Survey of patient dose in computed tomography in Syria 2009.

Abstract:

:The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the International Atomic Energy Agency in different regions of the world covering Asia, Africa and Eastern Europe. The dose quantities covered are CT dose index (CTDI(w)), dose-length product (DLP), effective dose (E) and collective dose. It was found that most CTDI(w) and DLP values were similar to the European reference levels and in line with the results of similar surveys in the world. The results were in good agreement with the UNSCEAR Report 2007. This study concluded a recommendation for national diagnostic reference level for the most common CT protocols in Syria. The results can be used as a base for future optimisation studies in the country.

journal_name

Radiat Prot Dosimetry

authors

Kharita MH,Khazzam S

doi

10.1093/rpd/ncq155

subject

Has Abstract

pub_date

2010-09-01 00:00:00

pages

149-61

issue

2

eissn

0144-8420

issn

1742-3406

pii

ncq155

journal_volume

141

pub_type

杂志文章
  • Novel developments in the MOSFET dosemeter for neutron dosimetry applications.

    abstract::The feasibility of large-geometry Metal Oxide Semiconductor Field Effect Transistor (MOSFET) devices has been assessed for both active and passive neutron dosimetry and use in radiotherapy environments. Neutron sensitivity has been enhanced with the use of polymeric cement surrounding the gate region. Neutron activati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch202

    authors: Price RA,Benson C,Joyce MJ,Kestell DJ,Silvie J

    更新日期:2004-01-01 00:00:00

  • INFLUENCE OF STATIC ELECTRICITY ON RADON MEASUREMENT USING PASSIVE DETECTORS.

    abstract::In order to investigate the influence of the static electricity on the measurement using passive radon detector, detectors were charged at the surface of chamber and its CR-39 elements respectively on purpose before the exposure in this study. The results of in-chamber experiments revealed that the static electricity ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz067

    authors: Chen B,Zhao C,Fan D,Zhuo W

    更新日期:2019-10-01 00:00:00

  • Radon concentration measurements in bituminous coal mines.

    abstract::Radon measurements were carried out in Kozlu, Karadon and Uzülmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch449

    authors: Fisne A,Okten G,Celebi N

    更新日期:2005-01-01 00:00:00

  • Thermoluminescence dosimetric characteristics of beta irradiated salt.

    abstract::The thermoluminescence (TL) characteristics of sodium chloride (NaCl), known as common salt, used for cooking purposes (iodised salt), have been studied in the present paper considering its usage as an 'accidental dosemeter' in the case of a nuclear fallout. TL characteristics of common salt have been examined under e...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci568

    authors: Murthy KV,Pallavi SP,Rahul G,Patel YS,Sai Prasad AS,Elangovan D

    更新日期:2006-01-01 00:00:00

  • INTERCAL: long-term inter-comparison experiment for dose rate and spectrometric probes.

    abstract::The Schauinsland inter-calibration facility (INTERCAL) has been designed to enable long-term comparison experiments for 20 different dose rate probes from different networks. Two reference probes characterised by the European Radiation Dosimetry WG3 inter-calibration experiments in 2008 and 2009 have been installed at...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu039

    authors: Bleher M,Doll H,Harms W,Stöhlker U

    更新日期:2014-08-01 00:00:00

  • Managing Internal Radiation Contamination Following an Emergency: Identification of Gaps and Priorities.

    abstract::Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw199

    authors: Li C,Ansari A,Etherington G,Jourdain JR,Kukhta B,Kurihara O,Lopez MA,Ménétrier F,Alves Dos Reis A,Solomon S,Zhang J,Carr Z

    更新日期:2016-09-01 00:00:00

  • Radiation effects in cultured tumour cells examined by 1H MRS: mobile lipids modulation and proliferative arrest.

    abstract::Much attention has been devoted in the past to monitor changes of mobile lipid (ML) (1)H MRS signals in spectra of tumour cells. The purpose of this work is to exploit ML signals to provide information on cell metabolism after irradiation, comparing tumour cells characterised by different radiosensitivity and relating...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl517

    authors: Grande S,Giovannini C,Luciani AM,Palma A,Rosi A,Sapora O,Viti V,Guidoni L

    更新日期:2006-01-01 00:00:00

  • Natural radioactivity study in soil samples of South Konkan, Maharashtra, India.

    abstract::This study assesses the level of natural radioactivity due to radionuclides, ²³⁸U, ²³²Th and ⁴⁰K, in 50 soil samples collected from South Konkan, Maharashtra, India. The mean activity concentrations of ²³⁸U, ²³²Th and ⁴⁰K are 44.97 ± 1.22 Bq kg⁻¹, 59.70 ± 2.17 Bq kg⁻¹ and 217.51 ± 8.75 Bq kg⁻¹, respectively, measured ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct131

    authors: Dhawal SJ,Phadatare MR,Thorat ND,Kulkarni GS,Pawar SH

    更新日期:2013-12-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • BASELINE STUDIES ON RADIONUCLIDE CONCENTRATION IN FOOD MATERIALS AND ESTIMATION OF THE COMMITTED RADIATION DOSE AROUND THE PHOSPHATE INDUSTRIAL AREA OF SOUTH TUNISIA.

    abstract::The activity concentration of natural and anthropogenic radionuclides was determined in different vegetable samples, and foods derived from animal origin, from different locations in the four cities of Southern Tunisia, where large-scale phosphate industries are operating. The aim of the studies was to establish a bas...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy208

    authors: Machraoui S,Mohan MP,Naregundi K,Labidi S

    更新日期:2019-08-01 00:00:00

  • Practical application of the ICRP Human Respiratory Tract Model.

    abstract::The ICRP Publication 66 Human Respiratory Tract Model (HRTM) has been applied to calculate dose coefficients and bioassay functions using default values of parameters relating to the material and the subjects. The ICRP Task Group on Internal Dosimetry (INDOS) has developed a guidance document on application of the HRT...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006324

    authors: Bailey MR,Ansoborlo E,Guilmette RA,Paquet F

    更新日期:2003-01-01 00:00:00

  • THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): AN INTRODUCTION TO THE DOCUMENTATION.

    abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx020

    authors: Napier BA

    更新日期:2017-11-01 00:00:00

  • FEASIBILITY STUDY FOR IDENTIFICATION OF STATIC AND DYNAMIC EXPOSURE USING CCD IMAGING TECHNIQUE FOR Caso4:Dy TL DOSEMETERS.

    abstract::The occupational exposure incurred by the radiation workers due to the external radiation is estimated using personal dosemeter placed on the human body during the monitoring period. In certain situations, it is required to determine whether the dosemeter alone was exposed accidentally/intentionally in radiation field...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx011

    authors: Srivastava K,Soin S,Sapra BK,Ratna P,Datta D

    更新日期:2017-11-01 00:00:00

  • Characterization Of A Lanthanum Bromide Detector For Eye Lens Dosimetry At The Candu Nuclear Power Plants Based On Direct Measurements Of The Gamma-Ray Spectra.

    abstract::Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers' exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa186

    authors: Laranjeiro AS,Bohra F,Byun SH,Atanackovic J,Hanu AR

    更新日期:2020-12-15 00:00:00

  • Measured proton sensitivities of bubble detectors.

    abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch330

    authors: Takada M,Kitamura H,Koi T,Nakamura T,Fujitaka K

    更新日期:2004-01-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00

  • Supine linac treatment versus tomotherapy in craniospinal irradiation: planning comparison and dosimetric evaluation.

    abstract::Craniospinal irradiation (CSI) is the standard treatment of primary intracranial tumour with risk of leptomeningeal dissemination. However, supine setup field-in-field technique does not need inter-fractional junction shift. Recently, the studies of CSI with tomotherapy showed excellent target coverage and tolerable n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr190

    authors: Hong JY,Kim GW,Kim CU,Cheon GS,Son SH,Lee JY,Lee YH,Lee JH,Choi BO,Kim YS,Lee SN,Jang HS,Kang YN,Yoon SC

    更新日期:2011-07-01 00:00:00

  • Deformation luminescence produced during application and release of pressure on to gamma-irradiated CaF2:RE crystals.

    abstract::Calcium fluoride CaF2 is an interesting host lattice for rare earth (RE) activators. CaF2 crystals doped with different concentrations of Dy, Ce, Er and Gd have been grown by the Bridgman technique and their deformation luminescence (DL) induced by room temperature gamma irradiation has been recorded. When a uniaxial ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci606

    authors: Kher RS,Brahme N,Banerjee M,Dhoble SJ,Khokhar MS

    更新日期:2006-01-01 00:00:00

  • Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032854

    authors: Vana N,Schoner W,Noll M,Fugger M,Akatov Y,Shurshakov V

    更新日期:1999-01-01 00:00:00

  • International intercomparison of measuring instruments for radon/thoron gas and radon short-lived daughter products in the NRPI Prague.

    abstract::During the 7th European Conference on Protection Against Radon at Home and at Work held in the autumn of 2013 in Prague, the second intercomparison of measuring instruments for radon and its short-lived decay products and the first intercomparison of radon/thoron gas discriminative passive detectors in mix field of ra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu079

    authors: Jílek K,Hýža M,Kotík L,Thomas J,Tomášek L

    更新日期:2014-07-01 00:00:00

  • IMPROVEMENT OF GAMMA-RAY SUBTRACTION PROCEDURE FOR A CURRENT-MODE NEUTRON DETECTOR WITH A PAIR OF 6Li- AND 7Li-GLASS SCINTILLATORS.

    abstract::A current-mode neutron detector with a pair of 6Li- and 7Li-glass scintillators has been developed to measure high-flux neutrons in a boron neutron capture therapy field. Neutrons are basically measured by subtracting gamma-ray component using current outputs from the 7Li-glass scintillator. In the present study, the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz266

    authors: Matsumoto T,Masuda A,Harano H,Hori JI,Sano T

    更新日期:2020-06-12 00:00:00

  • Radiation-induced non-targeted effects: some open questions.

    abstract::The existence of non-targeted effects (NTEs) of radiation (genomic instability and bystander effects) has been generally accepted for >20 y; however, there is research, which was largely ignored going back to 1915 reporting these effects. Despite today's general acceptance of the phenomenon of NTE, there is little agr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncv155

    authors: Mothersill C,Seymour C

    更新日期:2015-09-01 00:00:00

  • Determination of the dose to persons assisting when X-radiation is used in medicine, dentistry and veterinary medicine.

    abstract::During medical X-ray examinations of patients, humans as well as animals, voluntarily assisting persons are frequently needed in order to calm down the patient or animal. Typical exposure situations have been identified and measurements were performed in the fields of scattered X-rays. The personal dose equivalent H(p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq351

    authors: Hupe O,Ankerhold U

    更新日期:2011-03-01 00:00:00

  • Aircraft crew radiation workplaces: comparison of measured and calculated ambient dose equivalent rate data using the EURADOS in-flight radiation data base.

    abstract::In May 2000, the chairman of the European Radiation Dosimetry Group (EURADOS) invited a number of experts with experience of cosmic radiation dosimetry to form a working group (WG 5) on aircraft crew dosimetry. Three observers from the Article 31 Group of Experts as well as one observer from the Joint Aviation Authori...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl029

    authors: Beck P,Bartlett D,Lindborg L,McAulay I,Schnuer K,Schraube H,Spurny F

    更新日期:2006-01-01 00:00:00

  • Biomarkers specific to densely-ionising (high LET) radiations.

    abstract::There have been several suggestions of biomarkers that are specific to high LET radiation. Such a biomarker could significantly increase the power of epidemiological studies of individuals exposed to densely-ionising radiations such as alpha particles (e.g. radon, plutonium workers, individuals exposed to depleted ura...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006640

    authors: Brenner DJ,Okladnikova N,Hande P,Burak L,Geard CR,Azizova T

    更新日期:2001-01-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA.

    abstract::New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (Op...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv430

    authors: Örtenberg A,Magnusson M,Sandborg M,Alm Carlsson G,Malusek A

    更新日期:2016-06-01 00:00:00

  • Local diagnostic reference levels in standard X-ray examinations.

    abstract::The national diagnostic reference levels (NDRLs) form an efficient, concise and powerful standard for optimising radiation protection of a patient. However, in a large hospital, where many radiological departments are present, it is also possible to calculate and define lower dose values as local diagnostic reference ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch432

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • EFFECT OF PATIENT SIZE, ANATOMICAL LOCATION AND MODULATION STRENGTH ON DOSE DELIVERED AND IMAGE-QUALITY ON CT EXAMINATION.

    abstract::To study the effect of patient size, anatomical location and modulation strength (MS) on image-quality and delivered dose of CT scans acquired with automatic-exposure-control system (AEC). Four anthropomorphic phantoms (three paediatric and one thin adult) were studied, and normal and obese adults were simulated by pl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx055

    authors: Greffier J,Larbi A,Macri F,Beregi JP,Pereira F

    更新日期:2017-12-01 00:00:00

  • Occurrence and Dose From Intake of Radon In Drinking Groundwater In Ogun State, Nigeria.

    abstract::Radon-222 concentrations in groundwater from 10 local government areas (LGAs) of Ogun State were measured using AlphaGUARD radon detector and AquaKIT. The mean activity concentration of radon ranged from 1.23 ± 0.21 to 12.68 ± 18.11 Bq.l-1 corresponding to geometric means (GMs) of 1.22- 6.39 Bq.l-1. The radon concentr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa221

    authors: Fatoki OO,Ademola JA

    更新日期:2021-02-03 00:00:00