Abstract:
:This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coefficients provided by the International Commission on Radiological Protection (ICRP) were used for the estimation. The highest mean cumulative badge doses (26.87 mSv) were observed in radiologists, followed by radiologic technologists (15.96 mSv). Male workers exhibited higher mean cumulative badge doses, across occupational groups. The estimated organ doses showed similar trends with those of badge doses. Organs located outside the apron's coverage such as the thyroid showed higher mean organ doses than those protected by the apron. Our findings could contribute to future radiation epidemiologic studies to investigate health effects from occupational radiation exposure in Korea.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee Wdoi
10.1093/rpd/ncx239subject
Has Abstractpub_date
2018-04-01 00:00:00pages
142-150issue
2eissn
0144-8420issn
1742-3406pii
4585860journal_volume
179pub_type
杂志文章abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncm462
更新日期:2008-01-01 00:00:00
abstract::Doses in radiology should be as low as reasonably achievable. In order to compare practice in different centres it is necessary to compare patient doses. This can only be undertaken if dosimetry studies are similar. In order to facilitate comparisons, the DIMOND consortium developed a patient dosimetry protocol. Refer...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci715
更新日期:2005-01-01 00:00:00
abstract::The Laboratory of External Dosimetry Studies and Researches (LRDE), associated laboratory to the Bureau National de Métrologie, is strongly involved in the reference establishment and calibration of instruments in neutron radiation fields provided by 241Am-Be, 252Cf and (252Cf + D2O)/Cd sources. In 1997, on the reques...
journal_title:Radiation protection dosimetry
pub_type: 指南,杂志文章,多中心研究
doi:10.1093/rpd/nch193
更新日期:2004-01-01 00:00:00
abstract::The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv114
更新日期:2015-07-01 00:00:00
abstract::The occupational radiation exposure of medical radiation workers at the Institute of Oncology, Vilnius University (IOVU) was analysed. Quartile dose measurements were collected and routinely analysed for a period of 8 y from 1 January 2004 to 31 December 2011. A total of 193 medical radiation workers were monitored, c...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct111
更新日期:2013-11-01 00:00:00
abstract::Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impos...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa209
更新日期:2021-01-13 00:00:00
abstract::The dependence of the doses on solar activity for intermediate levels of the solar modulation parameter has been studied by means of simulations carried out by the Monte Carlo transport code FLUKA. The vertical cut-off rigidities investigated lie between 0.4 and 6.1 GV. The calculated results show that the linear depe...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006099
更新日期:2002-01-01 00:00:00
abstract::The purpose of this study was to establish a dose estimation tool with Monte Carlo (MC) simulations. A 5-y-old paediatric anthropomorphic phantom was computed tomography (CT) scanned to create a voxelised phantom and used as an input for the abdominal cone-beam CT in a BEAMnrc/EGSnrc MC system. An X-ray tube model of ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp257
更新日期:2010-03-01 00:00:00
abstract::Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv232
更新日期:2015-11-01 00:00:00
abstract::The personnel dosimetry department of the Greek Atomic Energy Commission (GAEC) assures the individual monitoring of almost 8000 occupationally exposed workers. Thermoluminescence dosimetry systems will replace the existing photographic dosimetry system for the individual monitoring with the joint support of IAEA and ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006582
更新日期:2001-01-01 00:00:00
abstract::This paper presents an efficient algorithm for estimating the unknown emission rate of radionuclides in the atmosphere following a nuclear accident. The algorithm is based on assimilation of gamma dose rate measured data in a Lagrangian atmospheric dispersion model. Such models are used in the framework of nuclear eme...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq592
更新日期:2012-01-01 00:00:00
abstract::An investigation of the thermoluminescence (TL) properties of high pressure, high temperature (HPHT) synthetic diamond crystals grown under diluted nickel or cobalt as solvent catalysts is reported. After a study of TL properties of 6 different samples, it is shown that a crystal grown with Ni+2%Ti and annealed at 210...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a005880
更新日期:2002-01-01 00:00:00
abstract::Neutron therapy beams are obtained by accelerating protons or deuterons on Beryllium. These neutron therapy beams present comparable dosimetric characteristics as those for photon beams obtained with linear accelerators; for instance, the penetration of a p(65)+Be neutron beam is comparable with the penetration of an ...
journal_title:Radiation protection dosimetry
pub_type: 指南,杂志文章,实务指引,评审
doi:10.1093/rpd/nch221
更新日期:2004-01-01 00:00:00
abstract::Estimating organ absorbed doses in consideration of person-specific parameters is important for radiation protection in diagnostic nuclear medicine. This study proposes a straightforward method for estimating the organ dose that reflects a specific organ mass by scaling the reference organ dose using the inverse ratio...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncaa058
更新日期:2020-07-24 00:00:00
abstract::In order to check developed software tools, it was necessary to compare estimates of statistical characteristics of annual absorbed plutonium internal doses obtained by PANDORA and IMBA software with the same original data. The results were compared from dose calculations of five cases with different initial data on p...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncx085
更新日期:2017-11-01 00:00:00
abstract::A follow-up study was taken up in a mineralised zone situated in Hamirpur district, Himachal Pradesh, India, to investigate high values of radon concentrations reported in past studies as well to update the old radon data based on bare SSNTD technique. In the present investigation, the concentrations of indoor radon, ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncv367
更新日期:2016-03-01 00:00:00
abstract::Potassium-40 constitutes the main natural source of potassium present in the body, which influences the effective dose received by people. With the aim of assessing the contribution of this component to the doses received by the Cuban population, a study intended to assess the doses was developed. For this purpose, a ...
journal_title:Radiation protection dosimetry
pub_type: 临床试验,杂志文章
doi:10.1093/oxfordjournals.rpd.a006187
更新日期:2003-01-01 00:00:00
abstract::Fluorescent in situ hybridisation analysis of stable translocations was performed for 26 residents living along the Techa River (Russia), who were predominantly (95%) exposed to ingested strontium radioisotopes ((89)Sr and (90)Sr) resulting in exposure of their red bone marrow (RBM). Analysis was conducted at the Ural...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu131
更新日期:2014-06-01 00:00:00
abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a032854
更新日期:1999-01-01 00:00:00
abstract::The paper presents the first results of an investigation on optical absorption (OA), thermally and infrared stimulated luminescence (TL and IRSL) of the Pinacate plagioclase (labradorite). The OA spectra reveal two bands with maxima at 1.0 and 3.2 eV connected with absorption of the Fe3+ and Fe2+ and IR absorption at ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci643
更新日期:2006-01-01 00:00:00
abstract::Dose metrics on intraoral and panoramic dental radiography were analyzed to preliminarily indicate dose trend of dental radiology equipment in Indonesia. Measurements were performed in 71 healthcare institutions involving a total of 92 dental X-ray devices. Imaging modes are categorized into 'low dose' and 'high dose'...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,多中心研究
doi:10.1093/rpd/ncy123
更新日期:2019-05-01 00:00:00
abstract::Composite neutron scintillators consisting of neutron-insensitive fluorescent dopant particles (e.g. ZnS:Ag) embedded in a matrix material containing isotopes with high neutron cross sections that emit energetic charged particles (e.g. 6Li) are a popular method for neutron detection in a variety of applications. The s...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci121
更新日期:2005-01-01 00:00:00
abstract::Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Institute of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation qua...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch111
更新日期:2004-01-01 00:00:00
abstract::Hydrogen-filled proportional counters perform well as neutron spectrometers in the energy region from a few tens of keV up to ∼1.5 MeV. Unfortunately, gamma rays also generate signals in these detectors. It is possible in principle to distinguish the two types of event via the rise time of their respective signal puls...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nct262
更新日期:2014-10-01 00:00:00
abstract::AVIDOS is a computer code used for the dose assessment of aircraft crew exposed to cosmic radiation. The code employs a multiparameter model built upon simulations of cosmic radiation exposure done using the FLUKA Monte Carlo code. AVIDOS calculates both ambient dose equivalent H*(10) and effective dose E for flight r...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp126
更新日期:2009-10-01 00:00:00
abstract::One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some eff...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006064
更新日期:2002-01-01 00:00:00
abstract::At the low doses (and low dose rates) relevant to environmental and occupational radiation exposure (0-50 mSv), which are of practical concern for radiation protection, very few cells in the human organism experience more than one traversal by densely ionising particles in their lifetime, the intervals between the tra...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncl444
更新日期:2006-01-01 00:00:00
abstract::223Ra is a radiopharmaceutical used as unsealed source in nuclear medicine. In the case of staff inhalation contamination of 223Ra, methods to estimate the committed effective dose should be chosen with care. Three methods are available: whole-body measurement and gamma spectrometry for urine or faeces samples. Consid...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncy065
更新日期:2018-12-01 00:00:00
abstract::Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calc...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw302
更新日期:2017-04-01 00:00:00
abstract::A new procedure allowing the separate estimation of neutron and gamma dose in mixed radiation fields has been developed in our laboratory. In this communication, a description of the main features of the discrimination procedure and some preliminary results obtained by its use are presented. The procedure is based on ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm210
更新日期:2007-01-01 00:00:00