Abstract:
:Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the evaluation or data management system, damage of the dosemeter itself or by the loss of dosemeter. In this article, an attempt is made to estimate the importance of the above-mentioned conditions. This is achieved by sending questionnaires to about 200 approved dosimetric services in Europe. In total 88 questionnaires were returned and analysed. In the questionnaires, the frequency of occurrence of the various error conditions were investigated. Participants were also asked to evaluate the impact of the error condition from a dosimetric point of view and what countermeasures are taken. The article summarises all responses and compares different sources of errors according to their impact on the uncertainty of the resulting dose and gives a comprehensive overview on quality control actions and reliability on reported doses from European dosimetric services.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Stadtmann H,Figel M,Kamenopoulou V,Kluszczynski D,Roed H,Van Dijk Jdoi
10.1093/rpd/nch287keywords:
subject
Has Abstractpub_date
2004-01-01 00:00:00pages
169-89issue
1eissn
0144-8420issn
1742-3406pii
112/1/169journal_volume
112pub_type
杂志文章abstract::Major contaminants from venting and hydrogen explosions at the Fukushima Daiichi nuclear reactors between 12 and 15 March 2011 were transported northwestward and deposited on soil and plants via precipitation. Surface soils and plant leaves were sampled at 64 sites in the Fukushima Prefecture. The highest concentratio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs222
更新日期:2012-11-01 00:00:00
abstract::During the European Concerted Action SENTINEL 'Safety and Efficacy for New Techniques and Imaging using New Equipment to Support European Legislation', protocols for commissioning and constancy tests for dynamic digital flat detectors angiography units have been developed in order to harmonise practice among the Europ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,多中心研究
doi:10.1093/rpd/ncn016
更新日期:2008-01-01 00:00:00
abstract::The accreditation of the Competent Incorporation Measuring Body at Jülich includes incorporation monitoring by means of direct measurements of the body activity as well as by means of indirect determination of the body activity by radiochemical analysis of excreta samples. In both testing areas, it proved to be very u...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq360
更新日期:2011-03-01 00:00:00
abstract::Anthropomorphic phantoms are used in nuclear medicine for imaging quality control, calibration of gamma spectrometry system for the study of internal contamination with radionuclides and for internal dosimetric studies. These are constructed of materials that have radiation attenuation coefficients similar to those of...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu022
更新日期:2014-12-01 00:00:00
abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx244
更新日期:2018-08-01 00:00:00
abstract::Doses received by Cuban population due to exposure to the environmental sources of radiation were studied for their evaluation. Estimations of doses from the different components of the total dose were obtained and published. From the results obtained estimations of total doses to Cuban population from environmental r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl092
更新日期:2007-01-01 00:00:00
abstract::We applied circular dichroism (CD) spectral analysis to obtain the secondary structure of the DNA repair protein XRCC4, with a focus on its C-terminus. Using synchrotron radiation as a light source across a wide range of wavelengths, including vacuum ultraviolet (UV) light from 180 to 200 nm and UV light from 200 to 2...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy275
更新日期:2019-05-01 00:00:00
abstract::A new method was developed to determine HT deposition velocity and to investigate how environmental factors affect the deposition processes including the diffusion into soil and the biochemical conversion by microorganisms to HTO in soil. This method, using a chamber and two tritium samplers, enables determination of ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006435
更新日期:2001-01-01 00:00:00
abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs260
更新日期:2013-05-01 00:00:00
abstract::The aim of the study was to estimate organ dose rate reduction to a female anthropomorphic phantom, which simulated the cardiologist, during percutaneous coronary interventions (PCI) when the patient's arm support was covered with 0.4-mm lead foil. Organ dose rates were determined using five radiation detectors insert...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz292
更新日期:2020-06-24 00:00:00
abstract::To estimate the absorbed dose in normal organs and inflamed tissue following i.v. administration of [201Tl](III)-DTPA-HIgG by using biodistribution data in inflamation bearing rats was attempted. The percentages of injected dose per gram of each organ were calculated. The medical internal radiation dose formulation was...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq172
更新日期:2010-10-01 00:00:00
abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx020
更新日期:2017-11-01 00:00:00
abstract::During medical X-ray examinations of patients, humans as well as animals, voluntarily assisting persons are frequently needed in order to calm down the patient or animal. Typical exposure situations have been identified and measurements were performed in the fields of scattered X-rays. The personal dose equivalent H(p...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq351
更新日期:2011-03-01 00:00:00
abstract::The microdosimetric one hit detector model was applied to calculate the dose response, energy response and relative thermoluminescence (TL) efficiency, eta, of high sensitive LiF:Mg,Cu,P and Al(2)O(3):C detectors after their irradiations by X rays, gamma rays, beta electrons and heavy charged particles (HCP). Microdos...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl467
更新日期:2006-01-01 00:00:00
abstract::In this paper, the result of systematic measurement of the soil gas radon concentrations is discussed and the background values are defined along and around the Main Central Thrust (MCT) in Ukhimath region of Garhwal Himalaya, India. The Ukhimath region is being subjected to intense neotectonic activities like earthqu...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw067
更新日期:2016-10-01 00:00:00
abstract::The purpose of this work was to review the reasonable measures that should be implemented as part of a routine practice in the process of managing CT radiation risks in a typical average radiology department. Based on 6 y of experience in the management of a general radiology department and the newly implemented suppo...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv038
更新日期:2015-07-01 00:00:00
abstract::Regional cooperation in radioactive waste management (RWM) in the Asian and Oceanic countries has been successfully developing for more than 20 y. At present, the Asian and Oceanic countries recognise that there are several projects under the regional cooperation, such as the Forum for Nuclear Cooperation in Asia (FNC...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr124
更新日期:2011-07-01 00:00:00
abstract::238U, 234U and 235U were determined in tap water from municipal water pipes that drew their supply from surface water or ground water in various locations in Poland. Average activity concentrations of 238U, 234U and 235U in tap water from surface water were 9.6 +/- 7.1, 12.8 +/- 9.7 and 0.41 +/- 0.31 Bq m(-3), respect...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch425
更新日期:2005-01-01 00:00:00
abstract::Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw153
更新日期:2016-12-01 00:00:00
abstract::Spinal deformities affect young individuals predominantly girls who are usually subjected to regular and intensive radiological investigation especially before and after corrective surgery. Optimisation of spine computed tomography (CT) and the implementation of the low-dose CT in the work-up of spinal deformities wer...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp306
更新日期:2010-04-01 00:00:00
abstract::The main purpose of dose surveys has been to detect and bring down wide variation in radiation doses for any particular radiological examination and to avoid doses that are on higher side. Diagnostic reference levels (DRLs) have been used for over two decades as an aid in this objective. With very limited success that...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv063
更新日期:2015-07-01 00:00:00
abstract::The Christian ethical tradition introduces a number of key values into the clinical context. Moreover, although some denominational differences exist, these are essentially differences of emphasis rather than of substance. Among the central values which the Christian tradition promotes are: the dignity of the person, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp044
更新日期:2009-07-01 00:00:00
abstract::A novel single cell irradiation system using carbon nanotube (CNT) based field emission technology is proposed. The system can produce electron microbeam at a large range of pulsation frequencies and dose rates with energy between 20 and 60 keV. Different from any existing single beam microbeam device, the CNT-based s...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl508
更新日期:2006-01-01 00:00:00
abstract::In diagnostic nuclear medicine, the biokinetics of the radiopharmaceutical (actually of the radionuclide) is determined for a number of representative patients. At therapy, it is essential to determine the patient's individual biokinetics of the radiopharmaceutical in order to calculate the absorbed doses to critical ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv061
更新日期:2015-07-01 00:00:00
abstract::A current-mode neutron detector with a pair of 6Li- and 7Li-glass scintillators has been developed to measure high-flux neutrons in a boron neutron capture therapy field. Neutrons are basically measured by subtracting gamma-ray component using current outputs from the 7Li-glass scintillator. In the present study, the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz266
更新日期:2020-06-12 00:00:00
abstract::The DIS-1 dosemeter from the Finnish company RADOS is an innovative kind of passive electronic dosemeter for photon and beta radiation. This study examines the 'long-term' linear response behaviour, the calibration and readout accuracy with large samples of 'used' DIS-1 dosemeters especially in the low-dose region, wh...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm240
更新日期:2008-01-01 00:00:00
abstract::The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq002
更新日期:2010-04-01 00:00:00
abstract::The present study analyses the electric field radiating from the GSM/UMTS base stations located in central Malatya, a densely populated urban area in Turkey. The authors have conducted both instant and continuous measurements of high-frequency electromagnetic fields throughout their research by using non-ionising radi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv008
更新日期:2016-01-01 00:00:00
abstract::A high-end drum film digitiser (Tango, Germany) and a calibrated linear microdensitometer developed by PTB were used to assess the modulation transfer function (MTF) and the noise power spectra (NPS) of 3 mammographic screen film systems at optical density levels of 0.8, 1.5 and 2.5. The use of a drum scanner to asses...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch563
更新日期:2005-01-01 00:00:00
abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy142
更新日期:2018-12-01 00:00:00