International intercomparison of measuring instruments for radon/thoron gas and radon short-lived daughter products in the NRPI Prague.

Abstract:

:During the 7th European Conference on Protection Against Radon at Home and at Work held in the autumn of 2013 in Prague, the second intercomparison of measuring instruments for radon and its short-lived decay products and the first intercomparison of radon/thoron gas discriminative passive detectors in mix field of radon/thoron were organised by and held at the Natural Radiation Division of the National Radiation Protection Institute (NRPI) in Prague. In total, 14 laboratories from 11 different countries took part in the 2013 NRPI intercomparison. They submitted both continuous monitors for the measurement of radon gas and equivalent equilibrium radon concentration in a big NRPI chamber (48 m3) and sets of passive detectors including radon/thoron discriminative for the measurement of radon gas in the big chamber and thoron gas in a small thoron chamber (150 dm3).

journal_name

Radiat Prot Dosimetry

authors

Jílek K,Hýža M,Kotík L,Thomas J,Tomášek L

doi

10.1093/rpd/ncu079

subject

Has Abstract

pub_date

2014-07-01 00:00:00

pages

154-9

issue

1-3

eissn

0144-8420

issn

1742-3406

pii

ncu079

journal_volume

160

pub_type

杂志文章
  • ESTIMATION OF ORGAN DOSES AMONG DIAGNOSTIC MEDICAL RADIATION WORKERS IN SOUTH KOREA.

    abstract::This study aimed to estimate the radiation organ doses from occupational exposure in 94 396 Korean medical radiation workers. Data on badge doses (i.e. personal dose equivalent at 10 mm) between 1996 and 2011 obtained from a national dosimetry registry, survey data from 2012 to 2013, and organ dose conversion coeffici...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx239

    authors: Choi Y,Shil Cha E,Jin Bang Y,Ko S,Ha M,Lee C,Jin Lee W

    更新日期:2018-04-01 00:00:00

  • Energy dependence of W values of protons in water.

    abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006798

    authors: Willems G,Back WY,Grosswendt B

    更新日期:2002-01-01 00:00:00

  • The neutron component of two high-energy photon reference fields.

    abstract::The 4.4 MeV photon reference field described in ISO 4037 is produced by the (12)C(p,p')(12)C (E(x) = 4.4389 MeV) reaction using a thick elemental carbon target and a proton beam with an energy of 5.7 MeV. The relative abundance of the isotope (13)C in elemental carbon is 1.10%. Therefore, the 4.4 MeV photon field is c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm083

    authors: Röttger S,Schäler K,Behrens R,Nolte R,Wissmann F

    更新日期:2007-01-01 00:00:00

  • Assessment of radiation doses to Australian participants in British nuclear tests.

    abstract::Between 1952 and 1957, the UK exploded a total of 12 nuclear devices in Australia, and also conducted about 600 'minor trials' that did not involve a nuclear explosion. Over 16 000 Australian servicemen and civilians were involved in the UK tests in Australia. This paper reports the estimation of doses that the Austra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp164

    authors: Crouch P,Robotham FR,Williams G,Wise K

    更新日期:2009-09-01 00:00:00

  • Radiation dose aspects in the handling of emerging nuclear fuels.

    abstract::The occupational annual dose levels, encountered at fabrication of emerging nuclear fuels, have been studied. Emerging fuels for the single and multiple recycling of Pu and MA have resulted in considerably higher gamma and neutron doses in comparison with commercial fuels. The occupational dose limit is exceeded at fa...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu016

    authors: Nicolaou G

    更新日期:2014-12-01 00:00:00

  • A follow-up study on indoor 222Rn, 220Rn their decay product concentrations in a mineralised zone of Himachal Pradesh, India.

    abstract::A follow-up study was taken up in a mineralised zone situated in Hamirpur district, Himachal Pradesh, India, to investigate high values of radon concentrations reported in past studies as well to update the old radon data based on bare SSNTD technique. In the present investigation, the concentrations of indoor radon, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv367

    authors: Bajwa BS,Singh P,Singh P,Saini K,Singh S,Sahoo BK,Sapra BK

    更新日期:2016-03-01 00:00:00

  • Collaboration of local government and experts responding to increase in environmental radiation level due to the nuclear disaster: focusing on their activities and latest radiological discussion.

    abstract::Activities were introduced in Kashiwa city in the Tokyo metropolitan area to correspond to the elevated environmental radiation level after the disaster of the Fukushima Daiichi nuclear power plant. These were based on a strong cooperation between local governments and experts. Ambient dose rate and radioactivity of f...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv279

    authors: Iimoto T,Nunokawa J,Fujii H,Takashima R,Hashimoto M,Fukuhara T,Yajima T,Matsuzawa H,Kurosawa K,Yanagawa Y,Someya S

    更新日期:2015-11-01 00:00:00

  • Contribution of indirect effects to clustered damage in DNA irradiated with protons.

    abstract::Protons are the dominant particles both in galactic cosmic rays and in solar particle events and, furthermore, proton irradiation becomes increasingly used in tumour treatment. It is believed that complex DNA damage is the determining factor for the consequent cellular response to radiation. DNA plasmid pBR322 was irr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv159

    authors: Pachnerová Brabcová K,Štěpán V,Karamitros M,Karabín M,Dostálek P,Incerti S,Davídková M,Sihver L

    更新日期:2015-09-01 00:00:00

  • NATURAL RADIATION EXPOSURE TO THE PUBLIC IN MINING AND ORE BEARING REGIONS OF CAMEROON.

    abstract::Within the framework of a joint research project on natural radiation exposure and its health effects in Cameroon from 2014 to 2017, the Institute of Geological and Mining Research and the Hirosaki University worked together to carry out natural radiation survey in mining and ore bearing regions of Cameroon. Air kerma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz176

    authors: Tokonami S,Hosoda M,Joseph Emmanuel NNI,Akata N,Flore TSY,Modibo OB,Samuel BG,Didier TSS

    更新日期:2019-10-01 00:00:00

  • Why can't we find a better biological indicator of dose?

    abstract::The three general principles of the International Commission on Radiological Protection (ICRP) are: justification, optimisation (ALARA) and dose limitation. The principle application of optimisation (ALARA) for occupational exposures of workers or the public to external radiation is reliant on low doses being assessed...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch094

    authors: Voisin P,Roy L,Benderitter M

    更新日期:2004-01-01 00:00:00

  • Neutron dose distribution at the GSI fragment separator.

    abstract::GSI is operating a facility for the production of rare isotopes. Nuclei are produced by fragmentation or fission of the impinging heavy ions with energies of approximately 1 GeV per nucleon. The major part of the primary beam and the produced nuclei is deposited in the components of the Fragment Separator (FRS) and ge...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch210

    authors: Fehrenbacher G,Festag JG

    更新日期:2004-01-01 00:00:00

  • Neoplastic transformation of a human hybrid cell line by alpha particles in relation to mammography X rays.

    abstract::The hybrid cell line CGL1 is the only cell line which allows quantitation of neoplastic transformation in human cells. Hybrid cells were exposed to 3.4 MeV alpha particles or to mammography X rays (29 kV(p)) and both survival and neoplastic cell transformation were assayed. For comparison, previously published data ob...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl457

    authors: Frankenberg-Schwager M,Spieren S,Pralle E,Frankenberg D

    更新日期:2006-01-01 00:00:00

  • Organisation and delivery of imaging services: the contributions of ethics and political economy.

    abstract::The objective of this discussion is to explore how theories from other disciplines can contribute to the debate on organisation and delivery of diagnostic and therapeutic exposures. The first part explores how theories of justice suggest that health services should be provided; the second part explores how stakeholder...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp043

    authors: Durand-Zaleski I

    更新日期:2009-07-01 00:00:00

  • Radiation-induced non-targeted effects: some open questions.

    abstract::The existence of non-targeted effects (NTEs) of radiation (genomic instability and bystander effects) has been generally accepted for >20 y; however, there is research, which was largely ignored going back to 1915 reporting these effects. Despite today's general acceptance of the phenomenon of NTE, there is little agr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncv155

    authors: Mothersill C,Seymour C

    更新日期:2015-09-01 00:00:00

  • A SIMPLIFIED METHOD FOR THE WATER-EQUIVALENT DIAMETER CALCULATION TO ESTIMATE PATIENT DOSE IN CT EXAMINATIONS.

    abstract::We proposed and evaluated a water-equivalent diameter calculation without using a region of interest (ROI), (Dw,t) and compared it with the results of using a ROI fitted to the patient border (Dw,f). Evaluations were carried out on thoracic and head CT images. We found that the difference between Dw,t and Dw,f was wit...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy214

    authors: Anam C,Arif I,Haryanto F,Widita R,Lestari FP,Adi K,Dougherty G

    更新日期:2019-11-30 00:00:00

  • RADON EXHALATION FROM SOIL AND ITS DEPENDENCE FROM ENVIRONMENTAL PARAMETERS.

    abstract::An automatic measuring apparatus called exhalometer for measurement of the radon exhalation rate from soil is introduced. It consists of a pneumatic driven accumulation chamber with an open bottom, a PC-based control system, six Lucas cells for radon measurement and sensors for environmental parameters. It allows movi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx165

    authors: Yang J,Buchsteiner M,Salvamoser J,Irlinger J,Guo Q,Tschiersch J

    更新日期:2017-11-01 00:00:00

  • IMPORTANCE OF ENGAGING IN DIALOGUE WITH THE POPULATION AFTER A NUCLEAR ACCIDENT.

    abstract::Human behaviour is primarily driven by perceptions and this is particularly important in the aftermath of a nuclear accident. One of the main lessons we can draw from the Chernobyl and Fukushima accidents is that once the acute phase of the accident is over, it is important to engage in dialogue with the affected popu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw320

    authors: Vanmarcke H

    更新日期:2017-04-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • Background radiation and individual dosimetry in the costal area of Tamil Nadu, India.

    abstract::South coast of India is known as the high-level background radiation area (HBRA) mainly due to beach sands that contain natural radionuclides as components of the mineral monazite. The rich deposit of monazite is unevenly distributed along the coastal belt of Tamil Nadu and Kerala. An HBRA site that laid in 2×7 m alon...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr179

    authors: Matsuda N,Brahmanandhan GM,Yoshida M,Takamura N,Suyama A,Koguchi Y,Juto N,Raj YL,Winsley G,Selvasekarapandian S

    更新日期:2011-07-01 00:00:00

  • Comparison of results from quality control of physical parameters and results from clinical evaluation of mammographic images for the mammography screening facilities in Poland.

    abstract::The material for this study comprised control protocols from 248 mammography screening facilities, prepared by physicists employed at 16 Regional Coordinating Centres and the results from the clinical evaluation of mammographic images in 248 facilities in Poland. All mammograms were evaluated independently by three ex...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncr321

    authors: Fabiszewska E,Grabska I,Jankowska K,Wesolowska E,Bulski W

    更新日期:2011-09-01 00:00:00

  • Magnetic field tracking with MCNP5.

    abstract::With the introduction of continuous-energy heavy charged particle transport in MCNP5, the need for tracking charged particles in a magnetic field becomes increasingly important. Two methods for including magnetic field effects on charged particles are included in the proton transport version of the code. The first tec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci048

    authors: Bul JS,Hughes HG,Walstrom PL,Zumbro JD,Mokhov NV

    更新日期:2005-01-01 00:00:00

  • CT dosimetry: getting the best from the adult Cristy phantom.

    abstract::The use of geometrical phantoms for computed tomography (CT) dosimetry can incur errors in the calculation of effective dose due to the anatomically incorrect organ shapes and distributions, and unrepresentative body dimensions. A Monte Carlo program that makes use of an anatomically correct voxel phantom has been dev...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch521

    authors: Castellano IA,Dance DR,Evans PM

    更新日期:2005-01-01 00:00:00

  • STUDY OF DOSES TO HIPPOCAMPUS OF INTERVENTIONAL CARDIOLOGISTS AND THEIR IMPLICATION FOR DOSIMETRIC MONITORING.

    abstract::Dosimetric monitoring and protection of the personnel involved into interventional procedures is one of the key issues nowadays, yet doses received by their brains were left without rigorous consideration so far. The paper is the fast track of the results of the pilot study of possible magnitude of operator's doses wi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw091

    authors: Chumak V,Morgun A,Bakhanova E,Voloskyi V

    更新日期:2016-09-01 00:00:00

  • Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032854

    authors: Vana N,Schoner W,Noll M,Fugger M,Akatov Y,Shurshakov V

    更新日期:1999-01-01 00:00:00

  • Influence of the uniformity of the slab phantom illumination on the calibration of personal dosemeters.

    abstract::For the calibration of personal dosemeters in terms of H(p)(10), the ISO water slab phantom shall be used. The irradiation geometry must be chosen such that the field diameter at the phantom front surface is large enough to irradiate the phantom completely and, in addition, homogeneously. However, in practice it is no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq036

    authors: Ankerhold U,Ambrosi P

    更新日期:2010-06-01 00:00:00

  • Assessing The Risk Associated with Simultaneous Exposure To Mobile Communication Signals Within 900-2500 MHz in Nigeria.

    abstract::In this study, the total exposure due to signals within GSM 900, GSM 1800, CDMA-1900 and 3G-2100 frequency bands at 200 m from the foot of 120, 100 and 80 base station masts in the Nigerian cities of Lagos, Ibadan and Abuja, respectively, was assessed. A calibrated hand-held spectrum analyser was used to measure the l...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa203

    authors: Ayinmode BO,Farai IP

    更新日期:2020-12-31 00:00:00

  • Modelling of composite neutron scintillators.

    abstract::Composite neutron scintillators consisting of neutron-insensitive fluorescent dopant particles (e.g. ZnS:Ag) embedded in a matrix material containing isotopes with high neutron cross sections that emit energetic charged particles (e.g. 6Li) are a popular method for neutron detection in a variety of applications. The s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci121

    authors: Stephan AC,Dai S,Wallace SA,Miller LF

    更新日期:2005-01-01 00:00:00

  • Radiation Protection Studies for Medical Particle Accelerators using Fluka Monte Carlo Code.

    abstract::Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw302

    authors: Infantino A,Cicoria G,Lucconi G,Pancaldi D,Vichi S,Zagni F,Mostacci D,Marengo M

    更新日期:2017-04-01 00:00:00

  • Discrimination between natural and other gamma ray sources from environmental gamma ray dose rate monitoring data.

    abstract::In this study, a method to discriminate between natural and other γ-ray sources from environmental γ-ray dose rate monitoring data was developed, and it was successfully applied to actual monitoring data around nuclear facilities. The environmental dose rate is generally monitored by NaI(Tl) detector systems in the lo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv265

    authors: Kumagai K,Ookubo H,Kimura H

    更新日期:2015-11-01 00:00:00

  • Development and validation of a technique for the determination of 226Ra and 228Ra by liquid scintillation in liquid samples.

    abstract::Radium isotopes are dispersed in the environment according to their physicochemical characteristics. Considering their long half-lives and radiological effects, (226)Ra and (228)Ra are very important issues in radiological protection. In Brazil, radium isotopes represent an exposure problem both in nuclear fuel cycle ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq434

    authors: Fernandes PC,Sousa WO,Julião LM,Dantas BM

    更新日期:2011-03-01 00:00:00