Specific absorbed fraction for Korean adult voxel phantom from internal photon source.

Abstract:

:Absorbed fraction (AF) and specific absorbed fraction (SAF) are crucial values for the calculation of radionuclide S-values and consequently for internal dose estimates. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine (SNM) has been utilised as a standard in the calculation of individual organ doses for biologically distributed radionuclides and for different types of radiation. Although those quantities are highly sensitive to individual anatomical difference, the SAF dataset calculated by Caucasian-based stylised phantoms have been applied to Korean population until now. This study was intended to calculate the SAFs by using realistic Korean voxel phantom and Monte Carlo transport technique for the first time and compare the results with those of the existing Caucasian-based data and the Korean stylised phantom published recently. The up-to-date realistic Korean voxel phantom, KTMAN-2, which was developed from computed tomography (CT) images of an average Korean adult male, was employed for Monte Carlo calculation using EGSnrc user-code, developed for the purpose of this study. The SAFs for 32 target organs and tissues from the photon source, uniformly deposited in a total of 37 source organs and tissues, were calculated from KTMAN-2. The results were compared with those for an adult phantom of Oak Ridge National Laboratory (ORNL) and Korean adult stylised phantom. Two major reasons of discrepancy were analysed: (1) racial difference between the Korean and the Caucasian and (2) anatomical difference between stylised and voxel phantoms. When the source organ was identical to the target organ, difference in SAF caused by the difference in target-organ mass between the Korean and the Caucasian phantoms was mainly observed. When the source and target organs were not identical, significant difference in SAF was observed which was mainly attributed to the difference in inter-organ distance and organ shape between voxel and stylised phantoms.

journal_name

Radiat Prot Dosimetry

authors

Lee C,Park S,Lee JK

doi

10.1093/rpd/ncl167

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

360-8

issue

3

eissn

0144-8420

issn

1742-3406

pii

ncl167

journal_volume

123

pub_type

杂志文章
  • Monte Carlo dosimetry for targeted irradiation of individual cells using a microbeam facility.

    abstract::Microbeam facilities provide a unique opportunity to investigate the effects of ionising radiation on living biological cells with a precise control of the delivered dose. This paper describes dosimetry calculations performed at the single-cell level in the microbeam irradiation facility available at the Centre d'Etud...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp003

    authors: Incerti S,Seznec H,Simon M,Barberet P,Habchi C,Moretto P

    更新日期:2009-01-01 00:00:00

  • Detection of primary and secondary cosmic ray particles aboard the ISS using SSNTD stacks.

    abstract::To study the radiation environment inside the International Space Station, solid state nuclear track detector stacks were used. Within the BRADOS experiments, Phase 1, seven stacks were exposed at different locations of the Russian segment 'Zvezda' for 248 days in 2001. It was supposed that the radiation field inside ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci673

    authors: Pálfalvi JK,Akatov Y,Szabó J,Sajó-Bohus L,Eördögh I

    更新日期:2006-01-01 00:00:00

  • Assessment of the Absorbed Dose in the Kidney of Nuclear Nephrology Paediatric Patients using ICRP Biokinetic Data and Monte Carlo Simulations with Mass-Scaled Paediatric Voxel Phantoms.

    abstract::The aim of this work is to use Monte Carlo simulations and VOXEL phantoms to estimate the absorbed dose in paediatric patients (aged from 2 weeks to 16 y), with normal renal function, to whom technetium-99m-dimercaptosuccinic acid (99mTc-DMSA) was administered, for diagnostic renal scintigraphy purposes; and compare t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw096

    authors: Teles P,Mendes M,Zankl M,de Sousa V,Santos AI,Vaz P

    更新日期:2017-04-20 00:00:00

  • Deposition of tritiated water vapour to water surface in an outdoor field.

    abstract::Deposition of tritiated water vapour in the atmosphere to a water surface was studied in an outdoor field, where elevated concentrations of tritiated water vapour existed in the atmosphere over twelve days. Exchange velocities of tritiated water vapour between air and water were evaluated from tritium concentrations i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006425

    authors: Noguchi H,Fukutani S,Yokoyama S,Kinouchi N

    更新日期:2001-01-01 00:00:00

  • NEURAL NETWORK MODELLING OF CARDIAC DOSE CONVERSION COEFFICIENT FOR ARBITRARY X-RAY SPECTRA.

    abstract::In this article, an approach to compute the dose conversion coefficients (DCCs) is described for the computational voxel phantom 'High-Definition Reference Korean-Man' (HDRK-Man) using artificial neural networks (ANN). For this purpose, the voxel phantom was implemented into the Monte Carlo (MC) transport toolkit GEAN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv436

    authors: Kadri O,Manai K

    更新日期:2016-12-01 00:00:00

  • Variability of radiocaesium inventory in Fukushima soil cores from one site measured at different times.

    abstract::The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident has resulted in the deposition of radioactive contamination of soils mainly by (134)Cs and (137)Cs. The contaminated areas are of a great concern since external radiation may lead to significant long-term doses to humans and animals. External dose rate above g...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv276

    authors: Mishra S,Sahoo SK,Arae H,Sorimachi A,Hosoda M,Tokonami S,Ishikawa T

    更新日期:2015-11-01 00:00:00

  • Methods and materials for the measurement of subjective and objective measurements of image quality.

    abstract::The evaluation of medical imaging systems may be performed using both subjective (e.g. high contrast limiting resolution, and low contrast detail detectability), and objective/physical (e.g. characteristic curve, signal-to-noise ratio, modulation transfer function, and Wiener spectra) indices of image quality. For the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006476

    authors: Marsh DM,Malone JF

    更新日期:2001-01-01 00:00:00

  • Secondary neutron doses in proton therapy treatments of ocular melanoma and craniopharyngioma.

    abstract::Monte Carlo simulations were used to assess secondary neutron doses received by patients treated with proton therapy for ocular melanoma and craniopharyngioma. MCNPX calculations of out-of-field doses were done for ∼20 different organs considering realistic treatment plans and using computational phantoms representati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct283

    authors: Farah J,Sayah R,Martinetti F,Donadille L,Lacoste V,Hérault J,Delacroix S,Nauraye C,Vabre I,Lee C,Bolch WE,Clairand I

    更新日期:2014-10-01 00:00:00

  • Calculation and Validation of the Response Matrix for a Neutron Multisphere Spectrometer with an Indium Central Detector.

    abstract::Expansion of accelerator technologies into different application areas brings the need for neutron-field measurements in their vicinity. The measurements of neutron energy spectra and neutron dose rates can be done with the aid of neutron multisphere spectrometers with passive neutron detectors. In addition to the usu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx183

    authors: Vlk P,Pavlovic M

    更新日期:2018-04-01 00:00:00

  • General guidelines for the assessment of internal dose from monitoring data: progress of the IDEAS project.

    abstract::In recent major international intercomparison exercises on intake and internal dose assessments from monitoring data, the results calculated by different participants varied significantly. Based on this experience the need for harmonisation of the procedures has been formulated within an EU 5th Framework Programme res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl132

    authors: Doerfel H,Andrasi A,Bailey M,Blanchardon E,Cruz-Suarez R,Berkovski V,Castellani CM,Hurtgen C,LeGuen B,Malatova I,Marsh J,Stather J,Zeger J

    更新日期:2007-01-01 00:00:00

  • Development of a voxel phantom of Japanese adult male in upright posture.

    abstract::A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm272

    authors: Sato K,Noguchi H,Endo A,Emoto Y,Koga S,Saito K

    更新日期:2007-01-01 00:00:00

  • Entrance surface, organ and effective doses for some of the patients undergoing different types of X ray procedures in Bangladesh.

    abstract::Entrance surface doses (ESDs) were measured for the most common types of X ray procedures, such as chest PA, lumber spine AP, lumber spine lateral, skull AP, skull lateral and pelvis AP in four major hospitals of Dhaka, the capital city of Bangladesh. Organ/tissue doses for 29 organs/tissues and effective doses for th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006549

    authors: Begum Z

    更新日期:2001-01-01 00:00:00

  • Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory.

    abstract::The purpose of the study was to evaluate the dose performance of a flat-panel (FP) and an image intensifier (II) charge coupled device (CCD) digital fluoroscopy X-ray systems newly installed in an Interventional Cardiology (IC) department. Filter entrance dose rate, detector dose rate (during fluoroscopy) and filter e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch344

    authors: Tsapaki V,Kottou S,Kollaros N,Dafnomili P,Kyriakidis Z,Neofotistou V

    更新日期:2004-01-01 00:00:00

  • THE IMPACT OF CIRCADIAN RHYTHMS ON MEDICAL IMAGING AND RADIOTHERAPY REGIMES FOR THE PAEDIATRIC PATIENT.

    abstract::Daily rhythmic changes are found in cellular events in cell cycle, DNA repair, apoptosis and angiogenesis in both normal and tumour tissue, as well as in enzymatic activity and drug metabolism. In this paper, we hypothesize that circadian rhythms need to be considered in radiation protection and optimization in person...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw328

    authors: Forssell-Aronsson E,Quinlan RA

    更新日期:2017-04-01 00:00:00

  • Cellular signal transduction events as a function of linear energy transfer (LET).

    abstract::In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation, the number and size of pATM (S1981) and gamma-H2AX foci were compared in cultures of diploid human fibroblasts after exposure to charged particles of varying species, energ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm086

    authors: Fürweger C,Hajek M,Vana N,Kodym R,Okayasu R

    更新日期:2007-01-01 00:00:00

  • DNA fragments induction in human fibroblasts by radiations of different qualities.

    abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl389

    authors: Esposito G,Belli M,Campa A,Cherubini R,Cuttone G,Dini V,Furusawa Y,Gerardi S,Simone G,Sorrentino E,Tabocchini MA

    更新日期:2006-01-01 00:00:00

  • THE CHALLENGE IN USING THE RETROSPECTIVE ASSESSMENT OF RESIDENTIAL RADON CONCENTRATION.

    abstract::In the present study, the contemporary indoor radon activity concentration and the surface-deposited 210Po activity were measured in 65 Romanian dwellings. The activity of trapped 210Po on the glass surface was measured using the (CR-LR) difference technique. The retrospective radon activity concentration estimated on...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy095

    authors: Dicu T,Burghele BD,Lupulescu D,Cucos A

    更新日期:2018-09-01 00:00:00

  • EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE.

    abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa125

    authors: Krmar M,Milić K,Arsenić I,Hansman J

    更新日期:2020-10-16 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • The impact of automatic wedge filter on photoneutron and photon spectra of an 18-MV photon beam.

    abstract::The effect of an automatic wedge filter on photon and photoneutron spectra of a medical linac was evaluated using the Monte Carlo method. The head of an Elekta SL75/25 was simulated using the MCNPX Monte Carlo code. The photon and photoneutron spectra for open and wedged beams were calculated at the isocentre with a s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp204

    authors: Ghavami SM,Mesbahi A,Mohammadi E

    更新日期:2010-02-01 00:00:00

  • EVALUATION OF SECONDARY DOSE AND CANCER RISK FOR OUT-OF-FIELD ORGAN IN ESOPHAGEAL CANCER IMRT IN A CHINESE HOSPITAL USING ATOM PHANTOM MEASUREMENTS.

    abstract::There have been few studies on the secondary cancer after radiation treatment in Chinese hospitals. This study has measured out-of-field absorbed organ doses from intensity-modulated radiation therapy (IMRT) radiotherapy for esophageal cancer in a Chinese hospital and evaluated the risks of secondary cancer. The dose ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx057

    authors: Qi Y,He L,Wang Z,Liu Y,Liu H,Huo W,Xu XG,Chen Z

    更新日期:2017-12-01 00:00:00

  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D

    更新日期:2004-01-01 00:00:00

  • A micro-gap, air-filled ionisation chamber as a detector for criticality accident dosimetry.

    abstract::A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct323

    authors: Murawski Ł,Zielczyński M,Golnik N,Gryziński MA

    更新日期:2014-10-01 00:00:00

  • Activity concentrations and mean annual effective dose from gamma-emitting radionuclides in the Lebanese diet.

    abstract::Since the primary factor contributing to the internal effective dose in the human organism is contaminated food, the control of radionuclides in food represents the most important means of protection. This study was conducted to determine the levels of the dietary exposure of the Lebanese population to gamma-emitting ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn160

    authors: Nasreddine L,El Samad O,Hwalla N,Baydoun R,Hamzé M,Parent-Massin D

    更新日期:2008-01-01 00:00:00

  • Usability of VTL from natural quartz grains for retrospective dosimetry.

    abstract::To develop retrospective dosimetry of unexpected radiation accident, basic studies on violet thermoluminescence (VTL) phenomena were conducted using natural quartz grains. All VTL glowcurves of as-received samples did not exhibit peaks <250 degrees C, although for artificially irradiated quartz samples there were VTL ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl108

    authors: Fujita H,Hashimoto T

    更新日期:2007-01-01 00:00:00

  • RADIOLOGICAL HAZARD INDICES OF GRANITIC ROCKS USED FOR THE CONSTRUCTION OF BUILDINGS FROM NUBA MOUNTAINS SUDAN.

    abstract::This study was conducted to assess the level of radioactivity and the radiation hazards associated with granite rocks used for construction of buildings. The measurement of radioactivity content of the rock samples was performed with gamma-spectrometry equipped with Nal (TI) detector. From the results obtained in this...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx295

    authors: Fadol N,Idriss H,Salih I,Ragab NA,Osman S,Sam AK

    更新日期:2018-06-01 00:00:00

  • SAR distribution in human beings when using body-worn RF transmitters.

    abstract::This study analyzes the exposure of the human torso to electromagnetic fields caused by wireless body-mounted or handheld devices. Because of the frequency and distance ranges from 30-5800 MHz and 10 to 200 mm, respectively, both near-field and far-field effects are considered. A generic body model and simulations of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm377

    authors: Christ A,Samaras T,Neufeld E,Klingenböck A,Kuster N

    更新日期:2007-01-01 00:00:00

  • SIMULATION OF OSL AND TLD DOSEMETER RESPONSE FOR THE DEVELOPMENT OF NEW EXTREMITY DOSEMETERS.

    abstract::The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy299

    authors: Hoedlmoser H,Brönner J,Bandalo V,Wahl F,Greiter MB

    更新日期:2019-12-23 00:00:00

  • CT equipment and performance issues: radiation protection 162.

    abstract::Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in pa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs285

    authors: Edyvean S

    更新日期:2013-02-01 00:00:00

  • The neutron component of two high-energy photon reference fields.

    abstract::The 4.4 MeV photon reference field described in ISO 4037 is produced by the (12)C(p,p')(12)C (E(x) = 4.4389 MeV) reaction using a thick elemental carbon target and a proton beam with an energy of 5.7 MeV. The relative abundance of the isotope (13)C in elemental carbon is 1.10%. Therefore, the 4.4 MeV photon field is c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm083

    authors: Röttger S,Schäler K,Behrens R,Nolte R,Wissmann F

    更新日期:2007-01-01 00:00:00