Abstract:
:Gamma spectrometry of well water was done to measure the activity concentrations of gamma-emitters 226Ra and 228Ra from 238U and 232Th series, respectively, and 40K in their waters. Measurements were done using high-purity (HPGe) co-axial detectors (Canberra, GC 2018-7500 ) coupled to Canberra Multichannel Analyser system. Activity concentrations ranged from 0.57 to 26.86, 0.20 to 60.06 and 0.35 to 29.01 Bq l(-1) for 226Ra, 228Ra and 40K, respectively. Activity concentrations were compared with data from other parts of the world and used to estimate annual effective dose for three age groups. Total annual effective doses from the intake of these radionuclides in the waters ranged from 0.02 to 76.84, 0.02 to 38.80 and 0.05 to 481.60 mSv y(-1) for age group <1, 2-7 and > or =17 y, respectively. These values are considerably higher than both the World Health Organisation and the International Commission on Radiological Protection limits.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Ajayi OS,Owolabi TPdoi
10.1093/rpd/ncm429subject
Has Abstractpub_date
2008-01-01 00:00:00pages
477-84issue
4eissn
0144-8420issn
1742-3406pii
ncm429journal_volume
128pub_type
杂志文章abstract::Production of double strand breaks (DSBs) and double-stranded DNA fragments after irradiation with high energy nitrogen ions was simulated with stochastic track generation and a high-order chromatin structure (HOCS) model representing a segment of interphase chromosome. The non-random distribution of DNA fragments is ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006748
更新日期:2002-01-01 00:00:00
abstract::In response to reactive oxygen species (ROS) or electrophiles, the transcription factor nuclear factor-erythroid 2 (NF-E2)-related factor 2 (Nrf2) rapidly translocates into the nucleus and induces the expression of various antioxidant genes, such as heme oxygenase-1 (HO-1). Low linear energy transfer (LET) ionising ra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs201
更新日期:2012-11-01 00:00:00
abstract::To study the radiation environment inside the International Space Station, solid state nuclear track detector stacks were used. Within the BRADOS experiments, Phase 1, seven stacks were exposed at different locations of the Russian segment 'Zvezda' for 248 days in 2001. It was supposed that the radiation field inside ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci673
更新日期:2006-01-01 00:00:00
abstract::The natural radionuclide contents of some concrete building blocks randomly sampled in the city of Ibadan have been determined using NaI(Tl) gamma ray spectrometry. The radionuclides 226Ra, 232Th and 40K were determined with city mean specific activities 47 +/- 21 Bq.kg-1, 52 +/- 21 Bq.kg-1, and 352 +/- 222 Bq.kg-1, r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006527
更新日期:2001-01-01 00:00:00
abstract::A module for proton track structure simulation in liquid water was implemented in the biophysical model PARTRAC. Simulated tracks of energy deposition events from the radiation under investigation were superimposed on a higher-order DNA target model describing the whole genome inside a human cell. The parameters contr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006848
更新日期:2002-01-01 00:00:00
abstract::There is a growing public awareness of the risk of accidental radiation exposure due to ageing nuclear power installations, illegal dumping of nuclear waste and terrorist activities, and of the consequential health risks to populations in addition to social and economic disturbance extending beyond national boundaries...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci699
更新日期:2006-01-01 00:00:00
abstract::The occupational radiation exposure of medical radiation workers at the Institute of Oncology, Vilnius University (IOVU) was analysed. Quartile dose measurements were collected and routinely analysed for a period of 8 y from 1 January 2004 to 31 December 2011. A total of 193 medical radiation workers were monitored, c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct111
更新日期:2013-11-01 00:00:00
abstract::Instead of conventional Ge semiconductor detectors and NaI(Tl) scintillation spectrometers, an application of a CdZnTe semiconductor (CZT) whose crystal has the dimension of 1 cm cubic to the in situ environmental radioactivity measurement was attempted in deeply affected areas in Fukushima region. Results of depositi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv277
更新日期:2015-11-01 00:00:00
abstract::The Organic Bound Tritium (OBT) amount in the body may induce changes in the evaluation of the internal exposure to tritium, due to its different retention time relative to HTO. OBT measurements for urine are not performed routinely, mainly because of the lengthy work needed in preparation of the samples, when using t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm148
更新日期:2007-01-01 00:00:00
abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz224
更新日期:2019-12-31 00:00:00
abstract::Human exploration of the solar system beyond Earth's orbit will entail many risks for the crew on these deep space missions. One of the most significant health risks is exposure to the harsh space radiation environment beyond the protection provided by the Earth's intrinsic magnetic field. Crew on exploration missions...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci141
更新日期:2005-01-01 00:00:00
abstract::The results of experimental studies performed in a radiotherapy (12)C ion beam with a nominal energy of 500 MeV/amu and in (16)O and (56)Fe ion beams with a nominal energy of 1 GeV/amu have been described. Linear energy transfer (LET) spectra have been established by means of an LET spectrometer based on a chemically ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm133
更新日期:2007-01-01 00:00:00
abstract::The E. coli catabolite gene activator protein (CAP)-DNA complex with 125I located at the position of the H5 atom of the cytosine near the centre was incorporated into the PARTRAC track structure code. DNA strand breaks due to irradiation were calculated by track structure and radical attack simulations; strand breaks ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006738
更新日期:2002-01-01 00:00:00
abstract::An international programme of work is currently under way to develop methods for calculating doses to infants from ingestion of radionuclides present in mothers' milk. This paper considers the special case of the alkaline earth elements. Models have been developed for 45Ca, 90Sr and 226Ra and the sensitivity of result...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006239
更新日期:2003-01-01 00:00:00
abstract::The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminesce...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw100
更新日期:2017-04-20 00:00:00
abstract::In radiotherapy with carbon ions, biological effects of treatments have to be predicted. For this purpose, one of the most used models is the local effect model (LEM) developed at the Gesellschaft für Schwerionenforschung (GSI), Germany. At the Istituto Nazionale di Fisica Nucleare, Italy, the reliability of the last ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq407
更新日期:2011-02-01 00:00:00
abstract::Occupational radiological protection (RP) is still a challenge in several clinical practices. ICRP has included specific recommendations and advice for occupational protection in most of the documents published in recent years and its current programme of work includes the preparation of documents with specific conten...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu354
更新日期:2015-04-01 00:00:00
abstract::On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of (131)I. Radiation doses for the designated caregivers were ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl084
更新日期:2007-01-01 00:00:00
abstract::The paper deals with the physical skull phantoms Bundesinstitut fuer Strahlenschutz and BPAM-001, which are used in order to calibrate in vivo detection systems for estimation of (241)Am activity in the skeleton. Their voxel models were made and used in the Monte Carlo simulations. The results of the simulation were c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq491
更新日期:2011-03-01 00:00:00
abstract::Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women i...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006733
更新日期:2002-01-01 00:00:00
abstract::The objective of this work is to obtain fluence to effective dose conversion coefficients for neutron point sources, using the GEANT4 toolkit. These calculations aim to investigate the aspects of neutron transport in the human body through Monte Carlo simulation using the International Commission on Radiological Prote...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx286
更新日期:2018-08-01 00:00:00
abstract::Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibilit...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq059
更新日期:2010-04-01 00:00:00
abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl128
更新日期:2007-01-01 00:00:00
abstract::Measurements were made according to IEEE standard 644-1994 at a height of 1 m above floor level. It is concluded that none of the measurements exceeded the ACGIH threshold limit value. Among all control rooms the highest measured density amount is 0.69 μT in the control room of Ozgol substation and the lowest is 0.2 μ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq445
更新日期:2011-06-01 00:00:00
abstract::This paper presents the values of radon and thoron progeny concentrations for different seasons in the dwellings of Tehri Garhwal, India. The measurements have been carried out using LR-115 solid-state nuclear track detector-based passive time-integrated direct thoron progeny sensor/direct radon progeny sensor techniq...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv224
更新日期:2015-11-01 00:00:00
abstract::During the operation of research facilities at Research Centre Jülich, Germany, nuclear waste is stored in drums and other vessels in an interim storage building on-site, which has a concrete shielding at the side walls. Owing to the lack of a well-defined source, measured gamma spectra were unfolded to determine the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci185
更新日期:2005-01-01 00:00:00
abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006090
更新日期:2002-01-01 00:00:00
abstract::A comparison is presented of particular methods of exposure in the first year after the Chernobyl disaster and ten years later. This comparison shows that the population exposure due to the presence of radiocaesium in the environment results from the presence of caesium contained in the soil, which provides 68% of the...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006725
更新日期:2002-01-01 00:00:00
abstract::The design and dosimetry of a novel in vitro radon irradiation facility to investigate cytogenetic damage induced by radon and progeny is described. The system offers a 4pi geometry for uniform irradiation, proving a versatile and convenient facility for irradiation of whole blood cells in suspension or media. Doses c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn060
更新日期:2008-01-01 00:00:00
abstract::The aim of this work is to calculate the absorbed dose to matter due to neutrons in the 5-150 MeV energy range. Materials involved in the calculations are Al2O3, CaSO4 and CaS, which may be used as dosemeters and have already been studied for their luminescent properties. The absorbed dose is assumed to be mainly due ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch147
更新日期:2004-01-01 00:00:00