Evaluation of the radioactivity of the pre-dominant gamma emitters in components used at high-energy proton accelerator facilities.

Abstract:

:At a high-energy, high-intensity proton accelerator facility, the accelerator components inside the beam-line tunnel and the concrete wall of the tunnel are activated due to beam loss during operation. During maintenance work inside the tunnel, radiation emitted from these activated materials can cause exposure to radiation workers. In this study, the relation between the surface dose rate of activated materials and the induced radioactivity was considered, and an evaluation of the major radioactivity using the surface dose rate was made. It has been revealed that (22)Na in Al samples and (54)Mn in Fe samples, (60)Co and (54)Mn in Fe samples, and (60)Co in Fe and Cu samples are principal residual radionuclides after a few hundred days of cooling about a few years of cooling and approximately 10 y of cooling, respectively.

journal_name

Radiat Prot Dosimetry

authors

Numajiri M

doi

10.1093/rpd/ncl475

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

417-25

issue

4

eissn

0144-8420

issn

1742-3406

pii

ncl475

journal_volume

123

pub_type

杂志文章
  • Estimation of thoron concentration using scintillation cell.

    abstract::Two counting techniques are proposed in this paper to estimate thoron ((220)Rn) concentration using a Lucas scintillation cell. The alpha activity build-up inside the cell is calculated theoretically by using Bateman equations. The first method is having a minimum detection limit of 325 Bq m(-3) and can be used for th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr438

    authors: Sumesh CG,Kumar AV,Nair RN,Tripathi RM,Puranik VD

    更新日期:2012-07-01 00:00:00

  • A high-sensitivity method for the measurement of 222Rn based on liquid scintillation counting of polycarbonate powder.

    abstract::This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu075

    authors: Mitev K,Georgiev S,Pressyanov D,Dimitrova I,Zhivkova V,Boshkova T

    更新日期:2014-07-01 00:00:00

  • Radiological emergency: Malaysian preparedness and response.

    abstract::Planning and preparation in advance for radiological emergencies can help to minimise potential public health and environmental threats if and when an actual emergency occurs. During the planning process, emergency response organisations think through how they would respond to each type of incident and the resources t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr102

    authors: Yusof MA,Ali HM

    更新日期:2011-07-01 00:00:00

  • A recoil-proton spectrometer based on a p-i-n diode implementing pulse-shape discrimination.

    abstract::A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch237

    authors: Agosteo S,D'Angelo G,Fazzi A,Foglio Para A,Pola A,Ventura L,Zotto P

    更新日期:2004-01-01 00:00:00

  • Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filters.

    abstract::Amongst the dosemeters offered by the Health Protection Agency (HPA) Personal Dosimetry Service are finger rings, which use the Harshaw™ DXTRAD element. This paper describes restricted-type testing carried out by HPA on the previously untried combination of the LiF:Mg,Cu,P material and a thicker filter (42 mg cm(-2))....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq564

    authors: Baker ST,Roberts GH,Gilvin PJ

    更新日期:2011-03-01 00:00:00

  • ELECTRON EYE-LENS OPERATIONAL DOSE COEFFICIENTS.

    abstract::In 2012, the International Commission on Radiological Protection issued a recommendation for a reduced annual eye-lens dose limit in the face of mounting evidence of the risk of cataract induction. This led to worldwide research efforts in various areas including the dose simulation in realistic eye-models, the produc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz295

    authors: Dubeau J,Sun J

    更新日期:2020-06-24 00:00:00

  • Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

    abstract::In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp019

    authors: Bakshi AK,Pradhan AS,Kher RK,Srivastava K,Varadharajan G,Chatterjee S,Sathian V

    更新日期:2009-01-01 00:00:00

  • DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    abstract::The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx291

    authors: Forouzan F,Waker AJ

    更新日期:2018-08-01 00:00:00

  • Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

    abstract::Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl144

    authors: Falcão RC,Facure A,Silva AX

    更新日期:2007-01-01 00:00:00

  • Radiation protection issues for laser-based accelerators.

    abstract::Radiation particles, besides their application to fundamental research, are widely applied in all fields of science (medicine, material science, chemistry, etc.). Up to today the radiations were produced by radiation sources such as accelerators, X-ray tubes, radioactive sources with the well-known problems of costs, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr239

    authors: Esposito A

    更新日期:2011-07-01 00:00:00

  • Plutonium in the Ozyorsk population.

    abstract::Results of the long-term autopsy studies on plutonium body burden in the population of Ozyorsk situated in the vicinity of the radiochemical plant of the Mayak Production Association (Russia) have been presented. The data were obtained from radiochemical analysis of the soft tissue and bone samples collected at the au...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm303

    authors: Suslova KG,Khokhryakov VF,Sokolova AB

    更新日期:2007-01-01 00:00:00

  • DOSE ASSESSMENT OF NATURAL TERRESTRIAL RADIONUCLIDES IN COMMONLY CONSUMED FOODS IN NORTH INDIA.

    abstract::The present study aimed to record natural radionuclide content in branded food samples representative of a typical North Indian diet. Forty samples of various food items falling into three categories namely, cereal grains, pulses and beverages were collected from the local markets of Punjab. The radiometric analysis w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa050

    authors: Kaur S,Maheshwari P,Mehra R

    更新日期:2020-07-17 00:00:00

  • DOSE AREA PRODUCT VALUES OF FLUOROSCOPICALLY GUIDED PAIN MANAGEMENT PROCEDURES: COMPARISON OF A BELGIAN TEACHING HOSPITAL WITH NATIONAL DIAGNOSTIC REFERENCE LEVELS.

    abstract::In 2011, national diagnostic reference levels (DRLs) were proposed for pain management fluoroscopic procedures in Belgium. The primary goal of this work is to compare the dose area product values (DAP) recorded at the Saint-Luc University Hospital to these DRLs. From 2012 to 2015, 7664 interventional pain management p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx271

    authors: Hustinx N,Steyaert A,le Polain de Waroux B,Forget P

    更新日期:2018-05-01 00:00:00

  • DNA fragments induction in human fibroblasts by radiations of different qualities.

    abstract::Experimental data on DNA double strand break (DSB) induction in human fibroblasts (AG1522), following irradiation with several radiation qualities, namely gamma rays, 0.84 MeV protons, 58.9 MeV u(-1) carbon ions, iron ions of 115 MeV u(-1), 414 MeV u(-1), 1 GeV u(-1), and 5 GeV u(-1), are presented. DSB yields were me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl389

    authors: Esposito G,Belli M,Campa A,Cherubini R,Cuttone G,Dini V,Furusawa Y,Gerardi S,Simone G,Sorrentino E,Tabocchini MA

    更新日期:2006-01-01 00:00:00

  • Contribution of different foodstuffs to the internal exposure of rural inhabitants in Russia after the Chernobyl accident.

    abstract::In a large village, Veprin of the Bryansk region of Russia contaminated with radionuclides as a result of the Chernobyl accident, 137Cs concentration in food products of agricultural produce and natural origin was regularly measured, local inhabitants were polled on the composition of their diet, and the 137Cs content...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006445

    authors: Travnikova IG,Bruk GJ,Shutov VN,Bazjukin AB,Balonov MI,Rahola T,Tillander M

    更新日期:2001-01-01 00:00:00

  • CALCULATION OF SKIN DOSE DUE TO BETA CONTAMINATION USING THE NEW QUANTITY OF THE ICRP 116: THE 'LOCAL SKIN DOSE'.

    abstract::Values of the new protection quantity 'Local Skin Dose' LSD, introduced by the International Commission on Radiological Protection (ICRP) Publication 116, were calculated for 134 β- or β+ emitting radionuclides, using the Monte Carlo code MCNP6. Two types of source geometry are considered: a point source and disc-type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx019

    authors: Bourgois L,Ménard S,Comte N

    更新日期:2017-11-01 00:00:00

  • Estimation of internal exposure to uranium with uncertainty from urinalysis data using the InDEP computer code.

    abstract::The National Institute for Occupational Safety and Health (NIOSH) is currently studying mortality in a cohort of 6409 workers at a former uranium processing facility. As part of this study, over 220 000 urine samples were used to reconstruct organ doses due to internal exposure to uranium. Most of the available comput...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs097

    authors: Anderson JL,Apostoaei AI,Thomas BA

    更新日期:2013-01-01 00:00:00

  • Cytogenic investigations of serious overexposures to an industrial gamma radiography source.

    abstract::This paper describes the sequence of events, medical aspects and dose estimations for two radiographers and their driver who were seriously exposed to an iridium-192 industrial radiography source that became detached from its wind-out cable. The men came to medical attention about 1 month later by which time all three...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006090

    authors: Sevan'kaev AV,Lloyd DC,Edwards AA,Moquet JE,Nugis VY,Mikhailova GM,Potetnya OI,Khvostunov IK,Guskova AK,Baranov AE,Nadejina NM

    更新日期:2002-01-01 00:00:00

  • A minimally invasive method to evaluate 131I kinetics in blood.

    abstract::The dose limiting factor for 131I therapy in patients with thyroid cancer is myelotoxicity, thus an accurate determination of radioiodine activity in the red marrow is of paramount importance. The reference method for red marrow dosimetry in radiometabolic therapy is based on the measurement of radioiodine kinetics, p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch041

    authors: Traino AC,Di Martino F,Boni G,Mariani G,Lazzeri M

    更新日期:2004-01-01 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures.

    abstract::In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs in the Sou...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006486

    authors: Waite JC,Fitzgerald M

    更新日期:2001-01-01 00:00:00

  • RESULTS OF THE JOINT IAEA/ARPANSA INTERCOMPARISON EXERCISE ON WHOLE BODY DOSEMETERS FOR PHOTONS IN ASIA AND THE PACIFIC REGION.

    abstract::An intercomparison exercise (IC) on whole body dosemeters to determine the quantity personal dose equivalent Hp (10) in photon radiation fields was jointly organised and conducted by the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for individual...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz182

    authors: Rizk C,Long S,Okyar HB,Baradaran S,Al Fares E,Sangau JK,Shah BR

    更新日期:2019-12-31 00:00:00

  • LUNG CANCER LIFETIME RISKS IN COHORT STUDIES OF URANIUM MINERS.

    abstract::The article summarizes the most recent results from the cohorts of uranium miners, particularly the risks at low exposures and the risk models with modifying effects of exposure rate, age and time since exposure, which are used for the calculation of lifetime risks (LRs). The excess relative risks per unit exposure (E...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa143

    authors: Tomasek L

    更新日期:2020-11-27 00:00:00

  • Determination of natural radioactivity in building materials used in Tunisian dwellings by gamma ray spectrometry.

    abstract::The radioisotopic content of 17 samples of natural and manufactured building materials collected in Tunisia have been analysed by using gamma spectrometry. From the measured gamma ray spectra, activity concentrations are determined for (232)Th, (226)Ra, (235)U and (40)K. The total effective dose and the activity conce...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch489

    authors: Hizem N,Ben Fredj A,Ghedira L

    更新日期:2005-01-01 00:00:00

  • CONCEPTS OF OPERATIONS FOR A US DOSIMETRY AND BIODOSIMETRY NETWORK.

    abstract::The USA must be prepared to provide a prompt, coordinated and integrated response for radiation dose and injury assessment for suspected radiation exposure, whether it involves isolated cases or mass casualties. Dose estimation for radiation accidents typically necessitates a multiple parameter diagnostics approach th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy294

    authors: Dainiak N,Albanese J,Kaushik M,Balajee AS,Romanyukha A,Sharp TJ,Blakely WF

    更新日期:2019-12-31 00:00:00

  • Influence of the uniformity of the slab phantom illumination on the calibration of personal dosemeters.

    abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq036

    authors: Ankerhold U,Ambrosi P

    更新日期:2010-06-01 00:00:00

  • Assessments of medical exposures during interventional radiology procedures.

    abstract::This study aims to contribute to the construction of a scenario regarding patient radiation exposure in Brazilian interventional radiology, aiming to provide data for the future drafting of specific legislation on interventional radiology because there is currently a lack of safety regulations for haemodynamics servic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs172

    authors: Navarro VC,Navarro MV,Maia AF

    更新日期:2013-04-01 00:00:00

  • Microdosimetric modelling of the response of thermoluminescence detectors to low- and high-LET ionising radiation.

    abstract::The microdosimetric one hit detector model was applied to calculate the dose response, energy response and relative thermoluminescence (TL) efficiency, eta, of high sensitive LiF:Mg,Cu,P and Al(2)O(3):C detectors after their irradiations by X rays, gamma rays, beta electrons and heavy charged particles (HCP). Microdos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl467

    authors: Olko P,Bilski P,Budzanowski M,Czopyk L,Swakon J,Waligorski MP

    更新日期:2006-01-01 00:00:00

  • Measurement of patient radiation doses in certain urography procedures.

    abstract::Patients are exposed to significant radiation doses during diagnostic and interventional urologic procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethogr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv185

    authors: Sulieman A,Barakat H,Zailae A,Abuderman A,Theodorou K

    更新日期:2015-07-01 00:00:00

  • Impact of high-energy nuclear data on radioprotection in spallation sources.

    abstract::The high-energy programme of the HINDAS European project has provided a large amount of experimental data and led to a better understanding of the spallation reaction mechanism and the development of more reliable spallation models. These data, or the new models, which have been implemented into high-energy transport ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci086

    authors: Leray S,Boudard A,David JC,Donadille L,Villagrasa C,Volant C

    更新日期:2005-01-01 00:00:00