Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

Abstract:

:The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have performed thermoluminescence dosimetry (TLD) audits to verify the calibration of the beams by TL powder, but TL pellets were used in this study because the element correction factor (ECF), defined as the factor to correct the variations that all TL dosemeters cannot be manufactured to have exactly the same TL efficiency, for each TL pellet could be accurately derived and be handled conveniently when compared with the powder. Also several works for the energy response of the TLDs were done for the low-energy photon beams up to 60Co, but they will be extended in this experiment to the high photon energies (up to 20 MV), which are widely used in the therapy level of a radiation. The PTW 30006 ionisation chamber was calibrated by the Korea primary standards to establish the air-kerma rates and the TL pellets were irradiated in a specially designed waterproof pellet holder in a water phantom (30 x 30 x 30 cm3) just like the IAEA postal audits programme. This result was compared with that of another type of phantom [10 (W) x 10 (L) x 10 (H) cm3 PMMA Perspex phantom for the 60Co and 6 MV photon, and 10 x 10 x 20 (H) cm3 for the 10 and 21 MV photon] for its convenient use and easy handling and installation in a hospital. The results show that the differences of the responses for the water phantom and PMMA Perspex phantom were negligible, which is contrary to the general conception that a big difference would be expected. For an application of these results to verify the therapy beams, an appropriate energy correction factor should be applied to the energies and phantom types in use.

journal_name

Radiat Prot Dosimetry

authors

Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

doi

10.1093/rpd/nci627

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

353-6

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

nci627

journal_volume

119

pub_type

杂志文章
  • Dose assessment for ingestion of a 330 kilobecquerel 60Co hot particle.

    abstract::On leaving the irradiated fuel bay at Pickering A nuclear power station, a worker triggered a whole body monitor alarm with activity in or on his head, and despite careful decontamination techniques he subsequently swallowed a hot particle. Over the next 3 d, the radioactivity was tracked through the body. It was then...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm256

    authors: Whillans DW,Chase WJ,Wolodarsky WH

    更新日期:2007-01-01 00:00:00

  • Hearing aids' electromagnetic immunity to environmental RF fields.

    abstract::In this work, the electromagnetic interference on hearing aids was evaluated. Electromagnetic (EM) immunity tests on different types of hearing aids were carried out, using signals of intensity and modulation comparable to those present in the environment. The purpose of this work is to characterise the interference, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch052

    authors: Facta S,Benedetto A,Anglesio L,d'Amore G

    更新日期:2004-01-01 00:00:00

  • Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

    abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch013

    authors: Jönsson H,Mattsson S

    更新日期:2004-01-01 00:00:00

  • STRUCTURAL ANALYSIS OF DNA REPAIR PROTEIN XRCC4 APPLYING CIRCULAR DICHROISM IN AN AQUEOUS SOLUTION.

    abstract::We applied circular dichroism (CD) spectral analysis to obtain the secondary structure of the DNA repair protein XRCC4, with a focus on its C-terminus. Using synchrotron radiation as a light source across a wide range of wavelengths, including vacuum ultraviolet (UV) light from 180 to 200 nm and UV light from 200 to 2...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy275

    authors: Nishikubo K,Izumi Y,Matsumoto Y,Fujii K,Matsuo K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Response of silicon diode dosemeters to scattered radiation from megavoltage photon beams.

    abstract::Dose response effects of diodes due to the high atomic number of silicon relative to water are investigated. While quality chances in the primary component of a megavoltage beam with depth are minimal. Compton scattered photons are shown to have a substantial effect on the quality leading to their enhanced absorption ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006014

    authors: Yin Z,Hugtenburg RP,Beddoe AH

    更新日期:2002-01-01 00:00:00

  • Assessment of natural radioactivity and the associated hazards in Iranian cement.

    abstract::This paper presents the finding of a study undertaken to determine natural radioactivity and associated hazards in local types of cement in Iran. A total of 42 samples were collected from various manufacturers and suppliers and analysed using a shielded HPGe gamma-ray spectrometer. The specific activities of 232Th, 22...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl549

    authors: Fathivand AA,Amidi J

    更新日期:2007-01-01 00:00:00

  • Practical application of the ICRP Human Respiratory Tract Model.

    abstract::The ICRP Publication 66 Human Respiratory Tract Model (HRTM) has been applied to calculate dose coefficients and bioassay functions using default values of parameters relating to the material and the subjects. The ICRP Task Group on Internal Dosimetry (INDOS) has developed a guidance document on application of the HRT...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006324

    authors: Bailey MR,Ansoborlo E,Guilmette RA,Paquet F

    更新日期:2003-01-01 00:00:00

  • Issues, considerations and recommendations on emergency preparedness for vulnerable population groups.

    abstract::The Workshop on Emergency Preparedness for Vulnerable Population Groups was held on 2 and 3 March 2009 in Ottawa, ON, Canada. The purpose of the workshop was to enhance communications within the emergency community response network and to identify the needs and gaps of emergency preparedness against chemical, biologic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp083

    authors: Chen J,Wilkinson D,Richardson RB,Waruszynski B

    更新日期:2009-06-01 00:00:00

  • Analysis of radon concentration in drinking water in Baoji (China) and the associated health effects.

    abstract::This paper presents the results of radon concentration measurements in drinking water from the municipal water supply system and private wells located in Baoji, China. The measurements were carried out on 69 samples. The mean values of tap water and well water were found to be 12 kBq m(-3) with a maximum of 18 kBq m(-...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl048

    authors: Xinwei L

    更新日期:2006-01-01 00:00:00

  • Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry.

    abstract::The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al(2)O(3):C,Mg) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm058

    authors: Sykora GJ,Akselrod MS,Salasky M,Marino SA

    更新日期:2007-01-01 00:00:00

  • IDACstar: A MCNP Application to Perform Realistic Dose Estimations from Internal or External Contamination of Radiopharmaceuticals.

    abstract::A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation dose calculations using complex voxel simulations. To test the program, two irradiation situations were simulated, one hypothetical contamination case with 600 MBq of 99mTc and one ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw221

    authors: Ören Ü,Hiller M,Andersson M

    更新日期:2017-04-28 00:00:00

  • Estimation of absorbed doses from paediatric cone-beam CT scans: MOSFET measurements and Monte Carlo simulations.

    abstract::The purpose of this study was to establish a dose estimation tool with Monte Carlo (MC) simulations. A 5-y-old paediatric anthropomorphic phantom was computed tomography (CT) scanned to create a voxelised phantom and used as an input for the abdominal cone-beam CT in a BEAMnrc/EGSnrc MC system. An X-ray tube model of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp257

    authors: Kim S,Yoshizumi TT,Toncheva G,Frush DP,Yin FF

    更新日期:2010-03-01 00:00:00

  • A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

    abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm462

    authors: Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

    更新日期:2008-01-01 00:00:00

  • ANALYSIS BY SCANNER OF TRACKS PRODUCED BY RADON ALPHA PARTICLES IN CR-39 DETECTORS.

    abstract::The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa140

    authors: Sabbarese C,Ambrosino F,Roca V

    更新日期:2020-11-27 00:00:00

  • Radiation dose to premature new-borns in the Belgian neonatal intensive care units.

    abstract::In the neonatal intensive care units (NICU), premature new-borns may be exposed to important doses. Because of their increased radiosensitivity and longer life expectancy, dose optimisation is of importance. The present study aimed at evaluating the dose of the most common radiographs in the Belgian NICU. Entrance sur...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct184

    authors: Dabin J,Struelens L,Vanhavere F

    更新日期:2014-01-01 00:00:00

  • Magnetic field tracking with MCNP5.

    abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci048

    authors: Bul JS,Hughes HG,Walstrom PL,Zumbro JD,Mokhov NV

    更新日期:2005-01-01 00:00:00

  • MCNPX CALCULATIONS OF SPECIFIC ABSORBED FRACTIONS IN SOME ORGANS OF THE HUMAN BODY DUE TO APPLICATION OF 133Xe, 99mTc and 81mKr RADIONUCLIDES.

    abstract::Monte Carlo simulations were performed to evaluate treatment doses with wide spread used radionuclides 133Xe, 99mTc and 81mKr. These different radionuclides are used in perfusion or ventilation examinations in nuclear medicine and as indicators for cardiovascular and pulmonary diseases. The objective of this work was ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx181

    authors: Jovanovic Z,Krstic D,Nikezic D,Ros JMG,Ferrari P

    更新日期:2018-03-01 00:00:00

  • Microdosimetric modelling of the response of thermoluminescence detectors to low- and high-LET ionising radiation.

    abstract::The microdosimetric one hit detector model was applied to calculate the dose response, energy response and relative thermoluminescence (TL) efficiency, eta, of high sensitive LiF:Mg,Cu,P and Al(2)O(3):C detectors after their irradiations by X rays, gamma rays, beta electrons and heavy charged particles (HCP). Microdos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl467

    authors: Olko P,Bilski P,Budzanowski M,Czopyk L,Swakon J,Waligorski MP

    更新日期:2006-01-01 00:00:00

  • Radon concentration measurements in bituminous coal mines.

    abstract::Radon measurements were carried out in Kozlu, Karadon and Uzülmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch449

    authors: Fisne A,Okten G,Celebi N

    更新日期:2005-01-01 00:00:00

  • Comparison of results from quality control of physical parameters and results from clinical evaluation of mammographic images for the mammography screening facilities in Poland.

    abstract::The material for this study comprised control protocols from 248 mammography screening facilities, prepared by physicists employed at 16 Regional Coordinating Centres and the results from the clinical evaluation of mammographic images in 248 facilities in Poland. All mammograms were evaluated independently by three ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncr321

    authors: Fabiszewska E,Grabska I,Jankowska K,Wesolowska E,Bulski W

    更新日期:2011-09-01 00:00:00

  • Biokinetics of radionuclides and treatment of accidental intakes.

    abstract::This paper describes the objectives and reviews the progress of EULEP Working Party 5, convened under the auspices of the European Union's Fifth Framework Programme, to 'cluster' two EU-supported contracts, Biokinetics and Dosimetry of Internal Contamination (BIODOS (EU Contract FIS5-1999-00214)) and Radionuclide Biok...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006318

    authors: Taylor DM,Stradling GN,Ménétrier F

    更新日期:2003-01-01 00:00:00

  • Reliability of the ICRP'S dose coefficients for members of the public: IV. basis of the human alimentary tract model and uncertainties in model predictions.

    abstract::The biokinetic and dosimetric model of the gastrointestinal (GI) tract applied in current documents of the International Commission on Radiological Protection (ICRP) was developed in the mid-1960s. The model was based on features of a reference adult male and was first used by the ICRP in Publication 30, Limits for In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl104

    authors: Leggett R,Harrison J,Phipps A

    更新日期:2007-01-01 00:00:00

  • Evaluation of occupational exposure to naturally occurring radioactive materials in the Iranian ceramics industry.

    abstract::Zircon contains small amounts of uranium, thorium and radium in its crystalline structure. The ceramic industry is one of the major consumers of zirconium compounds that are used as an ingredient at ∼10-20 % by weight in glaze. In this study, seven different ceramic factories have been investigated regarding the prese...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq441

    authors: Fathabadi N,Farahani MV,Amani S,Moradi M,Haddadi B

    更新日期:2011-06-01 00:00:00

  • Cellular signal transduction events as a function of linear energy transfer (LET).

    abstract::In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation, the number and size of pATM (S1981) and gamma-H2AX foci were compared in cultures of diploid human fibroblasts after exposure to charged particles of varying species, energ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm086

    authors: Fürweger C,Hajek M,Vana N,Kodym R,Okayasu R

    更新日期:2007-01-01 00:00:00

  • Determination of committed effective doses to skin due to ²³⁸U, ²³²Th and ²²²Rn from the application of various Moroccan black soap (Saboun Beldi) samples by members of the general public.

    abstract::(238)U, (232)Th, (222)Rn and (220)Rn concentrations were measured inside various Moroccan black soap samples widely used by the Moroccan population in traditional baths (Hammans) by using both CR-39 and LR-115 type II solid state nuclear track detectors. The measured (238)U, (232)Th, (222)Rn and (220)Rn concentrations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq275

    authors: Misdaq MA,Outeqablit K

    更新日期:2010-12-01 00:00:00

  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00

  • Thorium isotopic analysis by alpha spectrometry.

    abstract::The technique of alpha spectrometry is used to detect alpha particles and to determine their energy. In this way the technique is able to provide simultaneously quantitative information (i.e. the activity) and qualitative information (the identity) on any radionuclide that emits an alpha particle. The longer-lived nat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006646

    authors: Gingell T

    更新日期:2001-01-01 00:00:00

  • Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

    abstract::Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl144

    authors: Falcão RC,Facure A,Silva AX

    更新日期:2007-01-01 00:00:00

  • Measurement of neutron dose with an organic liquid scintillator coupled with a spectrum weight function.

    abstract::A dose evaluation method for neutrons in the energy range of a few MeV to 100 MeV has been developed using a spectrum weight function (G-function), which is applied to an organic liquid scintillator of 12.7 cm in diameter and 12.7 cm in length. The G-function that converts the pulse height spectrum of the scintillator...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006071

    authors: Kim E,Endo A,Yamaguchi Y,Yoshizawa M,Nakamura T

    更新日期:2002-01-01 00:00:00

  • AUTOMATIC BRAIN DOSE ESTIMATION IN COMPUTED TOMOGRAPHY USING PATIENT DICOM IMAGES.

    abstract::This study aims to develop an Automatic Brain Dose Estimation (ABDE) methodology for head computed tomography examinations. The ABDE is to be applied first to an anthropomorphic Alderson phantom to obtain a Correction factor (Cf) between the ABDE and the direct absorbed brain dose using dosemeters positioned within th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa006

    authors: Gharbi S,Labidi S,Mars M

    更新日期:2020-07-02 00:00:00