Personal monitor glass badge: theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX.

Abstract:

:This paper describes the results of the simulation of a radiophotoluminescent (RPL) dosemeter with the Monte Carlo transport code MCNPX. The aim of this study is to calculate the response with MCNPX of the RPL dosemeter in terms of equivalent doses H(p) (0.07) and H(p)(10) using X-ray photon radiation qualities N series, together with S-Cs and S-Co nuclide radiation qualities, specified in ISO 4037-1. After comparison with reference values versus experimental results, the deviation of the theoretical responses of the RPL dosemeter proved to be lower than 5 % for reference values and lower than 10 % for experimental results. This good correlation validates the model over the energy range studied.

journal_name

Radiat Prot Dosimetry

authors

Hocine N,Donadille L,Huet C,Itié C,Clairand I

doi

10.1093/rpd/ncr009

subject

Has Abstract

pub_date

2011-03-01 00:00:00

pages

231-3

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

ncr009

journal_volume

144

pub_type

杂志文章
  • Long-term measurements of radon equilibrium factor in Greek dwellings.

    abstract::The time variation of the radon equilibrium factor F was measured every four hours in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki (in northern Greece) during October 1998-April 1999. The time dependence of the mean weekly value of radon equilibrium factor F is relatively small. During...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006143

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • COMPARISON METHODOLOGIES FOR CALIBRATION OF Hp(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDS.

    abstract::The calibration of electronic personal dosemeters at the Portuguese ionizing radiation metrology laboratory uses the standard IEC 61526 for calibration methodology. This standard describes the irradiation geometry for testing and indicates that the standard ISO 4037-1, 2, 3 and 4 should be used. The ISO 4037 establish...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw126

    authors: Cardoso J,Santos L,Carvalhal G,Oliveira C

    更新日期:2016-09-01 00:00:00

  • Correlation of patient maximum skin doses in cardiac procedures with various dose indicators.

    abstract::In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn247

    authors: Domienik J,Papierz S,Jankowski J,Peruga JZ,Werduch A,Religa W

    更新日期:2008-01-01 00:00:00

  • 'Lifestyle' and cancer rates in former East and West Germany: the possible contribution of diagnostic radiation exposures.

    abstract::Breast and prostatic cancer as well as leukaemia in childhood have remarkably increased over some decades in the Federal Republic of Germany as well as in several other highly developed industrial nations. Such increase was much less or not observable in East Germany between 1960 and 1989 where diagnostic exposures we...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr348

    authors: Schmitz-Feuerhake I,Pflugbeil S

    更新日期:2011-09-01 00:00:00

  • Dose effect for South Serbians due to 238U in natural drinking water.

    abstract::The use of depleted uranium ammunition in South Serbia during the 1999 Kosovo conflict raised a great deal of public concern in the Balkans. Radioactivity levels of 238U in 20 wells and lake water samples were checked from the viewpoint of internal radiation exposure for South Serbian subjects. We have measured 238U c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm294

    authors: Sahoo SK,Matsumoto M,Shiraishi K,Fujimoto K,Cuknic O,Zunic ZS

    更新日期:2007-01-01 00:00:00

  • The efficiency of various thermoluminescence dosemeter types to heavy ions.

    abstract::Dose verification in heavy-ion beams using passive dosemeter systems, e.g. thermoluminescence dosemeters (TLDs), is crucial due to the changing efficiency of the dosemeters for different ion species and linear energy transfer (LET) values. This behaviour leads to a falsification of absorbed dose that can be significan...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci582

    authors: Berger T,Hajek M,Summerer L,Fugger M,Vana N

    更新日期:2006-01-01 00:00:00

  • Biophysical analysis of radiation induced initial DNA fragmentation.

    abstract::Production of double strand breaks (DSBs) and double-stranded DNA fragments after irradiation with high energy nitrogen ions was simulated with stochastic track generation and a high-order chromatin structure (HOCS) model representing a segment of interphase chromosome. The non-random distribution of DNA fragments is ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006748

    authors: Khvostunov IK,Andreev SG,Eidelman Y

    更新日期:2002-01-01 00:00:00

  • Emission rate estimation through data assimilation of gamma dose measurements in a Lagrangian atmospheric dispersion model.

    abstract::This paper presents an efficient algorithm for estimating the unknown emission rate of radionuclides in the atmosphere following a nuclear accident. The algorithm is based on assimilation of gamma dose rate measured data in a Lagrangian atmospheric dispersion model. Such models are used in the framework of nuclear eme...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq592

    authors: Tsiouri V,Kovalets I,Andronopoulos S,Bartzis JG

    更新日期:2012-01-01 00:00:00

  • CAPABILITIES OF THE ARADOS-WG03 REGIONAL NETWORK FOR LARGE-SCALE RADIOLOGICAL AND NUCLEAR EMERGENCY SITUATIONS IN ASIA.

    abstract::In 2015, the Asian Radiation Dosimetry Group established a regional network of biological dosimetry laboratories known as the ARADOS-WG03 (Working Group 03; Biological Dosimetry). A survey was conducted in 2017 to evaluate the capabilities and capacities of the participating laboratories for emergency preparedness and...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy279

    authors: Jang S,Suto Y,Liu J,Liu Q,Zuo Y,Duy PN,Miura T,Abe Y,Hamasaki K,Suzuki K,Kodama S

    更新日期:2019-12-31 00:00:00

  • Usability of VTL from natural quartz grains for retrospective dosimetry.

    abstract::To develop retrospective dosimetry of unexpected radiation accident, basic studies on violet thermoluminescence (VTL) phenomena were conducted using natural quartz grains. All VTL glowcurves of as-received samples did not exhibit peaks <250 degrees C, although for artificially irradiated quartz samples there were VTL ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl108

    authors: Fujita H,Hashimoto T

    更新日期:2007-01-01 00:00:00

  • Results of field trials using the NPL simulated reactor neutron field facility.

    abstract::The NPL simulated reactor neutron field facility provides neutron spectra similar to those found in the environs of UK gas-cooled reactors. Neutrons are generated by irradiating a thick lithium-alloy target with monoenergetic protons between 2.5 and 3.5 MeV (depending on the desired spectrum), and then moderated by a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm018

    authors: Taylor GC,Thomas DJ,Bennett A

    更新日期:2007-01-01 00:00:00

  • Studies of patient doses in interventional radiological examinations.

    abstract::In Russia, especially in big cities like St. Petersburg, the annual number of interventional radiological (IR) examinations for both diagnostic and treatment purposes is increasing continuously. However, IR examinations might involve high patient doses and even the risk of skin injures that should be prevented. In thi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncq021

    authors: Sarycheva S,Golikov V,Kalnicky S

    更新日期:2010-04-01 00:00:00

  • Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations.

    abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq104

    authors: Hoeschen C,Mattsson S,Cantone MC,Mikuz M,Lacasta C,Ebel G,Clinthorne N,Giussani A

    更新日期:2010-04-01 00:00:00

  • Characterisation of workplaces with risks of internal exposures: air sampling.

    abstract::The measurement of air samples may be used to assess risks of internal exposures, either by the use of workplace static air samplers (SAS) or personal air samplers (PAS). These measurements need to incorporate information on the physical and chemical nature of the aerosol, and the relationship between the sampled and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncm397

    authors: Roberts GA,Bull RK

    更新日期:2007-01-01 00:00:00

  • Radiation safety assessment of a system of small reactors for distributed energy.

    abstract::A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, dee...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci208

    authors: Odano N,Ishida T

    更新日期:2005-01-01 00:00:00

  • COMPARISON STUDY OF VARIOUS PLASTICS AS THE WALL MATERIAL OF THGEM-BASED MICRODOSEMETERS FOR FAST NEUTRON MEASUREMENTS.

    abstract::To find appropriate substitutions for the expensive plastics of A-150 and rexolite used in the construction of thick gas electron multiplier (THGEM)-based tissue-equivalent proportional counters, in the present work, the responses of a THGEM-based microdosimetric detector made of A-150 and rexolite and three others co...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw008

    authors: Moslehi A,Raisali G,Lamehi M

    更新日期:2017-04-15 00:00:00

  • Long-term monitoring of radiation exposure of employees in the department of nuclear medicine (Szczecin, Poland) in the years 1991-2007.

    abstract::Occupational radiation exposure is a hazard that should be avoided or at least minimised. This study aimed to evaluate the radiation exposure of nuclear medicine department employees monitored during the 1991-2007 period, and to investigate the relationship between the annual effective doses of the personnel and the n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq117

    authors: Piwowarska-Bilska H,Birkenfeld B,Listewnik M,Zorga P

    更新日期:2010-08-01 00:00:00

  • Considerations and preliminary design of patient exposure registry.

    abstract::To aid in protecting patients from unnecessary exposures and to reduce radiation burdens to the public, a system for tracking a patient's medical exposure history and related radiation doses would be a useful tool. A patient-centred exposure registry, the Patient Exposure Registry (PER), is a mechanism that provides t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq280

    authors: Chen J,Moir D,Cornett J

    更新日期:2010-12-01 00:00:00

  • EDDIX--a database of ionisation double differential cross sections.

    abstract::The use of Monte Carlo track structure is a choice method in biophysical modelling and calculations. To precisely model 3D and 4D tracks, the cross section for the ionisation by an incoming ion, double differential in the outgoing electron energy and angle, is required. However, the double differential cross section c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq397

    authors: MacGibbon JH,Emerson S,Liamsuwan T,Nikjoo H

    更新日期:2011-02-01 00:00:00

  • A SIMULATION STUDY OF DEPOSITION PARAMETERS FOR 129I DISCHARGED FROM THE ROKKASHO REPROCESSING PLANT.

    abstract::The first commercial spent nuclear fuel reprocessing plant at Rokkasho in Japan discharged 129I from actual spent nuclear fuel into the atmosphere during its test operation from 2006 to 2008. Previously, we measured monthly atmospheric concentrations of gaseous and particulate 129I and atmospheric deposition rates of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz061

    authors: Abe K,Hasegawa H,Akata N,Kakiuchi H,Chiang JH,Suwa H,Hisamatsu S

    更新日期:2019-10-01 00:00:00

  • Calibration measurements and standards for radiation protection dosimetry.

    abstract::The safe use of ionising radiation for applications in medicine, electric power production and industrial processes requires accurate measurements that are traceable to national standards. Radiological calibration laboratories provide measurements that may be used to determine the calibration coefficients for personal...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nch308

    authors: McDonald JC

    更新日期:2004-01-01 00:00:00

  • A comparative study of dielectric response function models for liquid water.

    abstract::Various methodologies that aim at an analytic representation of the dielectric response function (DRF) of liquid water with emphasis on the Bethe ridge region are compared. The use of optical data is a common feature to all models presented providing an empirical ground for modelling the valence energy losses where ma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl414

    authors: Emfietzoglou D,Nikjoo H,Pathak A

    更新日期:2006-01-01 00:00:00

  • Radon progeny in hydrometeors at the earth's surface.

    abstract::During atmospheric thermal inversions, dew and hoarfrost concentrate gamma emitting radionuclides of the short-lived (222)Rn progeny ((214)Pb and (214)Bi), causing an increase in the total natural gamma background from the ground. To highlight this phenomenon, a volcanic zone of high (222)Rn flux was studied during th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr402

    authors: Voltaggio M

    更新日期:2012-07-01 00:00:00

  • Variability of radiocaesium inventory in Fukushima soil cores from one site measured at different times.

    abstract::The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident has resulted in the deposition of radioactive contamination of soils mainly by (134)Cs and (137)Cs. The contaminated areas are of a great concern since external radiation may lead to significant long-term doses to humans and animals. External dose rate above g...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv276

    authors: Mishra S,Sahoo SK,Arae H,Sorimachi A,Hosoda M,Tokonami S,Ishikawa T

    更新日期:2015-11-01 00:00:00

  • Development of a new passive integral dosemeter for gamma ray monitoring using an imaging plate.

    abstract::A new passive integral dosemeter for gamma ray monitoring is being developed using an imaging plate (IP). In the application of IPs to dosimetry, a fading effect causes serious problems. The fading is considered to be caused by the recombination or holes and charges trapped shallowly in the F centres, which have sever...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006396

    authors: Ohuchi H,Yamadera A,Baba M

    更新日期:2003-01-01 00:00:00

  • Developments in the internal dosimetry of radiopharmaceuticals.

    abstract::Various radionuclides are used in nuclear medicine in different diagnostic and therapeutic procedures. Recently, interest has grown in therapeutic agents for some interesting applications in nuclear medicine. Internal dose models and methods in use for many years are well established, and can give radiation doses to s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006306

    authors: Stabin MG

    更新日期:2003-01-01 00:00:00

  • The shielding design process--new plants to decommissioning.

    abstract::BNFL have over 25 years experience of designing nuclear plant for the whole-fuel cycle. In the UK, a Nuclear Decommissioning Authority (NDA) is to be set up to ensure that Britain's nuclear legacy is cleaned up safely, securely and cost effectively. The resulting challenges and opportunities for shielding design will ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nci171

    authors: Jeffries G,Cooper A,Hobson J

    更新日期:2005-01-01 00:00:00

  • MEASUREMENTS IN AFGHANISTAN USING AN ACTIVE RADON EXPOSURE METER AND ASSESSMENT OF RELATED ANNUAL EFFECTIVE DOSE.

    abstract::Radon gas concentrations in eight basements, four living rooms and four caves from different locations in Kabul and Panjsher, Afghanistan, were measured by using eight active radon exposure meters recently developed by the Helmholtz Center in Munich, Germany. The two-phase measurements lasted from a week to a year. In...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx086

    authors: Tanha MR,Vahlbruch JW,Riebe B,Irlinger J,Rühm W,Khalid FR,Storai A,Walther C

    更新日期:2018-01-01 00:00:00

  • Radiation doses in cerebral perfusion computed tomography: patient and phantom study.

    abstract::The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs260

    authors: Arandjic D,Bonutti F,Biasizzo E,Ciraj-Bjelac O,Floreani M,Giustizieri M,Iaiza F,Inkoom S,Tommasini G,Padovani R

    更新日期:2013-05-01 00:00:00

  • A Monte-Carlo code for the detailed simulation of electron and light-ion tracks in condensed matter.

    abstract::In an effort to understand the basic mechanism of the action of charged particles in solid radiation dosimeters, we extend our Monte-Carlo code (MC4) to condensed media (liquids/solids) and present new track-structure calculations for electrons and protons. Modeling the energy dissipation process is based on a model d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci671

    authors: Emfietzoglou D,Papamichael G,Karava K,Androulidakis I,Pathak A,Phillips GW,Moscovitch M,Kostarelos K

    更新日期:2006-01-01 00:00:00