Analysis of the reliability of the local effect model for the use in carbon ion treatment planning systems.

Abstract:

:In radiotherapy with carbon ions, biological effects of treatments have to be predicted. For this purpose, one of the most used models is the local effect model (LEM) developed at the Gesellschaft für Schwerionenforschung (GSI), Germany. At the Istituto Nazionale di Fisica Nucleare, Italy, the reliability of the last published version of LEM (LEM III) in reproducing radiobiological data has been checked under both monoenergetic and spread-out Bragg peak (SOBP) carbon-ion irradiation. The reproduction of the monoenergetic measurements with the LEM was rather successful for some cell lines, while it failed for the less-radioresistant ones. The SOBP experimental trend was predicted by the LEM, but a large shift between model curves and measured points was observed.

journal_name

Radiat Prot Dosimetry

authors

Russo G,Attili A,Bourhaleb F,Marchetto F,Peroni C,Schmitt E,Bertrand D

doi

10.1093/rpd/ncq407

subject

Has Abstract

pub_date

2011-02-01 00:00:00

pages

497-502

issue

2-4

eissn

0144-8420

issn

1742-3406

pii

ncq407

journal_volume

143

pub_type

杂志文章
  • 1800 MHz in vitro exposure device for experimental studies on the effects of mobile communication systems.

    abstract::A wire patch cell (WPC) operating at the uplink frequency band of GSM 1800 MHz has been designed for in vitro experiments with the aim of investigating the possible biological effects of electromagnetic radiation associated with cellular phones. The 1800 MHz WPC design is a direct descendant of the original 900 MHz WP...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch414

    authors: Ardoino L,Lopresto V,Mancini S,Pinto R,Lovisolo GA

    更新日期:2004-01-01 00:00:00

  • ISO 4037:2019 VALIDATION OF RADIATION QUALITIES BY MEANS OF HALF-VALUE LAYER AND HP(10) DOSIMETRY.

    abstract::Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updated ISO 4037:2019 standard. As the ISO 4037 contains a somewhat vague d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz185

    authors: Bandalo V,Greiter MB,Brönner J,Hoedlmoser H

    更新日期:2019-12-31 00:00:00

  • RADIOACTIVE REMEDIATION OF AQUATIC ECOSYSTEMS USING MICROALGAE.

    abstract::Radionuclides that have entered the environment through nuclear weapon tests, nuclear accidents or other human activities represent an ecological hazard. Many decontamination techniques are technically and financially demanding and often not environmentally beneficial. A suitable alternative is bioremediation techniqu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz221

    authors: Galanda D,Tatarová D,Kuruc J,Gaálová B,Slimáková J

    更新日期:2019-12-31 00:00:00

  • Hp(3)/Φ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens.

    abstract::The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct246

    authors: Ferrari P,Gualdrini G,Tanner R,Fantuzzi E

    更新日期:2014-10-01 00:00:00

  • Patient dosimetry in nuclear medicine.

    abstract::In diagnostic nuclear medicine, the biokinetics of the radiopharmaceutical (actually of the radionuclide) is determined for a number of representative patients. At therapy, it is essential to determine the patient's individual biokinetics of the radiopharmaceutical in order to calculate the absorbed doses to critical ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv061

    authors: Mattsson S

    更新日期:2015-07-01 00:00:00

  • Response of silicon diode dosemeters to scattered radiation from megavoltage photon beams.

    abstract::Dose response effects of diodes due to the high atomic number of silicon relative to water are investigated. While quality chances in the primary component of a megavoltage beam with depth are minimal. Compton scattered photons are shown to have a substantial effect on the quality leading to their enhanced absorption ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006014

    authors: Yin Z,Hugtenburg RP,Beddoe AH

    更新日期:2002-01-01 00:00:00

  • Review of retrospective dosimetry techniques for external ionising radiation exposures.

    abstract::The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by indivi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncq499

    authors: Ainsbury EA,Bakhanova E,Barquinero JF,Brai M,Chumak V,Correcher V,Darroudi F,Fattibene P,Gruel G,Guclu I,Horn S,Jaworska A,Kulka U,Lindholm C,Lloyd D,Longo A,Marrale M,Monteiro Gil O,Oestreicher U,Pajic J,Rakic B

    更新日期:2011-11-01 00:00:00

  • Quality control and reliability of reported doses.

    abstract::Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch287

    authors: Stadtmann H,Figel M,Kamenopoulou V,Kluszczynski D,Roed H,Van Dijk J

    更新日期:2004-01-01 00:00:00

  • Comparative analysis between radiation doses obtained by EPR dosimetry using tooth enamel and established analytical methods for the population of radioactively contaminated territories.

    abstract::A comparative analysis of radiation doses determined by tooth enamel electron paramagnetic resonance (EPR) spectroscopy and by an acknowledged analytical method is performed for individual doses and for average doses in population of some settlements of the Bryansk region (Russia), which have been contaminated after t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu132

    authors: Ivannikov AI,Skvortsov VG,Stepanenko VF,Zhumadilov KSh

    更新日期:2014-06-01 00:00:00

  • A family of statistical distributions for modelling occupational radiation doses in low dose occupations.

    abstract::New statistical distributions have been defined to describe occupational exposures to ionising radiation. These distributions are particularly useful in modelling occupations where most doses are low. The maximum likelihood method was used for parameter estimation and has been adapted to allow doses that are recorded ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl045

    authors: Sont WN

    更新日期:2006-01-01 00:00:00

  • On the equivalence of propane-based tissue-equivalent gas and liquid water with respect to the ionisation-yield formation by electrons and alpha-particles.

    abstract::One encouraging way, at present, to put the investigation of ionisation-yield formation in sub-cellular structures or, at least, in nanometric volumes of liquid water on an experimental basis is the use of highly sophisticated counters filled with gases at low operating pressure to simulate target volumes a few nm in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006818

    authors: Grosswendt B

    更新日期:2002-01-01 00:00:00

  • Dose trends in occupational radiation exposure in Europe results from the ESOREX project.

    abstract::The ESOREX project was initiated in 1997 by the EC DG TREN and it was executed by the BfS/Germany in close co-operation with the State Office for Nuclear Safety/Czech Republic). It consists of surveys on radiation monitoring and exposure carried out in the 30 European states. The study provides comparable descriptions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl566

    authors: Frasch G,Petrová K

    更新日期:2007-01-01 00:00:00

  • LiF:Mg,Cu,P glow curve shape dependence on heating rate.

    abstract::The glow curve shape of LiF:Mg,Cu,P (MCP) material is studied in this research. The study is focused on the effects of the heating rate on the dosimetric peaks. Different configurations of dosemeters (chips, cards and powder) are studied. The shifting of the dominant dosimetric peak is observed and analysed. The curve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci529

    authors: Luo LZ,Velbeck KJ,Moscovitch M,Rotunda JE

    更新日期:2006-01-01 00:00:00

  • The influence of caesium-137 distribution in Poland's north-eastern ecosystem on effective dose 10 years after the Chernobyl disaster.

    abstract::A comparison is presented of particular methods of exposure in the first year after the Chernobyl disaster and ten years later. This comparison shows that the population exposure due to the presence of radiocaesium in the environment results from the presence of caesium contained in the soil, which provides 68% of the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006725

    authors: Zalewski M,Kapala J,Tomczak M

    更新日期:2002-01-01 00:00:00

  • Protocols for dosimetry and patient reference levels.

    abstract::Doses in radiology should be as low as reasonably achievable. In order to compare practice in different centres it is necessary to compare patient doses. This can only be undertaken if dosimetry studies are similar. In order to facilitate comparisons, the DIMOND consortium developed a patient dosimetry protocol. Refer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci715

    authors: Faulkner K

    更新日期:2005-01-01 00:00:00

  • BAYESIAN SPECTRUM DECONVOLUTION INCLUDING UNCERTAINTIES AND MODEL SELECTION: APPLICATION TO X-RAY EMISSION DATA USING WINBUGS.

    abstract::Spectrum deconvolution is an important task in ionizing radiation measurements, as the pulse height spectra, or, in general, the measured data from spectrometers or other measuring instruments are usually determined by the convolution of the response function with the fluence spectra. The method presented here for obt...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy286

    authors: Behrens R,Reginatto M

    更新日期:2019-12-23 00:00:00

  • EDDIX--a database of ionisation double differential cross sections.

    abstract::The use of Monte Carlo track structure is a choice method in biophysical modelling and calculations. To precisely model 3D and 4D tracks, the cross section for the ionisation by an incoming ion, double differential in the outgoing electron energy and angle, is required. However, the double differential cross section c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq397

    authors: MacGibbon JH,Emerson S,Liamsuwan T,Nikjoo H

    更新日期:2011-02-01 00:00:00

  • Survey of patient dose in computed tomography in Syria 2009.

    abstract::The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq155

    authors: Kharita MH,Khazzam S

    更新日期:2010-09-01 00:00:00

  • Ethical issues in radiology: perspectives from the Christian tradition.

    abstract::The Christian ethical tradition introduces a number of key values into the clinical context. Moreover, although some denominational differences exist, these are essentially differences of emphasis rather than of substance. Among the central values which the Christian tradition promotes are: the dignity of the person, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp044

    authors: Hogan L

    更新日期:2009-07-01 00:00:00

  • Determination of the dose to persons assisting when X-radiation is used in medicine, dentistry and veterinary medicine.

    abstract::During medical X-ray examinations of patients, humans as well as animals, voluntarily assisting persons are frequently needed in order to calm down the patient or animal. Typical exposure situations have been identified and measurements were performed in the fields of scattered X-rays. The personal dose equivalent H(p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq351

    authors: Hupe O,Ankerhold U

    更新日期:2011-03-01 00:00:00

  • Specific features of the influence of high-energy electron beams on the luminescent properties of undoped and Nb, Fe-doped Al₂O₃ crystals.

    abstract::The influence of 10 MeV high-current electron beams accelerated by the M-30 microtron on the luminescent properties of the α-Al₂O₃, Al₂O₃:Nb and Al₂O₃:Fe crystals has been studied. The effect of the long-term phosphorescence at room temperature has been found that can be used to monitor electron and gamma accelerator ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu213

    authors: Maslyuk VT,Megela IG,Okunieva TO,Pekar JM,Pekar VJ

    更新日期:2014-11-01 00:00:00

  • Determination of a neutron source position in an unknown homogeneous medium; the 2D case.

    abstract::The localisation of an unknown neutron source in various bulky homogeneous media was studied. For the planar case two (3)He detectors on the opposite faces of a box were used. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm048

    authors: Dubinski S,Presler O,Alfassi ZB

    更新日期:2007-01-01 00:00:00

  • In vivo thyroid 131I monitoring system using an imaging plate.

    abstract::The counting efficiency and detection limit of an in vivo thyroid 131I monitoring system using an imaging plate (IP) were estimated using an anthropomorphic thyroid neck phantom. The counting efficiency of the IP system was approximately constant for thyroid volumes between 11.7 and 20 ml and neck diameters between 10...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006025

    authors: Hirota M,Saze T,Nishizawa K

    更新日期:2002-01-01 00:00:00

  • Exposure estimates based on broadband ELF magnetic field measurements versus the ICNIRP multiple frequency rule.

    abstract::The evaluation of exposure to extremely low-frequency (ELF) magnetic fields using broadband measurement techniques gives satisfactory results when the field has essentially a single frequency. Nevertheless, magnetic fields are in most cases distorted by harmonic components. This work analyses the harmonic components o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu175

    authors: Paniagua JM,Rufo M,Jiménez A,Pachón FT,Carrero J

    更新日期:2015-02-01 00:00:00

  • Radioactivity monitoring in ground level air in Belgrade urban area.

    abstract::Concentrations of beryllium-7 ((7)Be), lead-210 ((210)Pb) and caesium-137 ((137)Cs) were measured at two sites in the city of Belgrade (Serbia). One monitoring site was located in the central city area with heavy traffic and the other within the Institute of Nuclear Sciences Vinca, in the suburbs. Presented data cover...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq211

    authors: Todorovic D,Popovic D,Nikolic J,Ajtic J

    更新日期:2010-12-01 00:00:00

  • Deformation luminescence produced during application and release of pressure on to gamma-irradiated CaF2:RE crystals.

    abstract::Calcium fluoride CaF2 is an interesting host lattice for rare earth (RE) activators. CaF2 crystals doped with different concentrations of Dy, Ce, Er and Gd have been grown by the Bridgman technique and their deformation luminescence (DL) induced by room temperature gamma irradiation has been recorded. When a uniaxial ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci606

    authors: Kher RS,Brahme N,Banerjee M,Dhoble SJ,Khokhar MS

    更新日期:2006-01-01 00:00:00

  • Would children be adequately protected by existing intervention levels during a radionuclear emergency?

    abstract::The question arises as to whether radiation standards and guidelines set for adults are sufficiently protective of children. To answer this question, published literature values have been used to calculate radiation doses to children and adults from external and internal exposure to a suite of 30 radionuclides commonl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq202

    authors: Tracy BL

    更新日期:2010-11-01 00:00:00

  • Transfer of alkaline earth elements in mothers' milk and doses from 45Ca, 90Sr and 226Ra.

    abstract::An international programme of work is currently under way to develop methods for calculating doses to infants from ingestion of radionuclides present in mothers' milk. This paper considers the special case of the alkaline earth elements. Models have been developed for 45Ca, 90Sr and 226Ra and the sensitivity of result...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006239

    authors: Smith TJ,Phipps AW,Fell TP,Harrison JD

    更新日期:2003-01-01 00:00:00

  • Measurements of radon concentrations in waters and soil gas of Zonguldak, Turkey.

    abstract::The radon concentrations in soil-gas and water samples (in the form of springs, catchment, tap, thermal) used as drinking water or thermal were measured using a professional radon monitor AlphaGUARD PQ 2000PRO. The measured radon concentrations in water samples ranged from 0.32 to 88.22 Bq l(-1). Most of radon levels ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct308

    authors: Koray A,Akkaya G,Kahraman A,Kaynak G

    更新日期:2014-12-01 00:00:00

  • Assessment of gamma dose rates in air in Adana/Turkey.

    abstract::This study assesses the outdoor gamma absorbed dose levels in air of the Adana's region. The measurements were taken from 130 different sample points in this area by Eberline Smart Portable (ESP-2) with SPA-6 plastic scintillation detector. The outdoor gamma absorbed dose rates order from 40 to 145 nGy h(-1). Average ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn295

    authors: Degerlier M,Ozger G