Abstract:
:Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in the range 0.3-0.6. This effect is caused by local increase in air exchange near the inlet of the sampling device at high 220Rn concentrations. It was found that a dynamic shift between the unattached and attached thoron decay products is also observed in the worker's breathing zone at a high concentration of thoron. The 212Pb unattached fraction in worker's breathing zone was ~0.4. It demonstrates that when evaluating inhalation exposure to the products of the decay of thoron, it is necessary to take into account the increase of the 212Pb unattached fraction in the worker's breathing zone.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Zhukovsky M,Vasyanovich M,Onishchenko Adoi
10.1093/rpd/ncaa154subject
Has Abstractpub_date
2020-11-27 00:00:00pages
150-153issue
2eissn
0144-8420issn
1742-3406pii
5943969journal_volume
191pub_type
杂志文章abstract::The question arises as to whether radiation standards and guidelines set for adults are sufficiently protective of children. To answer this question, published literature values have been used to calculate radiation doses to children and adults from external and internal exposure to a suite of 30 radionuclides commonl...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq202
更新日期:2010-11-01 00:00:00
abstract::In order to determine the exposure to natural sources of radiation for people in the vicinity of remediated Hungarian uranium mine regional surveys were carried out. The surveys evaluated indoor radon concentrations and outdoor and indoor external gamma dose rates. Radon concentration has been measured with nuclear et...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci363
更新日期:2006-01-01 00:00:00
abstract::A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct323
更新日期:2014-10-01 00:00:00
abstract::In this paper the effect of treatment room and maze layout on the photoneutron and capture gamma dose equivalent in the maze was studied. MCNPX Monte Carlo (MC) code was used to simulate the Varian 2100 C/D Clinac 18 MV and four different room layouts. Two analytical methods, Wu-McGinley and McGinley, were used for do...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp303
更新日期:2010-08-01 00:00:00
abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch237
更新日期:2004-01-01 00:00:00
abstract::The Smith-Etherington extrathoracic (ET) clearance model has been developed to describe clearance from the human nasal passage as observed for 1.5, 3 and 6 microm monodisperse particles inhaled by participants while sitting or at light exercise. Model parameter values have been determined for 22 sets of nasal clearanc...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006205
更新日期:2003-01-01 00:00:00
abstract::This paper presents the results obtained for thoron concentration in 50 single-family dwellings in normal occupancy conditions (open house conditions), measured by a passive electret system (type E-PERM, SSTB configuration) in a 2001-2002 monitoring survey in the Metropolitan Zone of Mexico City. The results show the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch371
更新日期:2004-01-01 00:00:00
abstract::Gamma spectrometry of well water was done to measure the activity concentrations of gamma-emitters 226Ra and 228Ra from 238U and 232Th series, respectively, and 40K in their waters. Measurements were done using high-purity (HPGe) co-axial detectors (Canberra, GC 2018-7500 ) coupled to Canberra Multichannel Analyser sy...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm429
更新日期:2008-01-01 00:00:00
abstract::The electrochemical etching (ECE) method enlarges charged particle tracks to enhance its applications in particular in health physics and radiation dosimetry. The ECE method is usually based on using a high frequency-high voltage (HF-HV) generator with 250-µm-thick polycarbonate track detectors (PCTDs). The authors' r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu303
更新日期:2015-04-01 00:00:00
abstract::Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibilit...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq059
更新日期:2010-04-01 00:00:00
abstract::Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci366
更新日期:2006-01-01 00:00:00
abstract::The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in differen...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq508
更新日期:2011-03-01 00:00:00
abstract::The Organic Bound Tritium (OBT) amount in the body may induce changes in the evaluation of the internal exposure to tritium, due to its different retention time relative to HTO. OBT measurements for urine are not performed routinely, mainly because of the lengthy work needed in preparation of the samples, when using t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm148
更新日期:2007-01-01 00:00:00
abstract::The goal of this study was to develop a method to quantitatively assess the structural shielding performance of computed tomography (CT) rooms in Switzerland. The method was based on the comparison between calculated maximum allowed ambient dose rate (DR) and measured ambient DR in adjacent spaces. If the measured DR ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw131
更新日期:2017-04-25 00:00:00
abstract::The methods of the dark signal determination by direct contemporaneous measurements using a light spectrum and modelling of the dark signal based on the dark signal characterisation data were discussed. These techniques were tested with two charge-couple detectors (CCD) array spectroradiometers used in solar UVR measu...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu191
更新日期:2015-02-01 00:00:00
abstract::This article provides an assessment of the impact of global fallout on (137)Cs contamination in the bottom sediments of Kara Sea. The erosiveness of 10th-level river basins was estimated by landscape-geochemical and geomorphological characteristics. All 10th-level basins (n=154) were separated into three groups: mount...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs195
更新日期:2012-11-01 00:00:00
abstract::Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiose...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl545
更新日期:2007-01-01 00:00:00
abstract::Beginning in the 16th century, what was later found to be radon was thought to be causing sickness among miners. During the first decades of the 20th century, exposure to radon was seen as being healthy. During the 1940s, 1950s and 1960s researchers thought that the gamma radiation in residences could produce genetic ...
journal_title:Radiation protection dosimetry
pub_type: 历史文章,杂志文章,评审
doi:10.1093/rpd/nch318
更新日期:2004-01-01 00:00:00
abstract::Radon is one of the noble gases, which are chemically inert and do not make any reactants under normal conditions. In this experiment we demonstrated an enigmatic reaction between radon and fluorine when a corona discharge is used as a promoter. Distinctive changes in radon concentrations were caused by the discharge ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci311
更新日期:2005-01-01 00:00:00
abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct262
更新日期:2014-10-01 00:00:00
abstract::During the European Concerted Action SENTINEL 'Safety and Efficacy for New Techniques and Imaging using New Equipment to Support European Legislation', protocols for commissioning and constancy tests for dynamic digital flat detectors angiography units have been developed in order to harmonise practice among the Europ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,多中心研究
doi:10.1093/rpd/ncn016
更新日期:2008-01-01 00:00:00
abstract::Results of field tests with explosive dispersal of a radioactive substance (RaS) are presented. The paper deals with tests exploiting artificial obstacles as a continuation and expansion of the tests used in this study performed in free area described previously. The essential goal of the tests was to estimate the dis...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs209
更新日期:2013-04-01 00:00:00
abstract::Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr408
更新日期:2012-03-01 00:00:00
abstract::The outdoor gamma background of the historic center of Rome was studied by in situ measurements and average values of the outcropping geological formations. The survey resulted in two maps of dose equivalent rate, related to pre-anthropic and present conditions. Presently, the average of the dose equivalent rate from ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz247
更新日期:2019-12-31 00:00:00
abstract::In radiotherapy involving thermal and epithermal neutrons, the knowledge of dose distributions, with separation of the contribution of each secondary radiation component, is of utmost importance. Layers of Fricke-Xylenol-Orange-infused gel dosemeters give the possibility of achieving such requirements because, owing t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci625
更新日期:2006-01-01 00:00:00
abstract::Monitoring of radon in underground mines is important in order to assess the radiological hazards to occupational workers. Radon concentration levels in three underground lignite mines (Tunçbilek, Omerler and Eynez) of Turkey were obtained in this study. For this reason, atmospheric radon level measurements were carri...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp179
更新日期:2010-01-01 00:00:00
abstract::The European Basic Safety Standards demand the prediction of areas where a significant number of households exceed the reference level for the radon activity concentration. Therefore, radon maps are established which are based on indoor and soil gas measurements. In this study results of soil gas measurements are inte...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx141
更新日期:2017-11-01 00:00:00
abstract::Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10-400 GeV. The target organs considered were right eye, thyroid,...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006556
更新日期:2001-01-01 00:00:00
abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct136
更新日期:2013-12-01 00:00:00
abstract::Doses in radiology should be as low as reasonably achievable. In order to compare practice in different centres it is necessary to compare patient doses. This can only be undertaken if dosimetry studies are similar. In order to facilitate comparisons, the DIMOND consortium developed a patient dosimetry protocol. Refer...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci715
更新日期:2005-01-01 00:00:00