Recent results of irradiations of DIS-1 dosemeters with an XR200 X-ray flash unit.

Abstract:

:Earlier measurements have revealed that active electronic dosemeters have deficiencies in pulsed fields of ionising radiation due to the counting technique used. The DIS-1 dosemeter uses a promising technology, which should be basically suitable for measurements in pulsed fields. In this paper, first measurements with the DIS-1 dosemeter at an X-ray flash generator XR200 with pulse durations of ∼115 ns and doses per pulse of a few microsievert are shown.

journal_name

Radiat Prot Dosimetry

authors

Zutz H,Hupe O

doi

10.1093/rpd/ncs265

subject

Has Abstract

pub_date

2013-05-01 00:00:00

pages

401-4

issue

4

eissn

0144-8420

issn

1742-3406

pii

ncs265

journal_volume

154

pub_type

杂志文章
  • Type Testing of Model 7200 Automatic TLD Reader.

    abstract::The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminesce...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw100

    authors: Malek Mohammadi M,Hosseini Pooya SM

    更新日期:2017-04-20 00:00:00

  • OCCUPATIONAL EXPOSURE CHARACTERISTICS AND FACTORS ASSOCIATED WITH RADIATION DOSES AMONG KOREAN RADIATION WORKERS.

    abstract::This study identified occupational factors associated with radiation exposure in Korea. Survey data of 16 037 workers from 2016 to 2017, including lifestyle factors and occupational characteristics, were combined with the National Dose Registry. Higher average annual doses were observed in groups exhibiting health ris...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa019

    authors: Kim J,Seo S,Lee DN,Park S,Im KJ,Park S,Jin YW

    更新日期:2020-07-07 00:00:00

  • The efficiency of various thermoluminescence dosemeter types to heavy ions.

    abstract::Dose verification in heavy-ion beams using passive dosemeter systems, e.g. thermoluminescence dosemeters (TLDs), is crucial due to the changing efficiency of the dosemeters for different ion species and linear energy transfer (LET) values. This behaviour leads to a falsification of absorbed dose that can be significan...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci582

    authors: Berger T,Hajek M,Summerer L,Fugger M,Vana N

    更新日期:2006-01-01 00:00:00

  • Evaluation of occupational exposure to naturally occurring radioactive materials in the Iranian ceramics industry.

    abstract::Zircon contains small amounts of uranium, thorium and radium in its crystalline structure. The ceramic industry is one of the major consumers of zirconium compounds that are used as an ingredient at ∼10-20 % by weight in glaze. In this study, seven different ceramic factories have been investigated regarding the prese...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq441

    authors: Fathabadi N,Farahani MV,Amani S,Moradi M,Haddadi B

    更新日期:2011-06-01 00:00:00

  • Independent regulatory examination of radiation situation in the areas of spent nuclear fuel and radioactive wastes storage in the Russian far east.

    abstract::This paper describes the findings of the radiation situation analysis on-site near Sysoeva and Razbojnik Bays. The results of radiation monitoring performed by radiological laboratory of DalRAO and studies performed by the experts from the Burnasyan Federal Medical Biophysical Centre have been used in the course of an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr135

    authors: Shandala NK,Kiselev SM,Lucyanec AI,Titov AV,Seregin VA,Isaev DV,Akhromeev SV

    更新日期:2011-07-01 00:00:00

  • Further progress in the characterisation of complex radiation fields.

    abstract::One of the topics which forms part of CONRAD project addresses the problems related to the dosimetry of complex-mixed radiation fields at workplaces. This topic was included in work package (WP) 6. WP 6 was established to co-ordinate research activities in two areas:the development of new techniques and the improvemen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn220

    authors: Spurny F,Silari M

    更新日期:2008-01-01 00:00:00

  • W values of protons in liquid water.

    abstract::The W values of protons in liquid water were calculated for energies from 0.1 keV to 10 MeV using the continuous slowing down approximation as well as three models for the calculation of the differential ionisation cross-sections of water for protons published in recent years. The W values determined by means of the t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm019

    authors: Baek WY,Grosswendt B

    更新日期:2007-01-01 00:00:00

  • Relative radiological risks derived from different TENORM wastes in Malaysia.

    abstract::In Malaysia technologically enhanced naturally occurring radioactive materials (TENORM) wastes are mainly the product of the oil and gas industry and mineral processing. Among these TENORM wastes are tin tailing, tin slag, gypsum and oil sludge. Mineral processing and oil and gas industries produce large volume of TEN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq577

    authors: Ismail B,Teng IL,Muhammad Samudi Y

    更新日期:2011-11-01 00:00:00

  • Screen-film versus digital radiography of sacroiliac joints: evaluation of image quality and dose to patients.

    abstract::The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film rad...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs315

    authors: Jablanovic D,Ciraj-Bjelac O,Damjanov N,Seric S,Radak-Perovic M,Arandjic D,Maksimovic R

    更新日期:2013-06-01 00:00:00

  • Variations in radon concentration in groundwater of Kumaon Himalaya, India.

    abstract::The radon content in groundwater sources depends on the radium concentration in the rock of the aquifer. Radon was measured in water in many parts of the world, mostly for the risk assessment due to consumption of drinking water. The exposure to radon through drinking water is largely by inhalation and ingestion. Airb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs186

    authors: Bourai AA,Gusain GS,Rautela BS,Joshi V,Prasad G,Ramola RC

    更新日期:2012-11-01 00:00:00

  • ISFSI site boundary radiation dose rate analyses.

    abstract::Across the globe nuclear utilities are in the process of designing and analysing Independent Spent Fuel Storage Installations (ISFSI) for the purpose of above ground spent-fuel storage primarily to mitigate the filling of spent-fuel pools. Using a conjoining of discrete ordinates transport theory (DORT) and Monte Carl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci279

    authors: Hagler RJ,Fero AH

    更新日期:2005-01-01 00:00:00

  • MEASUREMENT OF THE POTENTIAL ALPHA ENERGY CONCENTRATION OF RADON PROGENY BY USING LIQUID SCINTILLATION COUNTING METHOD.

    abstract::For more accurate measurement of the potential alpha energy concentration (PAEC) of radon progeny by the liquid scintillation counting (LSC) method, its counting efficiency was studied in this work. A radon progeny standard source was used to provide different concentrations of radon progeny, and the progeny collected...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz069

    authors: Feng B,Tang Q,Zhang H,Chen B,Qiu S,Zhuo W

    更新日期:2019-10-01 00:00:00

  • Determination of personal dose equivalents in accelerator radiation fields.

    abstract::Values for the dose equivalent are required for radiation protection purposes, but determination of such values can be quite difficult for high energy radiations. The accurate determination of personal dose equivalents in accelerator radiation fields requires the propel use of appropriate radiological quantities and u...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006629

    authors: McDonald JC

    更新日期:2001-01-01 00:00:00

  • NATURAL RADIATION EXPOSURE TO THE PUBLIC IN MINING AND ORE BEARING REGIONS OF CAMEROON.

    abstract::Within the framework of a joint research project on natural radiation exposure and its health effects in Cameroon from 2014 to 2017, the Institute of Geological and Mining Research and the Hirosaki University worked together to carry out natural radiation survey in mining and ore bearing regions of Cameroon. Air kerma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz176

    authors: Tokonami S,Hosoda M,Joseph Emmanuel NNI,Akata N,Flore TSY,Modibo OB,Samuel BG,Didier TSS

    更新日期:2019-10-01 00:00:00

  • A new lead-free radiation shielding material for radiotherapy.

    abstract::Lead has recently been recognised as a source of environmental pollution, including the lead used for radiation shielding in radiotherapy. The bremsstrahlung radiation caused by the interaction between the electron beam and lead may reduce the accuracy of radiotherapy. To avoid the use of lead, a new material composed...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp053

    authors: Yue K,Luo W,Dong X,Wang C,Wu G,Jiang M,Zha Y

    更新日期:2009-02-01 00:00:00

  • Development of a voxel phantom of Japanese adult male in upright posture.

    abstract::A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm272

    authors: Sato K,Noguchi H,Endo A,Emoto Y,Koga S,Saito K

    更新日期:2007-01-01 00:00:00

  • 238U CONTENT IN URINE OF URANIUM MINERS AND ITS MODELED VALUES.

    abstract::The aim of the study is to make a comparison of daily 238U excretion in urine among 115 active uranium miners and its modeled values obtained from inhalation intake of long-lived alpha emitters as measured by personal dosemeters and assessed by biokinetic models for different absorption parameters settings for inhaled...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx061

    authors: Kotík L,Becková V,Malátová I,Tomasek L

    更新日期:2017-12-01 00:00:00

  • Development of a radon trap device using a corona discharge.

    abstract::Radon is one of the noble gases, which are chemically inert and do not make any reactants under normal conditions. In this experiment we demonstrated an enigmatic reaction between radon and fluorine when a corona discharge is used as a promoter. Distinctive changes in radon concentrations were caused by the discharge ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci311

    authors: Yamada Y,Koizumi A,Ishikawa K,Hishinuma Y,Tatenuma K

    更新日期:2005-01-01 00:00:00

  • RECOMMENDATIONS FOR MONITORING AND INTERNAL DOSIMETRY FOR NUCLEAR MEDICINE STAFF EXPOSED TO RADIOPHARMACEUTICALS 223Ra DICHLORIDE.

    abstract::223Ra is a radiopharmaceutical used as unsealed source in nuclear medicine. In the case of staff inhalation contamination of 223Ra, methods to estimate the committed effective dose should be chosen with care. Three methods are available: whole-body measurement and gamma spectrometry for urine or faeces samples. Consid...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy065

    authors: Saurat D,Aupée O,Gontier E,Métivier D,Cazoulat A,Lecompte Y

    更新日期:2018-12-01 00:00:00

  • A family of statistical distributions for modelling occupational radiation doses in low dose occupations.

    abstract::New statistical distributions have been defined to describe occupational exposures to ionising radiation. These distributions are particularly useful in modelling occupations where most doses are low. The maximum likelihood method was used for parameter estimation and has been adapted to allow doses that are recorded ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl045

    authors: Sont WN

    更新日期:2006-01-01 00:00:00

  • Implications of the space radiation environment for human exploration in deep space.

    abstract::Human exploration of the solar system beyond Earth's orbit will entail many risks for the crew on these deep space missions. One of the most significant health risks is exposure to the harsh space radiation environment beyond the protection provided by the Earth's intrinsic magnetic field. Crew on exploration missions...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci141

    authors: Townsend LW

    更新日期:2005-01-01 00:00:00

  • Improved chelation therapy of intramuscularly deposited thorium by CaDTPA in the rat.

    abstract::Comparative studies on the translocation and retention of intramuscularly (i.m.) injected thorium nitrate (234Th 46 ng + 232Th 5 microg per rat) in solutions of citrate, CaDTPA or citrate + CaDTPA in rats have been conducted. Results showed that only thorium in mixed-ligand solution was entirely translocated from the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006294

    authors: Rencová J,Vlková A,Veselá G

    更新日期:2003-01-01 00:00:00

  • Cytogenic investigations of serious overexposures to an industrial gamma radiography source.

    abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006090

    authors: Sevan'kaev AV,Lloyd DC,Edwards AA,Moquet JE,Nugis VY,Mikhailova GM,Potetnya OI,Khvostunov IK,Guskova AK,Baranov AE,Nadejina NM

    更新日期:2002-01-01 00:00:00

  • EMISSION OF SOIL GAS RADON CONCENTRATION AROUND MAIN CENTRAL THRUST IN UKHIMATH (RUDRAPRAYAG) REGION OF GARHWAL HIMALAYA.

    abstract::In this paper, the result of systematic measurement of the soil gas radon concentrations is discussed and the background values are defined along and around the Main Central Thrust (MCT) in Ukhimath region of Garhwal Himalaya, India. The Ukhimath region is being subjected to intense neotectonic activities like earthqu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw067

    authors: Aswal S,Kandari T,Sahoo BK,Bourai AA,Ramola RC

    更新日期:2016-10-01 00:00:00

  • BAYESIAN SPECTRUM DECONVOLUTION INCLUDING UNCERTAINTIES AND MODEL SELECTION: APPLICATION TO X-RAY EMISSION DATA USING WINBUGS.

    abstract::Spectrum deconvolution is an important task in ionizing radiation measurements, as the pulse height spectra, or, in general, the measured data from spectrometers or other measuring instruments are usually determined by the convolution of the response function with the fluence spectra. The method presented here for obt...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy286

    authors: Behrens R,Reginatto M

    更新日期:2019-12-23 00:00:00

  • Skin dose measurements using radiochromic films, TLDS and ionisation chamber and comparison with Monte Carlo simulation.

    abstract::Estimation of the surface dose is very important for patients undergoing radiation therapy. The purpose of this study is to investigate the dose at the surface of a water phantom at a depth of 0.007 cm as recommended by the International Commission on Radiological Protection and International Commission on Radiation U...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct315

    authors: Alashrah S,Kandaiya S,Maalej N,El-Taher A

    更新日期:2014-12-01 00:00:00

  • NEURAL NETWORK MODELLING OF CARDIAC DOSE CONVERSION COEFFICIENT FOR ARBITRARY X-RAY SPECTRA.

    abstract::In this article, an approach to compute the dose conversion coefficients (DCCs) is described for the computational voxel phantom 'High-Definition Reference Korean-Man' (HDRK-Man) using artificial neural networks (ANN). For this purpose, the voxel phantom was implemented into the Monte Carlo (MC) transport toolkit GEAN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv436

    authors: Kadri O,Manai K

    更新日期:2016-12-01 00:00:00

  • Development of a retrospective/fortuitous accident dosimetry service based on OSL of mobile phones.

    abstract::Work is presented on the development of a retrospective/fortuitous accident dosimetry service using optically stimulated luminescence of resistors found in mobile phones to determine the doses of radiation to members of the public following a radiological accident or terrorist incident. The system is described and dis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu370

    authors: Smith RW,Eakins JS,Hager LG,Rothkamm K,Tanner RJ

    更新日期:2015-04-01 00:00:00

  • BYSTANDER WI-38 CELLS MODULATE DNA DOUBLE-STRAND BREAK REPAIR IN MICROBEAM-TARGETED A549 CELLS THROUGH GAP JUNCTION INTERCELLULAR COMMUNICATION.

    abstract::Bi-directional signaling involved in radiation-induced bystander effect (RIBE) between irradiated carcinoma cells and their surrounding non-irradiated normal cells is relevant to radiation cancer therapy. Using the SPICE-NIRS microbeam, we delivered 500 protons to A549-GFP lung carcinoma cells, stably expressing H2B-G...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy249

    authors: Kobayashi A,Autsavapromporn N,Ahmad TAFT,Oikawa M,Homma-Takeda S,Furusawa Y,Wang J,Konishi T

    更新日期:2019-05-01 00:00:00

  • Narrow beam dosimetry for high energy hadrons and electrons.

    abstract::Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10-400 GeV. The target organs considered were right eye, thyroid,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006556

    authors: Pelliccioni M,Silari M,Ulrici L

    更新日期:2001-01-01 00:00:00