Development of thermal neutron-sensitive glass dosemeter containing lithium.

Abstract:

:New radiophotoluminescence (RPL) phosphate glass containing (6)Li was successfully made from the powder of NaPO(3), Al(PO(3))(3), LiOH, HPO(3) and AgCl. The ternary diagram of NaPO(3)-Al(PO(3))(3)-LiPO(3) has clarified the region where satisfactory RPL characteristics of the glass are kept up. The synthesised phosphate glass indicated good RPL characteristics on the condition that the content of LiPO(3) was below 10 wt%. Gamma-ray irradiation experiments showed that the newly synthesised phosphate glass had satisfactory linearity and wide dynamic range in dose measurement and low variation in sensitivity. It was confirmed from thermal neutron irradiation experiments that a pair of the newly synthesised phosphate glass containing enriched (6)Li and (7)Li, or (n)Li and enriched (7)Li could be effectively used for the evaluation of thermal neutron dosimetry.

journal_name

Radiat Prot Dosimetry

authors

Maki D,Kobayashi H,Sato F,Murata I,Kato Y,Tanaka T,Yamamoto T,Iida T

doi

10.1093/rpd/ncq552

subject

Has Abstract

pub_date

2011-03-01 00:00:00

pages

226-30

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

ncq552

journal_volume

144

pub_type

杂志文章
  • AUTOMATIC BRAIN DOSE ESTIMATION IN COMPUTED TOMOGRAPHY USING PATIENT DICOM IMAGES.

    abstract::This study aims to develop an Automatic Brain Dose Estimation (ABDE) methodology for head computed tomography examinations. The ABDE is to be applied first to an anthropomorphic Alderson phantom to obtain a Correction factor (Cf) between the ABDE and the direct absorbed brain dose using dosemeters positioned within th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa006

    authors: Gharbi S,Labidi S,Mars M

    更新日期:2020-07-02 00:00:00

  • DNA fragments induction in human fibroblasts by radiations of different qualities.

    abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl389

    authors: Esposito G,Belli M,Campa A,Cherubini R,Cuttone G,Dini V,Furusawa Y,Gerardi S,Simone G,Sorrentino E,Tabocchini MA

    更新日期:2006-01-01 00:00:00

  • W values of protons in liquid water.

    abstract::The W values of protons in liquid water were calculated for energies from 0.1 keV to 10 MeV using the continuous slowing down approximation as well as three models for the calculation of the differential ionisation cross-sections of water for protons published in recent years. The W values determined by means of the t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm019

    authors: Baek WY,Grosswendt B

    更新日期:2007-01-01 00:00:00

  • Secondary neutron doses in proton therapy treatments of ocular melanoma and craniopharyngioma.

    abstract::Monte Carlo simulations were used to assess secondary neutron doses received by patients treated with proton therapy for ocular melanoma and craniopharyngioma. MCNPX calculations of out-of-field doses were done for ∼20 different organs considering realistic treatment plans and using computational phantoms representati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct283

    authors: Farah J,Sayah R,Martinetti F,Donadille L,Lacoste V,Hérault J,Delacroix S,Nauraye C,Vabre I,Lee C,Bolch WE,Clairand I

    更新日期:2014-10-01 00:00:00

  • The measurements of thoron, radon and their decay products thanks to Pinocchio, Tengu and Trolls.

    abstract::In the present paper, the long noses of Pinocchio, Tengu and Trolls are used to measure, respectively, radon, thoron, and their decay products both by track-etch detectors and by Geiger-Müller (G-M) counters. Just recently, four new passive samplers (termed quatrefoil) have been developed which greatly simplify the de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq248

    authors: Tommasino L,Tokonami S,Tommasino PM

    更新日期:2010-10-01 00:00:00

  • Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures.

    abstract::A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of ph...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch468

    authors: Ohuchi H,Satoh T,Eguchi Y,Mori K

    更新日期:2005-01-01 00:00:00

  • Neutron and photon fields in the BNCT room with closed beam shutters.

    abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci112

    authors: Marek M,Viererbl L

    更新日期:2005-01-01 00:00:00

  • Dose estimation using quartz OSL in the non-linear region of the growth curve.

    abstract::The reliability of equivalent-dose determinations on quartz made with the single-aliquot regenerative-dose (SAR) protocol is examined using a suite of sedimentary samples for which the equivalent dose is expected to be >200 Gy. Experiments on one sample were used to evaluate the precision obtained using the standard m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006004

    authors: Murray AS,Wintle AG,Wallinga J

    更新日期:2002-01-01 00:00:00

  • OCCUPATIONAL EXPOSURE CHARACTERISTICS AND FACTORS ASSOCIATED WITH RADIATION DOSES AMONG KOREAN RADIATION WORKERS.

    abstract::This study identified occupational factors associated with radiation exposure in Korea. Survey data of 16 037 workers from 2016 to 2017, including lifestyle factors and occupational characteristics, were combined with the National Dose Registry. Higher average annual doses were observed in groups exhibiting health ris...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa019

    authors: Kim J,Seo S,Lee DN,Park S,Im KJ,Park S,Jin YW

    更新日期:2020-07-07 00:00:00

  • THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): AN INTRODUCTION TO THE DOCUMENTATION.

    abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx020

    authors: Napier BA

    更新日期:2017-11-01 00:00:00

  • A Monte-Carlo code for the detailed simulation of electron and light-ion tracks in condensed matter.

    abstract::In an effort to understand the basic mechanism of the action of charged particles in solid radiation dosimeters, we extend our Monte-Carlo code (MC4) to condensed media (liquids/solids) and present new track-structure calculations for electrons and protons. Modeling the energy dissipation process is based on a model d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci671

    authors: Emfietzoglou D,Papamichael G,Karava K,Androulidakis I,Pathak A,Phillips GW,Moscovitch M,Kostarelos K

    更新日期:2006-01-01 00:00:00

  • Use of various microdosimetric models for the prediction of radon induced damage in human lungs.

    abstract::Exposure to radon and radon decay products in some residential areas and at workplaces constitutes one of the greatest risks from natural sources of ionising radiation. Recently, increasing attention has been paid to the precise estimations of this health risk by numerous models. The compartmental model published in I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006173

    authors: Böhm R,Nikodémová D,Holý K

    更新日期:2003-01-01 00:00:00

  • EDDIX--a database of ionisation double differential cross sections.

    abstract::The use of Monte Carlo track structure is a choice method in biophysical modelling and calculations. To precisely model 3D and 4D tracks, the cross section for the ionisation by an incoming ion, double differential in the outgoing electron energy and angle, is required. However, the double differential cross section c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq397

    authors: MacGibbon JH,Emerson S,Liamsuwan T,Nikjoo H

    更新日期:2011-02-01 00:00:00

  • COMPARISON METHODOLOGIES FOR CALIBRATION OF Hp(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDS.

    abstract::The calibration of electronic personal dosemeters at the Portuguese ionizing radiation metrology laboratory uses the standard IEC 61526 for calibration methodology. This standard describes the irradiation geometry for testing and indicates that the standard ISO 4037-1, 2, 3 and 4 should be used. The ISO 4037 establish...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw126

    authors: Cardoso J,Santos L,Carvalhal G,Oliveira C

    更新日期:2016-09-01 00:00:00

  • SCOPING ANALYSIS OF MATERIAL ACTIVATION AT A BORON NEUTRON CAPTURE THERAPY FACILITY BASED ON THE Be(p,xn) REACTION WITH 30 MeV PROTONS.

    abstract::Material activation assessment of a proposed accelerator-based boron neutron capture therapy facility was performed using the FLUKA Monte Carlo code to quantify the magnitude of the problem in terms of the isotope inventories, induced activities, and residual dose rates. Two simplified operation scenarios were conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx289

    authors: Lai BL,Sheu RJ

    更新日期:2018-08-01 00:00:00

  • USE OF CLINICAL EXPOSURE INDEX AND DEVIATION INDEX BASED ON NATIONAL DIAGNOSTIC REFERENCE LEVEL AS DOSE-OPTIMIZATION TOOLS FOR GENERAL RADIOGRAPHY IN KOREA.

    abstract::The International Electrotechnical Commission introduced the concepts of exposure index (EI), target exposure index (EIT) and deviation index (DI) to manage and optimize patient dose in real time. In this study, we have proposed an appropriate method for setting the EIT based on the Korean national diagnostic referenc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa185

    authors: Park H,Yoon Y,Kim J,Kim J,Jeong H,Tanaka N,Morishita J

    更新日期:2020-11-17 00:00:00

  • Development of a radon trap device using a corona discharge.

    abstract::Radon is one of the noble gases, which are chemically inert and do not make any reactants under normal conditions. In this experiment we demonstrated an enigmatic reaction between radon and fluorine when a corona discharge is used as a promoter. Distinctive changes in radon concentrations were caused by the discharge ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci311

    authors: Yamada Y,Koizumi A,Ishikawa K,Hishinuma Y,Tatenuma K

    更新日期:2005-01-01 00:00:00

  • IMPROVEMENT OF GAMMA-RAY SUBTRACTION PROCEDURE FOR A CURRENT-MODE NEUTRON DETECTOR WITH A PAIR OF 6Li- AND 7Li-GLASS SCINTILLATORS.

    abstract::A current-mode neutron detector with a pair of 6Li- and 7Li-glass scintillators has been developed to measure high-flux neutrons in a boron neutron capture therapy field. Neutrons are basically measured by subtracting gamma-ray component using current outputs from the 7Li-glass scintillator. In the present study, the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz266

    authors: Matsumoto T,Masuda A,Harano H,Hori JI,Sano T

    更新日期:2020-06-12 00:00:00

  • Head calibration phantoms for actinides: measurements and simulations.

    abstract::The paper deals with the physical skull phantoms Bundesinstitut fuer Strahlenschutz and BPAM-001, which are used in order to calibrate in vivo detection systems for estimation of (241)Am activity in the skeleton. Their voxel models were made and used in the Monte Carlo simulations. The results of the simulation were c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq491

    authors: Vrba T

    更新日期:2011-03-01 00:00:00

  • Investigation of radiation-induced multilayered signalling response of the inflammatory pathway.

    abstract::Ionising radiation exposure of cells might induce the perturbation of cell functions and, in particular, the activation or inhibition of several important pathways. This perturbation can cause the deregulation of both intra- and extra-cellular signalling cascades (such as the inflammatory pathway) and alter not only t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv132

    authors: Babini G,Ugolini M,Morini J,Baiocco G,Mariotti L,de Fatis PT,Liotta M,Ottolenghi A

    更新日期:2015-09-01 00:00:00

  • Improved chelation therapy of intramuscularly deposited thorium by CaDTPA in the rat.

    abstract::Comparative studies on the translocation and retention of intramuscularly (i.m.) injected thorium nitrate (234Th 46 ng + 232Th 5 microg per rat) in solutions of citrate, CaDTPA or citrate + CaDTPA in rats have been conducted. Results showed that only thorium in mixed-ligand solution was entirely translocated from the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006294

    authors: Rencová J,Vlková A,Veselá G

    更新日期:2003-01-01 00:00:00

  • Dosimetric monitoring in Ukraine--present status and path to the future.

    abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl128

    authors: Chumak V,Boguslavskaya A

    更新日期:2007-01-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • Internal dosimetry verification and validation database.

    abstract::Simulated-data internal dosimetry cases for use in intercomparison exercises or as a software verification and validation tool have been published on the internet (www.lanl.gov/bayesian/software Bayesian software package II). A user may validate their internal dosimetry code or method using this simulated bioassay dat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm470

    authors: Miller G,Bertelli L,Little T,Guilmette RA

    更新日期:2007-01-01 00:00:00

  • Comparison of a CCD and a flat-panel digital system in an Interventional Cardiology Laboratory.

    abstract::We evaluated the performances of angiographic units equipped with a flat-panel (FP) detector and image intensifier (II) charge-coupled device (CCD) in the Interventional Cardiology (IC) Department. Entrance dose rate and dose per image, along with the dose at the II level were measured using 2 mm copper sheets to simu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci746

    authors: Tsapaki V,Kottou S,Kollaros N,Kyriakidis Z,Neofotistou V

    更新日期:2005-01-01 00:00:00

  • Modelling urinary excretion of molybdenum after oral and intravenous administration of stable tracers.

    abstract::An extensive study using stable isotopes of molybdenum as tracers was undertaken to investigate intestinal uptake, systemic kinetics and urinary excretion of molybdenum in healthy human volunteers. In total 63 experiments with 17 volunteers were performed administering the tracers in different chemical forms and measu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm263

    authors: Giussani A,Cantone MC,Höllriegl V,Oeh U,Tavola F,Veronese I

    更新日期:2007-01-01 00:00:00

  • The IUR Forum: Worldwide Harmonisation of Networks to Support Integration of Scientific Knowledge and Consensus Development in Radioecology.

    abstract::During the past decades, many specialised networks have formed to meet specific radioecological objectives, whether regional or sectorial (purpose-oriented). Regional networks deal with an array of radioecological issues related to their territories. Examples include the South Pacific network of radioecologists, and t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw290

    authors: Bréchignac F,Alexakhin R,Bollhöfer A,Frogg KE,Hardeman F,Higley K,Hinton TG,Kapustka LA,Kuhne W,Leonard K,Masson O,Nanba K,Smith G,Smith K,Strand P,Vandenhove H,Yankovich T,Yoshida S

    更新日期:2017-04-01 00:00:00

  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA.

    abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv430

    authors: Örtenberg A,Magnusson M,Sandborg M,Alm Carlsson G,Malusek A

    更新日期:2016-06-01 00:00:00

  • Assessment of doses and risk due to natural radionuclides in edible biota of Domiasiat, Meghalaya.

    abstract::A radiation dose assessment exercise was carried out for the edible biota Solanum nigrum, Carica papaya, Raphnus sativum and Phaseolus domesticus due to naturally available radionuclides (40)K, (238)U and (232)Th in the Domiasiat area in Meghalaya, India. The concentration of radionuclides in biota and corresponding s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr435

    authors: Kumar N,Chaturvedi SS,Jha SK

    更新日期:2012-07-01 00:00:00

  • An internal radiation dosimetry computer program, IDAC 2.0, for estimation of patient doses from radiopharmaceuticals.

    abstract::The internal dosimetry computer program internal dose assessment by computer (IDAC) for calculations of absorbed doses to organs and tissues as well as effective doses to patients from examinations with radiopharmaceuticals has been developed. The new version, IDAC2.0, incorporates the International Commission on Radi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct337

    authors: Andersson M,Johansson L,Minarik D,Mattsson S,Leide-Svegborn S

    更新日期:2014-12-01 00:00:00