Neutron dose distribution at the GSI fragment separator.

Abstract:

:GSI is operating a facility for the production of rare isotopes. Nuclei are produced by fragmentation or fission of the impinging heavy ions with energies of approximately 1 GeV per nucleon. The major part of the primary beam and the produced nuclei is deposited in the components of the Fragment Separator (FRS) and generates neutron radiation. Thermoluminescence dosemeters (TLDs) (6LiF/7LiF pairs in PE spheres) were exposed in neutron fields produced by uranium beams with energies between 100 and 1000 MeV per nucleon during an irradiation period in the year 2002. Two-dimensional dose distributions are obtained using these TL measurements in combination with model calculations. The applied model describes the dose distribution as a superposition of dose patterns of 20 single sources equally distributed along the FRS. The single source distribution is based on a measured double differential neutron distribution for a 1 GeV per nucleon uranium beam.

journal_name

Radiat Prot Dosimetry

authors

Fehrenbacher G,Festag JG

doi

10.1093/rpd/nch210

keywords:

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

739-42

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

110/1-4/739

journal_volume

110

pub_type

杂志文章
  • Optically stimulated luminescence signals of polymineral fine grains in the JSC Mars-1 soil simulant sample.

    abstract::The results of various experiments which characterise the optically stimulated luminescence (OSL) signals from polymineral fine grains of a Martian soil simulant sample (JSC Mars-1) are presented. The blue-green stimulated luminescence signal has greater thermal stability than the infrared stimulated luminescence sign...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005994

    authors: Banerjee D,Blair M,Lepper K,McKeever SW

    更新日期:2002-01-01 00:00:00

  • Radiation dose to premature new-borns in the Belgian neonatal intensive care units.

    abstract::In the neonatal intensive care units (NICU), premature new-borns may be exposed to important doses. Because of their increased radiosensitivity and longer life expectancy, dose optimisation is of importance. The present study aimed at evaluating the dose of the most common radiographs in the Belgian NICU. Entrance sur...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct184

    authors: Dabin J,Struelens L,Vanhavere F

    更新日期:2014-01-01 00:00:00

  • Radiation exposure to the population of Europe following the Chernobyl accident.

    abstract::On the occasion of the 20th anniversary of the Chernobyl accident an attempt has been made to evaluate the impact of the Chernobyl accident on the global burden of human cancer in Europe. This required the estimation of radiation doses in each of the 40 European countries. Dose estimation was based on the analysis and...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl528

    authors: Drozdovitch V,Bouville A,Chobanova N,Filistovic V,Ilus T,Kovacic M,Malátová I,Moser M,Nedveckaite T,Völkle H,Cardis E

    更新日期:2007-01-01 00:00:00

  • ISO 4037:2019 VALIDATION OF RADIATION QUALITIES BY MEANS OF HALF-VALUE LAYER AND HP(10) DOSIMETRY.

    abstract::Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updated ISO 4037:2019 standard. As the ISO 4037 contains a somewhat vague d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz185

    authors: Bandalo V,Greiter MB,Brönner J,Hoedlmoser H

    更新日期:2019-12-31 00:00:00

  • Feminist theoretical perspectives on ethics in radiology.

    abstract::The substantive safety of radiological and other medical procedures can be radically reduced by unconscious factors governing scientific thought. In addition, the historical exclusion of women from these disciplines has possibly skewed their development in directions that now need to be addressed. This paper focuses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp055

    authors: Condren M

    更新日期:2009-07-01 00:00:00

  • Novel developments in the MOSFET dosemeter for neutron dosimetry applications.

    abstract::The feasibility of large-geometry Metal Oxide Semiconductor Field Effect Transistor (MOSFET) devices has been assessed for both active and passive neutron dosimetry and use in radiotherapy environments. Neutron sensitivity has been enhanced with the use of polymeric cement surrounding the gate region. Neutron activati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch202

    authors: Price RA,Benson C,Joyce MJ,Kestell DJ,Silvie J

    更新日期:2004-01-01 00:00:00

  • An improved method for Organic Bound Tritium (OBT) determination in urine samples.

    abstract::The Organic Bound Tritium (OBT) amount in the body may induce changes in the evaluation of the internal exposure to tritium, due to its different retention time relative to HTO. OBT measurements for urine are not performed routinely, mainly because of the lengthy work needed in preparation of the samples, when using t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm148

    authors: Gonen R,Marco R,German U,Katorza E,Alfassi ZB,Haquin G,Tshuva A,Pelled O

    更新日期:2007-01-01 00:00:00

  • Nuclear reactions in Monte Carlo codes.

    abstract::The physics foundations of hadronic interactions as implemented in most Monte Carlo codes are presented together with a few practical examples. The description of the relevant physics is presented schematically split into the major steps in order to stress the different approaches required for the full understanding o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006788

    authors: Ferrari A,Sala PR

    更新日期:2002-01-01 00:00:00

  • Validation of efficiency tracing and zero detection threshold techniques using liquid scintillation analyser TriCarb.

    abstract::Efficiency tracing with unquenched 14C and zero detection threshold with unquenched 3H as tracers are practical and simple techniques which have been implemented to quantify the activity of various beta emitters using liquid scintillation analyser. These techniques are used to study the influence of quench level on ac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq495

    authors: Reddy PJ,Bhade SP,Babu DA,Sharma DN

    更新日期:2011-11-01 00:00:00

  • EXPERIMENTAL EVALUATION OF NEUTRON SHIELDING MATERIALS.

    abstract::A new proposed design of neutron shielding material-based on the commercial material Borotron UH050 with an addition of Al(OH)3-is evaluated in order to determine if its neutron and gamma shielding properties match those of a reference material, NS4FR. Neutron and gamma dosimetry measurements are performed, as well as...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx202

    authors: Campo X,Méndez R,Lacerda MAS,Garrido D,Embid M,Sanz J

    更新日期:2018-08-01 00:00:00

  • Biokinetics of radionuclides and treatment of accidental intakes.

    abstract::This paper describes the objectives and reviews the progress of EULEP Working Party 5, convened under the auspices of the European Union's Fifth Framework Programme, to 'cluster' two EU-supported contracts, Biokinetics and Dosimetry of Internal Contamination (BIODOS (EU Contract FIS5-1999-00214)) and Radionuclide Biok...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006318

    authors: Taylor DM,Stradling GN,Ménétrier F

    更新日期:2003-01-01 00:00:00

  • Methodology for Simple Spot Measurement of Equilibrium Equivalent Radon Concentration.

    abstract::Estimation of the effective inhalation dose of short half-life radon progeny requires the quantification of radon equilibrium equivalent activity concentrations (EEC, Ceq). The aim of the present study is to develop new methodology that focuses on spot measurements to determine EEC from single gross alpha counts and d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa176

    authors: Sakoda A,Ishimori Y,Kanzaki N,Tanaka H

    更新日期:2020-11-13 00:00:00

  • 30-y follow-up of a Pu/Am inhalation case.

    abstract::In 1983, a young man inhaled accidentally a large amount of plutonium and americium. This case was carefully followed until 2013. Since no decorporation measures had been taken, the undisturbed metabolism of Pu and Am can be derived from the data. First objective was to determine the amount of inhaled radionuclides an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu342

    authors: Wernli C,Eikenberg J,Marzocchi O,Breustedt B,Oestreicher U,Romm H,Gregoratto D,Marsh J

    更新日期:2015-04-01 00:00:00

  • Assessment of doses and risk due to natural radionuclides in edible biota of Domiasiat, Meghalaya.

    abstract::A radiation dose assessment exercise was carried out for the edible biota Solanum nigrum, Carica papaya, Raphnus sativum and Phaseolus domesticus due to naturally available radionuclides (40)K, (238)U and (232)Th in the Domiasiat area in Meghalaya, India. The concentration of radionuclides in biota and corresponding s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr435

    authors: Kumar N,Chaturvedi SS,Jha SK

    更新日期:2012-07-01 00:00:00

  • Practical application of the ICRP Human Respiratory Tract Model.

    abstract::The ICRP Publication 66 Human Respiratory Tract Model (HRTM) has been applied to calculate dose coefficients and bioassay functions using default values of parameters relating to the material and the subjects. The ICRP Task Group on Internal Dosimetry (INDOS) has developed a guidance document on application of the HRT...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006324

    authors: Bailey MR,Ansoborlo E,Guilmette RA,Paquet F

    更新日期:2003-01-01 00:00:00

  • AUTOMATIC BRAIN DOSE ESTIMATION IN COMPUTED TOMOGRAPHY USING PATIENT DICOM IMAGES.

    abstract::This study aims to develop an Automatic Brain Dose Estimation (ABDE) methodology for head computed tomography examinations. The ABDE is to be applied first to an anthropomorphic Alderson phantom to obtain a Correction factor (Cf) between the ABDE and the direct absorbed brain dose using dosemeters positioned within th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa006

    authors: Gharbi S,Labidi S,Mars M

    更新日期:2020-07-02 00:00:00

  • Environmental gamma dosimetry with OSL of alpha-Al(2)O(3):C for in situ sediment measurements.

    abstract::The physical properties of alpha-Al(2)O(3):C are very similar to that of quartz, which make it an attractive dosimetric material for geological and archaeological dating applications. Storage experiments in an ultra-low-radiation underground environment (UDO at PTB) and gamma-ray spectrometry show that the optically s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq146

    authors: Richter D,Dombrowski H,Neumaier S,Guibert P,Zink AC

    更新日期:2010-09-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00

  • TOWARDS A PERSONALISED AND INTERACTIVE ASSESSMENT OF OCCUPATIONAL EXPOSURE TO MAGNETIC FIELD DURING DAILY ROUTINE IN MAGNETIC RESONANCE.

    abstract::Magnetic resonance imaging (MRI) is one of the most common sources of electromagnetic (EM) fields as a diagnostic technique widely used in medicine. MRI staff during the working day is constantly exposed to static and spatially heterogeneous magnetic field. Also, moving around the MRI room to perform their functions, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy114

    authors: Hartwig V,Virgili G,Ferrante Vero LF,De Marchi D,Landini L,Giovannetti G

    更新日期:2018-12-01 00:00:00

  • Quality control and reliability of reported doses.

    abstract::Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch287

    authors: Stadtmann H,Figel M,Kamenopoulou V,Kluszczynski D,Roed H,Van Dijk J

    更新日期:2004-01-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra for radiobiology studies.

    abstract::Improved radiation protection of humans requires a better understanding of the mechanisms of radiation action and accurate estimates of radiation risk for both internal and external radiations. The Japanese atomic bomb survivors represent one of the most important sources of human data on the late carcinogenic effects...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006532

    authors: Pattison JE,Hugtenburg RP,Charles MW,Beddoe AH

    更新日期:2001-01-01 00:00:00

  • Hardness ratios of different neutron spectra.

    abstract::Extensive data have been gathered in the past on the response of different detectors, based on the registration of neutron-induced fissions in bismuth, gold, tantalum and thorium by the spark-replica counter and the thin film breakdown counter. These detectors make it possible to exploit the excellent characteristics ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch168

    authors: Tommasino L,Tripathy SP

    更新日期:2004-01-01 00:00:00

  • Track structure for low energy ions including charge exchange processes.

    abstract::The model and development is described of a new generation of Monte Carlo track structure codes. The code LEPHIST simulates full slowing down of low-energy proton history tracks in the range 1 keV-1 MeV and the code LEAHIST simulates low-energy alpha particle history tracks in the range 1 keV-8 MeV in water. All prima...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006838

    authors: Uehara S,Nikjoo H

    更新日期:2002-01-01 00:00:00

  • A minimally invasive method to evaluate 131I kinetics in blood.

    abstract::The dose limiting factor for 131I therapy in patients with thyroid cancer is myelotoxicity, thus an accurate determination of radioiodine activity in the red marrow is of paramount importance. The reference method for red marrow dosimetry in radiometabolic therapy is based on the measurement of radioiodine kinetics, p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch041

    authors: Traino AC,Di Martino F,Boni G,Mariani G,Lazzeri M

    更新日期:2004-01-01 00:00:00

  • OCCUPATIONAL EXPOSURE TO RADON IN DIFFERENT KINDS OF NON-URANIUM MINES.

    abstract::For more accurate assessments of the occupational exposure to radon for miners, the individual monitoring was conducted by using an improved passive integrating (222)Rn monitor. A total of 120 miners in 3 different kinds of mines were monitored throughout a year. The results showed that the individual exposure to rado...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw026

    authors: Fan D,Zhuo W,Zhang Y

    更新日期:2016-09-01 00:00:00

  • Exposures from nuclear medicine diagnostic procedures: the dose impact on the Aosta Valley population.

    abstract::The present work evaluates the per-procedure, annual collective and per-capita effective doses to the Aosta Valley region population from nuclear medicine (NM) examinations performed from 2005 to 2011 at the regional NM department. Based on its demographical and socioeconomics characteristics, this area can be conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct158

    authors: Aimonetto S,Arrichiello C,Peruzzo Cornetto A,Catuzzo P,Zeverino M,Poti C,Meloni T,Pasquino M,Tofani S

    更新日期:2013-12-01 00:00:00

  • The genetics of radiation-induced osteosarcoma.

    abstract::Individual genetic variation can influence susceptibility to the carcinogenic effects of many environmental carcinogens. In radiation-exposed populations those individuals with a greater genetically determined susceptibility would be at greater risk of developing cancer. To include this modification of risk into radia...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006778

    authors: Rosemann M,Kuosaite V,Nathrath M,Atkinson MJ

    更新日期:2002-01-01 00:00:00

  • Early effects comparison of X-rays delivered at high-dose-rate pulses by a plasma focus device and at low dose rate on human tumour cells.

    abstract::A comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT). Experiments have been performed at 0.5 and 2 Gy doses o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv163

    authors: Virelli A,Zironi I,Pasi F,Ceccolini E,Nano R,Facoetti A,Gavoçi E,Fiore MR,Rocchi F,Mostacci D,Cucchi G,Castellani G,Sumini M,Orecchia R

    更新日期:2015-09-01 00:00:00

  • Occupational radiation protection of health workers in imaging.

    abstract::Occupational radiological protection (RP) is still a challenge in several clinical practices. ICRP has included specific recommendations and advice for occupational protection in most of the documents published in recent years and its current programme of work includes the preparation of documents with specific conten...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu354

    authors: Vano E

    更新日期:2015-04-01 00:00:00

  • AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    abstract::The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch185

    authors: Gressier V,Guerre-Chaley JF,Lacoste V,Lebreton L,Pelcot G,Pochat JL,Bolognese-Milstajn T,Champion D