Dose estimation using quartz OSL in the non-linear region of the growth curve.

Abstract:

:The reliability of equivalent-dose determinations on quartz made with the single-aliquot regenerative-dose (SAR) protocol is examined using a suite of sedimentary samples for which the equivalent dose is expected to be >200 Gy. Experiments on one sample were used to evaluate the precision obtained using the standard measurement procedure with (a) a range of pre-heat temperatures, and (b) a single pre-heat temperature. The precision is compared with that achieved using SAR for a repeated dose point after an initial pre-heat, and for a known dose given before the initial pre-heat. It is concluded that, at least for this sample, the scatter in OSL measurements dominates the spread in the estimates of De.

journal_name

Radiat Prot Dosimetry

authors

Murray AS,Wintle AG,Wallinga J

doi

10.1093/oxfordjournals.rpd.a006004

keywords:

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

371-4

issue

1-4

eissn

0144-8420

issn

1742-3406

journal_volume

101

pub_type

杂志文章
  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00

  • Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

    abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci667

    authors: Preciado-Flores S,Schreck M,Meléndrez R,Chernov V,Bernal R,Cruz-Vázquez C,Cruz-Zaragoza E,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • Determination of human absorbed dose of 201Tl(III)-DTPA-HIgG based on biodistribution data in rats.

    abstract::To estimate the absorbed dose in normal organs and inflamed tissue following i.v. administration of [201Tl](III)-DTPA-HIgG by using biodistribution data in inflamation bearing rats was attempted. The percentages of injected dose per gram of each organ were calculated. The medical internal radiation dose formulation was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq172

    authors: Khorrami Moghaddam A,Reza Jalilian A,Hayati V,Shanehsazzadeh S

    更新日期:2010-10-01 00:00:00

  • Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle.

    abstract::Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl545

    authors: Krol M,Lankoff A,Buraczewska I,Derezinska E,Wojcik A

    更新日期:2007-01-01 00:00:00

  • A family of statistical distributions for modelling occupational radiation doses in low dose occupations.

    abstract::New statistical distributions have been defined to describe occupational exposures to ionising radiation. These distributions are particularly useful in modelling occupations where most doses are low. The maximum likelihood method was used for parameter estimation and has been adapted to allow doses that are recorded ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl045

    authors: Sont WN

    更新日期:2006-01-01 00:00:00

  • French population exposure to radon, terrestrial gamma and cosmic rays.

    abstract::In France, natural sources account for most of the population exposure to ionising radiation. This exposure varies widely with area. Radon and gamma-ray exposure data come from national measurement campaigns; cosmic doses were calculated from city altitude. These data were corrected for season of measurement, housing ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch463

    authors: Billon S,Morin A,Caër S,Baysson H,Gambard JP,Backe JC,Rannou A,Tirmarche M,Laurier D

    更新日期:2005-01-01 00:00:00

  • BASELINE STUDIES ON RADIONUCLIDE CONCENTRATION IN FOOD MATERIALS AND ESTIMATION OF THE COMMITTED RADIATION DOSE AROUND THE PHOSPHATE INDUSTRIAL AREA OF SOUTH TUNISIA.

    abstract::The activity concentration of natural and anthropogenic radionuclides was determined in different vegetable samples, and foods derived from animal origin, from different locations in the four cities of Southern Tunisia, where large-scale phosphate industries are operating. The aim of the studies was to establish a bas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy208

    authors: Machraoui S,Mohan MP,Naregundi K,Labidi S

    更新日期:2019-08-01 00:00:00

  • Variations of soil radon concentrations along Chite fault in Aizawl district, Mizoram, India.

    abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu221

    authors: Singh S,Jaishi H,Tiwari RP,Tiwari RC

    更新日期:2014-11-01 00:00:00

  • Albedo Neutron Dosimetry in a Deep Geological Disposal Repository for High-Level Nuclear Waste.

    abstract::Albedo neutron dosemeter is the German official personal neutron dosemeter in mixed radiation fields where neutrons contribute to personal dose. In deep geological repositories for high-level nuclear waste, where neutrons can dominate the radiation field, it is of interest to investigate the performance of albedo neut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw147

    authors: Pang B,Becker F

    更新日期:2017-04-28 00:00:00

  • A survey of patient dose and clinical factors in a full-field digital mammography system.

    abstract::In this work, we analyse the dose to 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography (FFDM) system over a 2-y period. The information relevant to this study has been extracted from the image Digital Imaging and Communications in Medicine (DICOM) headers. Entr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch514

    authors: Morán P,Chevalier M,Ten JI,Fernández Soto JM,Vañó E

    更新日期:2005-01-01 00:00:00

  • Radiation exposure and disease questionnaires of early entrants after the Hiroshima bombing.

    abstract::It is popularly known that people who entered into the ground-zero area shortly after the atomic bombings in Hiroshima and Nagasaki suffered from various syndromes similar to acute radiation effects. External exposures from neutron-induced radionuclides in soil have recently been reassessed based on DS02 calculations ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr370

    authors: Imanaka T,Endo S,Kawano N,Tanaka K

    更新日期:2012-03-01 00:00:00

  • The TRADE experiment: shielding calculations for the building hosting the subcritical system.

    abstract::The TRADE project (TRiga Accelerator Driven Experiment), to be performed at the existing TRIGA reactor at ENEA Casaccia, has been proposed as a validation of the accelerator-driven system (ADS) concept. TRADE will be the first experiment in which the three main components of an ADS--the accelerator, spallation target ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci219

    authors: Burn KW,Carta M,Casalini L,Kadi Y,Monti S,Nava E,Palomba M,Petrovich C,Picardi L,Rubbia C,Troiani F

    更新日期:2005-01-01 00:00:00

  • Comparison of two JAERI phantoms and the problems discovered.

    abstract::During the course of an intercomparison exercise it was possible to compare two JAERI phantoms with each other by using a multi-energy photon emitting lung set (241Am/152Eu). One belonged to the IAEA (Vienna), the other belonged to the Human Monitoring Laboratory (Ottawa). The intercomparison of the phantoms showed th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006511

    authors: Kramer GH,Hauck BM

    更新日期:2001-01-01 00:00:00

  • Discussion on optimisation below dose limit for public using background-cancer-risk-based approach.

    abstract::To improve a radiological protection system, the lower bound of optimisation was discussed using a newly proposed background-cancer-risk-based approach. This approach provides a new finding that the standard deviation of the background cancer risk in Japan is 7.4 × 10(-5) y(-1). If this risk level corresponding to 1σ ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr150

    authors: Hattori T

    更新日期:2011-07-01 00:00:00

  • Radon measurements in the caves of Zonguldak (Turkey).

    abstract::There are approximately 20 caves of limestone origin in Zonguldak (Turkey). In this study, the results of atmospheric radon measurements performed for two caves are presented. These caves, Gökgöl and Cehennemağzi, are open to tourism. Gökgöl Cave is the longer, at nearly 3,200 m in length. Cehenennemağzi is a pit-type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci326

    authors: Aytekin H,Baldik R,Celebi N,Ataksor B,Tasdelen M,Kopuz G

    更新日期:2006-01-01 00:00:00

  • Spot measurements of intermediate frequency electric fields in the vicinity of compact fluorescent lamps.

    abstract::Starting in 2009, certain types of incandescent light bulbs will be withdrawn from the market in the European Union and elsewhere. However, compact fluorescent lamps that are among the candidates to replace them produce intermediate frequency electric fields (EFs) much higher than any other device or appliance previou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq276

    authors: Bakos J,Nagy N,Juhász P,Thuróczy G

    更新日期:2010-12-01 00:00:00

  • EVALUATION OF SECONDARY DOSE AND CANCER RISK FOR OUT-OF-FIELD ORGAN IN ESOPHAGEAL CANCER IMRT IN A CHINESE HOSPITAL USING ATOM PHANTOM MEASUREMENTS.

    abstract::There have been few studies on the secondary cancer after radiation treatment in Chinese hospitals. This study has measured out-of-field absorbed organ doses from intensity-modulated radiation therapy (IMRT) radiotherapy for esophageal cancer in a Chinese hospital and evaluated the risks of secondary cancer. The dose ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx057

    authors: Qi Y,He L,Wang Z,Liu Y,Liu H,Huo W,Xu XG,Chen Z

    更新日期:2017-12-01 00:00:00

  • On a model-based approach to radiation protection.

    abstract::There is a preoccupation with linearity and absorbed dose as the basic quantifiers of radiation hazard. An alternative is the fluence approach, whereby radiation hazard may be evaluated, at least in principle, via an appropriate action cross section. In order to compare these approaches, it may be useful to discuss th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006828

    authors: Waligórski MP

    更新日期:2002-01-01 00:00:00

  • Measurement of natural radioactivity in building materials used in Urumqi, China.

    abstract::Building materials contain natural radionuclides (226)Ra, (232)Th and (40)K, which cause direct radiation exposure of the public. The concentrations of (226)Ra, (232)Th and (40)K in commonly used building materials of Urumqi, China have been analysed using gamma-ray spectrometry. The concentrations of (226)Ra, (40)K a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct002

    authors: Ding X,Lu X,Zhao C,Yang G,Li N

    更新日期:2013-07-01 00:00:00

  • Patient dose in neonatal units.

    abstract::Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn237

    authors: Smans K,Struelens L,Smet M,Bosmans H,Vanhavere F

    更新日期:2008-01-01 00:00:00

  • Determination of radon concentration levels in well water in Konya, Turkey.

    abstract::Radon ((222)Rn) measurements were undertaken in 16 samples of well water representing different depths and different types of aquifers found at the city centre of Konya, Central Turkey. The radon activity concentrations of the well water samples collected in the spring and summer seasons of 2012 were measured by using...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct099

    authors: Erdogan M,Eren N,Demirel S,Zedef V

    更新日期:2013-10-01 00:00:00

  • Radioactive pollution from Fukushima Daiichi nuclear power plant in the terrestrial environment.

    abstract::Major contaminants from venting and hydrogen explosions at the Fukushima Daiichi nuclear reactors between 12 and 15 March 2011 were transported northwestward and deposited on soil and plants via precipitation. Surface soils and plant leaves were sampled at 64 sites in the Fukushima Prefecture. The highest concentratio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs222

    authors: Tazoe H,Hosoda M,Sorimachi A,Nakata A,Yoshida MA,Tokonami S,Yamada M

    更新日期:2012-11-01 00:00:00

  • INFLUENCE OF STATIC ELECTRICITY ON RADON MEASUREMENT USING PASSIVE DETECTORS.

    abstract::In order to investigate the influence of the static electricity on the measurement using passive radon detector, detectors were charged at the surface of chamber and its CR-39 elements respectively on purpose before the exposure in this study. The results of in-chamber experiments revealed that the static electricity ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz067

    authors: Chen B,Zhao C,Fan D,Zhuo W

    更新日期:2019-10-01 00:00:00

  • MEASUREMENTS OF RADIATION EXPOSURE OF RADIOGRAPHY STUDENTS DURING THEIR CLINICAL TRAINING USING THERMOLUMINESCENT DOSIMETRY.

    abstract::Radiation dose monitoring for radiography students during clinical training is necessary to demonstrate the extent of radiation protection issues present, as well as to instill in them an awareness of safe practices that they will carry with them throughout their careers. The study assess the radiation dose incurred b...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx261

    authors: Abuzaid MM,Elshami W,Steelman C

    更新日期:2018-05-01 00:00:00

  • High-Dose TL Dosimetry of Reactor Neutrons.

    abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx244

    authors: Obryk B,Malik K,Bilski P,Igielski A,Dankowski J,Kurowski A,Prokopowicz R,Pytel K

    更新日期:2018-08-01 00:00:00

  • Thermoluminescent properties of Ni and Co doped synthetic, high pressure, high temperature diamonds: application to ionising radiation dosimetry.

    abstract::An investigation of the thermoluminescence (TL) properties of high pressure, high temperature (HPHT) synthetic diamond crystals grown under diluted nickel or cobalt as solvent catalysts is reported. After a study of TL properties of 6 different samples, it is shown that a crystal grown with Ni+2%Ti and annealed at 210...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005880

    authors: Benabdesselam M,Iacconi P,Gheeraert E,Kanda H,Lapraz D,Briand D

    更新日期:2002-01-01 00:00:00

  • ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE.

    abstract:OBJECTIVE:The aim of this study was to propose first established diagnostic reference levels (DRLs) in computed tomography (CT) for adults, based on volume-averaged CTDI and dose length product (DLP) metrics in Yazd Province. MATERIALS AND METHODS:Six multislice CT scanners located at diverse areas of Yazd Province an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz279

    authors: Zamani H,Masjedi H,Omidi R,Hosein Zare M

    更新日期:2020-06-13 00:00:00

  • Nodule detection in digital chest radiography: effect of anatomical noise.

    abstract::The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (reffered to as anatomical noise) can be removed using a method developed within th...

    journal_title:Radiation protection dosimetry

    pub_type: 临床试验,杂志文章

    doi:10.1093/rpd/nch526

    authors: Båth M,Håkansson M,Börjesson S,Hoeschen C,Tischenko O,Kheddache S,Vikgren J,Månsson LG

    更新日期:2005-01-01 00:00:00

  • Digital dual-parameter data acquisition for SP2 hydrogen-filled proportional counters.

    abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct262

    authors: Hawkes NP,Roberts NJ

    更新日期:2014-10-01 00:00:00

  • Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032854

    authors: Vana N,Schoner W,Noll M,Fugger M,Akatov Y,Shurshakov V

    更新日期:1999-01-01 00:00:00