Abstract:
:This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler improves 13.6 times the sampling efficiency and leads to 6.5 times smaller minimmal detectable activity concentrations (MDAC) compared with the PC grains used so far. For a 40-h exposure of 7.4-g PC powder to 222Rn in air, the MDAC with a RackBeta 1219 LS counter is 62 Bq m(-3) (assuming a 8-h sample counting time and 24-h background time). For the same conditions the estimated 222Rn MDAC with a Quantulus 1220 LS counter is 20 Bq m(-3). The proposed technique is suitable for radon in air and radon in soil-gas measurements.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Mitev K,Georgiev S,Pressyanov D,Dimitrova I,Zhivkova V,Boshkova Tdoi
10.1093/rpd/ncu075subject
Has Abstractpub_date
2014-07-01 00:00:00pages
188-91issue
1-3eissn
0144-8420issn
1742-3406pii
ncu075journal_volume
160pub_type
杂志文章abstract::Elevated levels of natural background radiation due to scattered patches of monazite sand around the beaches of Mangalore, India, have been reported earlier. A comparative study of gamma dose rates was performed in both normal background and high natural background radiation areas around Mangalore using different type...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz063
更新日期:2019-10-01 00:00:00
abstract::The model and development is described of a new generation of Monte Carlo track structure codes. The code LEPHIST simulates full slowing down of low-energy proton history tracks in the range 1 keV-1 MeV and the code LEAHIST simulates low-energy alpha particle history tracks in the range 1 keV-8 MeV in water. All prima...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006838
更新日期:2002-01-01 00:00:00
abstract::This paper presents the results of radon concentration measurements in drinking water from the municipal water supply system and private wells located in Baoji, China. The measurements were carried out on 69 samples. The mean values of tap water and well water were found to be 12 kBq m(-3) with a maximum of 18 kBq m(-...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl048
更新日期:2006-01-01 00:00:00
abstract::Tissue-equivalent proportional counters (TEPCs) have long been considered suitable candidate instruments for more accurate neutron monitors in nuclear power plants. It has also been recognised that the production of truly light-weight devices based on TEPCs requires further effort directed towards increasing their sen...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq538
更新日期:2011-02-01 00:00:00
abstract::A comparative analysis of radiation doses determined by tooth enamel electron paramagnetic resonance (EPR) spectroscopy and by an acknowledged analytical method is performed for individual doses and for average doses in population of some settlements of the Bryansk region (Russia), which have been contaminated after t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu132
更新日期:2014-06-01 00:00:00
abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/oxfordjournals.rpd.a006619
更新日期:2001-01-01 00:00:00
abstract::A Monte Carlo based computational procedure for determining organ doses and effective doses has been described for two procedures used in newly developed image-guided radiation treatment: kilovoltage cone-beam computed tomography (kV CBCT) and mega-voltage computed tomography (MV CBCT). A whole-body patient computatio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn200
更新日期:2008-01-01 00:00:00
abstract::Computed tomography dose index w and dose length product were recorded for the purpose of developing diagnostic reference levels (DRLs) for radiation dose optimisation. The study was conducted in three radiology departments with CT centres in Northern Nigeria. Data were collected from 54 consenting adult participants ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,多中心研究
doi:10.1093/rpd/ncv188
更新日期:2015-07-01 00:00:00
abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw199
更新日期:2016-09-01 00:00:00
abstract::Classical aerosol physics predicts that it is impossible to observe noticeable values of the unattached fraction of decay products of thoron at typical concentrations of aerosol particles. The experimental data have shown that the unattached fraction of the thoron decay products in a monazite storage facility is in th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa154
更新日期:2020-11-27 00:00:00
abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006090
更新日期:2002-01-01 00:00:00
abstract::The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident has resulted in the deposition of radioactive contamination of soils mainly by (134)Cs and (137)Cs. The contaminated areas are of a great concern since external radiation may lead to significant long-term doses to humans and animals. External dose rate above g...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv276
更新日期:2015-11-01 00:00:00
abstract::Work is presented on the development of a retrospective/fortuitous accident dosimetry service using optically stimulated luminescence of resistors found in mobile phones to determine the doses of radiation to members of the public following a radiological accident or terrorist incident. The system is described and dis...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu370
更新日期:2015-04-01 00:00:00
abstract::Electron paramagnetic resonance spectra and dose-response curves are presented for a variety of wallboard samples obtained from different manufacturing facilities, as well as for source gypsum and anhydrite. The intensity of the CO(3)(-) paramagnetic centre (G2) is enhanced with gamma radiation. Isothermal decay curve...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq581
更新日期:2011-11-01 00:00:00
abstract::The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm095
更新日期:2007-01-01 00:00:00
abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn096
更新日期:2008-01-01 00:00:00
abstract::The evaluation of exposure to extremely low-frequency (ELF) magnetic fields using broadband measurement techniques gives satisfactory results when the field has essentially a single frequency. Nevertheless, magnetic fields are in most cases distorted by harmonic components. This work analyses the harmonic components o...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu175
更新日期:2015-02-01 00:00:00
abstract::The aim of the present work is to investigate the possibility of using the properties of the thermoluminescent emission (TL) of Brazilian natural topaz for dosimetric applications. Topaz is an aluminium fluorsilicate with general composition of Al2(SiO4)(F,OH)2 found with relative abundance in Brazil and in other part...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005902
更新日期:2002-01-01 00:00:00
abstract::Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effec...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv539
更新日期:2016-09-01 00:00:00
abstract::The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv250
更新日期:2015-11-01 00:00:00
abstract::Much attention has been devoted in the past to monitor changes of mobile lipid (ML) (1)H MRS signals in spectra of tumour cells. The purpose of this work is to exploit ML signals to provide information on cell metabolism after irradiation, comparing tumour cells characterised by different radiosensitivity and relating...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl517
更新日期:2006-01-01 00:00:00
abstract::Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-h...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch550
更新日期:2005-01-01 00:00:00
abstract::This paper presents the values of radon and thoron progeny concentrations for different seasons in the dwellings of Tehri Garhwal, India. The measurements have been carried out using LR-115 solid-state nuclear track detector-based passive time-integrated direct thoron progeny sensor/direct radon progeny sensor techniq...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv224
更新日期:2015-11-01 00:00:00
abstract::Two counting techniques are proposed in this paper to estimate thoron ((220)Rn) concentration using a Lucas scintillation cell. The alpha activity build-up inside the cell is calculated theoretically by using Bateman equations. The first method is having a minimum detection limit of 325 Bq m(-3) and can be used for th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr438
更新日期:2012-07-01 00:00:00
abstract::The thermoluminescence (TL) characteristics of sodium chloride (NaCl), known as common salt, used for cooking purposes (iodised salt), have been studied in the present paper considering its usage as an 'accidental dosemeter' in the case of a nuclear fallout. TL characteristics of common salt have been examined under e...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci568
更新日期:2006-01-01 00:00:00
abstract::Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci366
更新日期:2006-01-01 00:00:00
abstract::In the event of a criticality accident, not only the maximal doses received by the victims must be determined but it is also crucial to evaluate the doses to the different organs. With a neutron component, morphology is a key parameter in the organ dose calculation. As the simulation tools can be time consuming to pro...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa123
更新日期:2020-11-06 00:00:00
abstract::A small, specialised amplifier using commercial integrated circuits (ICs) was developed to measure radiation dose and quality in real time using a microdosimetric ion chamber and the variance method. The charges from a microdosimetric ion chamber, operated in the current mode, were repeatedly collected for a fixed per...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm231
更新日期:2008-01-01 00:00:00
abstract::A methodology for the evaluation of skin dose distribution and possible skin injuries on patients undergoing interventional procedures has been developed as part of the European DIMOND programme. Relevant dosimetric data from the procedures are recorded and other specific measurements for skin dose evaluation (slow fi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci714
更新日期:2005-01-01 00:00:00
abstract::In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn247
更新日期:2008-01-01 00:00:00