Abstract:
:The present paper shows methods to suppress radon emanation from artificial porous materials such as phosphorous fertiliser or diatomaceous earth with a small amount of radium. The basic concept of suppression is making the radon emanation mechanism 'null', which comes from the fact that recoil is the main mechanism of radon emanation at room temperature. Nullifying may be done through removal of water in the pore volume by heating and through removal of pores by melting or filling with sulphur. These radon emanation suppression methods were tried for phosphorous fertiliser and diatomaceous earth with a small amount of radium. The melting method was the most effective of all. Sustainability of these methods was also studied. The melting method was the most sustainable. The heating method was also sustainable for diatomaceous earth in spite of a long-term immersion in water.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Sasaki T,Gunji Y,Okuda Tdoi
10.1093/rpd/ncm420subject
Has Abstractpub_date
2007-01-01 00:00:00pages
75-84issue
2eissn
0144-8420issn
1742-3406pii
ncm420journal_volume
124pub_type
杂志文章abstract::New imaging technologies utilising X rays and radiopharmaceuticals are continuously under development. The benefit of computed tomography (CT) has been so dramatic that there is a tendency to overuse it and not to place enough efforts into optimisation of the technique. It is also now more and more common to combine t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncr261
更新日期:2011-09-01 00:00:00
abstract::Spectrometric and dosimetric measurements were made around a cask containing spent fuel and a cask containing high-level radioactive waste at the Swiss intermediate waste and spent fuel storage facility. A Bonner sphere spectrometer, an LB 6411 neutron monitor and an Automess Szintomat 6134A were used to characterise ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm216
更新日期:2007-01-01 00:00:00
abstract::The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculat...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch508
更新日期:2005-01-01 00:00:00
abstract::In this paper, the results aimed at assessing the performance of two varieties of LiF detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) in photon fields relatively to reproducibility, detection threshold and angular dependence as defined in the ISO 12794 standard are presented. The fading properties and the limit of detection wer...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq366
更新日期:2011-03-01 00:00:00
abstract::An assessment of multiple biomarkers from radiation casualties undergoing limited- or full-supportive care including treatment with filgrastim is critical to develop rapid and effective diagnostic triage strategies. The efficacy of filgrastim with full-supportive care was compared with results with limited-supportive ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw176
更新日期:2016-12-01 00:00:00
abstract::In response to reactive oxygen species (ROS) or electrophiles, the transcription factor nuclear factor-erythroid 2 (NF-E2)-related factor 2 (Nrf2) rapidly translocates into the nucleus and induces the expression of various antioxidant genes, such as heme oxygenase-1 (HO-1). Low linear energy transfer (LET) ionising ra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs201
更新日期:2012-11-01 00:00:00
abstract::When neutron survey metres are calibrated in neutron fields, the results for room- and air-scattered neutrons vary according to the distance from the source and the size, shape and construction of the neutron calibration room. ISO 8529-2 recommends four approaches for correcting these effects: the shadow-cone method, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx219
更新日期:2018-08-01 00:00:00
abstract::There are several occurrences of thermal waters in the south-eastern part of Serbia, which are originating from igneous and metamorphic rocks. These waters are mainly used in balneology, but some of them are used for drinking purposes and in water supply to heat buildings, for greenhouses and to irrigate land. In this...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu094
更新日期:2014-07-01 00:00:00
abstract::The objective of this work is to obtain fluence to effective dose conversion coefficients for neutron point sources, using the GEANT4 toolkit. These calculations aim to investigate the aspects of neutron transport in the human body through Monte Carlo simulation using the International Commission on Radiological Prote...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx286
更新日期:2018-08-01 00:00:00
abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs260
更新日期:2013-05-01 00:00:00
abstract::In many exposure scenarios to ionising radiation, the dose rate is not constant. Despite this, most in vitro studies aimed at investigating the effects of ionising radiation are carried out exposing samples at constant dose rates. Consequently, very little data exist on the biological effects of exposures to changing ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr092
更新日期:2012-02-01 00:00:00
abstract::The measurement of air samples may be used to assess risks of internal exposures, either by the use of workplace static air samplers (SAS) or personal air samplers (PAS). These measurements need to incorporate information on the physical and chemical nature of the aerosol, and the relationship between the sampled and ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncm397
更新日期:2007-01-01 00:00:00
abstract::A thermoluminescence (TL) study relevant to radiation dosimetry has been carried out for X-ray irradiated biotite mineral under un-annealed and different annealed (473, 573, 673 and 773 K) conditions. Some significant variations in dosimetric characteristics have been observed with annealing treatment. Due to generati...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu289
更新日期:2015-04-01 00:00:00
abstract::This study identified occupational factors associated with radiation exposure in Korea. Survey data of 16 037 workers from 2016 to 2017, including lifestyle factors and occupational characteristics, were combined with the National Dose Registry. Higher average annual doses were observed in groups exhibiting health ris...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa019
更新日期:2020-07-07 00:00:00
abstract::Three-dimensional Monte Carlo shielding analyses are conducted on the ITER Neutral Beam Injection (NBI) duct for the nuclear and bremsstrahlung radiation. The detailed distribution is evaluated about the nuclear heating rate and surface heat load of the NBI duct wall by the neutron and photon transport calculation. Th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci195
更新日期:2005-01-01 00:00:00
abstract::In reviewing the tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdo...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006197
更新日期:2003-01-01 00:00:00
abstract::The reliability of equivalent-dose determinations on quartz made with the single-aliquot regenerative-dose (SAR) protocol is examined using a suite of sedimentary samples for which the equivalent dose is expected to be >200 Gy. Experiments on one sample were used to evaluate the precision obtained using the standard m...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006004
更新日期:2002-01-01 00:00:00
abstract::This study aims to describe current risk management practices and policies across the world in relation to personal exposures from devices emitting radiofrequency fields, environmental exposures from fixed installations and exposures in the work environment. Data from 86 countries representing all WHO regions were col...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu324
更新日期:2015-04-01 00:00:00
abstract::The activity concentration of natural and anthropogenic radionuclides was determined in different vegetable samples, and foods derived from animal origin, from different locations in the four cities of Southern Tunisia, where large-scale phosphate industries are operating. The aim of the studies was to establish a bas...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy208
更新日期:2019-08-01 00:00:00
abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci208
更新日期:2005-01-01 00:00:00
abstract::New radiophotoluminescence (RPL) phosphate glass containing (6)Li was successfully made from the powder of NaPO(3), Al(PO(3))(3), LiOH, HPO(3) and AgCl. The ternary diagram of NaPO(3)-Al(PO(3))(3)-LiPO(3) has clarified the region where satisfactory RPL characteristics of the glass are kept up. The synthesised phosphat...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq552
更新日期:2011-03-01 00:00:00
abstract::Individual genetic variation can influence susceptibility to the carcinogenic effects of many environmental carcinogens. In radiation-exposed populations those individuals with a greater genetically determined susceptibility would be at greater risk of developing cancer. To include this modification of risk into radia...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006778
更新日期:2002-01-01 00:00:00
abstract::Radon is one of the noble gases, which are chemically inert and do not make any reactants under normal conditions. In this experiment we demonstrated an enigmatic reaction between radon and fluorine when a corona discharge is used as a promoter. Distinctive changes in radon concentrations were caused by the discharge ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci311
更新日期:2005-01-01 00:00:00
abstract::The EC (European Council) Directive on radiation protection of patients requires that criteria for acceptability of equipment in diagnostic radiology, nuclear medicine and radiotherapy be established throughout the member states. This study reviews the background to this requirement and to its implementation in practi...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncs295
更新日期:2013-02-01 00:00:00
abstract::Accident dosimetry aims to evaluate the unplanned radiation doses delivered to individuals through one of the objects exist in the area of the accident. The gamma dose response of free radicals generated in irradiated aspartame tablets and its usability for emergency dosimetry was studied. EPR spectra of unirradiated ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp293
更新日期:2010-06-01 00:00:00
abstract::The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the In...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq155
更新日期:2010-09-01 00:00:00
abstract::Annual effective dose due to the consumption of 40K, 226Ra, 228Ra and 228Th was estimated from high-resolution gamma spectrometry, food consumption data for the inhabitants of Rio de Janeiro City and dose coefficients published by the ICRP 119. A total of 31 samples of cereals, grains, vegetables, flours, liquid and p...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx310
更新日期:2018-10-01 00:00:00
abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq117
更新日期:2010-08-01 00:00:00
abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci627
更新日期:2006-01-01 00:00:00
abstract::Estimating organ absorbed doses in consideration of person-specific parameters is important for radiation protection in diagnostic nuclear medicine. This study proposes a straightforward method for estimating the organ dose that reflects a specific organ mass by scaling the reference organ dose using the inverse ratio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa058
更新日期:2020-07-24 00:00:00