Development of lung and soft tissue substitutes for photons.

Abstract:

:The use of solid tissue substitutes is a well-accepted and common practice in dosimetric studies and in the production of counting standards for radiological protection. However, only a few solid tissue substitutes simulating a particular body tissue with respect to a set of physical characteristics are commercially available. Hence, we have developed polyurethane-based tissue substitutes simulating soft tissue, muscle, muscle-adipose mixture tissue (90% muscle + 10% adipose), brain, cartilage, larynx, thyroid, trachea, liver, kidney, skin and lungs. Tissue substitutes for photons were formulated using the basic data method together with an equation for calculating the optimum relative mass of corrective additives. The tissue substitutes were formulated to be phantom materials in the photon energy range of at least 8 keV-10 MeV. In particular, they were designed to match the body tissues with linear attenuation coefficients for low photon energy (13.6, 17.2 and 20.2 keV from 239Pu) and to have the same mass densities as the tissues. The tissue substitutes developed in the present study were examined for the photon transmissions using 16.6 keV KX rays from 93Nb(m). The experimental transmission curves of the tissue substitutes were found to be consistent with those derived from data on the body tissues in ICRP Publication 23. It was found that the developed tissue substitutes are suitable to the corresponding body tissues defined by ICRP.

journal_name

Radiat Prot Dosimetry

authors

Kinase S,Kimura M,Noguchi H,Yokoyama S

doi

10.1093/rpd/nci018

keywords:

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

284-8

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

115/1-4/284

journal_volume

115

pub_type

杂志文章
  • Albedo Neutron Dosimetry in a Deep Geological Disposal Repository for High-Level Nuclear Waste.

    abstract::Albedo neutron dosemeter is the German official personal neutron dosemeter in mixed radiation fields where neutrons contribute to personal dose. In deep geological repositories for high-level nuclear waste, where neutrons can dominate the radiation field, it is of interest to investigate the performance of albedo neut...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw147

    authors: Pang B,Becker F

    更新日期:2017-04-28 00:00:00

  • Stability of A-150 plastic ionisation chamber response over a approximately 30-y period.

    abstract::At the Northern Illinois University Institute for Neutron Therapy at Fermilab, the clinical tissue-equivalent ionisation chamber response is measured every treatment day using a cesium source that was configured to match readings obtained at the National Bureau of Standards. Daily measurements are performed in air usi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm126

    authors: Kroc TK,Lennox AJ

    更新日期:2007-01-01 00:00:00

  • Indoor concentration of radon, thoron and their progeny around granite regions in the state of Karnataka, India.

    abstract::An extensive studies on the indoor activity concentrations of thoron, radon and their progeny in the granite region in the state of Karnataka, India, has been carried out since, 2007 in the scope of a lung cancer epidemiological study using solid-state nuclear track detector-based double-chamber dosemeters (LR-115, ty...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct243

    authors: Sannappa J,Ningappa C

    更新日期:2014-03-01 00:00:00

  • Reference dosimetry for light-ion beams based on graphite calorimetry.

    abstract::Developments in hadron therapy require efforts to improve the accuracy of the dose delivered to a target volume. Here, the determination of the absorbed dose under reference conditions was analysed. Based on the International Atomic Energy Agency TRS-398 code of practice, for hadron beams, the combined standard uncert...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct299

    authors: Rossomme S,Palmans H,Thomas R,Lee N,Duane S,Bailey M,Shipley D,Bertrand D,Romano F,Cirrone P,Cuttone G,Vynckier S

    更新日期:2014-10-01 00:00:00

  • Deposition of tritiated water vapour to water surface in an outdoor field.

    abstract::Deposition of tritiated water vapour in the atmosphere to a water surface was studied in an outdoor field, where elevated concentrations of tritiated water vapour existed in the atmosphere over twelve days. Exchange velocities of tritiated water vapour between air and water were evaluated from tritium concentrations i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006425

    authors: Noguchi H,Fukutani S,Yokoyama S,Kinouchi N

    更新日期:2001-01-01 00:00:00

  • CHARACTERIZATION OF 27 MEV PROTON BEAM GENERATED BY TOP-IMPLART LINEAR ACCELERATOR.

    abstract::The first proton linear accelerator for tumor therapy based on an actively scanned beam up to the energy of 150 MeV, is under development and construction by ENEA-Frascati, ISS and IFO, under the Italian TOP-IMPLART project. Protons up to the energy of 7 MeV are generated by a customized commercial injector operating ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy001

    authors: De Angelis C,Ampollini A,Basile E,Cisbani E,Della Monaca S,Ghio F,Montereali RM,Picardi L,Piccinini M,Placido C,Ronsivalle C,Soriani A,Strigari L,Trinca E,Vadrucci M

    更新日期:2018-08-01 00:00:00

  • Optically stimulated luminescent glass optical fibre dosemeter.

    abstract::An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005974

    authors: Huston AL,Justus BL,Falkenstein PL,Miller RW,Ning H,Altemus R

    更新日期:2002-01-01 00:00:00

  • Natural Radioactivity of the Crystalline Basement Rocks of the Peloritani Mountains (North-Eastern Sicily, Italy): Measurements and Radiological Hazard.

    abstract::Crystalline rocks can produce dangerous radiation levels on the basis of their content in radioisotopes. Here, we report radiological data from 10 metamorphic and igneous rock samples collected from the crystalline basement of the Peloritani Mountains (southern Italy). In order to evaluate the radiological properties ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa178

    authors: Romano D,Caridi F,Di Bella M,Italiano F,Magazù S,Caccamo MT,Tripodo A,Faggio G,Grillo R,Triolo C,Messina G,Gattuso A,Sabatino G

    更新日期:2020-11-18 00:00:00

  • Measurements of environmental background radiation at location of coal-fired power plants.

    abstract::Environmental radiation monitoring in the vicinity of coal-fired power plants which are used primarily to determine the variability in measured background exposures are presented in this article; this is in order to estimate the contribution due to the plants' operation. Measurements have been done using a multi-eleme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch401

    authors: Adrovic F,Prokić M,Ninković MM,Glisić R

    更新日期:2004-01-01 00:00:00

  • Radiation doses in cerebral perfusion computed tomography: patient and phantom study.

    abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs260

    authors: Arandjic D,Bonutti F,Biasizzo E,Ciraj-Bjelac O,Floreani M,Giustizieri M,Iaiza F,Inkoom S,Tommasini G,Padovani R

    更新日期:2013-05-01 00:00:00

  • Qualifying the use of RIS data for patient dose by comparison with DICOM header data.

    abstract::A system was developed in 2008 to calculate patient doses using Radiology Information System (RIS) data and presents these data as a patient dose audit. One of the issues with this system was the quality of user-entered data. It has been shown that Digital Imaging and Communication in Medicine (DICOM) header data can ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr352

    authors: Wilde R,Charnock P,McDonald S,Moores BM

    更新日期:2011-09-01 00:00:00

  • Radioactive waste management and decommissioning of accelerator facilities.

    abstract::During the operation of high-energy accelerators, the interaction of radiation with matter can lead to the activation of the machine components and of the surrounding infrastructures. As a result of maintenance operation and during decommissioning of the installation, considerable amounts of radioactive waste are evac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp196

    authors: Ulrici L,Magistris M

    更新日期:2009-11-01 00:00:00

  • Lessons of the 3rd international intercomparison on EPR dosimetry with teeth: similarities and differences of two successful techniques.

    abstract::Despite the considerable improvement in accuracy in comparison with previous intercomparison programmes, the outcome of the recent 3rd International Intercomparison on EPR Tooth Dosimetry has demonstrated that performance of various protocols practised in different laboratories significantly varies. SCRM and MUG took ...

    journal_title:Radiation protection dosimetry

    pub_type:

    doi:10.1093/rpd/nci644

    authors: Chumak V,Ciesielski B,Sholom S,Schultka K

    更新日期:2006-01-01 00:00:00

  • STUDY OF DOSES TO HIPPOCAMPUS OF INTERVENTIONAL CARDIOLOGISTS AND THEIR IMPLICATION FOR DOSIMETRIC MONITORING.

    abstract::Dosimetric monitoring and protection of the personnel involved into interventional procedures is one of the key issues nowadays, yet doses received by their brains were left without rigorous consideration so far. The paper is the fast track of the results of the pilot study of possible magnitude of operator's doses wi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw091

    authors: Chumak V,Morgun A,Bakhanova E,Voloskyi V

    更新日期:2016-09-01 00:00:00

  • A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    abstract::The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq002

    authors: Faulkner K,Järvinen H,Butler P,McLean ID,Pentecost M,Rickard M,Abdullah B

    更新日期:2010-04-01 00:00:00

  • Shielding design calculations for beam dump facility of KOMAC.

    abstract::A project to construct the Korea Multi-purpose Accelerator Complex (KOMAC) is currently underway targeting a high-intensity proton beam with an average current of 4.8 mA. As for the first stage of construction, a 20 MeV linac is planned to be built by 2007 and additional DTL sections will be added to increase the prot...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci066

    authors: Cho YS,Lee YO,Chang J

    更新日期:2005-01-01 00:00:00

  • A DISCUSSION ON ISSUES WITH RADON IN DRINKING WATER.

    abstract::The majority of the world's population relies on surface water or large public supply systems of groundwater, where radon is low and a guidance value for radon in drinking water is not necessary. However, the International Commission on Radiological Protection (ICRP) recently issued a dose coefficient for radon ingest...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz035

    authors: Chen J

    更新日期:2019-12-31 00:00:00

  • Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    abstract::Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm455

    authors: Becková V,Malátová I

    更新日期:2008-01-01 00:00:00

  • Thermoluminescence properties of KCl(1-X)KBrX:Pb2+ mixed crystals.

    abstract::A study is presented of the thermoluminescence (TL) of phosphors based on potassium halides doped with divalent lead, such as KCl:Pb2+, KBr:Pb2+ and the crystalline series KCl(1-X)Br(X):Pb2+. The defects in the crystals generated by irradiation have been investigated as well as the trapping and room temperature recomb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005913

    authors: Cruz-Zaragoza E,Meléndrez R,Chernov V,Barboza-Flores M,Piters TM,Hernández JA,Murrieta HS

    更新日期:2002-01-01 00:00:00

  • Validating a MCNPX model of Mg(Ar) and TE(TE) ionisation chambers exposed to 60CO gamma rays.

    abstract::For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm484

    authors: Roca A,Nievaart VA,Moss RL,Stecher-Rasmussen F,Zamfir NV

    更新日期:2008-01-01 00:00:00

  • The newsletter 'European Research in Radiological Sciences'.

    abstract::The newsletter 'European Research in Radiological Sciences' is jointly published by the European Late Effects Project Group and the European Radiation Dosimetry Group to disseminate information about research projects and activities carried out under the EURATOM Framework Programme. Since May 2003, the Newsletter is o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch095

    authors: Pihet P,d'Errico F,Dörr W,Gruenberger M,Schofield P

    更新日期:2004-01-01 00:00:00

  • A study of the correlation between dose area product and effective dose in vascular radiology.

    abstract::The purpose of the multi-centre study was to assess dose area product (DAP) and effective dose of patients undergoing angiography of the lower limbs in Belgium and to investigate the correlation between DAP and effective dose. DAP values were measured in 12 centres and compared with the national diagnostic reference l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn050

    authors: Smans K,Struelens L,Hoornaert MT,Bleeser F,Buls N,Berus D,Clerinx P,Malchair F,Vanhavere F,Bosmans H

    更新日期:2008-01-01 00:00:00

  • The resulting skin dose in two-view mammography examinations.

    abstract::The entrance surface dose (ESD) (skin dose) and its variation due to overlapping radiation fields at mammography have been experimentally investigated on patients during two-view mammography screening examinations of both breasts and on phantoms of silicon gel. Measurements were done using multiple thermoluminescence ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq077

    authors: Adliene D,Cibulskaite I,Laurikaitiene J,Adlys G

    更新日期:2010-04-01 00:00:00

  • Development of a nanotechnology based low-LET multi-microbeam array single cell irradiation system.

    abstract::A novel single cell irradiation system using carbon nanotube (CNT) based field emission technology is proposed. The system can produce electron microbeam at a large range of pulsation frequencies and dose rates with energy between 20 and 60 keV. Different from any existing single beam microbeam device, the CNT-based s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl508

    authors: Chang S,Zhang J,Bordelon D,Schreiber E,Cox A,Zhou O

    更新日期:2006-01-01 00:00:00

  • Analysis of occupational doses of workers on the dose registry of the Federal Radiation Protection Service in 2000 and 2001.

    abstract::In 2000 and 2001 about 279 and 221 radiation workers, respectively, were monitored by the Federal Radiation Protection Service, University of Ibadan, in Nigeria. The distribution of the occupational doses shows that the majority of workers received doses below 4 mSv in each of the two years. The radiation workers in t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006116

    authors: Ogundare FO,Balogun FA

    更新日期:2003-01-01 00:00:00

  • LUMBAR SPINE RADIOGRAPHY: LOWER ORGAN DOSE WITH THE USE OF PA PROJECTION.

    abstract::The purpose of the research was to determine the effect of the posteroanterior (PA) patient position in lumbar spine imaging on effective dose and the absorbed organ dose. The study was performed on 100 patients that were referred to the lumbar spine radiography that were divided into two equal groups of 50. Body Mass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz057

    authors: Alukić E,Mekiš N

    更新日期:2019-12-31 00:00:00

  • Variations of soil radon concentrations along Chite fault in Aizawl district, Mizoram, India.

    abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu221

    authors: Singh S,Jaishi H,Tiwari RP,Tiwari RC

    更新日期:2014-11-01 00:00:00

  • A theoretical study on accurate measurements of thoron with airflow-through scintillation cell method.

    abstract::For accurate measurements of (220)Rn concentration with airflow-through scintillation cell method, a theoretical study was performed for discussing the influences of sampling flow rate, volumes of sampling tube and scintillation cell on the measurements. It is found that a high flow rate and a large inner volume of sc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq252

    authors: Tang F,Zhuo W,Zhao C,Chen B,Xu Y,He L

    更新日期:2010-10-01 00:00:00

  • CAN HALF VALUE LAYER MEASUREMENTS BE USED TOGETHER WITH THE EFFECTIVE ENERGY TO OBTAIN CONVERSION COEFFICIENTS FOR X-RAY SPECTRA?

    abstract::Conversion coefficients are a substantial vehicle in practical radiation protection to determine the dose (rate) of a given radiation field. According to ICRU report 57, their values shall be obtained by means of spectrometry. This is, however, a time-consuming complicated procedure that cannot be performed by all dos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw003

    authors: Behnke B,Hupe O

    更新日期:2017-04-15 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00