Emission rate estimation through data assimilation of gamma dose measurements in a Lagrangian atmospheric dispersion model.

Abstract:

:This paper presents an efficient algorithm for estimating the unknown emission rate of radionuclides in the atmosphere following a nuclear accident. The algorithm is based on assimilation of gamma dose rate measured data in a Lagrangian atmospheric dispersion model. Such models are used in the framework of nuclear emergency response systems (ERSs). It is shown that the algorithm is applicable in both deterministic and stochastic modes of operation of the dispersion model. The method is evaluated by computational simulations of a 3-d field experiment on atmospheric dispersion of ⁴¹Ar emitted routinely from a research reactor. Available measurements of fluence rate (photons flux) in air are assimilated in the Lagrangian dispersion model DIPCOT and the ⁴¹Ar emission rate is estimated. The statistical analysis shows that the model-calculated emission rates agree well with the real ones. In addition the model-predicted fluence rates at the locations of the sensors, which were not used in the data assimilation procedure are in better agreement with the measurements. The first evaluation results of the method presented in this study show that the method performs satisfactorily and therefore it is applicable in nuclear ERSs provided that more comprehensive validation studies will be performed.

journal_name

Radiat Prot Dosimetry

authors

Tsiouri V,Kovalets I,Andronopoulos S,Bartzis JG

doi

10.1093/rpd/ncq592

subject

Has Abstract

pub_date

2012-01-01 00:00:00

pages

34-44

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncq592

journal_volume

148

pub_type

杂志文章
  • Radon diffusion coefficients in 360 waterproof materials of different chemical composition.

    abstract::This paper summarises the results of radon diffusion coefficient measurements in 360 common waterproof materials available throughout Europe. The materials were grouped into 26 categories according to their chemical composition. It was found that the diffusion coefficients of materials used for protecting houses again...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr043

    authors: Jiránek M,Kotrbatá M

    更新日期:2011-05-01 00:00:00

  • Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory.

    abstract::The purpose of the study was to evaluate the dose performance of a flat-panel (FP) and an image intensifier (II) charge coupled device (CCD) digital fluoroscopy X-ray systems newly installed in an Interventional Cardiology (IC) department. Filter entrance dose rate, detector dose rate (during fluoroscopy) and filter e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch344

    authors: Tsapaki V,Kottou S,Kollaros N,Dafnomili P,Kyriakidis Z,Neofotistou V

    更新日期:2004-01-01 00:00:00

  • International action plan on the radiation protection of patients.

    abstract::Realising that the major part of radiation protection efforts had been directed for over half a century at radiation protection of workers, and that there are major issues in relation to medical exposure, which contributes to over 95 % of the dose to the global population from man-made sources, with increasing individ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr258

    authors: Rehani MM,Holmberg O,Ortiz López P,Mettler F

    更新日期:2011-09-01 00:00:00

  • Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.

    abstract::Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci586

    authors: Ginjaume M,Pérez S,Ortega X,Duch MA

    更新日期:2006-01-01 00:00:00

  • EFFECT OF PATIENT SIZE, ANATOMICAL LOCATION AND MODULATION STRENGTH ON DOSE DELIVERED AND IMAGE-QUALITY ON CT EXAMINATION.

    abstract::To study the effect of patient size, anatomical location and modulation strength (MS) on image-quality and delivered dose of CT scans acquired with automatic-exposure-control system (AEC). Four anthropomorphic phantoms (three paediatric and one thin adult) were studied, and normal and obese adults were simulated by pl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx055

    authors: Greffier J,Larbi A,Macri F,Beregi JP,Pereira F

    更新日期:2017-12-01 00:00:00

  • A software tool for increased efficiency in observer performance studies in radiology.

    abstract::Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-h...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch550

    authors: Börjesson S,Håkansson M,Båth M,Kheddache S,Svensson S,Tingberg A,Grahn A,Ruschin M,Hemdal B,Mattsson S,Månsson LG

    更新日期:2005-01-01 00:00:00

  • Background radiation and individual dosimetry in the costal area of Tamil Nadu, India.

    abstract::South coast of India is known as the high-level background radiation area (HBRA) mainly due to beach sands that contain natural radionuclides as components of the mineral monazite. The rich deposit of monazite is unevenly distributed along the coastal belt of Tamil Nadu and Kerala. An HBRA site that laid in 2×7 m alon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr179

    authors: Matsuda N,Brahmanandhan GM,Yoshida M,Takamura N,Suyama A,Koguchi Y,Juto N,Raj YL,Winsley G,Selvasekarapandian S

    更新日期:2011-07-01 00:00:00

  • Microdosimetric modelling of the response of thermoluminescence detectors to low- and high-LET ionising radiation.

    abstract::The microdosimetric one hit detector model was applied to calculate the dose response, energy response and relative thermoluminescence (TL) efficiency, eta, of high sensitive LiF:Mg,Cu,P and Al(2)O(3):C detectors after their irradiations by X rays, gamma rays, beta electrons and heavy charged particles (HCP). Microdos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl467

    authors: Olko P,Bilski P,Budzanowski M,Czopyk L,Swakon J,Waligorski MP

    更新日期:2006-01-01 00:00:00

  • Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes.

    abstract::Internal contamination due to high-energy photon (HEP) emitters is assessed using a scanning bed whole-body monitor housed in a steel room at the Bhabha Atomic Research Centre (BARC). The monitor consists of a (203 mm diameter × 102 mm thickness) NaI(Tl) detector and is calibrated using a Reference BOMAB phantom repre...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr203

    authors: Bhati S,Patni HK,Ghare VP,Singh IS,Nadar MY

    更新日期:2012-03-01 00:00:00

  • Reconstruction of cluster distributions at 100% detection efficiency for a track-nanodosimetric counter through a Bayesian analysis.

    abstract::A Bayesian unfolding has been applied to ionisation distributions due to 5.4 MeV alpha particles in a 20-nm site obtained using Monte Carlo simulations, taking into account different detection efficiency conditions. The ideal case of a target volume with uniform efficiency has been investigated to study the dependence...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch143

    authors: De Nardo L,Lesimple M,Canella S,Grosswendt B

    更新日期:2004-01-01 00:00:00

  • Gamma-ray rejection, or detection, with gadolinium as a converter.

    abstract::Gadolinium is a competent neutron conversion material for neutron detection due to its extremely high neutron capture cross section. It differs from the other neutron reactive materials by emitting large amounts of low-energy electrons for the consequent signal generation in a detector. Such low-energy electrons, thou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs031

    authors: Kandlakunta P,Cao L

    更新日期:2012-09-01 00:00:00

  • Development of lung and soft tissue substitutes for photons.

    abstract::The use of solid tissue substitutes is a well-accepted and common practice in dosimetric studies and in the production of counting standards for radiological protection. However, only a few solid tissue substitutes simulating a particular body tissue with respect to a set of physical characteristics are commercially a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci018

    authors: Kinase S,Kimura M,Noguchi H,Yokoyama S

    更新日期:2005-01-01 00:00:00

  • The study of activity median aerodynamic diameter using imaging plate technique for assessment of effective dose from radon and its decay products.

    abstract::The indoor workplace environment was evaluated for exposure to radon and its decay products at two Universities in two metropolises of Japan. The mean radon concentrations in Nagoya University (NU) and Hokkaido University (HU) were 16.7 Bq m(-3) and 18.0 Bq m(-3), respectively. Activity median aerodynamic diameter (AM...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncm221

    authors: Rahman NM,Iida T,Yamazawa H,Yokoyama S,Moriizumi J,Saito F,Ito T

    更新日期:2007-01-01 00:00:00

  • Screen-film versus digital radiography of sacroiliac joints: evaluation of image quality and dose to patients.

    abstract::The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs315

    authors: Jablanovic D,Ciraj-Bjelac O,Damjanov N,Seric S,Radak-Perovic M,Arandjic D,Maksimovic R

    更新日期:2013-06-01 00:00:00

  • A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.

    abstract::The use of the parallel-plate avalanche counter for slow-neutron counting is described. The choice of a suitable neutron converter is discussed on the basis of Monte Carlo simulation, and some experimental results are shown. Excellent gamma-insensitivity, high rate capability, possibility of construction in large sens...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm462

    authors: Nakhostin M,Baba M,Itoga T,Oishi T,Unno Y,Kamada S,Okuji T

    更新日期:2008-01-01 00:00:00

  • Assessment of radiographic screen-film systems: a comparison between the use of a microdensitometer and a drum film digitiser.

    abstract::A high-end drum film digitiser (Tango, Germany) and a calibrated linear microdensitometer developed by PTB were used to assess the modulation transfer function (MTF) and the noise power spectra (NPS) of 3 mammographic screen film systems at optical density levels of 0.8, 1.5 and 2.5. The use of a drum scanner to asses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch563

    authors: Verdun FR,Pachoud M,Bergmann D,Buhr E

    更新日期:2005-01-01 00:00:00

  • DESIGN DEVELOPMENT OF A PASSIVE NEUTRON DOSEMETER FOR THE USE AT HIGH-ENERGY ACCELERATORS.

    abstract::For the radiation survey at intermediate and high-energy accelerators, there is a need for a neutron dosemeter which provides reliable readings of the neutron dose in a wide energy range for continuous and pulsed radiation. The objective of this development is to find a dosemeter that fulfils the necessary requirement...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv489

    authors: Sokolov A,Fehrenbacher G,Radon T

    更新日期:2016-09-01 00:00:00

  • Biodosimetry using chromosome aberrations in human lymphocytes.

    abstract::In vitro dose-response calibration curves for (60)Co gamma rays have been established for unstable chromosome aberrations in human peripheral blood lymphocytes. The observed dose-response data were fitted to a linear quadratic model. The calibration curve parameters were used to estimate the equivalent whole-body dose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl109

    authors: Senthamizhchelvan S,Pant GS,Rath GK,Julka PK,Nair O,Joshi RC,Malhotra A,Pandey RM

    更新日期:2007-01-01 00:00:00

  • MEASUREMENTS OF RADIATION EXPOSURE OF RADIOGRAPHY STUDENTS DURING THEIR CLINICAL TRAINING USING THERMOLUMINESCENT DOSIMETRY.

    abstract::Radiation dose monitoring for radiography students during clinical training is necessary to demonstrate the extent of radiation protection issues present, as well as to instill in them an awareness of safe practices that they will carry with them throughout their careers. The study assess the radiation dose incurred b...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx261

    authors: Abuzaid MM,Elshami W,Steelman C

    更新日期:2018-05-01 00:00:00

  • Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    abstract::In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr252

    authors: Veinot KG,Hertel NE

    更新日期:2012-04-01 00:00:00

  • Optical absorption, TL and IRSL of basic plagioclase megacrysts from the pinacate (Sonora, Mexico) quaternary alkalic volcanics.

    abstract::The paper presents the first results of an investigation on optical absorption (OA), thermally and infrared stimulated luminescence (TL and IRSL) of the Pinacate plagioclase (labradorite). The OA spectra reveal two bands with maxima at 1.0 and 3.2 eV connected with absorption of the Fe3+ and Fe2+ and IR absorption at ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci643

    authors: Chernov V,Paz-Moreno F,Piters TM,Barboza-Flores M

    更新日期:2006-01-01 00:00:00

  • Natural radioactivity levels of geothermal waters and their influence on soil and agricultural activities.

    abstract::All over the world geothermal sources are used for different purposes. The contents of these waters are important to understand positive/negative effects on human life. In this study, natural radioactivity concentrations of geothermal waters were investigated to evaluate the effect on soils and agricultural activities...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct220

    authors: Murat Saç M,Aydemir S,Içhedef M,Kumru MN,Bolca M,Ozen F

    更新日期:2014-01-01 00:00:00

  • RADIATION DOSE IS OF LIMITED CLINICAL USEFULNESS IN PERSONS WITH ACUTE RADIATION SYNDROME.

    abstract::The relation of radiation exposure (dose) with acute radiation syndrome (ARS) depends on many factors. In this overview, we reconsider (1) radiation exposure characteristics (e.g. radiation quality, fractionation, dose rate, partial/total body irradiation) and (2) biological processes (e.g. radiosensitivity, cell cycl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz058

    authors: Port M,Majewski M,Abend M

    更新日期:2019-12-31 00:00:00

  • Development of a radon trap device using a corona discharge.

    abstract::Radon is one of the noble gases, which are chemically inert and do not make any reactants under normal conditions. In this experiment we demonstrated an enigmatic reaction between radon and fluorine when a corona discharge is used as a promoter. Distinctive changes in radon concentrations were caused by the discharge ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci311

    authors: Yamada Y,Koizumi A,Ishikawa K,Hishinuma Y,Tatenuma K

    更新日期:2005-01-01 00:00:00

  • Cytogenetic studies for a group of people living in Japan 1 year after the Fukushima nuclear accident.

    abstract::In order to understand the potential health effect of radiation from Fukushima nuclear disaster, a group of people living in Japan during and after the accident were investigated 1 y after the accident. The venous blood samples were extracted in tune from 156 tested persons living in Tokyo and Niigata with average age...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu180

    authors: Chen Y,Zhou PK,Zhang XQ,Wang ZD,Wang Y,Darroudi F

    更新日期:2014-06-01 00:00:00

  • Entrances skin dose distribution maps for interventional neuroradiological procedures: a preliminary study.

    abstract::Dose estimation in interventional neuroradiology can be useful to limit skin radiation injuries. The purpose of this study was to evaluate the role of entrance skin dose (ESD) maps in planning exposure condition optimisation. Thirteen cerebral angiography and five embolisation procedures were monitored, measuring ESD,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci759

    authors: Rampado O,Ropolo R

    更新日期:2005-01-01 00:00:00

  • High background radiation areas: the case of Villar de la Yegua village (Spain).

    abstract::The starting point of the Spanish experience in the study of High Background Radiation Areas is the development of a nationwide indoor radon survey carried out in 1988. This campaign, belonging to the first Spanish Radon Framework, consisted of approximately 2000 indoor radon measurements which represented a valuable ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm196

    authors: Sáinz C,Quindós LS,Fernández PL,Gómez J,Fuente I,Quindós L,Matarranz JL

    更新日期:2007-01-01 00:00:00

  • Plutonium in the Ozyorsk population.

    abstract::Results of the long-term autopsy studies on plutonium body burden in the population of Ozyorsk situated in the vicinity of the radiochemical plant of the Mayak Production Association (Russia) have been presented. The data were obtained from radiochemical analysis of the soft tissue and bone samples collected at the au...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm303

    authors: Suslova KG,Khokhryakov VF,Sokolova AB

    更新日期:2007-01-01 00:00:00

  • NASA Space Radiation Transport Code Development Consortium.

    abstract::Recently, NASA established a consortium involving the University of Tennessee (lead institution), the University of Houston, Roanoke College and various government and national laboratories, to accelerate the development of a standard set of radiation transport computer codes for NASA human exploration applications. T...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci092

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • General guidelines for the assessment of internal dose from monitoring data: progress of the IDEAS project.

    abstract::In recent major international intercomparison exercises on intake and internal dose assessments from monitoring data, the results calculated by different participants varied significantly. Based on this experience the need for harmonisation of the procedures has been formulated within an EU 5th Framework Programme res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl132

    authors: Doerfel H,Andrasi A,Bailey M,Blanchardon E,Cruz-Suarez R,Berkovski V,Castellani CM,Hurtgen C,LeGuen B,Malatova I,Marsh J,Stather J,Zeger J

    更新日期:2007-01-01 00:00:00