Abstract:
:In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Farah J,Struelens L,Auvinen A,Jacob S,Koukorava C,Schnelzer M,Vanhavere F,Clairand Idoi
10.1093/rpd/ncu315subject
Has Abstractpub_date
2015-04-01 00:00:00pages
84-8issue
1-2eissn
0144-8420issn
1742-3406pii
ncu315journal_volume
164pub_type
杂志文章abstract::A current-mode neutron detector with a pair of 6Li- and 7Li-glass scintillators has been developed to measure high-flux neutrons in a boron neutron capture therapy field. Neutrons are basically measured by subtracting gamma-ray component using current outputs from the 7Li-glass scintillator. In the present study, the ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz266
更新日期:2020-06-12 00:00:00
abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci112
更新日期:2005-01-01 00:00:00
abstract::Three widely used anthropomorphic phantoms are analysed with regard to their suitability for the efficiency calibration of whole-body counters (WBCs): a Bottle Manikin Absorber (BOMAB) phantom consisting of water-filled plastic containers, a St Petersburg block phantom (Research Institute of Sea Transport Hygiene, St ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq320
更新日期:2011-03-01 00:00:00
abstract::An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005974
更新日期:2002-01-01 00:00:00
abstract::The aim of this study is to calculate total cruising route effective doses using three commonly used algorithm codes CARI-6, EPCARD and SIEVERT. Further, the impact of flight cruising duration, altitude and latitude on the estimated effective doses will also be investigated. A total of 24 commercial UAE flight data we...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy280
更新日期:2019-11-30 00:00:00
abstract::A model of radiation-induced bystander effects is presented that explicitly takes into account the transient nature of bystander signal emission post-irradiation, signal lifetime and the non-linear cellular response to the signals. Data are analysed on mutagenesis induced in human lymphoblasts in medium transfer exper...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv170
更新日期:2015-09-01 00:00:00
abstract::Much attention has been devoted in the past to monitor changes of mobile lipid (ML) (1)H MRS signals in spectra of tumour cells. The purpose of this work is to exploit ML signals to provide information on cell metabolism after irradiation, comparing tumour cells characterised by different radiosensitivity and relating...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl517
更新日期:2006-01-01 00:00:00
abstract::Continuous observation of radioactivity ratio of (214)Bi to (214)Pb as tracers in rainwater was carried out with 15-min cyclic measurement at Nagoya, Japan, from August 2011 to July 2012 to characterise wet deposition. The ratio ranged from 0.55 to 3.82. Based on the observation and a simplified time evolution model o...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv220
更新日期:2015-11-01 00:00:00
abstract::The aim of this work is to calculate the absorbed dose to matter due to neutrons in the 5-150 MeV energy range. Materials involved in the calculations are Al2O3, CaSO4 and CaS, which may be used as dosemeters and have already been studied for their luminescent properties. The absorbed dose is assumed to be mainly due ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch147
更新日期:2004-01-01 00:00:00
abstract::An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The meth...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs307
更新日期:2013-06-01 00:00:00
abstract::Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Institute of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation qua...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch111
更新日期:2004-01-01 00:00:00
abstract::The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reac...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr185
更新日期:2011-07-01 00:00:00
abstract::It is shown how the decision threshold, the detection limit and the limits of a coverage interval - summarily called the characteristic limits - and, in addition, the best estimate and the associated standard uncertainty of a non-negative radiation measurand are to be calculated by using the Monte Carlo (MC) method in...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp105
更新日期:2009-07-01 00:00:00
abstract::In this work, the electromagnetic interference on hearing aids was evaluated. Electromagnetic (EM) immunity tests on different types of hearing aids were carried out, using signals of intensity and modulation comparable to those present in the environment. The purpose of this work is to characterise the interference, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch052
更新日期:2004-01-01 00:00:00
abstract::In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron d...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch473
更新日期:2005-01-01 00:00:00
abstract::The Laboratory of External Dosimetry Studies and Researches (LRDE), associated laboratory to the Bureau National de Métrologie, is strongly involved in the reference establishment and calibration of instruments in neutron radiation fields provided by 241Am-Be, 252Cf and (252Cf + D2O)/Cd sources. In 1997, on the reques...
journal_title:Radiation protection dosimetry
pub_type: 指南,杂志文章,多中心研究
doi:10.1093/rpd/nch193
更新日期:2004-01-01 00:00:00
abstract::The national diagnostic reference levels (NDRLs) form an efficient, concise and powerful standard for optimising radiation protection of a patient. However, in a large hospital, where many radiological departments are present, it is also possible to calculate and define lower dose values as local diagnostic reference ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch432
更新日期:2005-01-01 00:00:00
abstract::Boron neutron capture therapy is known to be an effective radiation cancer therapy that requires neutron irradiation. A neutron field generated by an accelerator-based neutron source has various energy spectra, and it is necessary to evaluate the neutron spectrum in the treatment field. However, the method used to mea...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx237
更新日期:2018-08-01 00:00:00
abstract::In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme, different studies were aimed at improving the quality of radiation protection in interventional radiology and nuclear medicine. The main results of the project were...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs269
更新日期:2013-05-01 00:00:00
abstract::The counting efficiency and detection limit of an in vivo thyroid 131I monitoring system using an imaging plate (IP) were estimated using an anthropomorphic thyroid neck phantom. The counting efficiency of the IP system was approximately constant for thyroid volumes between 11.7 and 20 ml and neck diameters between 10...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006025
更新日期:2002-01-01 00:00:00
abstract::Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women i...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006733
更新日期:2002-01-01 00:00:00
abstract::An invited panel discussed with the participants of the Symposium their views on the impact of non-targeted effects on the relationship between microdosimetry and risk. The discussion was wide ranging and lively, with divergences of opinion. At one end was the view that understanding microscopic features and distribut...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq393
更新日期:2011-02-01 00:00:00
abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx020
更新日期:2017-11-01 00:00:00
abstract::The fast assessment of the dose received by exposed persons is crucial in radiological accidents, so the 48 h of cell culture in conventional cytogenetic dosimetry in addition to some limitations after high doses becomes a disadvantage. The premature chromosome condensation (PCC) assay permits to analyse enough cells ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu258
更新日期:2015-03-01 00:00:00
abstract::Absorbed fraction (AF) and specific absorbed fraction (SAF) are crucial values for the calculation of radionuclide S-values and consequently for internal dose estimates. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine (SNM) has been utilised as a standard in the...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl167
更新日期:2007-01-01 00:00:00
abstract::Soil gas radon measurements are carried out in a pilot study in three municipalities in Upper Austria. The selected municipalities are characterised by a high radon potential. Sixty measuring sites--well distributed over the region and over the different geological areas--were selected. Additionally, the permeability ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr089
更新日期:2011-05-01 00:00:00
abstract::Individual neutron dosimetry represents one of the current difficulties in the field of radiological protection of workers. Since March 1999, the regulatory requirements in France for active (i.e. operational) dosimetry have been those of ICRP Publication 60, applicable from May 2000, necessitating the introduction of...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006592
更新日期:2001-01-01 00:00:00
abstract::In order to investigate the influence of the static electricity on the measurement using passive radon detector, detectors were charged at the surface of chamber and its CR-39 elements respectively on purpose before the exposure in this study. The results of in-chamber experiments revealed that the static electricity ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz067
更新日期:2019-10-01 00:00:00
abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv430
更新日期:2016-06-01 00:00:00
abstract::A range of techniques has been developed in conventional radiography for the chest, because of technical difficulties in imaging the wide variation of tissue densities. These techniques can differ significantly in tube potential selection, for scatter reduction and in application of manual or automatic exposure contro...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch546
更新日期:2005-01-01 00:00:00