The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography.

Abstract:

:The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction (AIDR) reconstruction techniques. Further aim was to implement prospective electrocardiogram (ECG) gating for patient dose reduction. The study was performed with Aquilion ONE 320-row CT of Toshiba Medical Systems. Analysis of cardiac CT protocols was performed before and after integration of the new software. The AIDR technique showed more than 50 % reduction in CTDIvol values and 57 % in effective dose. The subjective evaluation of clinical images confirmed the adequate image quality acquired by the AIDR technique. The preliminary results indicated significant dose reduction when using prospective ECG gating by keeping the adequate diagnostic quality of clinical images.

journal_name

Radiat Prot Dosimetry

authors

Dyakov I,Stoinova V,Groudeva V,Vassileva J

doi

10.1093/rpd/ncv114

subject

Has Abstract

pub_date

2015-07-01 00:00:00

pages

182-4

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

ncv114

journal_volume

165

pub_type

杂志文章
  • COMPARISON STUDY OF VARIOUS PLASTICS AS THE WALL MATERIAL OF THGEM-BASED MICRODOSEMETERS FOR FAST NEUTRON MEASUREMENTS.

    abstract::To find appropriate substitutions for the expensive plastics of A-150 and rexolite used in the construction of thick gas electron multiplier (THGEM)-based tissue-equivalent proportional counters, in the present work, the responses of a THGEM-based microdosimetric detector made of A-150 and rexolite and three others co...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw008

    authors: Moslehi A,Raisali G,Lamehi M

    更新日期:2017-04-15 00:00:00

  • Photoneutron and capture gamma dose equivalent for different room and maze layouts in radiation therapy.

    abstract::In this paper the effect of treatment room and maze layout on the photoneutron and capture gamma dose equivalent in the maze was studied. MCNPX Monte Carlo (MC) code was used to simulate the Varian 2100 C/D Clinac 18 MV and four different room layouts. Two analytical methods, Wu-McGinley and McGinley, were used for do...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp303

    authors: Mesbahi A,Ghiasi H,Mahdavi SR

    更新日期:2010-08-01 00:00:00

  • EPR DOSIMETRY STUDY FOR POPULATION RESIDING IN THE VICINITY OF FALLOUT TRACE FOR NUCLEAR TEST ON 7 AUGUST 1962.

    abstract::The method of electron paramagnetic resonance (EPR) dosimetry using extracted teeth has been applied to human tooth enamel to obtain individual absorbed doses of residents of settlements in the vicinity of the central axis of radioactive fallout trace from the contaminating surface nuclear test on 7 August 1962. Most ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw178

    authors: Zhumadilov KS,Ivannikov AI,Stepanenko VF,Toyoda S,Skvortsov VG,Hoshi M

    更新日期:2016-12-01 00:00:00

  • Lessons of the 3rd international intercomparison on EPR dosimetry with teeth: similarities and differences of two successful techniques.

    abstract::Despite the considerable improvement in accuracy in comparison with previous intercomparison programmes, the outcome of the recent 3rd International Intercomparison on EPR Tooth Dosimetry has demonstrated that performance of various protocols practised in different laboratories significantly varies. SCRM and MUG took ...

    journal_title:Radiation protection dosimetry

    pub_type:

    doi:10.1093/rpd/nci644

    authors: Chumak V,Ciesielski B,Sholom S,Schultka K

    更新日期:2006-01-01 00:00:00

  • TWO NEW SINGLE-EXPOSURE, MULTI-DETECTOR NEUTRON SPECTROMETERS FOR RADIATION PROTECTION APPLICATIONS IN WORKPLACE MONITORING.

    abstract::This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw349

    authors: Gómez-Ros JM,Bedogni R,Bortot D,Domingo C,Esposito A,Introini MV,Lorenzoli M,Mazzitelli G,Moraleda M,Pola A,Sacco D

    更新日期:2017-04-01 00:00:00

  • Measured proton sensitivities of bubble detectors.

    abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch330

    authors: Takada M,Kitamura H,Koi T,Nakamura T,Fujitaka K

    更新日期:2004-01-01 00:00:00

  • Determination of the minimum measurement time for estimating long-term mean radon concentration.

    abstract::Radon measurements, as do any measurements, include errors in their readings. The relative values of such errors depend principally on the measurement methods used, the radon concentration to be measured and the duration of the measurements. Typical exposure times for radon surveys using passive detectors [nuclear tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs217

    authors: Janik M,Łoskiewicz J,Tokonami S,Kozak K,Mazur J,Ishikawa T

    更新日期:2012-11-01 00:00:00

  • Determination of natural radioactivity in building materials used in Tunisian dwellings by gamma ray spectrometry.

    abstract::The radioisotopic content of 17 samples of natural and manufactured building materials collected in Tunisia have been analysed by using gamma spectrometry. From the measured gamma ray spectra, activity concentrations are determined for (232)Th, (226)Ra, (235)U and (40)K. The total effective dose and the activity conce...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch489

    authors: Hizem N,Ben Fredj A,Ghedira L

    更新日期:2005-01-01 00:00:00

  • Implications of the space radiation environment for human exploration in deep space.

    abstract::Human exploration of the solar system beyond Earth's orbit will entail many risks for the crew on these deep space missions. One of the most significant health risks is exposure to the harsh space radiation environment beyond the protection provided by the Earth's intrinsic magnetic field. Crew on exploration missions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci141

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • Modelling of nuclear power plant decommissioning financing.

    abstract::Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv333

    authors: Bemš J,Knápek J,Králík T,Hejhal M,Kubančák J,Vašíček J

    更新日期:2015-06-01 00:00:00

  • Air kerma to HP(3) conversion coefficients for photons from 10 keV to 10 MeV, calculated in a cylindrical phantom.

    abstract::In the framework of the ORAMED project (Optimization of RAdiation protection for MEDical staff), funded by the European Union Seventh Framework Programme, different studies were aimed at improving the quality of radiation protection in interventional radiology and nuclear medicine. The main results of the project were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs269

    authors: Gualdrini G,Bordy JM,Daures J,Fantuzzi E,Ferrari P,Mariotti F,Vanhavere F

    更新日期:2013-05-01 00:00:00

  • BAYESIAN SPECTRUM DECONVOLUTION INCLUDING UNCERTAINTIES AND MODEL SELECTION: APPLICATION TO X-RAY EMISSION DATA USING WINBUGS.

    abstract::Spectrum deconvolution is an important task in ionizing radiation measurements, as the pulse height spectra, or, in general, the measured data from spectrometers or other measuring instruments are usually determined by the convolution of the response function with the fluence spectra. The method presented here for obt...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy286

    authors: Behrens R,Reginatto M

    更新日期:2019-12-23 00:00:00

  • Lithium fluoride: from LiF:Mg,Ti to LiF:Mg,Cu,P.

    abstract::Differences and similarities between LiF-based LiF:Mg,Ti and LiF:Mg,Cu,P are discussed, with respect to their dosimetric properties--sensitivity, non-linearity of dose response and heavy charged particle efficiency, as related to the concentration and the individual role of the Mg, Ti, Cu and P dopants. To study furth...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005847

    authors: Bilski P

    更新日期:2002-01-01 00:00:00

  • Radon in private drinking water wells.

    abstract::At least 10% of inhabitants in the Czech Republic are supplied with water from private sources (private wells, boreholes). With the increasing cost of water, the number of people using their own sources of drinking water will be likely to increase. According to the Decree of the State Office for Nuclear Safety about t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu095

    authors: Otahal P,Merta J,Burian I

    更新日期:2014-07-01 00:00:00

  • Neutron calibration facility with radioactive neutron sources at KRISS.

    abstract::For the purpose of radiation protection, the reference neutron field for calibration of neutron monitors was constructed using radioactive neutron sources-bare-(252)Cf, D(2)O-moderated (252)Cf and (241)Am-Be(alpha,n)-at Korea Research Institute of Standards and Science (KRISS). The well-specified neutron source with i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm034

    authors: Park H,Kim J,Choi KO

    更新日期:2007-01-01 00:00:00

  • Indoor radon measurements in Turkey dwellings.

    abstract::In this work, indoor radon radioactivity concentration levels have been measured in dwellings of Turkey within the frame of the National Radon Monitoring Programme. The (222)Rn concentrations were measured with time-integrating passive nuclear etched track detectors in 7293 dwellings in 153 residential units of 81 pro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu329

    authors: Celebi N,Ataksor B,Taskın H,Bingoldag NA

    更新日期:2015-12-01 00:00:00

  • Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation.

    abstract::In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiograp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr355

    authors: Paulo G,Santos J,Moreira A,Figueiredo F

    更新日期:2011-09-01 00:00:00

  • Modelling the 137Cs ingestion dose from consumption of marine fish in Hong Kong.

    abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006710

    authors: Poon CB,Au SM

    更新日期:2002-01-01 00:00:00

  • Radiation protection culture: a global challenge.

    abstract::The central motto 'Radiation Protection Culture-A Global Challenge' of the fourth European IRPA Congress is discussed on the basis of the IRPA Guiding Principles Establishing a Radiation Protection Culture and the contributions presented in the plenary sessions of the conference. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu325

    authors: Michel R,Henrichs K,Wernli C

    更新日期:2015-04-01 00:00:00

  • Personal radon dosimetry from eyeglass lenses.

    abstract::Eyeglass lenses are commonly composed of allyl-diglycol carbonate (CR-39), an alpha-particle detecting plastic, thus making such lenses personal radon dosemeters. Samples of such lenses have been obtained, etched to reveal that radon and radon progeny alpha tracks can be seen in abundance, and sensitivities have been ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006670

    authors: Fleischer RL,Meyer NR,Hadley SA,MacDonald J,Cavallo A

    更新日期:2001-01-01 00:00:00

  • Fetal radiation dose in computed tomography.

    abstract::The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv097

    authors: Kelaranta A,Kaasalainen T,Seuri R,Toroi P,Kortesniemi M

    更新日期:2015-07-01 00:00:00

  • Medical management of radiation accidents: capabilities and deployment principles of the Bundeswehr Institute of Radiobiology.

    abstract::Radiation accidents are fortunately infrequent occurrences, but since their consequences can be very serious as in the Chernobyl and the Fukushima nuclear accidents, medical management of radiation accidents is of great importance. Besides several other tasks, medical management of radiation accidents is one of the ke...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs159

    authors: Dörr H,Meineke V

    更新日期:2012-10-01 00:00:00

  • Radiation protection at Hadron therapy facilities.

    abstract::The Italian National Centre for Oncological Hadrontherapy is currently under construction in Pavia. It is designed for the treatment of deep-seated tumours (up to a depth of 27 cm of water equivalent) with proton and C-ion beams as well as for both clinical and radiobiological research. The particles will be accelerat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr242

    authors: Pelliccioni M

    更新日期:2011-07-01 00:00:00

  • Deformation luminescence produced during application and release of pressure on to gamma-irradiated CaF2:RE crystals.

    abstract::Calcium fluoride CaF2 is an interesting host lattice for rare earth (RE) activators. CaF2 crystals doped with different concentrations of Dy, Ce, Er and Gd have been grown by the Bridgman technique and their deformation luminescence (DL) induced by room temperature gamma irradiation has been recorded. When a uniaxial ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci606

    authors: Kher RS,Brahme N,Banerjee M,Dhoble SJ,Khokhar MS

    更新日期:2006-01-01 00:00:00

  • Early faecal excretion of inhaled plutonium.

    abstract::Special individual monitoring has been performed for suspected cases of inhalation of plutonium at the Tokai Works of the Japan Nuclear Cycle Development Institute (JNC). Some experimental data obtained from this special individual monitoring during the past 20 years are presented and discussed in this paper. Our expe...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006082

    authors: Kurihara O,Momose T,Tasaki T,Hayashi N,Shinohara K

    更新日期:2002-01-01 00:00:00

  • 238U CONTENT IN URINE OF URANIUM MINERS AND ITS MODELED VALUES.

    abstract::The aim of the study is to make a comparison of daily 238U excretion in urine among 115 active uranium miners and its modeled values obtained from inhalation intake of long-lived alpha emitters as measured by personal dosemeters and assessed by biokinetic models for different absorption parameters settings for inhaled...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx061

    authors: Kotík L,Becková V,Malátová I,Tomasek L

    更新日期:2017-12-01 00:00:00

  • CAN HALF VALUE LAYER MEASUREMENTS BE USED TOGETHER WITH THE EFFECTIVE ENERGY TO OBTAIN CONVERSION COEFFICIENTS FOR X-RAY SPECTRA?

    abstract::Conversion coefficients are a substantial vehicle in practical radiation protection to determine the dose (rate) of a given radiation field. According to ICRU report 57, their values shall be obtained by means of spectrometry. This is, however, a time-consuming complicated procedure that cannot be performed by all dos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw003

    authors: Behnke B,Hupe O

    更新日期:2017-04-15 00:00:00

  • Radioactivity and dose assessment of marble samples from Igbeti mines, Nigeria.

    abstract::The concentration and distribution of natural radionuclides in marble around Igbeti marble mines, Nigeria, were measured to evaluate the environmental radioactivity and health effects which the marble samples may posses. The concentration of radionuclides was determined using gamma-ray spectrometry with NaI (Tl) detec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn279

    authors: Ademola AK,Hammed OS,Adejumobi CA

    更新日期:2008-01-01 00:00:00

  • Risk management policies and practices regarding radio frequency electromagnetic fields: results from a WHO survey.

    abstract::This study aims to describe current risk management practices and policies across the world in relation to personal exposures from devices emitting radiofrequency fields, environmental exposures from fixed installations and exposures in the work environment. Data from 86 countries representing all WHO regions were col...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu324

    authors: Dhungel A,Zmirou-Navier D,van Deventer E

    更新日期:2015-04-01 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00