Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital.

Abstract:

:Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibility studies, in which chest tomosynthesis and CT have been compared side-by side, have been used to determine the depiction potential of chest tomosynthesis. Comparisons with conventional chest radiography have been made. In the clinical setting, chest tomosynthesis has mostly been used as an additional examination. The most frequent indication for chest tomosynthesis has been suspicion of a nodule or tumour. In visibility studies, tomosynthesis has depicted over 90 % of the nodules seen on the CT scan. The corresponding figure for chest radiography has been <30 %. In the detection studies, the lesion-level sensitivity has been approximately 60 % for tomosynthesis and 20 % for chest radiography. In one of the detection studies, an analysis of all false-positive nodules was performed. This analysis showed that all findings had morphological correlates on the CT examinations. The majority of the false-positive nodules were localised in the immediate subpleural region. In conclusion, chest tomosynthesis is an improved chest radiography method, which can be used to optimise the use of CT resources, thereby reducing the radiation dose to the patient population. However, there are some limitations with chest tomosynthesis. For example, patients undergoing tomosynthesis have to be able to stand still and hold their breath firmly for 10 s. Also, chest tomosynthesis has a limited depth resolution, which may explain why pathology in the subpleural region is more difficult to interpret and artefacts from medical devices may occur.

journal_name

Radiat Prot Dosimetry

authors

Johnsson AA,Vikgren J,Svalkvist A,Zachrisson S,Flinck A,Boijsen M,Kheddache S,Månsson LG,Båth M

doi

10.1093/rpd/ncq059

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

124-9

issue

1-3

eissn

0144-8420

issn

1742-3406

pii

ncq059

journal_volume

139

pub_type

杂志文章
  • COVERING THE PATIENT'S ARM SUPPORT IN LEAD REDUCED THE RADIATION DOSE RATE TO THE CARDIOLOGISTS DURING PERCUTANEOUS CORONARY INTERVENTIONS: A PHANTOM STUDY.

    abstract::The aim of the study was to estimate organ dose rate reduction to a female anthropomorphic phantom, which simulated the cardiologist, during percutaneous coronary interventions (PCI) when the patient's arm support was covered with 0.4-mm lead foil. Organ dose rates were determined using five radiation detectors insert...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz292

    authors: Fukuda A,Lin PP

    更新日期:2020-06-24 00:00:00

  • Digital dual-parameter data acquisition for SP2 hydrogen-filled proportional counters.

    abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct262

    authors: Hawkes NP,Roberts NJ

    更新日期:2014-10-01 00:00:00

  • The role of retrapping in dose dependence of pulsed optically stimulated luminescence.

    abstract::Superlinear behaviour has been observed in dose dependence measurements of optically stimulated luminescence (OSL). Previous theoretical work has shown that superlinearity of the integral under the OSL decay curve may occur, resulting from competition with either radiationless luminescence centres or disconnected trap...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005938

    authors: Chen R

    更新日期:2002-01-01 00:00:00

  • Collaboration of local government and experts responding to increase in environmental radiation level due to the nuclear disaster: focusing on their activities and latest radiological discussion.

    abstract::Activities were introduced in Kashiwa city in the Tokyo metropolitan area to correspond to the elevated environmental radiation level after the disaster of the Fukushima Daiichi nuclear power plant. These were based on a strong cooperation between local governments and experts. Ambient dose rate and radioactivity of f...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv279

    authors: Iimoto T,Nunokawa J,Fujii H,Takashima R,Hashimoto M,Fukuhara T,Yajima T,Matsuzawa H,Kurosawa K,Yanagawa Y,Someya S

    更新日期:2015-11-01 00:00:00

  • Keeping up with the neighbours--measuring the bystander response.

    abstract::Ionising radiation can induce responses within non-exposed neighbouring (bystander) cells, which potentially have important implications on the estimates of risk at environmentally relevant doses. Using human skin fibroblasts (AG1522), a range of methods were used to investigate the nature of the signal(s) arising fro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl430

    authors: Pyke EL,Stevens DL,Hill MA

    更新日期:2006-01-01 00:00:00

  • Protection from radon exposure at home and at work in the directive 2013/59/Euratom.

    abstract::In recent years, international organisations involved in radiation protection and public health have produced new guidance, recommendations and requirements aiming better protection from radon exposure. These organisations have often worked in close collaboration in order to facilitate the establishment of harmonised ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu101

    authors: Bochicchio F

    更新日期:2014-07-01 00:00:00

  • Using simple mathematical functions to simulate pathological structures--input for digital mammography clinical trial.

    abstract::In this study a set of structures has been simulated to represent a range of clinically relevant breast cancer mammographic lesions including solid tumours and microcalcifications. All structures have been created using simple random-based mathematical functions and have been inserted into a subset of digital mammogra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch552

    authors: Ruschin M,Tingberg A,Båth M,Grahn A,Håkansson M,Hemdal B,Andersson I

    更新日期:2005-01-01 00:00:00

  • Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital.

    abstract::To assess the frequency of examination, image quality (IQ) and establishment of local diagnostic reference levels (LDRLs) in paediatric radiographic examinations. The X-ray device performance, film reject rate and IQ grading were assessed at Radiology Department of a referral and teaching children's hospital in Kenya....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs270

    authors: Wambani JS,Korir GK,Korir IK,Kilaha S

    更新日期:2013-05-01 00:00:00

  • Radiative models for the evaluation of the UV radiation at the ground.

    abstract::The variety of radiative models for solar UV radiation is discussed. For the evaluation of measured UV radiation at the ground the basic problem is the availability of actual values of the atmospheric parameters that influence the UV radiation. The largest uncertainties are due to clouds and aerosol, which are highly ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp211

    authors: Koepke P

    更新日期:2009-12-01 00:00:00

  • VALIDATION OF A BEAMNRC MONTE CARLO SIMULATION OF A BROAD BEAM DIAGNOSTIC X-RAY UNIT.

    abstract::A BEAMnrc Monte Carlo simulation of a diagnostic X-ray unit in a broad beam geometry intended for the derivation of effective linear attenuation coefficients was validated against measurements made on the X-ray unit on which the simulation was based. The validation process assessed the size of the beam, the first and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz032

    authors: Worrall M,Sutton DG

    更新日期:2019-12-31 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00

  • Natural radioactivity levels of geothermal waters and their influence on soil and agricultural activities.

    abstract::All over the world geothermal sources are used for different purposes. The contents of these waters are important to understand positive/negative effects on human life. In this study, natural radioactivity concentrations of geothermal waters were investigated to evaluate the effect on soils and agricultural activities...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct220

    authors: Murat Saç M,Aydemir S,Içhedef M,Kumru MN,Bolca M,Ozen F

    更新日期:2014-01-01 00:00:00

  • A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    abstract::Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw266

    authors: Bonin A,Tsilanizara A

    更新日期:2017-06-01 00:00:00

  • Luminescence dosimetry using building materials and personal objects.

    abstract::There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci699

    authors: Göksu HY,Bailiff IK

    更新日期:2006-01-01 00:00:00

  • Emission rate estimation through data assimilation of gamma dose measurements in a Lagrangian atmospheric dispersion model.

    abstract::This paper presents an efficient algorithm for estimating the unknown emission rate of radionuclides in the atmosphere following a nuclear accident. The algorithm is based on assimilation of gamma dose rate measured data in a Lagrangian atmospheric dispersion model. Such models are used in the framework of nuclear eme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq592

    authors: Tsiouri V,Kovalets I,Andronopoulos S,Bartzis JG

    更新日期:2012-01-01 00:00:00

  • Microdosimetric modelling of the response of thermoluminescence detectors to low- and high-LET ionising radiation.

    abstract::The microdosimetric one hit detector model was applied to calculate the dose response, energy response and relative thermoluminescence (TL) efficiency, eta, of high sensitive LiF:Mg,Cu,P and Al(2)O(3):C detectors after their irradiations by X rays, gamma rays, beta electrons and heavy charged particles (HCP). Microdos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl467

    authors: Olko P,Bilski P,Budzanowski M,Czopyk L,Swakon J,Waligorski MP

    更新日期:2006-01-01 00:00:00

  • Analysis of radon concentration in drinking water in Baoji (China) and the associated health effects.

    abstract::This paper presents the results of radon concentration measurements in drinking water from the municipal water supply system and private wells located in Baoji, China. The measurements were carried out on 69 samples. The mean values of tap water and well water were found to be 12 kBq m(-3) with a maximum of 18 kBq m(-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl048

    authors: Xinwei L

    更新日期:2006-01-01 00:00:00

  • Review of the correlation between results of cytogenetic dosimetry from blood lymphocytes and EPR dosimetry from tooth enamel for victims of radiation accidents.

    abstract::The goal of this study was to compare dose estimates from electron paramagnetic resonance (EPR) dosimetry with teeth and cytogenetic dosimetry with blood lymphocytes for 30 victims of radiation accidents. The whole-body exposures estimated by tooth enamel EPR dosimetry were ranging from 0.01 to 9.3 Gy. Study group com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu203

    authors: Khvostunov IK,Ivannikov AI,Skvortsov VG,Nugis VY,Golub EV

    更新日期:2015-03-01 00:00:00

  • Simultaneous measurements of indoor radon, radon-thoron progeny and high-resolution gamma spectrometry in Greek dwellings.

    abstract::Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci366

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2006-01-01 00:00:00

  • Assessments of medical exposures during interventional radiology procedures.

    abstract::This study aims to contribute to the construction of a scenario regarding patient radiation exposure in Brazilian interventional radiology, aiming to provide data for the future drafting of specific legislation on interventional radiology because there is currently a lack of safety regulations for haemodynamics servic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs172

    authors: Navarro VC,Navarro MV,Maia AF

    更新日期:2013-04-01 00:00:00

  • Development of a new thoron progeny detector based on SSNTD and the collection by an electric field.

    abstract::The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found between indoor thoron and its progeny, and the concentration of thoron progeny varies with time, it is necessary to develop detectors for long-term measurement that...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr078

    authors: Bi L,Tschiersch J,Meisenberg O,Wielunski M,Li JL,Shang B

    更新日期:2011-05-01 00:00:00

  • Comparison of results from quality control of physical parameters and results from clinical evaluation of mammographic images for the mammography screening facilities in Poland.

    abstract::The material for this study comprised control protocols from 248 mammography screening facilities, prepared by physicists employed at 16 Regional Coordinating Centres and the results from the clinical evaluation of mammographic images in 248 facilities in Poland. All mammograms were evaluated independently by three ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncr321

    authors: Fabiszewska E,Grabska I,Jankowska K,Wesolowska E,Bulski W

    更新日期:2011-09-01 00:00:00

  • CT equipment and performance issues: radiation protection 162.

    abstract::Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in pa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs285

    authors: Edyvean S

    更新日期:2013-02-01 00:00:00

  • High patient doses in interventional cardiology due to physicians' negligence: how can they be prevented?

    abstract::Interventional cardiology procedures are usually associated with high patient doses and even deterministic radiation effects may occur. Expensive digital flat panels are preferably used to lower doses, and Athens General Hospital has recently installed one. However, this study shows that it is the cardiologists' pract...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn005

    authors: Mavrikou I,Kottou S,Tsapaki V,Neofotistou V

    更新日期:2008-01-01 00:00:00

  • KINETIC SIMULATIONS OF THE THERMOLUMINESCENCE CHARACTERISTICS OF LiF:Mg, Ti INCORPORATING LOCALISED AND DELOCALISED RECOMBINATION.

    abstract::Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa209

    authors: Eliyahu I,Oster L

    更新日期:2021-01-13 00:00:00

  • Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project.

    abstract::The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in differen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq508

    authors: Domienik J,Brodecki M,Carinou E,Donadille L,Jankowski J,Koukorava C,Krim S,Nikodemova D,Ruiz-Lopez N,Sans-Mercé M,Struelens L,Vanhavere F

    更新日期:2011-03-01 00:00:00

  • Evaluation of the radioactivity of the pre-dominant gamma emitters in components used at high-energy proton accelerator facilities.

    abstract::At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl475

    authors: Numajiri M

    更新日期:2007-01-01 00:00:00

  • DYNAMIC RESPONSE OF CCD ARRAY SPECTRORADIOMETERS.

    abstract::A number of factors affect the measurements by charge coupled (CCD) array spectroradiometers, including stray light, dynamic response and ambient temperature. The departure from linearity was assessed for four CCD array spectroradiometers and linearity correction calculated with standard uncertainties error estimates....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv396

    authors: Baczynska KA,Price LL,Khazova M

    更新日期:2016-11-01 00:00:00

  • Why can't we find a better biological indicator of dose?

    abstract::The three general principles of the International Commission on Radiological Protection (ICRP) are: justification, optimisation (ALARA) and dose limitation. The principle application of optimisation (ALARA) for occupational exposures of workers or the public to external radiation is reliant on low doses being assessed...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch094

    authors: Voisin P,Roy L,Benderitter M

    更新日期:2004-01-01 00:00:00

  • High survival of frozen cells irradiated with gamma radiation.

    abstract::Cell storage in liquid nitrogen (LN) offers the most secure method of cell preservation even if cryopreserved cells are exposed to natural background of ionising radiation (IR). A lot of experiments have demonstrated that IR can induce damages in living cells, but only a little information regarding the response of cr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq541

    authors: Cugia G,Centis F,Del Zotto G,Lucarini A,Argazzi E,Zini G,Valentini M,Bono M,Picardi F,Stramigioli S,Cesarini W,Zamai L

    更新日期:2011-02-01 00:00:00