Digital dual-parameter data acquisition for SP2 hydrogen-filled proportional counters.

Abstract:

:Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal pulses, but the data acquisition system needed for this is complex to assemble and adjust if one uses conventional modular analogue electronics. In this work a digital sampling system, in conjunction with custom software, was used to measure and acquire amplitude and rise time data from type SP2 counters. The interpretation of the data was supported by a Monte Carlo calculation. The performance of the system is compared with that of a conventional 1-parameter analogue system, and the potential of the digital technique to supplant conventional methods is discussed.

journal_name

Radiat Prot Dosimetry

authors

Hawkes NP,Roberts NJ

doi

10.1093/rpd/nct262

subject

Has Abstract

pub_date

2014-10-01 00:00:00

pages

253-6

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

nct262

journal_volume

161

pub_type

杂志文章
  • Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory.

    abstract::The purpose of the study was to evaluate the dose performance of a flat-panel (FP) and an image intensifier (II) charge coupled device (CCD) digital fluoroscopy X-ray systems newly installed in an Interventional Cardiology (IC) department. Filter entrance dose rate, detector dose rate (during fluoroscopy) and filter e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch344

    authors: Tsapaki V,Kottou S,Kollaros N,Dafnomili P,Kyriakidis Z,Neofotistou V

    更新日期:2004-01-01 00:00:00

  • UNATTACHED 212PB FRACTION IN THE WORKER'S BREATHING ZONE AT HIGH THORON CONCENTRATIONS.

    abstract::Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa154

    authors: Zhukovsky M,Vasyanovich M,Onishchenko A

    更新日期:2020-11-27 00:00:00

  • EMRP project MetroMetal: selected results of ENVINET and CMI.

    abstract::Within the framework of the European Metrological Research Program (EMRP) IND04 MetroMetal 'Ionizing radiation metrology for the metallurgical industry', joint research carried out by 14 metrological institutions from countries within the European Union and the company ENVINET, questions concerning the determination o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu224

    authors: Tecl J,Solc J,Kovar P,Bunata M

    更新日期:2014-11-01 00:00:00

  • Radiation-induced non-targeted effects: some open questions.

    abstract::The existence of non-targeted effects (NTEs) of radiation (genomic instability and bystander effects) has been generally accepted for >20 y; however, there is research, which was largely ignored going back to 1915 reporting these effects. Despite today's general acceptance of the phenomenon of NTE, there is little agr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncv155

    authors: Mothersill C,Seymour C

    更新日期:2015-09-01 00:00:00

  • A new lead-free radiation shielding material for radiotherapy.

    abstract::Lead has recently been recognised as a source of environmental pollution, including the lead used for radiation shielding in radiotherapy. The bremsstrahlung radiation caused by the interaction between the electron beam and lead may reduce the accuracy of radiotherapy. To avoid the use of lead, a new material composed...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp053

    authors: Yue K,Luo W,Dong X,Wang C,Wu G,Jiang M,Zha Y

    更新日期:2009-02-01 00:00:00

  • Modelling of nuclear power plant decommissioning financing.

    abstract::Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv333

    authors: Bemš J,Knápek J,Králík T,Hejhal M,Kubančák J,Vašíček J

    更新日期:2015-06-01 00:00:00

  • Radon in Finnish apartment buildings.

    abstract::The 106 866 dwellings measured for radon in Finland so far by Radiation and Nuclear Safety Authority include 5560 apartments. The radon concentrations in ground-contact apartments are similar to those in low-rise residential buildings located in the same area. The values in apartments above the first floor do not sign...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs211

    authors: Valmari T,Arvela H,Reisbacka H

    更新日期:2012-11-01 00:00:00

  • EXPOSURE ASSESSMENT OF PORTABLE WIRELESS DEVICES ABOVE 6 GHz.

    abstract::The emerging 5 G wireless devices working at frequencies above 6 GHz are expected to have antenna arrays formed by dipoles, slots, patches or their combination. At lower frequencies, the accepted criteria for exposure compliance is stated in terms of specific absorption rate. IEEE and ICNIRP are adopting epithelial or...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy177

    authors: Carrasco E,Colombi D,Foster KR,Ziskin M,Balzano Q

    更新日期:2019-06-01 00:00:00

  • DETERMINATION OF NEUTRON EFFECTIVE DOSES IN WHOLE BODY POINT SOURCE EXPOSURES.

    abstract::The objective of this work is to obtain fluence to effective dose conversion coefficients for neutron point sources, using the GEANT4 toolkit. These calculations aim to investigate the aspects of neutron transport in the human body through Monte Carlo simulation using the International Commission on Radiological Prote...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx286

    authors: Ribeiro RM,Souza-Santos D

    更新日期:2018-08-01 00:00:00

  • Comparison of synchrotron radiation calculations between analytical codes (STAC8, photon) and Monte Carlo codes (FLUKA, EGS4).

    abstract::STAC8 is a significant improvement upon its predecessor PHOTON and is a valuable analytical code for quick and conservative beamline shielding designs for synchrotron radiation (SR) facilities. In order to check the applicability, accuracy and limitations of STAC8, studies were conducted to compare the results of STAC...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci207

    authors: Liu JC,Fasso A,Prinz A,Rokni S,Asano Y

    更新日期:2005-01-01 00:00:00

  • DEVELOPMENT OF A NATIONAL EMERGENCY PLAN FOR MEDICAL DIAGNOSTICS AND THERAPY OF DETERMINISTIC EFFECTS AFTER RADIATION ACCIDENTS.

    abstract::The focus of nuclear emergency planning in Austria has been so far on mitigating effects of widespread contamination (e.g. after NPP accidents); however, these plans did not contain provisions on the medical management of an acute radiation syndrome. To close this gap, a 'Medical Radiation Emergency Plan' was created ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw210

    authors: Ziegler A

    更新日期:2016-09-01 00:00:00

  • EVALUATION OF NEUTRON SCATTERING CORRECTION USING THE SEMI-EMPIRICAL METHOD AND THE SHADOW-CONE METHOD FOR THE NEUTRON FIELD OF THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE.

    abstract::When neutron survey metres are calibrated in neutron fields, the results for room- and air-scattered neutrons vary according to the distance from the source and the size, shape and construction of the neutron calibration room. ISO 8529-2 recommends four approaches for correcting these effects: the shadow-cone method, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx219

    authors: Lee SK,Kim SI,Lee J,Chang I,Kim JL,Kim H,Kim MC,Kim BH

    更新日期:2018-08-01 00:00:00

  • Simulation of 3D objects into breast tomosynthesis images.

    abstract::Digital breast tomosynthesis is a new three-dimensional (3D) breast-imaging modality that produces images of cross-sectional planes parallel to the detector plane from a limited number of X-ray projections over a limited angular range. Several technical and clinical parameters have not yet been completely optimised. S...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq084

    authors: Shaheen E,Zanca F,Sisini F,Zhang G,Jacobs J,Bosmans H

    更新日期:2010-04-01 00:00:00

  • Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital.

    abstract::The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch508

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • DEVELOPMENT OF A NEW SECONDARY STANDARD FOR H*(10).

    abstract::A secondary standard for ambient dose equivalent, H*(10), is necessary for the dissemination of the unit Sievert (Sv), but there is no such standard commercially available currently. Furthermore, the measurement of H*(10) instead of calculating H*(10) from air kerma and conversion coefficients is needed for unknown ra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz296

    authors: Bairlein K,Behnke B,Hupe O

    更新日期:2020-06-24 00:00:00

  • ISFSI site boundary radiation dose rate analyses.

    abstract::Across the globe nuclear utilities are in the process of designing and analysing Independent Spent Fuel Storage Installations (ISFSI) for the purpose of above ground spent-fuel storage primarily to mitigate the filling of spent-fuel pools. Using a conjoining of discrete ordinates transport theory (DORT) and Monte Carl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci279

    authors: Hagler RJ,Fero AH

    更新日期:2005-01-01 00:00:00

  • Design and fabrication of a multipurpose thyroid phantom for medical dosimetry and calibration.

    abstract::A multipurpose anthropomorphic neck phantom was designed and fabricated for use in medical applications. The designed neck phantom is composed of seven elliptic cylindrical slices with a semi-major axis of 14 cm and a semi-minor axis of 12.5 cm, each having the thickness of 2 cm. The thyroid gland, bony part of the ne...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv359

    authors: Mehdizadeh Naderi S,Sina S,Karimipoorfard M,Lotfalizadeh F,Entezarmahdi M,Moradi H,Faghihi R

    更新日期:2016-03-01 00:00:00

  • Influence of the uniformity of the slab phantom illumination on the calibration of personal dosemeters.

    abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq036

    authors: Ankerhold U,Ambrosi P

    更新日期:2010-06-01 00:00:00

  • Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

    abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch013

    authors: Jönsson H,Mattsson S

    更新日期:2004-01-01 00:00:00

  • OFF-SITE RADIOLOGICAL DOSE ASSESSMENT IN A SEVERE NUCLEAR ACCIDENT OF APR1400.

    abstract::Shin Kori unit 3 of Korea Hydro and Nuclear Power Co. is the pressurized water reactor of advanced power reactor 1400 (APR1400) in the Republic of Korea. A hypothetical accident was assumed for Shin Kori unit 3 to perform the time-dependent dose calculations along with the release rates of radionuclides to the environ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa105

    authors: Uddin GMB,Kim J

    更新日期:2020-09-16 00:00:00

  • Development of an electrolysis system for tritium enrichment in superficial water samples.

    abstract::Tritium present in the environment gradually decreased in the last decades and nowadays it has reached extremely low activity concentrations. The purpose of the present work is the implementation of a tritium enrichment system in water samples using electrolytic techniques and pure nickel and iron electrodes. In the p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp244

    authors: Garbarino G,Magnoni M,Bertino S,Losana MC

    更新日期:2009-12-01 00:00:00

  • Entrance surface, organ and effective doses for some of the patients undergoing different types of X ray procedures in Bangladesh.

    abstract::Entrance surface doses (ESDs) were measured for the most common types of X ray procedures, such as chest PA, lumber spine AP, lumber spine lateral, skull AP, skull lateral and pelvis AP in four major hospitals of Dhaka, the capital city of Bangladesh. Organ/tissue doses for 29 organs/tissues and effective doses for th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006549

    authors: Begum Z

    更新日期:2001-01-01 00:00:00

  • MODELLING THE INDOOR RADIATION DOSES: A REVIEW AND PERSPECTIVE.

    abstract::Theoretical models to calculate the indoor gamma and radon doses are reviewed, refined and applied. The model for gamma doses is built based on the relative effects of the different room elements that control the amount of radiation. The relative doses are calculated by the MCNP5 simulation software. The gamma sources...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncz008

    authors: Orabi M

    更新日期:2019-12-31 00:00:00

  • Evaluation of the radioactivity of the pre-dominant gamma emitters in components used at high-energy proton accelerator facilities.

    abstract::At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl475

    authors: Numajiri M

    更新日期:2007-01-01 00:00:00

  • Cytogenic investigations of serious overexposures to an industrial gamma radiography source.

    abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006090

    authors: Sevan'kaev AV,Lloyd DC,Edwards AA,Moquet JE,Nugis VY,Mikhailova GM,Potetnya OI,Khvostunov IK,Guskova AK,Baranov AE,Nadejina NM

    更新日期:2002-01-01 00:00:00

  • EPR properties of intact and deproteinated dentin.

    abstract::The effect of sample preparation on dentin electron paramagnetic resonance (EPR) spectra was investigated. The analysis was performed on dentin samples prepared by pure mechanical treatment or by an alkaline deproteination method. It was observed that (1) mechanical treatment induces both stable and transient signals,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci631

    authors: Fattibene P,Carosi A,De Coste V,Onori S

    更新日期:2006-01-01 00:00:00

  • Occurrence and Dose From Intake of Radon In Drinking Groundwater In Ogun State, Nigeria.

    abstract::Radon-222 concentrations in groundwater from 10 local government areas (LGAs) of Ogun State were measured using AlphaGUARD radon detector and AquaKIT. The mean activity concentration of radon ranged from 1.23 ± 0.21 to 12.68 ± 18.11 Bq.l-1 corresponding to geometric means (GMs) of 1.22- 6.39 Bq.l-1. The radon concentr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa221

    authors: Fatoki OO,Ademola JA

    更新日期:2021-02-03 00:00:00

  • Terrestrial gamma radioactivity levels and their corresponding extent exposure of environmental samples from Wadi El Assuity protective area, Assuit, Upper Egypt.

    abstract::Representative environmental samples (sandy soil, limestone, marble and gravels) collected from Wadi El Assuity, protective area, Assuit governorate in Upper Egypt have been investigated radiometrically using NaI (Tl) gamma-ray spectrometer. The specific activity of the radionuclides in Bq kg⁻¹ for soil ranged between...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq425

    authors: El-Taher A

    更新日期:2011-06-01 00:00:00

  • Relative implications of protective responses versus damage induction at low dose and low-dose-rate exposures, using the microdose approach.

    abstract::In reviewing the tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006197

    authors: Feinendegen LE

    更新日期:2003-01-01 00:00:00

  • Calibration of EPR signal dose response of tooth enamel to photons: experiment and Monte Carlo simulation.

    abstract::The experimental energy dependence of the electron paramagnetic resonance (EPR) radiation-induced signal at irradiation by photons in the energy range of 13 keV-1.25 MeV was analysed in terms of the absorbed dose in human tooth enamel. The latter was calculated using a Monte Carlo simulation of the photon and electron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch040

    authors: Ivannikov AI,Tikunov DD,Borysheva NB,Trompier F,Skvortsov VG,Stepanenko VF,Hoshi M

    更新日期:2004-01-01 00:00:00