Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.

Abstract:

:In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron dose equivalent rate was below the lower limit of detection of a CR-39 etched track detector and below 0.14 +/- 0.02 muSv h(-1) with a proportional counter, which is consistent, within the uncertainties, with natural background. The photon dose equivalent rate was also measured to be below background levels (0.1 muSv h(-1)) using an ionisation chamber and an optically stimulated luminescence dosemeter. A Monte Carlo simulation of neutron transport through the accelerator vault was performed to validate measured values and determine the thermal-energy to low-energy neutron component. Monte Carlo results showed that the dose equivalent rate from fast neutrons was reduced by a factor of 100,000 after attenuation through the vault wall, and the thermal-energy neutron dose equivalent rate would be an additional factor of 1000 below that of the fast neutrons. Based on these findings, the shielding installed in this facility is sufficient for the use of at least 5.0 mg of 252Cf.

journal_name

Radiat Prot Dosimetry

authors

Melhus CS,Rivard MJ,Kurkomelis J,Liddle CB,Massé FX

doi

10.1093/rpd/nch473

keywords:

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

428-37

issue

4

eissn

0144-8420

issn

1742-3406

pii

nch473

journal_volume

113

pub_type

杂志文章
  • Development of a retrospective/fortuitous accident dosimetry service based on OSL of mobile phones.

    abstract::Work is presented on the development of a retrospective/fortuitous accident dosimetry service using optically stimulated luminescence of resistors found in mobile phones to determine the doses of radiation to members of the public following a radiological accident or terrorist incident. The system is described and dis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu370

    authors: Smith RW,Eakins JS,Hager LG,Rothkamm K,Tanner RJ

    更新日期:2015-04-01 00:00:00

  • Variation of radiocesium concentrations in cedar pollen in the Okutama area since the Fukushima Daiichi Nuclear Power Plant accident.

    abstract::Due to releases of radionuclides in the Fukushima Daiichi Nuclear Power Plant accident, radiocesium ((134)Cs and (137)Cs) has been incorporated into large varieties of plant species and soil types. There is a possibility that radiocesium taken into plants is being diffused by pollen. Radiocesium concentrations in ceda...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv248

    authors: Tsuruoka H,Inoue K,Sakano Y,Hamada M,Shimizu H,Fukushi M

    更新日期:2015-11-01 00:00:00

  • Thermoluminescence properties of KCl(1-X)KBrX:Pb2+ mixed crystals.

    abstract::A study is presented of the thermoluminescence (TL) of phosphors based on potassium halides doped with divalent lead, such as KCl:Pb2+, KBr:Pb2+ and the crystalline series KCl(1-X)Br(X):Pb2+. The defects in the crystals generated by irradiation have been investigated as well as the trapping and room temperature recomb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005913

    authors: Cruz-Zaragoza E,Meléndrez R,Chernov V,Barboza-Flores M,Piters TM,Hernández JA,Murrieta HS

    更新日期:2002-01-01 00:00:00

  • VISUALIZATION OF THE DNA REPAIR PROCESS IN MAMMALIAN CELLS TRANSFECTED WITH EGFP-EXPRESSING PLASMID DNA AFTER EXPOSURE TO X-RAYS IN VITRO.

    abstract::To investigate the repair process of DNA damage induced by ionizing radiation in isolation from various types of cytoplasmic damage, we transfected X-irradiated enhanced green fluorescent protein (EGFP)-expressing plasmid DNA into non-irradiated mammalian cells using lipofectamine. The repair kinetics of the irradiate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy241

    authors: Nakaue H,Obata Y,Kaminaga K,Akimitsu N,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Induced radioactivity in the ESRF storage ring.

    abstract::The new French radiation protection legislation requires the definition of the zoning of accelerator facilities with respect to radioactive waste. This activation inside the ESRF 6 GeV storage ring is essentially due to photonuclear reactions. This paper describes the first results of Monte Carlo calculations that wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci070

    authors: Berkvens P

    更新日期:2005-01-01 00:00:00

  • On the equivalence of propane-based tissue-equivalent gas and liquid water with respect to the ionisation-yield formation by electrons and alpha-particles.

    abstract::One encouraging way, at present, to put the investigation of ionisation-yield formation in sub-cellular structures or, at least, in nanometric volumes of liquid water on an experimental basis is the use of highly sophisticated counters filled with gases at low operating pressure to simulate target volumes a few nm in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006818

    authors: Grosswendt B

    更新日期:2002-01-01 00:00:00

  • Radon in underground waters as a natural analogue to study the escape of CO2 in geological repositories.

    abstract::Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv232

    authors: Martín Sánchez A,Ruano Sánchez AB,de la Torre Pérez J,Jurado Vargas M

    更新日期:2015-11-01 00:00:00

  • The present ICRP protection quantitites are seriously flawed. Opposing the proposition.

    abstract::Our debaters have agreed to defend positions that appear to be diametrically opposed; nevertheless, they have acknowledged some common ground. Although it was not explicitly stated, they would no doubt agree that workers and the public are adequately protected by our present system of radiation regulations. Our debate...

    journal_title:Radiation protection dosimetry

    pub_type: 评论,杂志文章

    doi:

    authors: Edwards AA

    更新日期:2003-01-01 00:00:00

  • MEASUREMENTS OF RADIATION EXPOSURE OF RADIOGRAPHY STUDENTS DURING THEIR CLINICAL TRAINING USING THERMOLUMINESCENT DOSIMETRY.

    abstract::Radiation dose monitoring for radiography students during clinical training is necessary to demonstrate the extent of radiation protection issues present, as well as to instill in them an awareness of safe practices that they will carry with them throughout their careers. The study assess the radiation dose incurred b...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx261

    authors: Abuzaid MM,Elshami W,Steelman C

    更新日期:2018-05-01 00:00:00

  • The TSL neutron beam facility.

    abstract::A new quasi-monoenergetic neutron beam facility has been constructed at The Svedberg Laboratory (TSL) in Uppsala, Sweden. Key features include a neutron energy range of 11-175 MeV, high fluxes, user flux control, flexible neutron field size and shape, and spacious and easily accessible user area. The first results of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm006

    authors: Prokofiev AV,Blomgren J,Byström O,Ekström C,Pomp S,Tippawan U,Ziemann V,Osterlund M

    更新日期:2007-01-01 00:00:00

  • EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE.

    abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa125

    authors: Krmar M,Milić K,Arsenić I,Hansman J

    更新日期:2020-10-16 00:00:00

  • Application of the high-temperature ratio method for evaluation of the depth distribution of dose equivalent in a water-filled phantom on board space station Mir.

    abstract::A water-filled tissue equivalent phantom with a diameter of 35 cm was developed at the Institute for Biomedical Problems. Moscow. Russia. It contains four channels perpendicular to each other, where dosemeters can be exposed at different depths. Between May 1997 and February 1999 the phantom was installed at three dif...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005923

    authors: Berger T,Hajek M,Schöner W,Fugger M,Vana N,Akatov Y,Shurshakov V,Arkhangelsky V,Kartashov D

    更新日期:2002-01-01 00:00:00

  • COMPARISON OF THE NEUTRON ENERGY RESPONSE OF TWO DIFFERENT TLD ALBEDO DOSEMETERS.

    abstract::Albedo dosemeters remain the most used dosemeters in neutron individual monitoring. In Brazil, most of the neutron occupational fields are from radionuclide sources, often without any moderation, where albedo dosemeters have poor energy response. The purpose of this work is to compare the HP(10) energy response of the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx256

    authors: Freitas BM,da Silva AX,Pereira WW,Mauricio CLP

    更新日期:2018-08-01 00:00:00

  • Shielding design calculations for beam dump facility of KOMAC.

    abstract::A project to construct the Korea Multi-purpose Accelerator Complex (KOMAC) is currently underway targeting a high-intensity proton beam with an average current of 4.8 mA. As for the first stage of construction, a 20 MeV linac is planned to be built by 2007 and additional DTL sections will be added to increase the prot...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci066

    authors: Cho YS,Lee YO,Chang J

    更新日期:2005-01-01 00:00:00

  • Protection from radon exposure at home and at work in the directive 2013/59/Euratom.

    abstract::In recent years, international organisations involved in radiation protection and public health have produced new guidance, recommendations and requirements aiming better protection from radon exposure. These organisations have often worked in close collaboration in order to facilitate the establishment of harmonised ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu101

    authors: Bochicchio F

    更新日期:2014-07-01 00:00:00

  • Neutron and photon fields in the BNCT room with closed beam shutters.

    abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci112

    authors: Marek M,Viererbl L

    更新日期:2005-01-01 00:00:00

  • New diagnostic reference level for full-field digital mammography units.

    abstract::The diagnostic reference level (DRL) has generally been defined as the 75th percentile of the distributions of mean doses observed on a sample of standard-sized patients, but for mammography, the 95th percentile has been used. In this study, the 75th and 95th percentiles are estimated for 26 full-field digital mammogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct136

    authors: Hauge IH,Bredholt K,Olerud HM

    更新日期:2013-12-01 00:00:00

  • Retrospective dosimetry related to chronic environmental exposure.

    abstract::Radioactive contamination of the environment occurred in the early fifties as a result of the releases from the Mayak plutonium production complex (Southern Urals, Russia). The releases of liquid wastes into the Techa river resulted in chronic exposure of 30,000 residents of the riverside communities. Since 1951 90Sr ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032381

    authors: Degteva MO,Kozheurov VP,Tolstykh EI

    更新日期:1998-01-01 00:00:00

  • Non-targeted effects of radiation: bystander responses in cell and tissue models.

    abstract::The standard paradigm for radiation effects in cellular systems has involved direct damage to DNA and in particular, DNA double strand breaks as the triggering lesions leading to mutation, cell death and transformation. Recently, however, a growing body of evidence has reported non-targeted effects, which are not a di...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006768

    authors: Prise KM,Belyakov OV,Newman HC,Patel S,Schettino G,Folkard M,Michael BD

    更新日期:2002-01-01 00:00:00

  • Influence of the uniformity of the slab phantom illumination on the calibration of personal dosemeters.

    abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq036

    authors: Ankerhold U,Ambrosi P

    更新日期:2010-06-01 00:00:00

  • A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    abstract::The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq002

    authors: Faulkner K,Järvinen H,Butler P,McLean ID,Pentecost M,Rickard M,Abdullah B

    更新日期:2010-04-01 00:00:00

  • A very low-background gamma-ray counting facility in the Baradello underground laboratory.

    abstract::An underground station for the measurement of low-level radioactivity is in operation in Northern Italy in the town of Como under the Baradello hill. The rock cover is -300 m water equivalent. This paper reports about the preliminary measurements carried out to characterise the site of the Baradello hill and the insta...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci163

    authors: Pellicciari M,Fascilla A,Giuliani A,Pedretti M,Cesana A,Garlati L,Terrani M,Raselli GL

    更新日期:2005-01-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • Dosimetric monitoring in Ukraine--present status and path to the future.

    abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl128

    authors: Chumak V,Boguslavskaya A

    更新日期:2007-01-01 00:00:00

  • Using simple mathematical functions to simulate pathological structures--input for digital mammography clinical trial.

    abstract::In this study a set of structures has been simulated to represent a range of clinically relevant breast cancer mammographic lesions including solid tumours and microcalcifications. All structures have been created using simple random-based mathematical functions and have been inserted into a subset of digital mammogra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch552

    authors: Ruschin M,Tingberg A,Båth M,Grahn A,Håkansson M,Hemdal B,Andersson I

    更新日期:2005-01-01 00:00:00

  • Correlation of patient maximum skin doses in cardiac procedures with various dose indicators.

    abstract::In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn247

    authors: Domienik J,Papierz S,Jankowski J,Peruga JZ,Werduch A,Religa W

    更新日期:2008-01-01 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • Insights into the sites of X ray and neutron induced chromosomal aberrations in human lymphocytes using COBRA-MFISH.

    abstract::A multi-colour fluorescence in situ hybridisation (MFISH) assay has been developed, for simultaneous visualisation of all human chromosomes in 24 different colours. This assay is based on the simultaneous use of combinatorial labelling and ratio labelling, the so called combined binary ratio labelling (COBRA). This te...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006758

    authors: Darroudi F,Bezrookove V,Fomina J,Mesker WE,Wiegant JC,Raap AK,Tanke HJ

    更新日期:2002-01-01 00:00:00

  • TWO NEW SINGLE-EXPOSURE, MULTI-DETECTOR NEUTRON SPECTROMETERS FOR RADIATION PROTECTION APPLICATIONS IN WORKPLACE MONITORING.

    abstract::This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw349

    authors: Gómez-Ros JM,Bedogni R,Bortot D,Domingo C,Esposito A,Introini MV,Lorenzoli M,Mazzitelli G,Moraleda M,Pola A,Sacco D

    更新日期:2017-04-01 00:00:00

  • DEVELOPMENT AND APPLICATION OF SOLID FORMS OF CaSO4:Dy THERMOLUMINESCENT DOSEMETERS IN RADIATION PROTECTION DOSIMETRY-A REVIEW.

    abstract::CaSO4:Dy is a reliable high-sensitive themoluminescent phosphor useful for low-level and high-level radiation measurements as it exhibits fading free linear dose response with a single glow peak at ~230°C in these dose regions. For large-scale radiation protection dosimetry service, it is embedded in Teflon matrix wit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncx287

    authors: Lakshmanan A

    更新日期:2018-10-01 00:00:00