Narrow beam dosimetry for high energy hadrons and electrons.

Abstract:

:Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10-400 GeV. The target organs considered were right eye, thyroid, thymus, lung and breast. Simple scaling laws to the calculated values are given. The present data and formulae should prove useful for dosimetric estimations in the case of accidental exposures to high energy beams.

journal_name

Radiat Prot Dosimetry

authors

Pelliccioni M,Silari M,Ulrici L

doi

10.1093/oxfordjournals.rpd.a006556

keywords:

subject

Has Abstract

pub_date

2001-01-01 00:00:00

pages

323-32

issue

4

eissn

0144-8420

issn

1742-3406

journal_volume

95

pub_type

杂志文章
  • Radioactivity and dose assessment of marble samples from Igbeti mines, Nigeria.

    abstract::The concentration and distribution of natural radionuclides in marble around Igbeti marble mines, Nigeria, were measured to evaluate the environmental radioactivity and health effects which the marble samples may posses. The concentration of radionuclides was determined using gamma-ray spectrometry with NaI (Tl) detec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn279

    authors: Ademola AK,Hammed OS,Adejumobi CA

    更新日期:2008-01-01 00:00:00

  • Natural radioactivity intake into wheat grown on fertilized farms in two districts of Pakistan.

    abstract::The use of phosphate fertilizers on agricultural farms enhances gamma-ray activity concentration in the farms and therefore absorbed dose rates to the public. The most common natural radionuclides in fertilizer and soil are (40)K, (226)Ra and (232)Th. Agricultural farms at four locations in two districts in Pakistan c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl100

    authors: Nasim-Akhtar,Tufail M

    更新日期:2007-01-01 00:00:00

  • Dosimetric data and radiation risk analysis for new procedures in interventional cardiology.

    abstract::The purpose of this study was to evaluate radiation doses to the patients and operators during interventional cardiology procedures, with a particular focus on the transcatheter aortic valve implantation (TAVI). Patient doses for 5549 diagnostic and therapeutic procedures and 76 TAVI were examined, as well as occupati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq208

    authors: Signorotto P,del Vecchio A,Montorfano M,Maisano F,Giagnorio M,Bellanca R,Colombo A,Calandrino R

    更新日期:2010-12-01 00:00:00

  • The role of retrapping in dose dependence of pulsed optically stimulated luminescence.

    abstract::Superlinear behaviour has been observed in dose dependence measurements of optically stimulated luminescence (OSL). Previous theoretical work has shown that superlinearity of the integral under the OSL decay curve may occur, resulting from competition with either radiationless luminescence centres or disconnected trap...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005938

    authors: Chen R

    更新日期:2002-01-01 00:00:00

  • New data on direct ion storage dosemeters.

    abstract::The DIS-1 dosemeter from the Finnish company RADOS is an innovative kind of passive electronic dosemeter for photon and beta radiation. This study examines the 'long-term' linear response behaviour, the calibration and readout accuracy with large samples of 'used' DIS-1 dosemeters especially in the low-dose region, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm240

    authors: Fuchs H,Stähler S,Dittmar M

    更新日期:2008-01-01 00:00:00

  • CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II.

    abstract::Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx236

    authors: Harrison J,Moreno B,Van Hoey O,Mihailescu LC,Vanhavere F,Million M,Fomenko V,Akselrod M

    更新日期:2018-08-01 00:00:00

  • The shielding design process--new plants to decommissioning.

    abstract::BNFL have over 25 years experience of designing nuclear plant for the whole-fuel cycle. In the UK, a Nuclear Decommissioning Authority (NDA) is to be set up to ensure that Britain's nuclear legacy is cleaned up safely, securely and cost effectively. The resulting challenges and opportunities for shielding design will ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nci171

    authors: Jeffries G,Cooper A,Hobson J

    更新日期:2005-01-01 00:00:00

  • Radon concentrations in three underground lignite mines in Turkey.

    abstract::Monitoring of radon in underground mines is important in order to assess the radiological hazards to occupational workers. Radon concentration levels in three underground lignite mines (Tunçbilek, Omerler and Eynez) of Turkey were obtained in this study. For this reason, atmospheric radon level measurements were carri...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp179

    authors: Cile S,Altinsoy N,Celebi N

    更新日期:2010-01-01 00:00:00

  • Development of lung and soft tissue substitutes for photons.

    abstract::The use of solid tissue substitutes is a well-accepted and common practice in dosimetric studies and in the production of counting standards for radiological protection. However, only a few solid tissue substitutes simulating a particular body tissue with respect to a set of physical characteristics are commercially a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci018

    authors: Kinase S,Kimura M,Noguchi H,Yokoyama S

    更新日期:2005-01-01 00:00:00

  • Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments.

    abstract::High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with (252)Cf neutron sources and are used in various wor...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu298

    authors: Lee KW,Sheu RJ

    更新日期:2015-04-01 00:00:00

  • Radon in the Exhaled Air of Patients in Radon Therapy.

    abstract::In the Gastein valley, numerous facilities use radon for the treatment of various diseases either by exposure to radon in air or in radon rich thermal water. In this study, six test persons were exposed to radon thermal water in a bathtub and the time-dependent radon activity concentration in the exhaled air was recor...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx153

    authors: Lettner H,Hubmer A,Hofmann W,Landrichinger J,Gaisberger M,Winkler-Heil R

    更新日期:2017-11-01 00:00:00

  • Filter, collimator and moderating material to achieve boron neutron capture enhanced fast neutron therapy.

    abstract::The combination of fast neutron therapy and boron neutron capture therapy is currently being studied as a possible treatment for some radio-resistant brain tumours. In an attempt to design a boron-enhanced fast neutron therapy beam for the Fermilab Fast Neutron Therapy Facility, the use of moderating material surround...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci256

    authors: Sweezy J,Hertel N,Lennox A

    更新日期:2005-01-01 00:00:00

  • Quality control of micro-computed tomography systems.

    abstract::The rapid proliferation of micro-computed tomography (micro-CT) scanners in preclinical small animal studies has created a need for a method on scanner performance evaluation and scan parameter optimisation. The purpose of this study was to investigate the performance of the scanner with a dedicated micro-CT phantom. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq088

    authors: Eloot L,Buls N,Covens P,Willekens I,Lahoutte T,de Mey J

    更新日期:2010-04-01 00:00:00

  • Results of field trials using the NPL simulated reactor neutron field facility.

    abstract::The NPL simulated reactor neutron field facility provides neutron spectra similar to those found in the environs of UK gas-cooled reactors. Neutrons are generated by irradiating a thick lithium-alloy target with monoenergetic protons between 2.5 and 3.5 MeV (depending on the desired spectrum), and then moderated by a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm018

    authors: Taylor GC,Thomas DJ,Bennett A

    更新日期:2007-01-01 00:00:00

  • Measurements of environmental background radiation at location of coal-fired power plants.

    abstract::Environmental radiation monitoring in the vicinity of coal-fired power plants which are used primarily to determine the variability in measured background exposures are presented in this article; this is in order to estimate the contribution due to the plants' operation. Measurements have been done using a multi-eleme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch401

    authors: Adrovic F,Prokić M,Ninković MM,Glisić R

    更新日期:2004-01-01 00:00:00

  • NATURAL RADIONUCLIDES IN AGRICULTURAL PLANTS FROM NORTHERN THAILAND.

    abstract::Thailand is predominantly an agricultural country. The Northern Region occupies the second largest cultivated land area in the country. To establish baseline data for future environmental monitoring, seventy-nine plant samples including vegetables, fruits and tobaccos and their relevant soils were collected from the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz081

    authors: Kritsananuwat R,Kranrod C,Chanyotha S,Ploykrathok T,Sriploy P

    更新日期:2019-10-01 00:00:00

  • ORGANIC SCINTILLATOR FOR REAL-TIME NEUTRON DOSIMETRY.

    abstract::We developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept mea...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx255

    authors: Beyer KA,Di Fulvio A,Stolarczyk L,Parol W,Mojzeszek N,Kopéc R,Clarke SD,Pozzi SA

    更新日期:2018-08-01 00:00:00

  • Neutron calibration facility with radioactive neutron sources at KRISS.

    abstract::For the purpose of radiation protection, the reference neutron field for calibration of neutron monitors was constructed using radioactive neutron sources-bare-(252)Cf, D(2)O-moderated (252)Cf and (241)Am-Be(alpha,n)-at Korea Research Institute of Standards and Science (KRISS). The well-specified neutron source with i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm034

    authors: Park H,Kim J,Choi KO

    更新日期:2007-01-01 00:00:00

  • Population dose due to building materials in Ibadan, Nigeria.

    abstract::The natural radionuclide contents of some concrete building blocks randomly sampled in the city of Ibadan have been determined using NaI(Tl) gamma ray spectrometry. The radionuclides 226Ra, 232Th and 40K were determined with city mean specific activities 47 +/- 21 Bq.kg-1, 52 +/- 21 Bq.kg-1, and 352 +/- 222 Bq.kg-1, r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006527

    authors: Farai IP,Ademola JA

    更新日期:2001-01-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • Modelling the 137Cs ingestion dose from consumption of marine fish in Hong Kong.

    abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006710

    authors: Poon CB,Au SM

    更新日期:2002-01-01 00:00:00

  • CT equipment and performance issues: radiation protection 162.

    abstract::Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in pa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs285

    authors: Edyvean S

    更新日期:2013-02-01 00:00:00

  • A family of statistical distributions for modelling occupational radiation doses in low dose occupations.

    abstract::New statistical distributions have been defined to describe occupational exposures to ionising radiation. These distributions are particularly useful in modelling occupations where most doses are low. The maximum likelihood method was used for parameter estimation and has been adapted to allow doses that are recorded ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl045

    authors: Sont WN

    更新日期:2006-01-01 00:00:00

  • Optimised geometry to calculate dose rate conversion coefficient for external exposure to photons.

    abstract::A single-parameter geometry to describe soil is achieved for Monte Carlo calculation of absorbed dose rate in air for photon emitters from natural radionuclides. This optimised geometry based on physical assumptions consists of the soil part whose emitted radiation has a given minimum probability to reach the detector...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm426

    authors: Askri B,Manai K,Trabelsi A,Baccari B

    更新日期:2008-01-01 00:00:00

  • Single-aliquot EPR dosimetry of wallboard (drywall).

    abstract::Electron paramagnetic resonance spectra and dose-response curves are presented for a variety of wallboard samples obtained from different manufacturing facilities, as well as for source gypsum and anhydrite. The intensity of the CO(3)(-) paramagnetic centre (G2) is enhanced with gamma radiation. Isothermal decay curve...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq581

    authors: Mistry R,Thompson JW,Boreham DR,Rink WJ

    更新日期:2011-11-01 00:00:00

  • Method of thermoluminescent measurement of radiation doses from micrograys up to a megagray with a single LiF:Mg,Cu,P detector.

    abstract::On the basis of the newly discovered behaviour of LiF:Mg,Cu,P detectors at high and ultra-high doses, a new method of thermoluminescence (TL) measurement of radiation doses ranging from micrograys up to a megagray, has been recently developed at the Institute of Nuclear Physics (IFJ). The method is based on the relati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq339

    authors: Obryk B,Bilski P,Olko P

    更新日期:2011-03-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00

  • Assessment of natural radioactivity concentrations and gamma dose rate levels in Kayseri, Turkey.

    abstract::This study assesses the level of background radiation for Kayseri province of Turkey. Natural radionuclide activity concentrations in soil samples were determined using high-resolution gamma spectroscopy. Outdoor gamma dose measurements in air at 1 m above ground level were determined using a portable gamma scintillat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr023

    authors: Otansev P,Karahan G,Kam E,Barut I,Taskin H

    更新日期:2012-01-01 00:00:00

  • A survey of patient dose and clinical factors in a full-field digital mammography system.

    abstract::In this work, we analyse the dose to 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography (FFDM) system over a 2-y period. The information relevant to this study has been extracted from the image Digital Imaging and Communications in Medicine (DICOM) headers. Entr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch514

    authors: Morán P,Chevalier M,Ten JI,Fernández Soto JM,Vañó E

    更新日期:2005-01-01 00:00:00

  • OCCUPATIONAL EXPOSURE TO RADON IN DIFFERENT KINDS OF NON-URANIUM MINES.

    abstract::For more accurate assessments of the occupational exposure to radon for miners, the individual monitoring was conducted by using an improved passive integrating (222)Rn monitor. A total of 120 miners in 3 different kinds of mines were monitored throughout a year. The results showed that the individual exposure to rado...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw026

    authors: Fan D,Zhuo W,Zhang Y

    更新日期:2016-09-01 00:00:00