Abstract:
:238U, 234U and 235U were determined in tap water from municipal water pipes that drew their supply from surface water or ground water in various locations in Poland. Average activity concentrations of 238U, 234U and 235U in tap water from surface water were 9.6 +/- 7.1, 12.8 +/- 9.7 and 0.41 +/- 0.31 Bq m(-3), respectively, whereas from ground water they were 4.5 +/- 6.0, 5.7 +/- 6.9 and 0.19 +/- 0.27 Bq m(-3), respectively. Activity concentrations of 234U were higher than 238U. Ratios of 234U/238U ranged from 1.07 to 2.60, indicating the lack of equilibrium between these isotopes. The average 235U/238U ratio was 0.043 +/- 0.008, being close to 0.046 for natural uranium. Average annual intake with water and food was 7.6 +/- 5.1 Bq for 238U and 9.5 +/- 6.6 Bq for 234U. Annual committed effective doses calculated from these intakes for adults were 0.34 +/- 0.23 and 0.47 +/- 0.32 microSv, respectively; 235U contributed to the total dose from the uranium isotopes by about 2%.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Pietrzak-Flis Z,Kaminska I,Chrzanowski Edoi
10.1093/rpd/nch425keywords:
subject
Has Abstractpub_date
2005-01-01 00:00:00pages
34-9issue
1eissn
0144-8420issn
1742-3406pii
nch425journal_volume
113pub_type
杂志文章abstract::An investigation of the thermoluminescence (TL) properties of high pressure, high temperature (HPHT) synthetic diamond crystals grown under diluted nickel or cobalt as solvent catalysts is reported. After a study of TL properties of 6 different samples, it is shown that a crystal grown with Ni+2%Ti and annealed at 210...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005880
更新日期:2002-01-01 00:00:00
abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci048
更新日期:2005-01-01 00:00:00
abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci667
更新日期:2006-01-01 00:00:00
abstract::The substantive safety of radiological and other medical procedures can be radically reduced by unconscious factors governing scientific thought. In addition, the historical exclusion of women from these disciplines has possibly skewed their development in directions that now need to be addressed. This paper focuses o...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp055
更新日期:2009-07-01 00:00:00
abstract::Exposure to radon and radon decay products in some residential areas and at workplaces constitutes one of the greatest risks from natural sources of ionising radiation. Recently, increasing attention has been paid to the precise estimations of this health risk by numerous models. The compartmental model published in I...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006173
更新日期:2003-01-01 00:00:00
abstract::The aim of biological dosimetry is to estimate the dose and the associated uncertainty to which an accident victim was exposed. This process requires the use of the maximum-likelihood method for fitting a calibration curve, a procedure that is not implemented in most statistical computer programs. Several laboratories...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm137
更新日期:2007-01-01 00:00:00
abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006710
更新日期:2002-01-01 00:00:00
abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm231
更新日期:2008-01-01 00:00:00
abstract::In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiati...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu315
更新日期:2015-04-01 00:00:00
abstract::A dose evaluation method for neutrons in the energy range of a few MeV to 100 MeV has been developed using a spectrum weight function (G-function), which is applied to an organic liquid scintillator of 12.7 cm in diameter and 12.7 cm in length. The G-function that converts the pulse height spectrum of the scintillator...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006071
更新日期:2002-01-01 00:00:00
abstract::Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effec...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv539
更新日期:2016-09-01 00:00:00
abstract::This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu075
更新日期:2014-07-01 00:00:00
abstract::This study aims to describe current risk management practices and policies across the world in relation to personal exposures from devices emitting radiofrequency fields, environmental exposures from fixed installations and exposures in the work environment. Data from 86 countries representing all WHO regions were col...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu324
更新日期:2015-04-01 00:00:00
abstract::A device able to trap a liquid droplet in a host liquid in a metastable (superheated) state was developed for a better understanding of the operational principles and for an extension of the application of superheated drop detectors (SDDs). Droplets of trans-2-butene in a metastable state were exposed to Am-Be neutron...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006122
更新日期:2003-01-01 00:00:00
abstract::This study aimed to reveal the effect of X-irradiation on mitochondrial function in terms of mitochondrial membrane potential (ΔΨm) and ATP productivity. At the cellular level, ΔΨm was quantified using JC-1, a mitochondrial probe that emits red or green fluorescence at high or low ΔΨm sites, respectively. The fluoresc...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy254
更新日期:2019-05-01 00:00:00
abstract::The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq416
更新日期:2011-03-01 00:00:00
abstract::Efficiency tracing with unquenched 14C and zero detection threshold with unquenched 3H as tracers are practical and simple techniques which have been implemented to quantify the activity of various beta emitters using liquid scintillation analyser. These techniques are used to study the influence of quench level on ac...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq495
更新日期:2011-11-01 00:00:00
abstract::Positron emission tomography (PET) is a non-invasive medical imaging technique normally used for diagnostic purposes to determine the location and concentration of physiologically active compounds in a human body. An unshielded cyclotron is used for PET at the Clinica Universitaria de Navarra to produce short-lived po...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm077
更新日期:2007-01-01 00:00:00
abstract::CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-dope...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci515
更新日期:2006-01-01 00:00:00
abstract::The Federal Office for Radiation Protection performed a representative survey on the radiological quality of drinking water in Germany. The aim of this study was to determine regional variations of natural radionuclide concentrations and to estimate radiation exposures caused by drinking water consumption. The study i...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq139
更新日期:2010-09-01 00:00:00
abstract::In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and direct radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Radiology Emergency Department of our hospital, a flat-panel DR equipment (Siemens Axiom Ari...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn013
更新日期:2008-01-01 00:00:00
abstract::The present paper shows methods to suppress radon emanation from artificial porous materials such as phosphorous fertiliser or diatomaceous earth with a small amount of radium. The basic concept of suppression is making the radon emanation mechanism 'null', which comes from the fact that recoil is the main mechanism o...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm420
更新日期:2007-01-01 00:00:00
abstract::One encouraging way, at present, to put the investigation of ionisation-yield formation in sub-cellular structures or, at least, in nanometric volumes of liquid water on an experimental basis is the use of highly sophisticated counters filled with gases at low operating pressure to simulate target volumes a few nm in ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006818
更新日期:2002-01-01 00:00:00
abstract::The aim of the present work is to investigate the possibility of using the properties of the thermoluminescent emission (TL) of Brazilian natural topaz for dosimetric applications. Topaz is an aluminium fluorsilicate with general composition of Al2(SiO4)(F,OH)2 found with relative abundance in Brazil and in other part...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005902
更新日期:2002-01-01 00:00:00
abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs260
更新日期:2013-05-01 00:00:00
abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl389
更新日期:2006-01-01 00:00:00
abstract::The aim of the study was to estimate organ dose rate reduction to a female anthropomorphic phantom, which simulated the cardiologist, during percutaneous coronary interventions (PCI) when the patient's arm support was covered with 0.4-mm lead foil. Organ dose rates were determined using five radiation detectors insert...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz292
更新日期:2020-06-24 00:00:00
abstract::The localisation of an unknown neutron source in various bulky homogeneous media was studied. For the planar case two (3)He detectors on the opposite faces of a box were used. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron de...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm048
更新日期:2007-01-01 00:00:00
abstract::This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reade...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz186
更新日期:2019-12-31 00:00:00
abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz226
更新日期:2019-12-31 00:00:00