Patient dose in neonatal units.

Abstract:

:Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Hence, knowledge of the patient dose is necessary to justify the exposures. A study to assess the patient doses was started at the neonatal intensive care unit (NICU) of the University Hospital in Leuven. Between September 2004 and September 2005, prematurely born babies underwent on average 10 X-ray examinations in the NICU. In this sample, the maximum was 78 X-ray examinations. For chest radiographs, the median entrance skin dose was 34 microGy and the median dose area product was 7.1 mGy.cm(2). By means of conversion coefficients, the measured values were converted to organ doses. Organ doses were calculated for three different weight classes: extremely low birth weight infants (<1000 g), low birth weight infants (1000-2500 g) and normal birth weight infants (>2500 g). The doses to the lungs for a single chest radiograph for infants with extremely low birth weights, low birth weights and normal birth weights were 24, 25 and 32 microGy, respectively.

journal_name

Radiat Prot Dosimetry

authors

Smans K,Struelens L,Smet M,Bosmans H,Vanhavere F

doi

10.1093/rpd/ncn237

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

143-7

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncn237

journal_volume

131

pub_type

杂志文章
  • On the equivalence of propane-based tissue-equivalent gas and liquid water with respect to the ionisation-yield formation by electrons and alpha-particles.

    abstract::One encouraging way, at present, to put the investigation of ionisation-yield formation in sub-cellular structures or, at least, in nanometric volumes of liquid water on an experimental basis is the use of highly sophisticated counters filled with gases at low operating pressure to simulate target volumes a few nm in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006818

    authors: Grosswendt B

    更新日期:2002-01-01 00:00:00

  • Foods found in the wild around nuclear sites: an evaluation of radiological impact.

    abstract::Habit surveys were carried out around four licensed nuclear sites to identify people who collect foodstuffs from the wild (so-called 'free foods'). In total, around 800 collectors were readily identified, most of whom collected more than one free food. The data indicated that estimates of higher than average doses cou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006415

    authors: Green N,Wilkins BT,Hammond DJ,Davidson MF,Richmond S,Brooker S

    更新日期:2001-01-01 00:00:00

  • Indoor radon measurements in Turkey dwellings.

    abstract::In this work, indoor radon radioactivity concentration levels have been measured in dwellings of Turkey within the frame of the National Radon Monitoring Programme. The (222)Rn concentrations were measured with time-integrating passive nuclear etched track detectors in 7293 dwellings in 153 residential units of 81 pro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu329

    authors: Celebi N,Ataksor B,Taskın H,Bingoldag NA

    更新日期:2015-12-01 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00

  • Lithium fluoride: from LiF:Mg,Ti to LiF:Mg,Cu,P.

    abstract::Differences and similarities between LiF-based LiF:Mg,Ti and LiF:Mg,Cu,P are discussed, with respect to their dosimetric properties--sensitivity, non-linearity of dose response and heavy charged particle efficiency, as related to the concentration and the individual role of the Mg, Ti, Cu and P dopants. To study furth...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005847

    authors: Bilski P

    更新日期:2002-01-01 00:00:00

  • CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II.

    abstract::Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx236

    authors: Harrison J,Moreno B,Van Hoey O,Mihailescu LC,Vanhavere F,Million M,Fomenko V,Akselrod M

    更新日期:2018-08-01 00:00:00

  • Occupational exposure to electromagnetic fields in physiotherapy departments.

    abstract::To assess occupational exposure to electromagnetic fields, 11 microwave (MW), 4 short-wave diathermy and 15 magneto therapy devices were analysed in eight physiotherapy departments. Measurements taken at consoles and environmental mapping showed values above European Directive 2004/40/EC and ACGIH exposure limits at a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm309

    authors: Maccà I,Scapellato ML,Carrieri M,Pasqua di Bisceglie A,Saia B,Bartolucci GB

    更新日期:2008-01-01 00:00:00

  • Further progress in the characterisation of complex radiation fields.

    abstract::One of the topics which forms part of CONRAD project addresses the problems related to the dosimetry of complex-mixed radiation fields at workplaces. This topic was included in work package (WP) 6. WP 6 was established to co-ordinate research activities in two areas:the development of new techniques and the improvemen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn220

    authors: Spurny F,Silari M

    更新日期:2008-01-01 00:00:00

  • Radiological emergency: Malaysian preparedness and response.

    abstract::Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr102

    authors: Yusof MA,Ali HM

    更新日期:2011-07-01 00:00:00

  • Response of silicon diode dosemeters to scattered radiation from megavoltage photon beams.

    abstract::Dose response effects of diodes due to the high atomic number of silicon relative to water are investigated. While quality chances in the primary component of a megavoltage beam with depth are minimal. Compton scattered photons are shown to have a substantial effect on the quality leading to their enhanced absorption ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006014

    authors: Yin Z,Hugtenburg RP,Beddoe AH

    更新日期:2002-01-01 00:00:00

  • Issues, considerations and recommendations on emergency preparedness for vulnerable population groups.

    abstract::The Workshop on Emergency Preparedness for Vulnerable Population Groups was held on 2 and 3 March 2009 in Ottawa, ON, Canada. The purpose of the workshop was to enhance communications within the emergency community response network and to identify the needs and gaps of emergency preparedness against chemical, biologic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp083

    authors: Chen J,Wilkinson D,Richardson RB,Waruszynski B

    更新日期:2009-06-01 00:00:00

  • The impact of automatic wedge filter on photoneutron and photon spectra of an 18-MV photon beam.

    abstract::The effect of an automatic wedge filter on photon and photoneutron spectra of a medical linac was evaluated using the Monte Carlo method. The head of an Elekta SL75/25 was simulated using the MCNPX Monte Carlo code. The photon and photoneutron spectra for open and wedged beams were calculated at the isocentre with a s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp204

    authors: Ghavami SM,Mesbahi A,Mohammadi E

    更新日期:2010-02-01 00:00:00

  • The in vivo assessment of thorium body burden by gamma ray sepctrometry.

    abstract::Thorium is used in many different industrial technologies and is widely found in nature. Internal contamination with thorium is considered as highly hazardous because of its radiological and chemical toxicities, which depend on the chemical form in which thorium appears. The assessment of the thorium body burden is th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006656

    authors: Genicot JL,Bruggeman M

    更新日期:2001-01-01 00:00:00

  • Determination of natural radioactivity in drinking water in private dug wells in Akure, Southwestern Nigeria.

    abstract::Gamma spectrometry of well water was done to measure the activity concentrations of gamma-emitters 226Ra and 228Ra from 238U and 232Th series, respectively, and 40K in their waters. Measurements were done using high-purity (HPGe) co-axial detectors (Canberra, GC 2018-7500 ) coupled to Canberra Multichannel Analyser sy...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm429

    authors: Ajayi OS,Owolabi TP

    更新日期:2008-01-01 00:00:00

  • Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry.

    abstract::The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al(2)O(3):C,Mg) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm058

    authors: Sykora GJ,Akselrod MS,Salasky M,Marino SA

    更新日期:2007-01-01 00:00:00

  • Radioactivity and dose assessment of marble samples from Igbeti mines, Nigeria.

    abstract::The concentration and distribution of natural radionuclides in marble around Igbeti marble mines, Nigeria, were measured to evaluate the environmental radioactivity and health effects which the marble samples may posses. The concentration of radionuclides was determined using gamma-ray spectrometry with NaI (Tl) detec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn279

    authors: Ademola AK,Hammed OS,Adejumobi CA

    更新日期:2008-01-01 00:00:00

  • LEAD COMPOSITE VS. NONLEAD PROTECTIVE GARMENTS: WHICH ARE BETTER? A MULTIVENDOR COMPARISON.

    abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw373

    authors: Peters SMB,Zweers D,de Lange F,Mourik JEM

    更新日期:2017-08-01 00:00:00

  • Uncertainty evaluation of radon measurements with LR115 detector and spark counter.

    abstract::To evaluate the uncertainties for nuclear track detectors used in radon measurements, a full understanding is required of the physical phenomena involved and the behaviour of the instruments utilised in the measuring process. As it concerns the LR115 nuclear track detector, an overall evaluation of uncertainty was giv...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch361

    authors: Campi F,Caresana M,Ferrarini M,Garlati L,Palermo M,Rusconi R

    更新日期:2004-01-01 00:00:00

  • The analysis of thermoluminescent glow peaks of natural calcite after beta irradiation.

    abstract::In this study, the thermoluminescence properties of natural calcite samples were examined in detail. The glow curve of the sample irradiated with beta radiation shows two main peaks, P1 (at 115 °C) and P4 (at 254 °C). The additive dose, variable heating rate, computer glow curve deconvolution, peak shape and three poi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs020

    authors: Yildirim RG,Kafadar VE,Yazici AN,Gün E

    更新日期:2012-09-01 00:00:00

  • Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital.

    abstract::To assess the frequency of examination, image quality (IQ) and establishment of local diagnostic reference levels (LDRLs) in paediatric radiographic examinations. The X-ray device performance, film reject rate and IQ grading were assessed at Radiology Department of a referral and teaching children's hospital in Kenya....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs270

    authors: Wambani JS,Korir GK,Korir IK,Kilaha S

    更新日期:2013-05-01 00:00:00

  • A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.

    abstract::A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NR...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv478

    authors: Walbersloh J,Busch F

    更新日期:2016-09-01 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • Independent regulatory examination of radiation situation in the areas of spent nuclear fuel and radioactive wastes storage in the Russian far east.

    abstract::This paper describes the findings of the radiation situation analysis on-site near Sysoeva and Razbojnik Bays. The results of radiation monitoring performed by radiological laboratory of DalRAO and studies performed by the experts from the Burnasyan Federal Medical Biophysical Centre have been used in the course of an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr135

    authors: Shandala NK,Kiselev SM,Lucyanec AI,Titov AV,Seregin VA,Isaev DV,Akhromeev SV

    更新日期:2011-07-01 00:00:00

  • Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

    abstract::Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu219

    authors: Jiránek M

    更新日期:2014-11-01 00:00:00

  • Seasonal variation of indoor radon-222 levels in dwellings in Ramallah province and East Jerusalem suburbs, Palestine.

    abstract::This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated bu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr013

    authors: Leghrouz AA,Abu-Samreh MM,Shehadeh AK

    更新日期:2012-01-01 00:00:00

  • Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    abstract::To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw098

    authors: Hu P,Kong Y,Chen B,Liu Q,Zhuo W,Liu H

    更新日期:2017-04-20 00:00:00

  • Active neutron dosemeters based on microdosimetric principles: research studies.

    abstract::Over the past few years, the Institute for Radiation Protection and Nuclear Safety (IRSN) has been studying a personal electronic neutron dosemeter and an ambient electronic neutron dosemeter based on experimental microdosimetric principles using low pressure proportional counters. The results obtained in 2000 and in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006808

    authors: Ménard S,Chau Q,Lahaye T

    更新日期:2002-01-01 00:00:00

  • NASA Space Radiation Transport Code Development Consortium.

    abstract::Recently, NASA established a consortium involving the University of Tennessee (lead institution), the University of Houston, Roanoke College and various government and national laboratories, to accelerate the development of a standard set of radiation transport computer codes for NASA human exploration applications. T...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci092

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • 1800 MHz in vitro exposure device for experimental studies on the effects of mobile communication systems.

    abstract::A wire patch cell (WPC) operating at the uplink frequency band of GSM 1800 MHz has been designed for in vitro experiments with the aim of investigating the possible biological effects of electromagnetic radiation associated with cellular phones. The 1800 MHz WPC design is a direct descendant of the original 900 MHz WP...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch414

    authors: Ardoino L,Lopresto V,Mancini S,Pinto R,Lovisolo GA

    更新日期:2004-01-01 00:00:00

  • Assessment of radiation doses to Australian participants in British nuclear tests.

    abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp164

    authors: Crouch P,Robotham FR,Williams G,Wise K

    更新日期:2009-09-01 00:00:00