MEASUREMENTS OF RADIATION EXPOSURE OF RADIOGRAPHY STUDENTS DURING THEIR CLINICAL TRAINING USING THERMOLUMINESCENT DOSIMETRY.

Abstract:

:Radiation dose monitoring for radiography students during clinical training is necessary to demonstrate the extent of radiation protection issues present, as well as to instill in them an awareness of safe practices that they will carry with them throughout their careers. The study assess the radiation dose incurred by the undergraduate during clinical training. 312 students were monitored using (thermoluminescence dosimetry) between 2009 and 2015. The results establish that the radiation dose received by the students is well below the dose recommended by national and international authorities. Findings indicate that the dose did not reach the value of 1 mSv, which indicate that current radiation protection measures are acceptable and there was no risk of overexposure, as well as reinforces the importance of nuturing a culture of radiation protection and provides evidence to students that their future as professionals will be a safe one.

journal_name

Radiat Prot Dosimetry

authors

Abuzaid MM,Elshami W,Steelman C

doi

10.1093/rpd/ncx261

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

244-247

issue

3

eissn

0144-8420

issn

1742-3406

pii

4653519

journal_volume

179

pub_type

杂志文章
  • Review of international standards for dosemeters.

    abstract::International standards for radiation protection dosemeters are published by the International Electrotechnical Commission and the International Organization for Standardization. Several standards exist side by side, although they treat the same measuring task, and specify different requirements, so that dosemeters of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm331

    authors: Behrens R,Ambrosi P

    更新日期:2008-01-01 00:00:00

  • Shielding design of the ITER NBI duct for nuclear and bremsstrahlung radiation.

    abstract::Three-dimensional Monte Carlo shielding analyses are conducted on the ITER Neutral Beam Injection (NBI) duct for the nuclear and bremsstrahlung radiation. The detailed distribution is evaluated about the nuclear heating rate and surface heat load of the NBI duct wall by the neutron and photon transport calculation. Th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci195

    authors: Sato S,Iida H,Yamauchi M,Nishitani T

    更新日期:2005-01-01 00:00:00

  • Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    abstract::Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm455

    authors: Becková V,Malátová I

    更新日期:2008-01-01 00:00:00

  • The analysis of thermoluminescent glow peaks of natural calcite after beta irradiation.

    abstract::In this study, the thermoluminescence properties of natural calcite samples were examined in detail. The glow curve of the sample irradiated with beta radiation shows two main peaks, P1 (at 115 °C) and P4 (at 254 °C). The additive dose, variable heating rate, computer glow curve deconvolution, peak shape and three poi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs020

    authors: Yildirim RG,Kafadar VE,Yazici AN,Gün E

    更新日期:2012-09-01 00:00:00

  • Implementation of the new international standards in Swiss legislation on radon protection in dwellings.

    abstract::The current revision of the Swiss Radiological Protection Ordinance aims to bring Swiss legislation in line with new international standards. In future, the control of radon exposure in dwellings will be based on a reference level of 300 Bq m(-3). Since this value is exceeded in >10 % of the buildings so far investiga...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu307

    authors: Palacios Gruson M,Barazza F,Murith C,Ryf S

    更新日期:2015-04-01 00:00:00

  • The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography.

    abstract::The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv114

    authors: Dyakov I,Stoinova V,Groudeva V,Vassileva J

    更新日期:2015-07-01 00:00:00

  • Radon in thermal waters in south-east part of Serbia.

    abstract::There are several occurrences of thermal waters in the south-eastern part of Serbia, which are originating from igneous and metamorphic rocks. These waters are mainly used in balneology, but some of them are used for drinking purposes and in water supply to heat buildings, for greenhouses and to irrigate land. In this...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu094

    authors: Nikolov J,Todorović N,Bikit I,Pantić TP,Forkapić S,Mrđa D,Bikit K

    更新日期:2014-07-01 00:00:00

  • Breast cancer risk after radiation treatment at infancy: potential consequences of radiation-induced genomic instability.

    abstract::Swedish hemangioma patients were treated in infancy mainly by external application of radium-226 starting from 1920. This work analysed the radiation risk among 17,158 women with a total of 678 breast cancer incidence cases with models of carcinogenesis and empirical excess relative risk models. Models incorporating e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq473

    authors: Eidemüller M,Holmberg E,Jacob P,Lundell M,Karlsson P

    更新日期:2011-02-01 00:00:00

  • Insights into the sites of X ray and neutron induced chromosomal aberrations in human lymphocytes using COBRA-MFISH.

    abstract::A multi-colour fluorescence in situ hybridisation (MFISH) assay has been developed, for simultaneous visualisation of all human chromosomes in 24 different colours. This assay is based on the simultaneous use of combinatorial labelling and ratio labelling, the so called combined binary ratio labelling (COBRA). This te...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006758

    authors: Darroudi F,Bezrookove V,Fomina J,Mesker WE,Wiegant JC,Raap AK,Tanke HJ

    更新日期:2002-01-01 00:00:00

  • RADON SURVEY IN SCHOOL AND ESTIMATION OF EFFECTIVE DOSE USING CORRECTED RADON CONCENTRATION.

    abstract::Radon exposure in schools is different from that in dwellings because the residence pattern is very different each other. So, when effective dose is calculated in schools, different approach should be considered from in dwellings. The aim of this study was to estimate actual effective dose due to inhaled radon conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx216

    authors: Lee ER,Chang BU,Kim YJ

    更新日期:2018-04-01 00:00:00

  • DNA fragments induction in human fibroblasts by radiations of different qualities.

    abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl389

    authors: Esposito G,Belli M,Campa A,Cherubini R,Cuttone G,Dini V,Furusawa Y,Gerardi S,Simone G,Sorrentino E,Tabocchini MA

    更新日期:2006-01-01 00:00:00

  • DETERMINATION OF DIAGNOSTIC REFERENCE LEVEL IN ROUTINE EXAMINATIONS OF DIGITAL RADIOGRAPHY IN MAZANDARAN PROVINCE.

    abstract:INTRODUCTION:The main purpose of this study was to determine the diagnostic reference level (DRL) for routine digital radiography examinations in Mazandaran province. MATERIALS AND METHODS:Thirteen digital radiographic examinations at 18 high-patient-load radiography centres were investigated. The indirect dosimetry m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa074

    authors: Hoseini Motlagh Z,Shabestani Monfared A,Deevband MR,Abedi-Firouzjah R,Ghaemian N,Abdi R,Ebrahimnejad Gorji K

    更新日期:2020-08-03 00:00:00

  • 1st International comparison measurement on assessing the diffusion coefficient of radon.

    abstract::Radon diffusion coefficient is a material parameter which is usually used in the radon mitigation measures design. There are different approaches used for radon diffusion coefficient measurement and assessment. The International comparison measurement which was jointly organised by National Radiation Protection Instit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr079

    authors: Rovenska K,Jiránek M

    更新日期:2011-05-01 00:00:00

  • Non-radiation induced signals in TL dosimetry.

    abstract::One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some eff...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006064

    authors: German U,Weinstein M

    更新日期:2002-01-01 00:00:00

  • Harmonization of individual dosimetry quality control within metrology system of a small country.

    abstract::A programme of harmonization of individual dosimetry quality control organized in the framework of a distributed metrology system is presented as seen from the experiences gained in Slovenia. As a part of the programme intercomparison of dosimetry services was organized and basic characteristics of dosimetry systems c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm198

    authors: Stuhec M,Zorko B,Vekić B,Miljanić S,Ban R,Basić B

    更新日期:2007-01-01 00:00:00

  • A dose index as a tool to estimate paediatric patient doses in digital projection radiography.

    abstract::Radiation exposure during childhood is estimated to have a lifetime risk up to seven times greater than exposures at adult age. Therefore, paediatric patient dose monitoring is a major concern in radiology. The aim of this study is to evaluate the validity of a dose index, displayed at the digital imaging and communic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr313

    authors: Garcia Castañon P,España Lopez ML,Fernandez Bedoya V,Bermudez Luna R,Rodriguez Martin G

    更新日期:2012-05-01 00:00:00

  • A combination study of indoor radon and in situ gamma spectrometry measurements in Greek dwellings.

    abstract::The aim of the present study was to investigate of a possible correlation between indoor radon and indoor gamma dose rates deduced by in situ gamma spectrometry measurements by using a portable HPGe detector. Indoor radon and high resolution in situ gamma spectrometry measurements were performed in 60 apartments in Th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006154

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • ESTIMATION OF ORGAN DOSES AMONG DIAGNOSTIC MEDICAL RADIATION WORKERS IN SOUTH KOREA.

    abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx239

    authors: Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee W

    更新日期:2018-04-01 00:00:00

  • Determination of the dose to persons assisting when X-radiation is used in medicine, dentistry and veterinary medicine.

    abstract::During medical X-ray examinations of patients, humans as well as animals, voluntarily assisting persons are frequently needed in order to calm down the patient or animal. Typical exposure situations have been identified and measurements were performed in the fields of scattered X-rays. The personal dose equivalent H(p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq351

    authors: Hupe O,Ankerhold U

    更新日期:2011-03-01 00:00:00

  • Modelling urinary excretion of molybdenum after oral and intravenous administration of stable tracers.

    abstract::An extensive study using stable isotopes of molybdenum as tracers was undertaken to investigate intestinal uptake, systemic kinetics and urinary excretion of molybdenum in healthy human volunteers. In total 63 experiments with 17 volunteers were performed administering the tracers in different chemical forms and measu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm263

    authors: Giussani A,Cantone MC,Höllriegl V,Oeh U,Tavola F,Veronese I

    更新日期:2007-01-01 00:00:00

  • Assessment of occupational exposure to uranium by indirect methods needs information on natural background variations.

    abstract::Urine monitoring is the preferred method to determine exposure to soluble compounds of uranium in workplaces. The interpretation of uranium contents in workers bioassay samples requires knowledge on uranium excretion and its dependence on intake by diet. Exceptionally high concentrations of natural uranium in private ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm155

    authors: Muikku M,Heikkinen T,Puhakainen M,Rahola T,Salonen L

    更新日期:2007-01-01 00:00:00

  • Developments in the internal dosimetry of radiopharmaceuticals.

    abstract::Various radionuclides are used in nuclear medicine in different diagnostic and therapeutic procedures. Recently, interest has grown in therapeutic agents for some interesting applications in nuclear medicine. Internal dose models and methods in use for many years are well established, and can give radiation doses to s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006306

    authors: Stabin MG

    更新日期:2003-01-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • Occupational exposure to electromagnetic fields in physiotherapy departments.

    abstract::To assess occupational exposure to electromagnetic fields, 11 microwave (MW), 4 short-wave diathermy and 15 magneto therapy devices were analysed in eight physiotherapy departments. Measurements taken at consoles and environmental mapping showed values above European Directive 2004/40/EC and ACGIH exposure limits at a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm309

    authors: Maccà I,Scapellato ML,Carrieri M,Pasqua di Bisceglie A,Saia B,Bartolucci GB

    更新日期:2008-01-01 00:00:00

  • Fast neutron spectrometry and dosimetry using a spherical moderator with position-sensitive detectors.

    abstract::A neutron spectrometry and dosimetry measurement system has been developed based on a different design of the divided regions for a sphere, with three position-sensitive counters. The characteristics of the measurement system have been investigated in the reference radiation fields of Am-Be and (252)Cf sources. When r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl077

    authors: Li T,Yang L,Ma J,Fang D

    更新日期:2007-01-01 00:00:00

  • EPR properties of intact and deproteinated dentin.

    abstract::The effect of sample preparation on dentin electron paramagnetic resonance (EPR) spectra was investigated. The analysis was performed on dentin samples prepared by pure mechanical treatment or by an alkaline deproteination method. It was observed that (1) mechanical treatment induces both stable and transient signals,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci631

    authors: Fattibene P,Carosi A,De Coste V,Onori S

    更新日期:2006-01-01 00:00:00

  • Organisation and delivery of imaging services: the contributions of ethics and political economy.

    abstract::The objective of this discussion is to explore how theories from other disciplines can contribute to the debate on organisation and delivery of diagnostic and therapeutic exposures. The first part explores how theories of justice suggest that health services should be provided; the second part explores how stakeholder...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp043

    authors: Durand-Zaleski I

    更新日期:2009-07-01 00:00:00

  • Characterisation of workplaces with risks of internal exposures: air sampling.

    abstract::The measurement of air samples may be used to assess risks of internal exposures, either by the use of workplace static air samplers (SAS) or personal air samplers (PAS). These measurements need to incorporate information on the physical and chemical nature of the aerosol, and the relationship between the sampled and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm397

    authors: Roberts GA,Bull RK

    更新日期:2007-01-01 00:00:00

  • The effect of Mg, Cu and P impurities on dose response of LiF:Mg,Cu,P phosphors: simulation versus experiments.

    abstract::In this research, the effect of magnesium (Mg), copper (Cu) and phosphorus (P) impurities on dosimetry response of LiF:Mg,Cu,P phosphors is studied experimentally and by the simulation procedure. In the experimental procedure, LiF:Mg,Cu,P phosphors in the powder form were synthesised by chemical co-precipitation metho...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv002

    authors: Mohammadi K,Khayat O,Afarideh H

    更新日期:2016-01-01 00:00:00