Developments in the internal dosimetry of radiopharmaceuticals.

Abstract:

:Various radionuclides are used in nuclear medicine in different diagnostic and therapeutic procedures. Recently, interest has grown in therapeutic agents for some interesting applications in nuclear medicine. Internal dose models and methods in use for many years are well established, and can give radiation doses to stylised models representing reference individuals. Kinetic analyses need to be carefully planned, and dose conversion factors that are most similar to the subject in question should be chosen, which can then be tailored somewhat to be more patient-specific. Internal dose calculations, however, are currently not relevant in patient management in internal emitter therapy, as they are not sufficiently accurate or detailed to guide clinical decision-making, and as calculated doses have historically not been well correlated with observed effects on tissues. Great strides are being made at many centres regarding the use of patient image data to construct individualised voxel-based models for more detailed and patient-specific dose calculations, and new findings are encouraging regarding improvement of internal dose models to provide better correlations of dose and effect. These recent advances make it likely that the relevance will soon change to be more similar to that of external beam treatment planning.

journal_name

Radiat Prot Dosimetry

authors

Stabin MG

doi

10.1093/oxfordjournals.rpd.a006306

keywords:

subject

Has Abstract

pub_date

2003-01-01 00:00:00

pages

575-80

issue

1-4

eissn

0144-8420

issn

1742-3406

journal_volume

105

pub_type

杂志文章,评审
  • Plutonium in the Ozyorsk population.

    abstract::Results of the long-term autopsy studies on plutonium body burden in the population of Ozyorsk situated in the vicinity of the radiochemical plant of the Mayak Production Association (Russia) have been presented. The data were obtained from radiochemical analysis of the soft tissue and bone samples collected at the au...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm303

    authors: Suslova KG,Khokhryakov VF,Sokolova AB

    更新日期:2007-01-01 00:00:00

  • EPR DOSIMETRY STUDY FOR POPULATION RESIDING IN THE VICINITY OF FALLOUT TRACE FOR NUCLEAR TEST ON 7 AUGUST 1962.

    abstract::The method of electron paramagnetic resonance (EPR) dosimetry using extracted teeth has been applied to human tooth enamel to obtain individual absorbed doses of residents of settlements in the vicinity of the central axis of radioactive fallout trace from the contaminating surface nuclear test on 7 August 1962. Most ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw178

    authors: Zhumadilov KS,Ivannikov AI,Stepanenko VF,Toyoda S,Skvortsov VG,Hoshi M

    更新日期:2016-12-01 00:00:00

  • Reliability of the ICRP'S dose coefficients for members of the public: IV. basis of the human alimentary tract model and uncertainties in model predictions.

    abstract::The biokinetic and dosimetric model of the gastrointestinal (GI) tract applied in current documents of the International Commission on Radiological Protection (ICRP) was developed in the mid-1960s. The model was based on features of a reference adult male and was first used by the ICRP in Publication 30, Limits for In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl104

    authors: Leggett R,Harrison J,Phipps A

    更新日期:2007-01-01 00:00:00

  • EDDIX--a database of ionisation double differential cross sections.

    abstract::The use of Monte Carlo track structure is a choice method in biophysical modelling and calculations. To precisely model 3D and 4D tracks, the cross section for the ionisation by an incoming ion, double differential in the outgoing electron energy and angle, is required. However, the double differential cross section c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq397

    authors: MacGibbon JH,Emerson S,Liamsuwan T,Nikjoo H

    更新日期:2011-02-01 00:00:00

  • A comparative study of quality control in diagnostic radiology.

    abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn096

    authors: Kharita MH,Khedr MS,Wannus KM

    更新日期:2008-01-01 00:00:00

  • A very low-background gamma-ray counting facility in the Baradello underground laboratory.

    abstract::An underground station for the measurement of low-level radioactivity is in operation in Northern Italy in the town of Como under the Baradello hill. The rock cover is -300 m water equivalent. This paper reports about the preliminary measurements carried out to characterise the site of the Baradello hill and the insta...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci163

    authors: Pellicciari M,Fascilla A,Giuliani A,Pedretti M,Cesana A,Garlati L,Terrani M,Raselli GL

    更新日期:2005-01-01 00:00:00

  • IMPORTANCE OF ENGAGING IN DIALOGUE WITH THE POPULATION AFTER A NUCLEAR ACCIDENT.

    abstract::Human behaviour is primarily driven by perceptions and this is particularly important in the aftermath of a nuclear accident. One of the main lessons we can draw from the Chernobyl and Fukushima accidents is that once the acute phase of the accident is over, it is important to engage in dialogue with the affected popu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw320

    authors: Vanmarcke H

    更新日期:2017-04-01 00:00:00

  • Results of field trials using the NPL simulated reactor neutron field facility.

    abstract::The NPL simulated reactor neutron field facility provides neutron spectra similar to those found in the environs of UK gas-cooled reactors. Neutrons are generated by irradiating a thick lithium-alloy target with monoenergetic protons between 2.5 and 3.5 MeV (depending on the desired spectrum), and then moderated by a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm018

    authors: Taylor GC,Thomas DJ,Bennett A

    更新日期:2007-01-01 00:00:00

  • Czech results at criticality dosimetry intercomparison 2002.

    abstract::Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters use...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/nch276

    authors: Frantisek S,Jaroslav T

    更新日期:2004-01-01 00:00:00

  • A survey on uncertainty in bioassay measurements carried out within the OMINEX project.

    abstract::One of the topics covered by the OMINEX (Optimisation of Monitoring for Internal Exposure) project was to look at the bioassay measurements performed in the European laboratories. Questionnaires on bioassay measurements by alpha spectrometry or inductively coupled plasma-mass spectrometry (ICP-MS) were sent to Europea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006261

    authors: Hurtgen C,Cossonnet C

    更新日期:2003-01-01 00:00:00

  • Detection of primary and secondary cosmic ray particles aboard the ISS using SSNTD stacks.

    abstract::To study the radiation environment inside the International Space Station, solid state nuclear track detector stacks were used. Within the BRADOS experiments, Phase 1, seven stacks were exposed at different locations of the Russian segment 'Zvezda' for 248 days in 2001. It was supposed that the radiation field inside ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci673

    authors: Pálfalvi JK,Akatov Y,Szabó J,Sajó-Bohus L,Eördögh I

    更新日期:2006-01-01 00:00:00

  • DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04.

    abstract::A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge wi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv406

    authors: Haninger T,Henniger J

    更新日期:2016-09-01 00:00:00

  • DETERMINATION OF DIAGNOSTIC REFERENCE LEVEL IN ROUTINE EXAMINATIONS OF DIGITAL RADIOGRAPHY IN MAZANDARAN PROVINCE.

    abstract:INTRODUCTION:The main purpose of this study was to determine the diagnostic reference level (DRL) for routine digital radiography examinations in Mazandaran province. MATERIALS AND METHODS:Thirteen digital radiographic examinations at 18 high-patient-load radiography centres were investigated. The indirect dosimetry m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa074

    authors: Hoseini Motlagh Z,Shabestani Monfared A,Deevband MR,Abedi-Firouzjah R,Ghaemian N,Abdi R,Ebrahimnejad Gorji K

    更新日期:2020-08-03 00:00:00

  • 1st International comparison measurement on assessing the diffusion coefficient of radon.

    abstract::Radon diffusion coefficient is a material parameter which is usually used in the radon mitigation measures design. There are different approaches used for radon diffusion coefficient measurement and assessment. The International comparison measurement which was jointly organised by National Radiation Protection Instit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr079

    authors: Rovenska K,Jiránek M

    更新日期:2011-05-01 00:00:00

  • PRE-ANTHROPIC AND PRESENT OUTDOOR GAMMA EQUIVALENT DOSE RATE OF THE HISTORIC CENTER OF ROME (ITALY).

    abstract::The outdoor gamma background of the historic center of Rome was studied by in situ measurements and average values of the outcropping geological formations. The survey resulted in two maps of dose equivalent rate, related to pre-anthropic and present conditions. Presently, the average of the dose equivalent rate from ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz247

    authors: Daniela G,Carloni S,Voltaggio M,Di Lisa GA

    更新日期:2019-12-31 00:00:00

  • Medical management of radiation accidents: capabilities and deployment principles of the Bundeswehr Institute of Radiobiology.

    abstract::Radiation accidents are fortunately infrequent occurrences, but since their consequences can be very serious as in the Chernobyl and the Fukushima nuclear accidents, medical management of radiation accidents is of great importance. Besides several other tasks, medical management of radiation accidents is one of the ke...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs159

    authors: Dörr H,Meineke V

    更新日期:2012-10-01 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00

  • Feminist theoretical perspectives on ethics in radiology.

    abstract::The substantive safety of radiological and other medical procedures can be radically reduced by unconscious factors governing scientific thought. In addition, the historical exclusion of women from these disciplines has possibly skewed their development in directions that now need to be addressed. This paper focuses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp055

    authors: Condren M

    更新日期:2009-07-01 00:00:00

  • Defect complexes in Re3+-doped magnesium sulphate phosphors.

    abstract::A series of magnesium sulphate phosphors MgSO4:RE3+,X ( RE = Dy, Tm, Eu and X = P, Mn) have been prepared and studied. Based on the experimental results of thermoluminescence (TL) emission spectra and dose responses studies, it is proposed that in these phosphors large defect complexes are formed, which include intrin...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci680

    authors: Luo DL,Tang Q,Zhang CX

    更新日期:2006-01-01 00:00:00

  • Terrestrial gamma radioactivity levels and their corresponding extent exposure of environmental samples from Wadi El Assuity protective area, Assuit, Upper Egypt.

    abstract::Representative environmental samples (sandy soil, limestone, marble and gravels) collected from Wadi El Assuity, protective area, Assuit governorate in Upper Egypt have been investigated radiometrically using NaI (Tl) gamma-ray spectrometer. The specific activity of the radionuclides in Bq kg⁻¹ for soil ranged between...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq425

    authors: El-Taher A

    更新日期:2011-06-01 00:00:00

  • Comparison of results from quality control of physical parameters and results from clinical evaluation of mammographic images for the mammography screening facilities in Poland.

    abstract::The material for this study comprised control protocols from 248 mammography screening facilities, prepared by physicists employed at 16 Regional Coordinating Centres and the results from the clinical evaluation of mammographic images in 248 facilities in Poland. All mammograms were evaluated independently by three ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncr321

    authors: Fabiszewska E,Grabska I,Jankowska K,Wesolowska E,Bulski W

    更新日期:2011-09-01 00:00:00

  • THE GEOGENIC RADON POTENTIAL MAP OF THE ASPIRING 'BUZĂU LAND' GEOPARK.

    abstract::Mapping the geogenic radon potential in Buzău County is part of a research project aiming to apply research for sustainable development and economic growth following the principles of geoconservation in order to support the 'Buzău Land' UNESCO Geopark initiative. The mapping of geogenic radon will be used as an overvi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx143

    authors: Moldovan MC,Burghele BD,Roba CA,Sferle TL,Buterez C,Mitrofan H

    更新日期:2017-11-01 00:00:00

  • EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE.

    abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa125

    authors: Krmar M,Milić K,Arsenić I,Hansman J

    更新日期:2020-10-16 00:00:00

  • Radiation effects in cultured tumour cells examined by 1H MRS: mobile lipids modulation and proliferative arrest.

    abstract::Much attention has been devoted in the past to monitor changes of mobile lipid (ML) (1)H MRS signals in spectra of tumour cells. The purpose of this work is to exploit ML signals to provide information on cell metabolism after irradiation, comparing tumour cells characterised by different radiosensitivity and relating...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl517

    authors: Grande S,Giovannini C,Luciani AM,Palma A,Rosi A,Sapora O,Viti V,Guidoni L

    更新日期:2006-01-01 00:00:00

  • QUANTITATIVE AND QUALITATIVE STUDY OF RADON CONTENT IN BULGARIAN MINERAL WATERS.

    abstract::This study presents the results of 222Rn in 24 sources of mineral water, 54 samples from different captured natural springs and drillings. 222Rn determination was performed by direct measurement using Alpha Guard with Aqua Kit. The results for the TDS, anions (F-, Cl-, SO42-), cations (Na+, Ca2+, Mg2+), pH and tempera...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy089

    authors: Kamenova-Totzeva RM,Totzev AV,Kotova RM,Ivanova-Teneva GR

    更新日期:2018-09-01 00:00:00

  • Radiation dose survey in a paediatric cardiac catheterisation laboratory equipped with flat-panel detectors.

    abstract::Flat-panel X-ray detectors for fluoroscopy represent a modern imaging equipment that is being implemented in paediatric cardiac catheterisation laboratories. Infants and children represent a group of patients with a high radiosensitivity. A survey of 273 (126 diagnostic and 147 therapeutic) paediatric catheterisations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn035

    authors: Dragusin O,Gewillig M,Desmet W,Smans K,Struelens L,Bosmans H

    更新日期:2008-01-01 00:00:00

  • In vivo thyroid 131I monitoring system using an imaging plate.

    abstract::The counting efficiency and detection limit of an in vivo thyroid 131I monitoring system using an imaging plate (IP) were estimated using an anthropomorphic thyroid neck phantom. The counting efficiency of the IP system was approximately constant for thyroid volumes between 11.7 and 20 ml and neck diameters between 10...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006025

    authors: Hirota M,Saze T,Nishizawa K

    更新日期:2002-01-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • Evaluation of the radioactivity of the pre-dominant gamma emitters in components used at high-energy proton accelerator facilities.

    abstract::At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl475

    authors: Numajiri M

    更新日期:2007-01-01 00:00:00

  • A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    abstract::Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw266

    authors: Bonin A,Tsilanizara A

    更新日期:2017-06-01 00:00:00