Estimation of thoron concentration using scintillation cell.

Abstract:

:Two counting techniques are proposed in this paper to estimate thoron ((220)Rn) concentration using a Lucas scintillation cell. The alpha activity build-up inside the cell is calculated theoretically by using Bateman equations. The first method is having a minimum detection limit of 325 Bq m(-3) and can be used for thoron measurement in thorium-processing plants. In the second method, thoron concentration is calculated using the alpha counts from thoron progenies and is a reference to the first method. The results obtained by these techniques compare well with the double filter method.

journal_name

Radiat Prot Dosimetry

authors

Sumesh CG,Kumar AV,Nair RN,Tripathi RM,Puranik VD

doi

10.1093/rpd/ncr438

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

536-40

issue

4

eissn

0144-8420

issn

1742-3406

pii

ncr438

journal_volume

150

pub_type

杂志文章
  • Ten years of monitoring the occupational radiation exposure in Bosnia and Herzegovina.

    abstract::Monitoring of occupationally exposed persons in Bosnia and Herzegovina started in 1960s and it was interrupted in 1992. Dosimetry service resumed in 1999 when the International Atomic Energy Agency provided Harshaw 4500 TLD-reader and the first set of TLDs for the Radiation Protection Centre (RPC) of the Institute of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq006

    authors: Basić B,Beganović A,Samek D,Skopljak-Beganović A,Gazdić-Santić M

    更新日期:2010-04-01 00:00:00

  • Reliability of the ICRP'S dose coefficients for members of the public: IV. basis of the human alimentary tract model and uncertainties in model predictions.

    abstract::The biokinetic and dosimetric model of the gastrointestinal (GI) tract applied in current documents of the International Commission on Radiological Protection (ICRP) was developed in the mid-1960s. The model was based on features of a reference adult male and was first used by the ICRP in Publication 30, Limits for In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl104

    authors: Leggett R,Harrison J,Phipps A

    更新日期:2007-01-01 00:00:00

  • Collaboration of local government and experts responding to increase in environmental radiation level due to the nuclear disaster: focusing on their activities and latest radiological discussion.

    abstract::Activities were introduced in Kashiwa city in the Tokyo metropolitan area to correspond to the elevated environmental radiation level after the disaster of the Fukushima Daiichi nuclear power plant. These were based on a strong cooperation between local governments and experts. Ambient dose rate and radioactivity of f...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv279

    authors: Iimoto T,Nunokawa J,Fujii H,Takashima R,Hashimoto M,Fukuhara T,Yajima T,Matsuzawa H,Kurosawa K,Yanagawa Y,Someya S

    更新日期:2015-11-01 00:00:00

  • COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS.

    abstract::In radiotherapy, radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz231

    authors: Dufek V,Horakova I,Koniarova I

    更新日期:2019-12-31 00:00:00

  • 131I DOSE ESTIMATION FROM INTAKE OF TAP WATER IN THE EARLY PHASE AFTER FUKUSHIMA DAIICHI NUCLEAR POWER PLANT ACCIDENT.

    abstract::In March 2011, the Fukushima Daiichi Nuclear Power Plant Accident occurred and a large amount of radionuclides was released. To study its effect, we estimated the internal exposure due to intake of tap water in the early phase after the accident. As the number of measured values of tap water following the accident was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx208

    authors: Kawai M,Yoshizawa N,Suzuki G

    更新日期:2018-04-01 00:00:00

  • Uranium isotopes in public drinking water and dose assessment for man in Poland.

    abstract::238U, 234U and 235U were determined in tap water from municipal water pipes that drew their supply from surface water or ground water in various locations in Poland. Average activity concentrations of 238U, 234U and 235U in tap water from surface water were 9.6 +/- 7.1, 12.8 +/- 9.7 and 0.41 +/- 0.31 Bq m(-3), respect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch425

    authors: Pietrzak-Flis Z,Kaminska I,Chrzanowski E

    更新日期:2005-01-01 00:00:00

  • Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle.

    abstract::Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl545

    authors: Krol M,Lankoff A,Buraczewska I,Derezinska E,Wojcik A

    更新日期:2007-01-01 00:00:00

  • INVESTIGATION OF THE INFLUENCE OF THE POSITION INSIDE A SMALL AIRCRAFT ON THE COSMIC-RADIATION-INDUCED DOSE.

    abstract::This article report the measurements on-board a small aircraft at the same altitude and around the same geographic coordinates. The measurements of Ambient Dose Equivalent Rate (H*(10)) were performed in several positions inside the aircraft, close and far from the pilot location and the discrimination between neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw384

    authors: Prado ACM,Pazianotto MT,Gonçalez OL,Dos Santos LR,Caldeira AD,Pereira HHC,Hubert G,Federico CA

    更新日期:2017-11-01 00:00:00

  • Correlation of phase transition with the change in TL characteristics in CaSO4:Dy phosphor--effect of thermal treatment.

    abstract::The study is aimed at optimising the glow curve structure of CaSO4:Dy phosphor for dosimetric purpose and also to understand the observed changes owing to thermal treatment in the thermoluminescence (TL) sensitivity and glow curve structure. The reversible changes in the intensities of the lower temperature satellite ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci561

    authors: Bakshi AK,Pradhan AS,Tyagi AK,Kher RK,Bhatt BC

    更新日期:2006-01-01 00:00:00

  • CT dosimetry: getting the best from the adult Cristy phantom.

    abstract::The use of geometrical phantoms for computed tomography (CT) dosimetry can incur errors in the calculation of effective dose due to the anatomically incorrect organ shapes and distributions, and unrepresentative body dimensions. A Monte Carlo program that makes use of an anatomically correct voxel phantom has been dev...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch521

    authors: Castellano IA,Dance DR,Evans PM

    更新日期:2005-01-01 00:00:00

  • Methods and materials for the measurement of subjective and objective measurements of image quality.

    abstract::The evaluation of medical imaging systems may be performed using both subjective (e.g. high contrast limiting resolution, and low contrast detail detectability), and objective/physical (e.g. characteristic curve, signal-to-noise ratio, modulation transfer function, and Wiener spectra) indices of image quality. For the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006476

    authors: Marsh DM,Malone JF

    更新日期:2001-01-01 00:00:00

  • THE IMPACT OF CIRCADIAN RHYTHMS ON MEDICAL IMAGING AND RADIOTHERAPY REGIMES FOR THE PAEDIATRIC PATIENT.

    abstract::Daily rhythmic changes are found in cellular events in cell cycle, DNA repair, apoptosis and angiogenesis in both normal and tumour tissue, as well as in enzymatic activity and drug metabolism. In this paper, we hypothesize that circadian rhythms need to be considered in radiation protection and optimization in person...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw328

    authors: Forssell-Aronsson E,Quinlan RA

    更新日期:2017-04-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

    abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci667

    authors: Preciado-Flores S,Schreck M,Meléndrez R,Chernov V,Bernal R,Cruz-Vázquez C,Cruz-Zaragoza E,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital.

    abstract::To assess the frequency of examination, image quality (IQ) and establishment of local diagnostic reference levels (LDRLs) in paediatric radiographic examinations. The X-ray device performance, film reject rate and IQ grading were assessed at Radiology Department of a referral and teaching children's hospital in Kenya....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs270

    authors: Wambani JS,Korir GK,Korir IK,Kilaha S

    更新日期:2013-05-01 00:00:00

  • INTERCAL: long-term inter-comparison experiment for dose rate and spectrometric probes.

    abstract::The Schauinsland inter-calibration facility (INTERCAL) has been designed to enable long-term comparison experiments for 20 different dose rate probes from different networks. Two reference probes characterised by the European Radiation Dosimetry WG3 inter-calibration experiments in 2008 and 2009 have been installed at...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu039

    authors: Bleher M,Doll H,Harms W,Stöhlker U

    更新日期:2014-08-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • Indoor radon and thoron levels in Neendakara and Chavara regions of southern coastal Kerala, India.

    abstract::Some areas of the world, called high background radiation areas (HBRAs), have anomalously high levels of natural background radiation and the population residing in the areas is exposed to higher levels of radiation doses than other parts of the world where the natural radioactivity contents are normal. In the present...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr399

    authors: Pereira CE,Vaidyan VK,Chougaonkar MP,Mayya YS,Sahoo BK,Jojo PJ

    更新日期:2012-07-01 00:00:00

  • Assessment of patient organ doses and effective doses using the VIP-Man adult male phantom for selected cone-beam CT imaging procedures during image guided radiation therapy.

    abstract::A Monte Carlo based computational procedure for determining organ doses and effective doses has been described for two procedures used in newly developed image-guided radiation treatment: kilovoltage cone-beam computed tomography (kV CBCT) and mega-voltage computed tomography (MV CBCT). A whole-body patient computatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn200

    authors: Gu J,Bednarz B,Xu XG,Jiang SB

    更新日期:2008-01-01 00:00:00

  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D

    更新日期:2004-01-01 00:00:00

  • Stability of A-150 plastic ionisation chamber response over a approximately 30-y period.

    abstract::At the Northern Illinois University Institute for Neutron Therapy at Fermilab, the clinical tissue-equivalent ionisation chamber response is measured every treatment day using a cesium source that was configured to match readings obtained at the National Bureau of Standards. Daily measurements are performed in air usi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm126

    authors: Kroc TK,Lennox AJ

    更新日期:2007-01-01 00:00:00

  • The UK Childhood Cancer Study: maternal occupational exposures and childhood leukaemia and lymphoma.

    abstract::Risks of childhood leukaemia and lymphoma were investigated for specific work-related exposures of mothers in the UK Childhood Cancer Study. Interviews with parents of 1881 leukaemia and lymphoma cases (0-14 years) and 3742 controls collected job histories recording exposure to eight specific agents. Exposure was (1) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn265

    authors: McKinney PA,Raji OY,van Tongeren M,Feltbower RG

    更新日期:2008-01-01 00:00:00

  • Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry.

    abstract::The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al(2)O(3):C,Mg) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm058

    authors: Sykora GJ,Akselrod MS,Salasky M,Marino SA

    更新日期:2007-01-01 00:00:00

  • Radioactive waste management and decommissioning of accelerator facilities.

    abstract::During the operation of high-energy accelerators, the interaction of radiation with matter can lead to the activation of the machine components and of the surrounding infrastructures. As a result of maintenance operation and during decommissioning of the installation, considerable amounts of radioactive waste are evac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp196

    authors: Ulrici L,Magistris M

    更新日期:2009-11-01 00:00:00

  • COMMITTED EFFECTIVE DOSE DUE TO THE INTAKE OF 40K, 226Ra, 228Ra AND 228Th CONTAINED IN FOODS INCLUDED IN THE DIET OF THE RIO DE JANEIRO CITY POPULATION, BRAZIL.

    abstract::Annual effective dose due to the consumption of 40K, 226Ra, 228Ra and 228Th was estimated from high-resolution gamma spectrometry, food consumption data for the inhabitants of Rio de Janeiro City and dose coefficients published by the ICRP 119. A total of 31 samples of cereals, grains, vegetables, flours, liquid and p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx310

    authors: Lopes JM,Garcêz RWD,Filgueiras RA,Silva AX,Braz D

    更新日期:2018-10-01 00:00:00

  • Development of a retrospective/fortuitous accident dosimetry service based on OSL of mobile phones.

    abstract::Work is presented on the development of a retrospective/fortuitous accident dosimetry service using optically stimulated luminescence of resistors found in mobile phones to determine the doses of radiation to members of the public following a radiological accident or terrorist incident. The system is described and dis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu370

    authors: Smith RW,Eakins JS,Hager LG,Rothkamm K,Tanner RJ

    更新日期:2015-04-01 00:00:00

  • A follow-up study on indoor 222Rn, 220Rn their decay product concentrations in a mineralised zone of Himachal Pradesh, India.

    abstract::A follow-up study was taken up in a mineralised zone situated in Hamirpur district, Himachal Pradesh, India, to investigate high values of radon concentrations reported in past studies as well to update the old radon data based on bare SSNTD technique. In the present investigation, the concentrations of indoor radon, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv367

    authors: Bajwa BS,Singh P,Singh P,Saini K,Singh S,Sahoo BK,Sapra BK

    更新日期:2016-03-01 00:00:00

  • Measuring aerosols generated inside armoured vehicles perforated by depleted uranium ammunition.

    abstract::In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the US Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects on soldiers in vehicles struck by these munitions. As part of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006215

    authors: Parkhurst MA

    更新日期:2003-01-01 00:00:00

  • Electric and magnetic fields generated by ac power lines: an application of advanced modelling tools in order to predict exposure levels.

    abstract::In view of expected legislation changes imposing more severe limits on magnetic flux density, proposals are made based on theory and measurement for adjustment of Fower placement with regard to efficiency, cost and cost-benefit. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006689

    authors: Manco D,Bruzzi L,Soloni A,Valbonetti D,Fabbri S,Violanti S

    更新日期:2001-01-01 00:00:00

  • VALIDATION OF A BEAMNRC MONTE CARLO SIMULATION OF A BROAD BEAM DIAGNOSTIC X-RAY UNIT.

    abstract::A BEAMnrc Monte Carlo simulation of a diagnostic X-ray unit in a broad beam geometry intended for the derivation of effective linear attenuation coefficients was validated against measurements made on the X-ray unit on which the simulation was based. The validation process assessed the size of the beam, the first and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz032

    authors: Worrall M,Sutton DG

    更新日期:2019-12-31 00:00:00