson LG,Båth M

    更新日期:2010-04-01 00:00:00

  • High patient doses in interventional cardiology due to physicians' negligence: how can they be prevented?

    abstract::Interventional cardiology procedures are usually associated with high patient doses and even deterministic radiation effects may occur. Expensive digital flat panels are preferably used to lower doses, and Athens General Hospital has recently installed one. However, this study shows that it is the cardiologists' pract...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn005

    authors: Mavrikou I,Kottou S,Tsapaki V,Neofotistou V

    更新日期:2008-01-01 00:00:00

  • EXPERIMENTAL VALIDATION OF ALGORITHMS USED TO ESTIMATE EFFECTIVE DOSE DURING INTERVENTIONAL RADIOLOGY PROCEDURES.

    abstract::In IR procedures, in order to evaluate the effective dose, the importance of the double dosemeter has been recognised, one worn above and one under the apron. Over the last few decades several algorithms have been developed to combine the readings of the dosemeters, however currently there is no international consensu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz136

    authors: Negri P,Campi F,De Crescenzo S,Garlati L,Tambussi O

    更新日期:2019-12-31 00:00:00

  • Methods and materials for the measurement of subjective and objective measurements of image quality.

    abstract::The evaluation of medical imaging systems may be performed using both subjective (e.g. high contrast limiting resolution, and low contrast detail detectability), and objective/physical (e.g. characteristic curve, signal-to-noise ratio, modulation transfer function, and Wiener spectra) indices of image quality. For the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006476

    authors: Marsh DM,Malone JF

    更新日期:2001-01-01 00:00:00

  • Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system.

    abstract::The dosimetric use of the chemical solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator thymolsulphonphthalein. On the basis of the CET solution, an accident and emergency personal dosemeter was designed allowing doses in the r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm042

    authors: Miljanić S,Razem D

    更新日期:2007-01-01 00:00:00

  • Spot measurements of intermediate frequency electric fields in the vicinity of compact fluorescent lamps.

    abstract::Starting in 2009, certain types of incandescent light bulbs will be withdrawn from the market in the European Union and elsewhere. However, compact fluorescent lamps that are among the candidates to replace them produce intermediate frequency electric fields (EFs) much higher than any other device or appliance previou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq276

    authors: Bakos J,Nagy N,Juhász P,Thuróczy G

    更新日期:2010-12-01 00:00:00

  • Activity concentrations and mean annual effective dose from gamma-emitting radionuclides in the Lebanese diet.

    abstract::Since the primary factor contributing to the internal effective dose in the human organism is contaminated food, the control of radionuclides in food represents the most important means of protection. This study was conducted to determine the levels of the dietary exposure of the Lebanese population to gamma-emitting ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn160

    authors: Nasreddine L,El Samad O,Hwalla N,Baydoun R,Hamzé M,Parent-Massin D

    更新日期:2008-01-01 00:00:00