Characterisation of workplaces with risks of internal exposures: air sampling.

Abstract:

:The measurement of air samples may be used to assess risks of internal exposures, either by the use of workplace static air samplers (SAS) or personal air samplers (PAS). These measurements need to incorporate information on the physical and chemical nature of the aerosol, and the relationship between the sampled and potentially breathed aerosol. This paper provides an overview of methods, which are typically used in occupational dosimetry to determine these characteristics. A specific practical example is provided to illustrate how SAS are used to determine that potential personal doses are less than 1 mSv per year, and therefore do not require individual monitoring. The paper also discusses the nature and potential impact of the uncertainties associated with PAS monitoring, and how this is managed in practice.

journal_name

Radiat Prot Dosimetry

authors

Roberts GA,Bull RK

doi

10.1093/rpd/ncm397

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

274-9

issue

3

eissn

0144-8420

issn

1742-3406

pii

ncm397

journal_volume

124

pub_type

杂志文章,评审
  • In situ occupational and general public exposure to VHF/UHF transmission for air traffic communication.

    abstract::Occupational and general public exposure due to very high frequency (VHF)/ultra high frequency (UHF) transmission centres for verbal communication for air traffic control is investigated in situ for the first time. These systems are used for communication with aircraft, resulting in different human exposure from that ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs016

    authors: Joseph W,Goeminne F,Verloock L,Vermeeren G,Martens L

    更新日期:2012-09-01 00:00:00

  • Active neutron dosemeters based on microdosimetric principles: research studies.

    abstract::Over the past few years, the Institute for Radiation Protection and Nuclear Safety (IRSN) has been studying a personal electronic neutron dosemeter and an ambient electronic neutron dosemeter based on experimental microdosimetric principles using low pressure proportional counters. The results obtained in 2000 and in ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006808

    authors: Ménard S,Chau Q,Lahaye T

    更新日期:2002-01-01 00:00:00

  • Investigations of thermoluminescence dosimetry in the Techa river flood plain: analysis of the new results.

    abstract::The Techa river region was highly contaminated due to radioactive releases from a nuclear production facility in the period from 1949 to 1956. The inhabitants of the upper Techa river settlements received significant doses of external radiation. The majority of the houses in the upper Techa river villages were demolis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005972

    authors: Bougrov NG,Baturin VA,Goeksu HY,Degteva MO,Jacob P

    更新日期:2002-01-01 00:00:00

  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D

    更新日期:2004-01-01 00:00:00

  • Dosimetric monitoring in Ukraine--present status and path to the future.

    abstract::Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl128

    authors: Chumak V,Boguslavskaya A

    更新日期:2007-01-01 00:00:00

  • Determination of personal dose equivalents in accelerator radiation fields.

    abstract::Values for the dose equivalent are required for radiation protection purposes, but determination of such values can be quite difficult for high energy radiations. The accurate determination of personal dose equivalents in accelerator radiation fields requires the propel use of appropriate radiological quantities and u...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006629

    authors: McDonald JC

    更新日期:2001-01-01 00:00:00

  • Neutron response of the chlorobenzene-ethanol-trimethylpentane dosimetry system.

    abstract::The dosimetric use of the chemical solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator thymolsulphonphthalein. On the basis of the CET solution, an accident and emergency personal dosemeter was designed allowing doses in the r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm042

    authors: Miljanić S,Razem D

    更新日期:2007-01-01 00:00:00

  • Lithium fluoride: from LiF:Mg,Ti to LiF:Mg,Cu,P.

    abstract::Differences and similarities between LiF-based LiF:Mg,Ti and LiF:Mg,Cu,P are discussed, with respect to their dosimetric properties--sensitivity, non-linearity of dose response and heavy charged particle efficiency, as related to the concentration and the individual role of the Mg, Ti, Cu and P dopants. To study furth...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005847

    authors: Bilski P

    更新日期:2002-01-01 00:00:00

  • Application of a CZT detector to in situ environmental radioactivity measurement in the Fukushima area.

    abstract::Instead of conventional Ge semiconductor detectors and NaI(Tl) scintillation spectrometers, an application of a CdZnTe semiconductor (CZT) whose crystal has the dimension of 1 cm cubic to the in situ environmental radioactivity measurement was attempted in deeply affected areas in Fukushima region. Results of depositi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv277

    authors: Kowatari M,Kubota T,Shibahara Y,Fujii T,Fukutani S,Takamiya K,Mizuno S,Yamana H

    更新日期:2015-11-01 00:00:00

  • Electric and magnetic fields generated by ac power lines: an application of advanced modelling tools in order to predict exposure levels.

    abstract::In view of expected legislation changes imposing more severe limits on magnetic flux density, proposals are made based on theory and measurement for adjustment of Fower placement with regard to efficiency, cost and cost-benefit. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006689

    authors: Manco D,Bruzzi L,Soloni A,Valbonetti D,Fabbri S,Violanti S

    更新日期:2001-01-01 00:00:00

  • A review of the properties of the dosimetric systems and the quality assurance programmes of 48 dosimetric services in the European Union and Switzerland.

    abstract::This paper summarises the evaluation of the 1997 EURADOS questionnaire on dosimetric systems able to assess personal dose equivalent. In total, 56 approved dosimetric services in the European Union and Switzerland responded, together monitoring approximately 615,000 occupationally exposed persons. Of these services, 4...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006572

    authors: van Dijk JW,Bordy JM,Vanhavere F,Wernli C,Zamani-Valasiadou M

    更新日期:2001-01-01 00:00:00

  • Recent results of irradiations of DIS-1 dosemeters with an XR200 X-ray flash unit.

    abstract::Earlier measurements have revealed that active electronic dosemeters have deficiencies in pulsed fields of ionising radiation due to the counting technique used. The DIS-1 dosemeter uses a promising technology, which should be basically suitable for measurements in pulsed fields. In this paper, first measurements with...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs265

    authors: Zutz H,Hupe O

    更新日期:2013-05-01 00:00:00

  • ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    abstract::Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy041

    authors: Jeong J,Ko NY,Cho DK,Baik MH,Yoon KH

    更新日期:2018-11-01 00:00:00

  • A family of statistical distributions for modelling occupational radiation doses in low dose occupations.

    abstract::New statistical distributions have been defined to describe occupational exposures to ionising radiation. These distributions are particularly useful in modelling occupations where most doses are low. The maximum likelihood method was used for parameter estimation and has been adapted to allow doses that are recorded ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl045

    authors: Sont WN

    更新日期:2006-01-01 00:00:00

  • Assessment of natural radioactivity and the associated hazards in Iranian cement.

    abstract::This paper presents the finding of a study undertaken to determine natural radioactivity and associated hazards in local types of cement in Iran. A total of 42 samples were collected from various manufacturers and suppliers and analysed using a shielded HPGe gamma-ray spectrometer. The specific activities of 232Th, 22...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl549

    authors: Fathivand AA,Amidi J

    更新日期:2007-01-01 00:00:00

  • Analysis and improvement of cyclotron thallium target room shield.

    abstract::Because of high neutron and gamma-ray intensities generated during bombardment of a thallium-203 target, a thallium target-room shield and different ways of improving it have been investigated. Leakage of neutron and gamma ray dose rates at various points behind the shield are calculated by simulating the transport of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn099

    authors: Hajiloo N,Raisali G,Aslani G

    更新日期:2008-01-01 00:00:00

  • The genetics of radiation-induced osteosarcoma.

    abstract::Individual genetic variation can influence susceptibility to the carcinogenic effects of many environmental carcinogens. In radiation-exposed populations those individuals with a greater genetically determined susceptibility would be at greater risk of developing cancer. To include this modification of risk into radia...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006778

    authors: Rosemann M,Kuosaite V,Nathrath M,Atkinson MJ

    更新日期:2002-01-01 00:00:00

  • THE CONVERSION OF EXPOSURES DUE TO RADON INTO THE EFFECTIVE DOSE TAKING INTO ACCOUNT THE EQUIVALENCE OF RISKS FROM SHORT- AND LONG-TERM EXPOSURES.

    abstract::The theoretical basis for comparing risks from short- and long-term exposures is developed aiming at implementing long-term exposures into a unique and consistent system of radiation protection. Based on system-analytical considerations, the equivalence of population-averaged risk rates due to prolonged exposures and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv553

    authors: Beck TR

    更新日期:2016-12-01 00:00:00

  • TOWARDS A PERSONALISED AND INTERACTIVE ASSESSMENT OF OCCUPATIONAL EXPOSURE TO MAGNETIC FIELD DURING DAILY ROUTINE IN MAGNETIC RESONANCE.

    abstract::Magnetic resonance imaging (MRI) is one of the most common sources of electromagnetic (EM) fields as a diagnostic technique widely used in medicine. MRI staff during the working day is constantly exposed to static and spatially heterogeneous magnetic field. Also, moving around the MRI room to perform their functions, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy114

    authors: Hartwig V,Virgili G,Ferrante Vero LF,De Marchi D,Landini L,Giovannetti G

    更新日期:2018-12-01 00:00:00

  • Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy.

    abstract::On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of (131)I. Radiation doses for the designated caregivers were ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl084

    authors: Marriott CJ,Webber CE,Gulenchyn KY

    更新日期:2007-01-01 00:00:00

  • MICRODOSIMETRIC SIMULATIONS OF CARBON IONS USING THE MONTE CARLO CODE FLUKA.

    abstract::Therapeutic carbon ion beams produce a complex and variable radiation field that changes along the penetration depth due to the high density of energy loss along the particle track together with the secondary particles produced by nuclear fragmentation reactions. An accurate physical characterisation of such complex m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx201

    authors: Chiriotti S,Conte V,Colautti P,Selva A,Mairani A

    更新日期:2018-08-01 00:00:00

  • Practical application of the ICRP Human Respiratory Tract Model.

    abstract::The ICRP Publication 66 Human Respiratory Tract Model (HRTM) has been applied to calculate dose coefficients and bioassay functions using default values of parameters relating to the material and the subjects. The ICRP Task Group on Internal Dosimetry (INDOS) has developed a guidance document on application of the HRT...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006324

    authors: Bailey MR,Ansoborlo E,Guilmette RA,Paquet F

    更新日期:2003-01-01 00:00:00

  • A follow-up study on indoor 222Rn, 220Rn their decay product concentrations in a mineralised zone of Himachal Pradesh, India.

    abstract::A follow-up study was taken up in a mineralised zone situated in Hamirpur district, Himachal Pradesh, India, to investigate high values of radon concentrations reported in past studies as well to update the old radon data based on bare SSNTD technique. In the present investigation, the concentrations of indoor radon, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv367

    authors: Bajwa BS,Singh P,Singh P,Saini K,Singh S,Sahoo BK,Sapra BK

    更新日期:2016-03-01 00:00:00

  • Using simple mathematical functions to simulate pathological structures--input for digital mammography clinical trial.

    abstract::In this study a set of structures has been simulated to represent a range of clinically relevant breast cancer mammographic lesions including solid tumours and microcalcifications. All structures have been created using simple random-based mathematical functions and have been inserted into a subset of digital mammogra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch552

    authors: Ruschin M,Tingberg A,Båth M,Grahn A,Håkansson M,Hemdal B,Andersson I

    更新日期:2005-01-01 00:00:00

  • A recoil-proton spectrometer based on a p-i-n diode implementing pulse-shape discrimination.

    abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch237

    authors: Agosteo S,D'Angelo G,Fazzi A,Foglio Para A,Pola A,Ventura L,Zotto P

    更新日期:2004-01-01 00:00:00

  • Investigation of the neutron contribution in the 6 MeV to 7 MeV high energy photon reference field.

    abstract::In order to provide reference fields for the ionising radiation, PTB operates the ion accelerator facility. Referring to high energy photons, reference fields according to International Organization for Standardization 4037 series are produced. The neutron component of the 6-7 MeV photon field (R-F), which is produced...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp101

    authors: Röttger S,Heiske A,Nolte R

    更新日期:2009-07-01 00:00:00

  • Effective dose and breast dose reduction in paediatric scoliosis X-ray radiography by an optimal positioning.

    abstract::The purpose of this article is to recommend positioning to reduce the effective and breast-absorbed-doses in paediatric scoliosis radiography. Effective and breast-absorbed-doses were evaluated using Monte Carlo simulations. Head directed towards the anode (HTA) positioning rather than head directed towards the cathod...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/nct038

    authors: Ben-Shlomo A,Bartal G,Shabat S,Mosseri M

    更新日期:2013-01-01 00:00:00

  • Dosimetry of a set-up for the exposure of newborn mice to 2.45-GHZ WiFi frequencies.

    abstract::This work describes the dosimetry of a two waveguide cell system designed to expose newborn mice to electromagnetic fields associated with wireless fidelity signals in the frequency band of 2.45 GHz. The dosimetric characterisation of the exposure system was performed both numerically and experimentally. Specific meas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq129

    authors: Pinto R,Lopresto V,Galloni P,Marino C,Mancini S,Lodato R,Pioli C,Lovisolo GA

    更新日期:2010-08-01 00:00:00

  • LUMBAR SPINE RADIOGRAPHY: LOWER ORGAN DOSE WITH THE USE OF PA PROJECTION.

    abstract::The purpose of the research was to determine the effect of the posteroanterior (PA) patient position in lumbar spine imaging on effective dose and the absorbed organ dose. The study was performed on 100 patients that were referred to the lumbar spine radiography that were divided into two equal groups of 50. Body Mass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz057

    authors: Alukić E,Mekiš N

    更新日期:2019-12-31 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00