CALCULATION OF CONVERSION COEFFICIENTS FOR VOXELIZED PHANTOMS FOR CRITICALITY ACCIDENT DOSIMETRY.

Abstract:

:In the event of a criticality accident, not only the maximal doses received by the victims must be determined but it is also crucial to evaluate the doses to the different organs. With a neutron component, morphology is a key parameter in the organ dose calculation. As the simulation tools can be time consuming to proceed, especially if morphology is taken into account, for all the victims, it may be very useful to have a database of conversion coefficients that allow to obtain the organ doses from the dose measured in the dosemeter for different kinds of morphology. In this paper, we present a study performed to evaluate such conversion coefficients using voxelized anthropomorphic phantoms. These coefficients take into account two crucial parameters having an impact on the dose at the organs: the orientation of the victim in the radiation field and the morphology, that is to say the body mass index of the different victims.

journal_name

Radiat Prot Dosimetry

authors

Chevallier MA,Pontier JB,Morin H,Duluc M,Evo S,Letang E,Trompier F

doi

10.1093/rpd/ncaa123

subject

Has Abstract

pub_date

2020-11-06 00:00:00

pages

9-24

issue

1

eissn

0144-8420

issn

1742-3406

pii

5912344

journal_volume

191

pub_type

杂志文章
  • Simulation of DNA damage after proton and low LET irradiation.

    abstract::A module for proton track structure simulation in liquid water was implemented in the biophysical model PARTRAC. Simulated tracks of energy deposition events from the radiation under investigation were superimposed on a higher-order DNA target model describing the whole genome inside a human cell. The parameters contr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006848

    authors: Friedland W,Bernhardt P,Jacob P,Paretzke HG,Dingfelder M

    更新日期:2002-01-01 00:00:00

  • Assessment of effective dose in paediatric CT examinations.

    abstract::Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr288

    authors: Dougeni E,Chapple CL,Willis J,Panayiotakis G

    更新日期:2011-09-01 00:00:00

  • An internal radiation dosimetry computer program, IDAC 2.0, for estimation of patient doses from radiopharmaceuticals.

    abstract::The internal dosimetry computer program internal dose assessment by computer (IDAC) for calculations of absorbed doses to organs and tissues as well as effective doses to patients from examinations with radiopharmaceuticals has been developed. The new version, IDAC2.0, incorporates the International Commission on Radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct337

    authors: Andersson M,Johansson L,Minarik D,Mattsson S,Leide-Svegborn S

    更新日期:2014-12-01 00:00:00

  • Nuclear reactions in Monte Carlo codes.

    abstract::The physics foundations of hadronic interactions as implemented in most Monte Carlo codes are presented together with a few practical examples. The description of the relevant physics is presented schematically split into the major steps in order to stress the different approaches required for the full understanding o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006788

    authors: Ferrari A,Sala PR

    更新日期:2002-01-01 00:00:00

  • European Study of Occupational Radiation Exposure (ESOREX).

    abstract::The European Study of Occupational Radiation Exposure (ESOREX) project was initiated by the general directive EC DG XI and carried out by the Bundesamt für Strahlenschutz, Germany (BfS). It consists of surveys carried out in the 28 European states. The study provides comparable descriptions of the national administrat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006602

    authors: Frasch G,Anatschkowa E,Kragh P

    更新日期:2001-01-01 00:00:00

  • MICRODOSIMETRIC SIMULATIONS OF CARBON IONS USING THE MONTE CARLO CODE FLUKA.

    abstract::Therapeutic carbon ion beams produce a complex and variable radiation field that changes along the penetration depth due to the high density of energy loss along the particle track together with the secondary particles produced by nuclear fragmentation reactions. An accurate physical characterisation of such complex m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx201

    authors: Chiriotti S,Conte V,Colautti P,Selva A,Mairani A

    更新日期:2018-08-01 00:00:00

  • Survey of patient dose in computed tomography in Syria 2009.

    abstract::The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq155

    authors: Kharita MH,Khazzam S

    更新日期:2010-09-01 00:00:00

  • PRACTICAL METHODS FOR INTERNAL DOSE ASSESSMENT FOR RADIOIODINE INTAKE AFTER THYROID BLOCKING: CLASSIFICATION OF DEGREE OF BLOCKAGE AND DETERMINATION OF INSENSITIVE MEASUREMENT POINT.

    abstract::Iodine thyroid blocking (ITB) suppresses the uptake of iodine to the thyroid and reduces internal doses after radioiodine intake; however, its disturbance of thyroid biokinetics causes considerable uncertainty in the use of dosimetric data intended for assessment of unblocked normal thyroid. To more accurately assess ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz139

    authors: Kwon TE,Park M,Jung GH,Chung Y,Ha WH,Jin YW

    更新日期:2019-12-31 00:00:00

  • Methods and materials for the measurement of subjective and objective measurements of image quality.

    abstract::The evaluation of medical imaging systems may be performed using both subjective (e.g. high contrast limiting resolution, and low contrast detail detectability), and objective/physical (e.g. characteristic curve, signal-to-noise ratio, modulation transfer function, and Wiener spectra) indices of image quality. For the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006476

    authors: Marsh DM,Malone JF

    更新日期:2001-01-01 00:00:00

  • Cellular signal transduction events as a function of linear energy transfer (LET).

    abstract::In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation, the number and size of pATM (S1981) and gamma-H2AX foci were compared in cultures of diploid human fibroblasts after exposure to charged particles of varying species, energ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm086

    authors: Fürweger C,Hajek M,Vana N,Kodym R,Okayasu R

    更新日期:2007-01-01 00:00:00

  • Suppression methods of radon emanation from phosphorus fertiliser and diatomaceous earth.

    abstract::The present paper shows methods to suppress radon emanation from artificial porous materials such as phosphorous fertiliser or diatomaceous earth with a small amount of radium. The basic concept of suppression is making the radon emanation mechanism 'null', which comes from the fact that recoil is the main mechanism o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm420

    authors: Sasaki T,Gunji Y,Okuda T

    更新日期:2007-01-01 00:00:00

  • COMMITTED EFFECTIVE DOSE DUE TO THE INTAKE OF 40K, 226Ra, 228Ra AND 228Th CONTAINED IN FOODS INCLUDED IN THE DIET OF THE RIO DE JANEIRO CITY POPULATION, BRAZIL.

    abstract::Annual effective dose due to the consumption of 40K, 226Ra, 228Ra and 228Th was estimated from high-resolution gamma spectrometry, food consumption data for the inhabitants of Rio de Janeiro City and dose coefficients published by the ICRP 119. A total of 31 samples of cereals, grains, vegetables, flours, liquid and p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx310

    authors: Lopes JM,Garcêz RWD,Filgueiras RA,Silva AX,Braz D

    更新日期:2018-10-01 00:00:00

  • Background radiation and individual dosimetry in the costal area of Tamil Nadu, India.

    abstract::South coast of India is known as the high-level background radiation area (HBRA) mainly due to beach sands that contain natural radionuclides as components of the mineral monazite. The rich deposit of monazite is unevenly distributed along the coastal belt of Tamil Nadu and Kerala. An HBRA site that laid in 2×7 m alon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr179

    authors: Matsuda N,Brahmanandhan GM,Yoshida M,Takamura N,Suyama A,Koguchi Y,Juto N,Raj YL,Winsley G,Selvasekarapandian S

    更新日期:2011-07-01 00:00:00

  • SPECTROSCOPIC STUDY ON POLY(ACRYLIC ACID-CO-ACRYLAMIDE)-GRAFT-POLYANILINE AS A RADIATION DOSIMETER FOR ALPHA PARTICLES.

    abstract::Poly(acrylate-co-acrylamide) was a synthesis by chemical oxidation polymerization of an aqueous binary mixture of acrylate/acrylamide (1:1 mole ratio) using ammonium persulphate as an initiator at 70°C under the nitrogen atmosphere. The obtained copolymer was introduced for grafting with polyaniline. The grafting proc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx124

    authors: Abd El-Mageed HR,Abd El-Salam HM,Eissa MF

    更新日期:2018-03-01 00:00:00

  • Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.

    abstract::Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci586

    authors: Ginjaume M,Pérez S,Ortega X,Duch MA

    更新日期:2006-01-01 00:00:00

  • STRUCTURAL ANALYSIS OF DNA REPAIR PROTEIN XRCC4 APPLYING CIRCULAR DICHROISM IN AN AQUEOUS SOLUTION.

    abstract::We applied circular dichroism (CD) spectral analysis to obtain the secondary structure of the DNA repair protein XRCC4, with a focus on its C-terminus. Using synchrotron radiation as a light source across a wide range of wavelengths, including vacuum ultraviolet (UV) light from 180 to 200 nm and UV light from 200 to 2...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy275

    authors: Nishikubo K,Izumi Y,Matsumoto Y,Fujii K,Matsuo K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Radiation dose management in CT, SPECT/CT and PET/CT techniques.

    abstract::New imaging technologies utilising X rays and radiopharmaceuticals are continuously under development. The benefit of computed tomography (CT) has been so dramatic that there is a tendency to overuse it and not to place enough efforts into optimisation of the technique. It is also now more and more common to combine t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr261

    authors: Mattsson S,Söderberg M

    更新日期:2011-09-01 00:00:00

  • PRUDENCE AND CONSERVATISM IN RADIATION PROTECTION: A CASE STUDY.

    abstract::Prudence is a cornerstone of radiation protection philosophy. However, whilst the concept is clearly valid at the level of principle, it is nonetheless necessary to ask 'How should prudence be applied in the context of various practical situations.' This is perhaps particularly important where exposures are low-within...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw310

    authors: Coates R

    更新日期:2017-04-01 00:00:00

  • Radiological emergency: Malaysian preparedness and response.

    abstract::Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr102

    authors: Yusof MA,Ali HM

    更新日期:2011-07-01 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • Implications of the space radiation environment for human exploration in deep space.

    abstract::Human exploration of the solar system beyond Earth's orbit will entail many risks for the crew on these deep space missions. One of the most significant health risks is exposure to the harsh space radiation environment beyond the protection provided by the Earth's intrinsic magnetic field. Crew on exploration missions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci141

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • MCNPX CALCULATIONS OF SPECIFIC ABSORBED FRACTIONS IN SOME ORGANS OF THE HUMAN BODY DUE TO APPLICATION OF 133Xe, 99mTc and 81mKr RADIONUCLIDES.

    abstract::Monte Carlo simulations were performed to evaluate treatment doses with wide spread used radionuclides 133Xe, 99mTc and 81mKr. These different radionuclides are used in perfusion or ventilation examinations in nuclear medicine and as indicators for cardiovascular and pulmonary diseases. The objective of this work was ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx181

    authors: Jovanovic Z,Krstic D,Nikezic D,Ros JMG,Ferrari P

    更新日期:2018-03-01 00:00:00

  • Application of the high-temperature ratio method for evaluation of the depth distribution of dose equivalent in a water-filled phantom on board space station Mir.

    abstract::A water-filled tissue equivalent phantom with a diameter of 35 cm was developed at the Institute for Biomedical Problems. Moscow. Russia. It contains four channels perpendicular to each other, where dosemeters can be exposed at different depths. Between May 1997 and February 1999 the phantom was installed at three dif...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005923

    authors: Berger T,Hajek M,Schöner W,Fugger M,Vana N,Akatov Y,Shurshakov V,Arkhangelsky V,Kartashov D

    更新日期:2002-01-01 00:00:00

  • RESULTS AND DISCUSSION ON JAPANESE PUBLIC OPINION SURVEYS (2006-17) ABOUT NUCLEAR AND RADIATION APPLICATIONS.

    abstract::Public opinion on the application of nuclear technology and radiation could change when a nuclear related event occurs. Japan Atomic Energy Relations Organization has tracked its variation through a nationwide opinion survey in Japan by almost the same way every year since FY 2006. We can identify a continuous long-te...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz127

    authors: Iimoto T,Takashima R,Kimura H,Kawakami K,Endo H,Yasuda H,Nagata N,Sakai N,Kawasaki Y,Funakoshi M

    更新日期:2019-10-01 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • Radiation protection culture: a global challenge.

    abstract::The central motto 'Radiation Protection Culture-A Global Challenge' of the fourth European IRPA Congress is discussed on the basis of the IRPA Guiding Principles Establishing a Radiation Protection Culture and the contributions presented in the plenary sessions of the conference. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu325

    authors: Michel R,Henrichs K,Wernli C

    更新日期:2015-04-01 00:00:00

  • Spatial distribution of indoor radon in Triveneto (Northern Italy): a geostatistical approach.

    abstract::The study of spatial distribution of the indoor radon has assumed in the last years a lot of interest. The geostatistical techniques turn out to be particularly promising. The present work presents the results of a study where around 4000 indoor radon data from Veneto, Friuli Venezia-Giulia and Alto Adige, collected d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp252

    authors: Bertolo A,Bigliotto C,Giovani C,Garavaglia M,Spinella M,Verdi L,Pegoretti S

    更新日期:2009-12-01 00:00:00

  • THE DECADE OF THE RABiT (2005-15).

    abstract::The RABiT (Rapid Automated Biodosimetry Tool) is a dedicated Robotic platform for the automation of cytogenetics-based biodosimetry assays. The RABiT was developed to fulfill the critical requirement for triage following a mass radiological or nuclear event. Starting from well-characterized and accepted assays we deve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw172

    authors: Garty G,Turner HC,Salerno A,Bertucci A,Zhang J,Chen Y,Dutta A,Sharma P,Bian D,Taveras M,Wang H,Bhatla A,Balajee A,Bigelow AW,Repin M,Lyulko OV,Simaan N,Yao YL,Brenner DJ

    更新日期:2016-12-01 00:00:00

  • Characterisation of non-constant background in counting measurements.

    abstract::A 'moving-target' method for characterising background in a counting measurement in which the instantaneous background count rate is a function of time, rather than being fixed, is proposed. This model treats the average Poisson mean in observation period P as coming from a gamma distribution with parameters αP and βP...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu297

    authors: Klumpp J,Miller G,Brandl A

    更新日期:2015-04-01 00:00:00

  • Determination of personal dose equivalents in accelerator radiation fields.

    abstract::Values for the dose equivalent are required for radiation protection purposes, but determination of such values can be quite difficult for high energy radiations. The accurate determination of personal dose equivalents in accelerator radiation fields requires the propel use of appropriate radiological quantities and u...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006629

    authors: McDonald JC

    更新日期:2001-01-01 00:00:00