Characterization Of A Lanthanum Bromide Detector For Eye Lens Dosimetry At The Candu Nuclear Power Plants Based On Direct Measurements Of The Gamma-Ray Spectra.

Abstract:

:Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers' exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power and Ontario Power Generation (OPG) CANDU nuclear power plants, where workers are exposed to relatively high dose rates radiation fields during the maintenance work. Prior to measurements at the CANDU reactors, the pulse shaping parameters of the gamma spectrometer were optimised for high rates gamma fields, up to an input rates of 120 kcps, in order to accomplish a high output rate with a reasonable energy resolution. In parallel, the response of the LaBr$_{3}$(Ce) detector was characterized by experiments and Monte Carlo simulations. The gamma spectra measured at the CANDU reactors were reported in terms of the gamma-ray fluence rate spectrum. In all measured data, $^{60}$Co and $^{95}$Nb were main contributors of the gamma fields. The measured spectra have been used to calculate the dosimetric quantities of interest: personal dose equivalents H$_{p}$(10) and H$_{p}$(0.07) and eye lens absorbed dose.

journal_name

Radiat Prot Dosimetry

authors

Laranjeiro AS,Bohra F,Byun SH,Atanackovic J,Hanu AR

doi

10.1093/rpd/ncaa186

subject

Has Abstract

pub_date

2020-12-15 00:00:00

eissn

0144-8420

issn

1742-3406

pii

6035111

pub_type

杂志文章
  • The in vivo assessment of thorium body burden by gamma ray sepctrometry.

    abstract::Thorium is used in many different industrial technologies and is widely found in nature. Internal contamination with thorium is considered as highly hazardous because of its radiological and chemical toxicities, which depend on the chemical form in which thorium appears. The assessment of the thorium body burden is th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006656

    authors: Genicot JL,Bruggeman M

    更新日期:2001-01-01 00:00:00

  • Personal monitor glass badge: theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX.

    abstract::This paper describes the results of the simulation of a radiophotoluminescent (RPL) dosemeter with the Monte Carlo transport code MCNPX. The aim of this study is to calculate the response with MCNPX of the RPL dosemeter in terms of equivalent doses H(p) (0.07) and H(p)(10) using X-ray photon radiation qualities N seri...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr009

    authors: Hocine N,Donadille L,Huet C,Itié C,Clairand I

    更新日期:2011-03-01 00:00:00

  • Neutron and photon fields in the BNCT room with closed beam shutters.

    abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci112

    authors: Marek M,Viererbl L

    更新日期:2005-01-01 00:00:00

  • Issues, considerations and recommendations on emergency preparedness for vulnerable population groups.

    abstract::The Workshop on Emergency Preparedness for Vulnerable Population Groups was held on 2 and 3 March 2009 in Ottawa, ON, Canada. The purpose of the workshop was to enhance communications within the emergency community response network and to identify the needs and gaps of emergency preparedness against chemical, biologic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp083

    authors: Chen J,Wilkinson D,Richardson RB,Waruszynski B

    更新日期:2009-06-01 00:00:00

  • Why can't we find a better biological indicator of dose?

    abstract::The three general principles of the International Commission on Radiological Protection (ICRP) are: justification, optimisation (ALARA) and dose limitation. The principle application of optimisation (ALARA) for occupational exposures of workers or the public to external radiation is reliant on low doses being assessed...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch094

    authors: Voisin P,Roy L,Benderitter M

    更新日期:2004-01-01 00:00:00

  • Neutron measurements in a Varian 2,100C LINAC facility using a Bonner sphere system based on passive gold activation detectors.

    abstract::The use of high-energy linear electron accelerators (LINACs) for medical cancer treatments is widespread on an international scale. The associated bremsstrahlung X rays may produce neutrons as a result of subsequent photonuclear reactions with the different materials constituting the accelerator head. The generated ne...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm075

    authors: Fernández F,Domingo C,Amgarou K,Castelo J,Bouassoule T,Garcia MJ,Luguera E

    更新日期:2007-01-01 00:00:00

  • Cytogenic investigations of serious overexposures to an industrial gamma radiography source.

    abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006090

    authors: Sevan'kaev AV,Lloyd DC,Edwards AA,Moquet JE,Nugis VY,Mikhailova GM,Potetnya OI,Khvostunov IK,Guskova AK,Baranov AE,Nadejina NM

    更新日期:2002-01-01 00:00:00

  • EVALUATION OF NEUTRON SCATTERING CORRECTION USING THE SEMI-EMPIRICAL METHOD AND THE SHADOW-CONE METHOD FOR THE NEUTRON FIELD OF THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE.

    abstract::When neutron survey metres are calibrated in neutron fields, the results for room- and air-scattered neutrons vary according to the distance from the source and the size, shape and construction of the neutron calibration room. ISO 8529-2 recommends four approaches for correcting these effects: the shadow-cone method, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx219

    authors: Lee SK,Kim SI,Lee J,Chang I,Kim JL,Kim H,Kim MC,Kim BH

    更新日期:2018-08-01 00:00:00

  • The TSL neutron beam facility.

    abstract::A new quasi-monoenergetic neutron beam facility has been constructed at The Svedberg Laboratory (TSL) in Uppsala, Sweden. Key features include a neutron energy range of 11-175 MeV, high fluxes, user flux control, flexible neutron field size and shape, and spacious and easily accessible user area. The first results of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm006

    authors: Prokofiev AV,Blomgren J,Byström O,Ekström C,Pomp S,Tippawan U,Ziemann V,Osterlund M

    更新日期:2007-01-01 00:00:00

  • A study of the correlation between dose area product and effective dose in vascular radiology.

    abstract::The purpose of the multi-centre study was to assess dose area product (DAP) and effective dose of patients undergoing angiography of the lower limbs in Belgium and to investigate the correlation between DAP and effective dose. DAP values were measured in 12 centres and compared with the national diagnostic reference l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn050

    authors: Smans K,Struelens L,Hoornaert MT,Bleeser F,Buls N,Berus D,Clerinx P,Malchair F,Vanhavere F,Bosmans H

    更新日期:2008-01-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00

  • Organ dose conversions from ESR measurements using tooth enamel of atomic bomb survivors.

    abstract::Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr408

    authors: Takahashi F,Sato K

    更新日期:2012-03-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • ITERATIVE SCATTER CORRECTION FOR GRID-LESS BEDSIDE CHEST RADIOGRAPHY: PERFORMANCE FOR A CHEST PHANTOM.

    abstract::The aim of this work was to experimentally compare the contrast improvement factors (CIFs) of a newly developed software-based scatter correction to the CIFs achieved by an antiscatter grid. To this end, three aluminium discs were placed in the lung, the retrocardial and the abdominal areas of a thorax phantom, and di...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv432

    authors: Mentrup D,Jockel S,Menser B,Neitzel U

    更新日期:2016-06-01 00:00:00

  • RECOMMENDATIONS FOR MONITORING AND INTERNAL DOSIMETRY FOR NUCLEAR MEDICINE STAFF EXPOSED TO RADIOPHARMACEUTICALS 223Ra DICHLORIDE.

    abstract::223Ra is a radiopharmaceutical used as unsealed source in nuclear medicine. In the case of staff inhalation contamination of 223Ra, methods to estimate the committed effective dose should be chosen with care. Three methods are available: whole-body measurement and gamma spectrometry for urine or faeces samples. Consid...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy065

    authors: Saurat D,Aupée O,Gontier E,Métivier D,Cazoulat A,Lecompte Y

    更新日期:2018-12-01 00:00:00

  • AVIDOS--a software package for European accredited aviation dosimetry.

    abstract::AVIDOS is a computer code used for the dose assessment of aircraft crew exposed to cosmic radiation. The code employs a multiparameter model built upon simulations of cosmic radiation exposure done using the FLUKA Monte Carlo code. AVIDOS calculates both ambient dose equivalent H*(10) and effective dose E for flight r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp126

    authors: Latocha M,Beck P,Rollet S

    更新日期:2009-10-01 00:00:00

  • Measurement of patient radiation doses in certain urography procedures.

    abstract::Patients are exposed to significant radiation doses during diagnostic and interventional urologic procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv185

    authors: Sulieman A,Barakat H,Zailae A,Abuderman A,Theodorou K

    更新日期:2015-07-01 00:00:00

  • LEAD COMPOSITE VS. NONLEAD PROTECTIVE GARMENTS: WHICH ARE BETTER? A MULTIVENDOR COMPARISON.

    abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw373

    authors: Peters SMB,Zweers D,de Lange F,Mourik JEM

    更新日期:2017-08-01 00:00:00

  • Dose conversion of radon exposure according to new epidemiological findings.

    abstract::In 1993, ICRP-65 recommended that dose conversion of radon exposure should be based on the comparison of detriments between radon exposure and effective dose. The lifetime detriment from the radon exposure was projected according to the epidemiological studies of uranium miners then available. The projection model (GS...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn117

    authors: Tomasek L,Rogel A,Laurier D,Tirmarche M

    更新日期:2008-01-01 00:00:00

  • A new position recording system for the partial-body counter at KIT.

    abstract::The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq416

    authors: Hegenbart L,Breustedt B

    更新日期:2011-03-01 00:00:00

  • High-Dose TL Dosimetry of Reactor Neutrons.

    abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx244

    authors: Obryk B,Malik K,Bilski P,Igielski A,Dankowski J,Kurowski A,Prokopowicz R,Pytel K

    更新日期:2018-08-01 00:00:00

  • Variability of radiocaesium inventory in Fukushima soil cores from one site measured at different times.

    abstract::The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident has resulted in the deposition of radioactive contamination of soils mainly by (134)Cs and (137)Cs. The contaminated areas are of a great concern since external radiation may lead to significant long-term doses to humans and animals. External dose rate above g...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv276

    authors: Mishra S,Sahoo SK,Arae H,Sorimachi A,Hosoda M,Tokonami S,Ishikawa T

    更新日期:2015-11-01 00:00:00

  • Radon in thermal waters in south-east part of Serbia.

    abstract::There are several occurrences of thermal waters in the south-eastern part of Serbia, which are originating from igneous and metamorphic rocks. These waters are mainly used in balneology, but some of them are used for drinking purposes and in water supply to heat buildings, for greenhouses and to irrigate land. In this...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu094

    authors: Nikolov J,Todorović N,Bikit I,Pantić TP,Forkapić S,Mrđa D,Bikit K

    更新日期:2014-07-01 00:00:00

  • Induced radioactivity in the ESRF storage ring.

    abstract::The new French radiation protection legislation requires the definition of the zoning of accelerator facilities with respect to radioactive waste. This activation inside the ESRF 6 GeV storage ring is essentially due to photonuclear reactions. This paper describes the first results of Monte Carlo calculations that wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci070

    authors: Berkvens P

    更新日期:2005-01-01 00:00:00

  • Assessment of patient organ doses and effective doses using the VIP-Man adult male phantom for selected cone-beam CT imaging procedures during image guided radiation therapy.

    abstract::A Monte Carlo based computational procedure for determining organ doses and effective doses has been described for two procedures used in newly developed image-guided radiation treatment: kilovoltage cone-beam computed tomography (kV CBCT) and mega-voltage computed tomography (MV CBCT). A whole-body patient computatio...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn200

    authors: Gu J,Bednarz B,Xu XG,Jiang SB

    更新日期:2008-01-01 00:00:00

  • ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    abstract::Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy041

    authors: Jeong J,Ko NY,Cho DK,Baik MH,Yoon KH

    更新日期:2018-11-01 00:00:00

  • Design of a multi-element TEPC for neutron monitoring.

    abstract::Tissue-equivalent proportional counters (TEPCs) have long been considered suitable candidate instruments for more accurate neutron monitors in nuclear power plants. It has also been recognised that the production of truly light-weight devices based on TEPCs requires further effort directed towards increasing their sen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq538

    authors: Waker AJ,Aslam,Lori J

    更新日期:2011-02-01 00:00:00

  • In vivo thermoluminescence dosimetry for total body irradiation.

    abstract::An improvement in the clinical results obtained using total body irradiation (TBI) with photon beams requires precise TBI treatment planning, reproducible irradiation, precise in vivo dosimetry, accurate documentation and careful evaluation. In vivo dosimetry using LiF Harshaw TLD-100 chips was used during the TBI tre...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006058

    authors: Palkosková P,Hlavata H,Dvorák P,Novotný J,Novotný J Jr

    更新日期:2002-01-01 00:00:00

  • Optimised geometry to calculate dose rate conversion coefficient for external exposure to photons.

    abstract::A single-parameter geometry to describe soil is achieved for Monte Carlo calculation of absorbed dose rate in air for photon emitters from natural radionuclides. This optimised geometry based on physical assumptions consists of the soil part whose emitted radiation has a given minimum probability to reach the detector...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm426

    authors: Askri B,Manai K,Trabelsi A,Baccari B

    更新日期:2008-01-01 00:00:00

  • RESULTS OF THE JOINT IAEA/ARPANSA INTERCOMPARISON EXERCISE ON WHOLE BODY DOSEMETERS FOR PHOTONS IN ASIA AND THE PACIFIC REGION.

    abstract::An intercomparison exercise (IC) on whole body dosemeters to determine the quantity personal dose equivalent Hp (10) in photon radiation fields was jointly organised and conducted by the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for individual...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz182

    authors: Rizk C,Long S,Okyar HB,Baradaran S,Al Fares E,Sangau JK,Shah BR

    更新日期:2019-12-31 00:00:00