Abstract:
:Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organs or whole-body doses, however, are assumed to be near the tooth enamel dose for photon energies which are dominant in the leakage spectrum of the Hiroshima atomic bomb assumed in DS02. In addition, the thyroid can be a candidate for a surrogate organ in cases where the tooth enamel dose is not available in organ dosimetry. This paper also suggests the application of new Japanese voxel phantoms to derive tooth enamel doses by numerical analyses.
journal_name
Radiat Prot Dosimetryjournal_title
Radiation protection dosimetryauthors
Takahashi F,Sato Kdoi
10.1093/rpd/ncr408subject
Has Abstractpub_date
2012-03-01 00:00:00pages
67-70issue
1eissn
0144-8420issn
1742-3406pii
ncr408journal_volume
149pub_type
杂志文章abstract::A high-end drum film digitiser (Tango, Germany) and a calibrated linear microdensitometer developed by PTB were used to assess the modulation transfer function (MTF) and the noise power spectra (NPS) of 3 mammographic screen film systems at optical density levels of 0.8, 1.5 and 2.5. The use of a drum scanner to asses...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch563
更新日期:2005-01-01 00:00:00
abstract::TRIPOLI-4.3 Monte Carlo transport code has been used to evaluate the QUADOS (Quality Assurance of Computational Tools for Dosimetry) problem P4, neutron and photon response of an albedo-type thermoluminescence personal dosemeter (TLD) located on an ISO slab phantom. Two enriched 6LiF and two 7LiF TLD chips were used a...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci032
更新日期:2005-01-01 00:00:00
abstract::The National Institute for Occupational Safety and Health (NIOSH) is currently studying mortality in a cohort of 6409 workers at a former uranium processing facility. As part of this study, over 220 000 urine samples were used to reconstruct organ doses due to internal exposure to uranium. Most of the available comput...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncs097
更新日期:2013-01-01 00:00:00
abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch237
更新日期:2004-01-01 00:00:00
abstract::The relation of radiation exposure (dose) with acute radiation syndrome (ARS) depends on many factors. In this overview, we reconsider (1) radiation exposure characteristics (e.g. radiation quality, fractionation, dose rate, partial/total body irradiation) and (2) biological processes (e.g. radiosensitivity, cell cycl...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncz058
更新日期:2019-12-31 00:00:00
abstract::Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl144
更新日期:2007-01-01 00:00:00
abstract::A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl468
更新日期:2006-01-01 00:00:00
abstract::The E. coli catabolite gene activator protein (CAP)-DNA complex with 125I located at the position of the H5 atom of the cytosine near the centre was incorporated into the PARTRAC track structure code. DNA strand breaks due to irradiation were calculated by track structure and radical attack simulations; strand breaks ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006738
更新日期:2002-01-01 00:00:00
abstract::Data collection and its analysis in the field of nuclear safety is an important task in the sense that it powers the improvement of safety as well as reliability of the plant. Thus, occupational exposure data analysis is presented to measure the safety or reliability of radiation protection of a given facility. It als...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm483
更新日期:2008-01-01 00:00:00
abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq104
更新日期:2010-04-01 00:00:00
abstract::Radon measurements were carried out in Kozlu, Karadon and Uzülmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch449
更新日期:2005-01-01 00:00:00
abstract::The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found between indoor thoron and its progeny, and the concentration of thoron progeny varies with time, it is necessary to develop detectors for long-term measurement that...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr078
更新日期:2011-05-01 00:00:00
abstract::At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to rad...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncl475
更新日期:2007-01-01 00:00:00
abstract::The current revision of the Swiss Radiological Protection Ordinance aims to bring Swiss legislation in line with new international standards. In future, the control of radon exposure in dwellings will be based on a reference level of 300 Bq m(-3). Since this value is exceeded in >10 % of the buildings so far investiga...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu307
更新日期:2015-04-01 00:00:00
abstract::Eyeglass lenses are commonly composed of allyl-diglycol carbonate (CR-39), an alpha-particle detecting plastic, thus making such lenses personal radon dosemeters. Samples of such lenses have been obtained, etched to reveal that radon and radon progeny alpha tracks can be seen in abundance, and sensitivities have been ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006670
更新日期:2001-01-01 00:00:00
abstract::Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncn237
更新日期:2008-01-01 00:00:00
abstract::Virtual models of real phantoms used with Monte Carlo methods facilitate the calibration and other studies associated with whole-body and partial-body counting systems. In this investigation, a voxel model of an LLNL torso phantom, available physically in the in vivo laboratory at KIT, was created from computed tomogr...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncp030
更新日期:2009-02-01 00:00:00
abstract::Some data were derived using recent sophisticated methods to rapidly convert specific activity of induced 24Na to average dose over a whole body in criticality accidents. Monte Carlo calculations using the MCNP-4B code were performed to study energy spectra of neutrons and gamma rays for some criticality systems with ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/oxfordjournals.rpd.a006350
更新日期:2003-01-01 00:00:00
abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu221
更新日期:2014-11-01 00:00:00
abstract::The observation of anomalies in the radon concentration in soil gas and ground water before earthquakes initiated systematic investigations on earthquake precursor phenomena. The question what is needed for a meaningful earthquake prediction as well as what types of precursory effects can be expected is shortly discus...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncr229
更新日期:2012-04-01 00:00:00
abstract::The physical data regarding bremsstrahlung and neutrons produced in a steel shield by high-energy electron beams from a medical linear accelerator were investigated. These data are required to allow the accurate prediction of shielding performance for high-energy electron beams and in the design of radiotherapy facili...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu153
更新日期:2015-02-01 00:00:00
abstract::Thermoluminescene (TL) and mechanoluminescence (ML) properties of gamma-irradiated Dy activated potassium and magnesium mixed sulphate have been studied. (K2Mg2:Dy) (SO4)3 samples having different concentrations of Dy were prepared by solid-state diffusion method. Two distinct peaks, the first approximately 130 degree...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci607
更新日期:2006-01-01 00:00:00
abstract::Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamon...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nci667
更新日期:2006-01-01 00:00:00
abstract::During the past decades, many specialised networks have formed to meet specific radioecological objectives, whether regional or sectorial (purpose-oriented). Regional networks deal with an array of radioecological issues related to their territories. Examples include the South Pacific network of radioecologists, and t...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw290
更新日期:2017-04-01 00:00:00
abstract::The three general principles of the International Commission on Radiological Protection (ICRP) are: justification, optimisation (ALARA) and dose limitation. The principle application of optimisation (ALARA) for occupational exposures of workers or the public to external radiation is reliant on low doses being assessed...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/nch094
更新日期:2004-01-01 00:00:00
abstract::Biokinetic models are the scientific underpinning of internal dosimetry and depend, ultimately, for their scientific validation on comparisons with human bioassay data. Three significant plutonium/americium bioassay databases, known to the authors, are described: (1) Sellafield, (2) Los Alamos and (3) the United State...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncm164
更新日期:2007-01-01 00:00:00
abstract::The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncq416
更新日期:2011-03-01 00:00:00
abstract::Relatively high organ doses absorbed by patients in interventional cardiology suggest the opportunity to define these patients as a cohort to be followed forward in time in an epidemiological study of the cancer risks associated with exposure to low-dose ionising radiation. In this paper, the UNSCEAR 2000 Report risk ...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章,评审
doi:10.1093/rpd/ncn036
更新日期:2008-01-01 00:00:00
abstract::This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncw349
更新日期:2017-04-01 00:00:00
abstract::UVA wavelengths (320-400 nm) have been implicated in recent studies to contribute to melanoma induction and skin photoaging in humans and damage to plants. The use of smartphones in UVA observations is a way to supplement measurements made by traditional radiometric and spectroradiometric technology. Although the smar...
journal_title:Radiation protection dosimetry
pub_type: 杂志文章
doi:10.1093/rpd/ncu344
更新日期:2015-12-01 00:00:00