ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

Abstract:

:Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in spent fuel pool, on the base of state of barriers which should prevent the release of radionuclides to the environment. The main task is to prepare outputs, which can be utilised for recommendation of protective measures. Measures include sheltering, iodine prophylaxis and evacuation inside the emergency planning zone and potentially beyond the zone. The paper summarizes approaches of ESTE, including dispersion models and reverse modeling approach applied for estimation of real release to the atmosphere of the environment. Compared are intervention levels implemented in ESTE for urgent measures in Slovakia, Czech Republic, Bulgaria, Iran and Austria.

journal_name

Radiat Prot Dosimetry

authors

Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

doi

10.1093/rpd/ncz226

subject

Has Abstract

pub_date

2019-12-31 00:00:00

pages

321-325

issue

2-3

eissn

0144-8420

issn

1742-3406

pii

5620704

journal_volume

186

pub_type

杂志文章
  • THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): AN INTRODUCTION TO THE DOCUMENTATION.

    abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx020

    authors: Napier BA

    更新日期:2017-11-01 00:00:00

  • Nuclear theory for high-energy nuclear reactions of biomedical relevance.

    abstract::A full description of all possible nuclear reactions that take place in a macroscopic device can only be accomplished with a nuclear model code in combination with key experimental data. To address this issue, the authors demonstrate some of the capabilities of TALYS, a nuclear reaction program which simulates nuclear...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm008

    authors: Koning AJ,Duijvestijn MC

    更新日期:2007-01-01 00:00:00

  • Dosimetric feature of natural biotite mineral.

    abstract::A thermoluminescence (TL) study relevant to radiation dosimetry has been carried out for X-ray irradiated biotite mineral under un-annealed and different annealed (473, 573, 673 and 773 K) conditions. Some significant variations in dosimetric characteristics have been observed with annealing treatment. Due to generati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu289

    authors: Kalita JM,Wary G

    更新日期:2015-04-01 00:00:00

  • Radiation effects in cultured tumour cells examined by 1H MRS: mobile lipids modulation and proliferative arrest.

    abstract::Much attention has been devoted in the past to monitor changes of mobile lipid (ML) (1)H MRS signals in spectra of tumour cells. The purpose of this work is to exploit ML signals to provide information on cell metabolism after irradiation, comparing tumour cells characterised by different radiosensitivity and relating...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl517

    authors: Grande S,Giovannini C,Luciani AM,Palma A,Rosi A,Sapora O,Viti V,Guidoni L

    更新日期:2006-01-01 00:00:00

  • Deformation luminescence produced during application and release of pressure on to gamma-irradiated CaF2:RE crystals.

    abstract::Calcium fluoride CaF2 is an interesting host lattice for rare earth (RE) activators. CaF2 crystals doped with different concentrations of Dy, Ce, Er and Gd have been grown by the Bridgman technique and their deformation luminescence (DL) induced by room temperature gamma irradiation has been recorded. When a uniaxial ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci606

    authors: Kher RS,Brahme N,Banerjee M,Dhoble SJ,Khokhar MS

    更新日期:2006-01-01 00:00:00

  • Optical bleaching, TSL and OSL features of CVD diamond.

    abstract::Luminescence and optical features of chemical vapour deposition (CVD) diamond have been studied in view of the potential application of this material in ionising radiation dosimetry field. For this purpose, thermally stimulated luminescence (TSL) and optically stimulated luminescence (OSL) techniques have been used. A...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci596

    authors: Benabdesselam M,Iacconi P,Trinkler L,Berzina B,Butler JE

    更新日期:2006-01-01 00:00:00

  • Suggested diagnostic reference levels for paediatric X-ray examinations in India.

    abstract::Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq458

    authors: Sonawane AU,Sunil Kumar JV,Singh M,Pradhan AS

    更新日期:2011-11-01 00:00:00

  • LEAD COMPOSITE VS. NONLEAD PROTECTIVE GARMENTS: WHICH ARE BETTER? A MULTIVENDOR COMPARISON.

    abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw373

    authors: Peters SMB,Zweers D,de Lange F,Mourik JEM

    更新日期:2017-08-01 00:00:00

  • Evaluation Of Organ Dose Based On Patient Data In East Asian Descent Pediatric Head Ct Examinations.

    abstract::The purpose of this study was to investigate other indices estimating absorbed dose for eye lens and brain, using clinical images of East Asian pediatric patients. We simulated head computed tomography (CT ) examinations in 104 pediatric patients. Effective diameter (deff) and water equivalent diameter (dw) were measu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa200

    authors: Kawamoto K,Fukushima Y,Matsuda A,Nakata M

    更新日期:2020-12-17 00:00:00

  • EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE.

    abstract::This paper compares several methods for estimation of the effective indoor dose of gamma radiation from building materials. It was found that specific dose ratios proposed for 3 cm thick layers in one recommendation gives 2.8 times lower value of gamma dose than other methods. The most common case is that granite has ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa125

    authors: Krmar M,Milić K,Arsenić I,Hansman J

    更新日期:2020-10-16 00:00:00

  • Indoor concentration of radon, thoron and their progeny around granite regions in the state of Karnataka, India.

    abstract::An extensive studies on the indoor activity concentrations of thoron, radon and their progeny in the granite region in the state of Karnataka, India, has been carried out since, 2007 in the scope of a lung cancer epidemiological study using solid-state nuclear track detector-based double-chamber dosemeters (LR-115, ty...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct243

    authors: Sannappa J,Ningappa C

    更新日期:2014-03-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • Evaluation of risk of deterministic effects in fluoroscopically guided procedures.

    abstract::A methodology for the evaluation of skin dose distribution and possible skin injuries on patients undergoing interventional procedures has been developed as part of the European DIMOND programme. Relevant dosimetric data from the procedures are recorded and other specific measurements for skin dose evaluation (slow fi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci714

    authors: Vano E,Gonzalez L,Guibelalde E,Aviles P,Fernandez JM,Prieto C,Galvan C

    更新日期:2005-01-01 00:00:00

  • Assessment of natural radioactivity concentrations and gamma dose rate levels in Kayseri, Turkey.

    abstract::This study assesses the level of background radiation for Kayseri province of Turkey. Natural radionuclide activity concentrations in soil samples were determined using high-resolution gamma spectroscopy. Outdoor gamma dose measurements in air at 1 m above ground level were determined using a portable gamma scintillat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr023

    authors: Otansev P,Karahan G,Kam E,Barut I,Taskin H

    更新日期:2012-01-01 00:00:00

  • Calibration measurements and standards for radiation protection dosimetry.

    abstract::The safe use of ionising radiation for applications in medicine, electric power production and industrial processes requires accurate measurements that are traceable to national standards. Radiological calibration laboratories provide measurements that may be used to determine the calibration coefficients for personal...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nch308

    authors: McDonald JC

    更新日期:2004-01-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • Assessment of occupational exposure to uranium by indirect methods needs information on natural background variations.

    abstract::Urine monitoring is the preferred method to determine exposure to soluble compounds of uranium in workplaces. The interpretation of uranium contents in workers bioassay samples requires knowledge on uranium excretion and its dependence on intake by diet. Exceptionally high concentrations of natural uranium in private ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm155

    authors: Muikku M,Heikkinen T,Puhakainen M,Rahola T,Salonen L

    更新日期:2007-01-01 00:00:00

  • Measurements of radon concentrations in waters and soil gas of Zonguldak, Turkey.

    abstract::The radon concentrations in soil-gas and water samples (in the form of springs, catchment, tap, thermal) used as drinking water or thermal were measured using a professional radon monitor AlphaGUARD PQ 2000PRO. The measured radon concentrations in water samples ranged from 0.32 to 88.22 Bq l(-1). Most of radon levels ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct308

    authors: Koray A,Akkaya G,Kahraman A,Kaynak G

    更新日期:2014-12-01 00:00:00

  • Blood tritium level as an estimate of soft tissue dose.

    abstract::To test the blood tritium level as an estimate of free water tritium (FWT) and organically bound tritium (OBT) in human soft tissues, a tritiated amino acid mixture (TAA) and tritiated water (HTO) were injected or orally administered to mice. Relatively high tritium retention in the blood was found after TAA injection...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006272

    authors: Saito M

    更新日期:2003-01-01 00:00:00

  • Overview of physical and biophysical techniques for accident dosimetry.

    abstract::From feedback experience from recent radiation accident cases, in addition to biological dosimetry and physical dosimetry based on Monte Carlo calculations or experimental means, there is a need for complementary methods of dosimetry for radiation accident. Electron paramagnetic resonance (EPR) spectrometry on bones o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncq341

    authors: Trompier F,Bassinet C,Della Monaca S,Romanyukha A,Reyes R,Clairand I

    更新日期:2011-03-01 00:00:00

  • A micro-gap, air-filled ionisation chamber as a detector for criticality accident dosimetry.

    abstract::A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct323

    authors: Murawski Ł,Zielczyński M,Golnik N,Gryziński MA

    更新日期:2014-10-01 00:00:00

  • Dose assessment for ingestion of a 330 kilobecquerel 60Co hot particle.

    abstract::On leaving the irradiated fuel bay at Pickering A nuclear power station, a worker triggered a whole body monitor alarm with activity in or on his head, and despite careful decontamination techniques he subsequently swallowed a hot particle. Over the next 3 d, the radioactivity was tracked through the body. It was then...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm256

    authors: Whillans DW,Chase WJ,Wolodarsky WH

    更新日期:2007-01-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra for radiobiology studies.

    abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006532

    authors: Pattison JE,Hugtenburg RP,Charles MW,Beddoe AH

    更新日期:2001-01-01 00:00:00

  • Optically stimulated luminescent glass optical fibre dosemeter.

    abstract::An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005974

    authors: Huston AL,Justus BL,Falkenstein PL,Miller RW,Ning H,Altemus R

    更新日期:2002-01-01 00:00:00

  • The shielding design process--new plants to decommissioning.

    abstract::BNFL have over 25 years experience of designing nuclear plant for the whole-fuel cycle. In the UK, a Nuclear Decommissioning Authority (NDA) is to be set up to ensure that Britain's nuclear legacy is cleaned up safely, securely and cost effectively. The resulting challenges and opportunities for shielding design will ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/nci171

    authors: Jeffries G,Cooper A,Hobson J

    更新日期:2005-01-01 00:00:00

  • Radon measurements in the caves of Zonguldak (Turkey).

    abstract::There are approximately 20 caves of limestone origin in Zonguldak (Turkey). In this study, the results of atmospheric radon measurements performed for two caves are presented. These caves, Gökgöl and Cehennemağzi, are open to tourism. Gökgöl Cave is the longer, at nearly 3,200 m in length. Cehenennemağzi is a pit-type...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci326

    authors: Aytekin H,Baldik R,Celebi N,Ataksor B,Tasdelen M,Kopuz G

    更新日期:2006-01-01 00:00:00

  • Radon in private drinking water wells.

    abstract::At least 10% of inhabitants in the Czech Republic are supplied with water from private sources (private wells, boreholes). With the increasing cost of water, the number of people using their own sources of drinking water will be likely to increase. According to the Decree of the State Office for Nuclear Safety about t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu095

    authors: Otahal P,Merta J,Burian I

    更新日期:2014-07-01 00:00:00

  • The genetics of radiation-induced osteosarcoma.

    abstract::Individual genetic variation can influence susceptibility to the carcinogenic effects of many environmental carcinogens. In radiation-exposed populations those individuals with a greater genetically determined susceptibility would be at greater risk of developing cancer. To include this modification of risk into radia...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006778

    authors: Rosemann M,Kuosaite V,Nathrath M,Atkinson MJ

    更新日期:2002-01-01 00:00:00

  • LUMBAR SPINE RADIOGRAPHY: LOWER ORGAN DOSE WITH THE USE OF PA PROJECTION.

    abstract::The purpose of the research was to determine the effect of the posteroanterior (PA) patient position in lumbar spine imaging on effective dose and the absorbed organ dose. The study was performed on 100 patients that were referred to the lumbar spine radiography that were divided into two equal groups of 50. Body Mass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz057

    authors: Alukić E,Mekiš N

    更新日期:2019-12-31 00:00:00

  • Protocols for dosimetry and patient reference levels.

    abstract::Doses in radiology should be as low as reasonably achievable. In order to compare practice in different centres it is necessary to compare patient doses. This can only be undertaken if dosimetry studies are similar. In order to facilitate comparisons, the DIMOND consortium developed a patient dosimetry protocol. Refer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci715

    authors: Faulkner K

    更新日期:2005-01-01 00:00:00