Environmental gamma dosimetry with OSL of alpha-Al(2)O(3):C for in situ sediment measurements.

Abstract:

:The physical properties of alpha-Al(2)O(3):C are very similar to that of quartz, which make it an attractive dosimetric material for geological and archaeological dating applications. Storage experiments in an ultra-low-radiation underground environment (UDO at PTB) and gamma-ray spectrometry show that the optically stimulated luminescence (OSL) signal of this material does neither suffer from a significant inherent background caused by traces of radionuclides (<6 microGy a(-1)) nor from fading. After having performed a simple calibration procedure, gamma dosimetry based on alpha-Al(2)O(3):C detectors, which were exposed in a brick block and a lead castle for different periods of time, provided concordant results with dose values derived from independent gamma-ray spectrometric measurements using high-purity germanium and NaI:Tl detectors. These investigations indirectly confirm both the absence of a significant inherent background and fading of the detector material. Small doses of a few micro gray accumulated in short exposure times to environmental radiation can be accurately measured, even when doses (i.e. transport dose) much larger than the actual environmental dose have to be subtracted. It is shown that the OSL signal caused by small transport doses can be easily and reproducibly reset even under difficult field conditions by illuminating the dosemeters with the blue light from Luxeon LEDs. Summarised, alpha-Al(2)O(3):C appears to be the material of choice for dosimetric dating applications of quartz or related materials, when analysed by using OSL.

journal_name

Radiat Prot Dosimetry

authors

Richter D,Dombrowski H,Neumaier S,Guibert P,Zink AC

doi

10.1093/rpd/ncq146

subject

Has Abstract

pub_date

2010-09-01 00:00:00

pages

27-35

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncq146

journal_volume

141

pub_type

杂志文章
  • Filter, collimator and moderating material to achieve boron neutron capture enhanced fast neutron therapy.

    abstract::The combination of fast neutron therapy and boron neutron capture therapy is currently being studied as a possible treatment for some radio-resistant brain tumours. In an attempt to design a boron-enhanced fast neutron therapy beam for the Fermilab Fast Neutron Therapy Facility, the use of moderating material surround...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci256

    authors: Sweezy J,Hertel N,Lennox A

    更新日期:2005-01-01 00:00:00

  • No evidence for a low linear energy transfer adaptive response in irradiated RKO cells.

    abstract::It has become increasingly evident from reports in the literature that there are many confounding factors capable of modulating radiation-induced non-targeted responses, such as the bystander effect and the adaptive response. In this paper, we examine recent data which suggest that the observation of non-targeted resp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq487

    authors: Sowa MB,Goetz W,Baulch JE,Lewis AJ,Morgan WF

    更新日期:2011-02-01 00:00:00

  • Effective dose assessment for workers in caves in the Czech Republic: experiments with passive radon detectors.

    abstract::The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN system consists of a plastic chamber that is conically cylindrical in shape and about 0.5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn118

    authors: Thinová L,Burian I

    更新日期:2008-01-01 00:00:00

  • THE MAYAK WORKER DOSIMETRY SYSTEM-2013 (MWDS-2013): PHASE II-QUALITY ASSURANCE OF ORGAN DOSE CALCULATIONS.

    abstract::In order to check developed software tools, it was necessary to compare estimates of statistical characteristics of annual absorbed plutonium internal doses obtained by PANDORA and IMBA software with the same original data. The results were compared from dose calculations of five cases with different initial data on p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx085

    authors: Vostrotin VV,Birchall A,Zhdanov AV,Puncher M

    更新日期:2017-11-01 00:00:00

  • Experimental simulation of A-bomb gamma ray spectra: revisited.

    abstract::It has been reported recently that the A-bomb gamma ray spectra received by the colon of the average Japanese survivor of Hiroshima and Nagasaki may be experimentally simulated using a hospital-based Philips SL15 linear accelerator. The simulated A-bomb gamma radiation may be used in radiobiology experiments to determ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch320

    authors: Pattison JE,Payne LC,Hugtenburg RP,Beddoe AH,Charles MW

    更新日期:2004-01-01 00:00:00

  • Radiation exposure received by the medical radiation workers in Lithuania at the Institute of Oncology, Vilnius University, 2004-2011.

    abstract::The occupational radiation exposure of medical radiation workers at the Institute of Oncology, Vilnius University (IOVU) was analysed. Quartile dose measurements were collected and routinely analysed for a period of 8 y from 1 January 2004 to 31 December 2011. A total of 193 medical radiation workers were monitored, c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct111

    authors: Samerdokiene V,Atkocius V,Ofomala R

    更新日期:2013-11-01 00:00:00

  • Determination of 137Cs and 60Co pollution in the area of the Laguna Verde Nuclear Power Plant, Mexico.

    abstract::The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv250

    authors: Salas Mar B

    更新日期:2015-11-01 00:00:00

  • Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoring.

    abstract::In this paper, the results aimed at assessing the performance of two varieties of LiF detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) in photon fields relatively to reproducibility, detection threshold and angular dependence as defined in the ISO 12794 standard are presented. The fading properties and the limit of detection wer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq366

    authors: Freire LC,Pereira MF,Calado AM,Santos LM,Cardoso JV,Alves JG

    更新日期:2011-03-01 00:00:00

  • NATURAL RADIONUCLIDES IN AGRICULTURAL PLANTS FROM NORTHERN THAILAND.

    abstract::Thailand is predominantly an agricultural country. The Northern Region occupies the second largest cultivated land area in the country. To establish baseline data for future environmental monitoring, seventy-nine plant samples including vegetables, fruits and tobaccos and their relevant soils were collected from the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz081

    authors: Kritsananuwat R,Kranrod C,Chanyotha S,Ploykrathok T,Sriploy P

    更新日期:2019-10-01 00:00:00

  • NEURAL NETWORK MODELLING OF CARDIAC DOSE CONVERSION COEFFICIENT FOR ARBITRARY X-RAY SPECTRA.

    abstract::In this article, an approach to compute the dose conversion coefficients (DCCs) is described for the computational voxel phantom 'High-Definition Reference Korean-Man' (HDRK-Man) using artificial neural networks (ANN). For this purpose, the voxel phantom was implemented into the Monte Carlo (MC) transport toolkit GEAN...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv436

    authors: Kadri O,Manai K

    更新日期:2016-12-01 00:00:00

  • A TLD-based personal dosemeter system for aircrew monitoring.

    abstract::Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is ass...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch209

    authors: Hajek M,Berger T,Vana N

    更新日期:2004-01-01 00:00:00

  • PUBLIC HEALTH ENGLAND-CENTRE FOR RADIATION, CHEMICAL AND ENVIRONMENTAL HAZARDS (PHE-CRCE) EXTERNAL EXPERT EXPERIENCE IN THE JOINT EXTERNAL EVALUATION (JEE) MISSION FOR THE RADIATION EMERGENCIES TECHNICAL AREA.

    abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy142

    authors: de Ruvo A,Cox D

    更新日期:2018-12-01 00:00:00

  • Reference dosimetry for light-ion beams based on graphite calorimetry.

    abstract::Developments in hadron therapy require efforts to improve the accuracy of the dose delivered to a target volume. Here, the determination of the absorbed dose under reference conditions was analysed. Based on the International Atomic Energy Agency TRS-398 code of practice, for hadron beams, the combined standard uncert...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct299

    authors: Rossomme S,Palmans H,Thomas R,Lee N,Duane S,Bailey M,Shipley D,Bertrand D,Romano F,Cirrone P,Cuttone G,Vynckier S

    更新日期:2014-10-01 00:00:00

  • Indoor radon and thoron levels in Neendakara and Chavara regions of southern coastal Kerala, India.

    abstract::Some areas of the world, called high background radiation areas (HBRAs), have anomalously high levels of natural background radiation and the population residing in the areas is exposed to higher levels of radiation doses than other parts of the world where the natural radioactivity contents are normal. In the present...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr399

    authors: Pereira CE,Vaidyan VK,Chougaonkar MP,Mayya YS,Sahoo BK,Jojo PJ

    更新日期:2012-07-01 00:00:00

  • Radon in waterworks: dose assessment, analysis of influence parameters and improved methods of measurement.

    abstract::In Austria a comprehensive study on radiation exposure in waterworks was conducted. The aim of this study was to evaluate the risks for the affected employees. On the basis of geographical, geological and hydrological aspects, 21 waterworks were selected. A total of 85 passive short-term measurements and measurements ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu067

    authors: Michael S,Andreas B,Claudia S,Fabian R,Ringer W,Josef MF

    更新日期:2014-07-01 00:00:00

  • Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical X-ray imaging sensor.

    abstract::CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-dope...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci515

    authors: Kurata N,Kubota N,Takei Y,Nanto H

    更新日期:2006-01-01 00:00:00

  • Studies of patient doses in interventional radiological examinations.

    abstract::In Russia, especially in big cities like St. Petersburg, the annual number of interventional radiological (IR) examinations for both diagnostic and treatment purposes is increasing continuously. However, IR examinations might involve high patient doses and even the risk of skin injures that should be prevented. In thi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncq021

    authors: Sarycheva S,Golikov V,Kalnicky S

    更新日期:2010-04-01 00:00:00

  • Occupational radiation protection of health workers in imaging.

    abstract::Occupational radiological protection (RP) is still a challenge in several clinical practices. ICRP has included specific recommendations and advice for occupational protection in most of the documents published in recent years and its current programme of work includes the preparation of documents with specific conten...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu354

    authors: Vano E

    更新日期:2015-04-01 00:00:00

  • INITIAL EVALUATION OF INDIVIDUAL DOSES IN THE EARLY PHASE OF A NUCLEAR REACTOR ACCIDENT BASED ON IN-VIVO MONITORING DATA AND SIMULATED RADIOLOGICAL CONSEQUENCES.

    abstract::In the early phase of a nuclear reactor accident, in-vivo monitoring of impacted population would be highly useful to detect potential contamination during the passage of the cloud and to estimate the dose from inhalation of measured radionuclides. However, it would be important to take into account other exposure com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy277

    authors: Challeton-de Vathaire C,Quentric E,Didier D,Blanchardon E,Davesne E,Rannou A,Agarande M,Renaud-Salis V,Franck D

    更新日期:2019-11-30 00:00:00

  • Patient dosimetry in nuclear medicine.

    abstract::In diagnostic nuclear medicine, the biokinetics of the radiopharmaceutical (actually of the radionuclide) is determined for a number of representative patients. At therapy, it is essential to determine the patient's individual biokinetics of the radiopharmaceutical in order to calculate the absorbed doses to critical ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv061

    authors: Mattsson S

    更新日期:2015-07-01 00:00:00

  • Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    abstract::The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a032854

    authors: Vana N,Schoner W,Noll M,Fugger M,Akatov Y,Shurshakov V

    更新日期:1999-01-01 00:00:00

  • Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments.

    abstract::High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with (252)Cf neutron sources and are used in various wor...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu298

    authors: Lee KW,Sheu RJ

    更新日期:2015-04-01 00:00:00

  • A DISCUSSION ON ISSUES WITH RADON IN DRINKING WATER.

    abstract::The majority of the world's population relies on surface water or large public supply systems of groundwater, where radon is low and a guidance value for radon in drinking water is not necessary. However, the International Commission on Radiological Protection (ICRP) recently issued a dose coefficient for radon ingest...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz035

    authors: Chen J

    更新日期:2019-12-31 00:00:00

  • Would children be adequately protected by existing intervention levels during a radionuclear emergency?

    abstract::The question arises as to whether radiation standards and guidelines set for adults are sufficiently protective of children. To answer this question, published literature values have been used to calculate radiation doses to children and adults from external and internal exposure to a suite of 30 radionuclides commonl...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq202

    authors: Tracy BL

    更新日期:2010-11-01 00:00:00

  • Thermal diffusion of radon in porous media.

    abstract::Based on the non-intersection model of cylindrical capillaries, the mean radius of the pores of some soils and building materials are estimated. In size, the above-mentioned radii are usually of the order of the free path of gas molecules at atmospheric pressure. A review of pore size distribution data also reveals th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006360

    authors: Minkin L

    更新日期:2003-01-01 00:00:00

  • Excess radiation absorbed doses from non-optimised radioiodine treatment of hyperthyroidism.

    abstract::Radioiodine therapy is often the method of choice for treatment of hyperthyroidism because it is considered safe, is relatively inexpensive, and is convenient for the patient and except for occasional hypothyroidism, almost without side effects. Even though radioiodine treatment has been performed for over 50 years, t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch013

    authors: Jönsson H,Mattsson S

    更新日期:2004-01-01 00:00:00

  • Radiation exposure from radioactive iodine 131I in and surrounding the patients' room.

    abstract::The purpose of this study is to measure the environmental radiation exposure in and surrounding the room of patients treated with (131)I. Absorbed dose rates were measured using thermoluminescence dosemeters, type TLD-200 (CaF(2):Dy), in a continuous monitoring programme. It is found that the estimated annual shallow ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp093

    authors: Abu-Khaled YS,Sandouqa AS,Haddadin IM

    更新日期:2009-07-01 00:00:00

  • Electric and magnetic fields generated by ac power lines: an application of advanced modelling tools in order to predict exposure levels.

    abstract::In view of expected legislation changes imposing more severe limits on magnetic flux density, proposals are made based on theory and measurement for adjustment of Fower placement with regard to efficiency, cost and cost-benefit. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006689

    authors: Manco D,Bruzzi L,Soloni A,Valbonetti D,Fabbri S,Violanti S

    更新日期:2001-01-01 00:00:00

  • Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital.

    abstract::The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch508

    authors: Compagnone G,Pagan L,Bergamini C

    更新日期:2005-01-01 00:00:00

  • Suggested diagnostic reference levels for paediatric X-ray examinations in India.

    abstract::Exposure of children to ionising radiation is considered to carry higher risk than that of adults; therefore a need to suggest diagnostic reference levels (DRLs) for the common paediatric diagnostic X-ray procedures was recognised for the X-ray machines meeting the requirements of the recently implemented Safety Code ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq458

    authors: Sonawane AU,Sunil Kumar JV,Singh M,Pradhan AS

    更新日期:2011-11-01 00:00:00