Experimental simulation of A-bomb gamma ray spectra: revisited.

Abstract:

:It has been reported recently that the A-bomb gamma ray spectra received by the colon of the average Japanese survivor of Hiroshima and Nagasaki may be experimentally simulated using a hospital-based Philips SL15 linear accelerator. The simulated A-bomb gamma radiation may be used in radiobiology experiments to determine, amongst other things, the biological effectiveness of the A-bomb gamma radiation. However, in that study, the electron beams from the linear accelerator were poorly defined and photon contamination was ignored. In the study reported here, a Varian Clinac 2100C linear accelerator has been used for the same purpose but with photon contamination included in better defined output electron beams. It is found that the A-bomb gamma radiation can still be matched to an acceptable degree (<10%). The cause of the slightly poorer fit was due mainly to the different ranges of energies available from the linear accelerators used. The absorbed dose received by model breasts was also estimated in this study for the same situations as in the previous study. The ratio of the breast to colon doses was found to be only (3.9 +/- 4.0)% low compared with the expected values of 1.17 and 1.16 for Hiroshima and Nagasaki, respectively. These results provide further confirmation of the acceptability of the simple cylindrically symmetrical body models employed in these studies to represent the average Japanese survivor.

journal_name

Radiat Prot Dosimetry

authors

Pattison JE,Payne LC,Hugtenburg RP,Beddoe AH,Charles MW

doi

10.1093/rpd/nch320

keywords:

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

175-80

issue

3

eissn

0144-8420

issn

1742-3406

pii

109/3/175

journal_volume

109

pub_type

杂志文章
  • SPECTROSCOPIC STUDY ON POLY(ACRYLIC ACID-CO-ACRYLAMIDE)-GRAFT-POLYANILINE AS A RADIATION DOSIMETER FOR ALPHA PARTICLES.

    abstract::Poly(acrylate-co-acrylamide) was a synthesis by chemical oxidation polymerization of an aqueous binary mixture of acrylate/acrylamide (1:1 mole ratio) using ammonium persulphate as an initiator at 70°C under the nitrogen atmosphere. The obtained copolymer was introduced for grafting with polyaniline. The grafting proc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx124

    authors: Abd El-Mageed HR,Abd El-Salam HM,Eissa MF

    更新日期:2018-03-01 00:00:00

  • Quality control and reliability of reported doses.

    abstract::Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch287

    authors: Stadtmann H,Figel M,Kamenopoulou V,Kluszczynski D,Roed H,Van Dijk J

    更新日期:2004-01-01 00:00:00

  • Internal dose assessment in radiation accidents.

    abstract::Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006250

    authors: Toohey RE

    更新日期:2003-01-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • QUANTITATIVE AND QUALITATIVE STUDY OF RADON CONTENT IN BULGARIAN MINERAL WATERS.

    abstract::This study presents the results of 222Rn in 24 sources of mineral water, 54 samples from different captured natural springs and drillings. 222Rn determination was performed by direct measurement using Alpha Guard with Aqua Kit. The results for the TDS, anions (F-, Cl-, SO42-), cations (Na+, Ca2+, Mg2+), pH and tempera...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy089

    authors: Kamenova-Totzeva RM,Totzev AV,Kotova RM,Ivanova-Teneva GR

    更新日期:2018-09-01 00:00:00

  • Patient dose in neonatal units.

    abstract::Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn237

    authors: Smans K,Struelens L,Smet M,Bosmans H,Vanhavere F

    更新日期:2008-01-01 00:00:00

  • A new position recording system for the partial-body counter at KIT.

    abstract::The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq416

    authors: Hegenbart L,Breustedt B

    更新日期:2011-03-01 00:00:00

  • Seasonal variation of indoor radon-222 levels in dwellings in Ramallah province and East Jerusalem suburbs, Palestine.

    abstract::This study presents the seasonal variations of indoor radon levels in dwellings located in the Ramallah province and East Jerusalem suburbs, Palestine. The measurements were performed during the summer and winter of the year 2006/2007 using CR-39 solid-state-nuclear-track detectors. The total number of investigated bu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr013

    authors: Leghrouz AA,Abu-Samreh MM,Shehadeh AK

    更新日期:2012-01-01 00:00:00

  • UNCERTAINTY EVALUATION FOR MULTIDETECTOR PASSIVE DOSEMETERS USING A TWO-STAGE MEASUREMENT MODEL AND THE MONTE CARLO METHOD.

    abstract::This paper proposes a method for evaluating the standard uncertainty in the measurements with passive personal dosemeters using a numerical method (Monte Carlo). The paper builds on a previous paper where a two-stage measurement model for passive dosemeters was proposed. This model follows the course of events during ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv493

    authors: van Dijk JW

    更新日期:2016-09-01 00:00:00

  • THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): AN INTRODUCTION TO THE DOCUMENTATION.

    abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx020

    authors: Napier BA

    更新日期:2017-11-01 00:00:00

  • SCOPING ANALYSIS OF MATERIAL ACTIVATION AT A BORON NEUTRON CAPTURE THERAPY FACILITY BASED ON THE Be(p,xn) REACTION WITH 30 MeV PROTONS.

    abstract::Material activation assessment of a proposed accelerator-based boron neutron capture therapy facility was performed using the FLUKA Monte Carlo code to quantify the magnitude of the problem in terms of the isotope inventories, induced activities, and residual dose rates. Two simplified operation scenarios were conside...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx289

    authors: Lai BL,Sheu RJ

    更新日期:2018-08-01 00:00:00

  • Microdosimetric evaluation of the neutron field for BNCT at Kyoto University reactor by using the PHITS code.

    abstract::In this study, microdosimetric energy distributions of secondary charged particles from the (10)B(n,α)(7)Li reaction in boron-neutron capture therapy (BNCT) field were calculated using the Particle and Heavy Ion Transport code System (PHITS). The PHITS simulation was performed to reproduce the geometrical set-up of an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq511

    authors: Baba H,Onizuka Y,Nakao M,Fukahori M,Sato T,Sakurai Y,Tanaka H,Endo S

    更新日期:2011-02-01 00:00:00

  • Contribution of indirect effects to clustered damage in DNA irradiated with protons.

    abstract::Protons are the dominant particles both in galactic cosmic rays and in solar particle events and, furthermore, proton irradiation becomes increasingly used in tumour treatment. It is believed that complex DNA damage is the determining factor for the consequent cellular response to radiation. DNA plasmid pBR322 was irr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv159

    authors: Pachnerová Brabcová K,Štěpán V,Karamitros M,Karabín M,Dostálek P,Incerti S,Davídková M,Sihver L

    更新日期:2015-09-01 00:00:00

  • Narrow beam dosimetry for high energy hadrons and electrons.

    abstract::Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10-400 GeV. The target organs considered were right eye, thyroid,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006556

    authors: Pelliccioni M,Silari M,Ulrici L

    更新日期:2001-01-01 00:00:00

  • A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.

    abstract::A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NR...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv478

    authors: Walbersloh J,Busch F

    更新日期:2016-09-01 00:00:00

  • VISUALIZATION OF THE DNA REPAIR PROCESS IN MAMMALIAN CELLS TRANSFECTED WITH EGFP-EXPRESSING PLASMID DNA AFTER EXPOSURE TO X-RAYS IN VITRO.

    abstract::To investigate the repair process of DNA damage induced by ionizing radiation in isolation from various types of cytoplasmic damage, we transfected X-irradiated enhanced green fluorescent protein (EGFP)-expressing plasmid DNA into non-irradiated mammalian cells using lipofectamine. The repair kinetics of the irradiate...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy241

    authors: Nakaue H,Obata Y,Kaminaga K,Akimitsu N,Yokoya A

    更新日期:2019-05-01 00:00:00

  • Variations of soil radon concentrations along Chite fault in Aizawl district, Mizoram, India.

    abstract::The present study concerns measurements of radon emissions from soil carried out during March to July 2013 at Chite fault in Aizawl district, Mizoram, India. In this study, continuous radon monitoring in soil was done by using LR-115 type II nuclear track detector (Kodak-Pathe, France make), and the exposed films were...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu221

    authors: Singh S,Jaishi H,Tiwari RP,Tiwari RC

    更新日期:2014-11-01 00:00:00

  • Medical management of radiation accidents: capabilities and deployment principles of the Bundeswehr Institute of Radiobiology.

    abstract::Radiation accidents are fortunately infrequent occurrences, but since their consequences can be very serious as in the Chernobyl and the Fukushima nuclear accidents, medical management of radiation accidents is of great importance. Besides several other tasks, medical management of radiation accidents is one of the ke...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs159

    authors: Dörr H,Meineke V

    更新日期:2012-10-01 00:00:00

  • Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    abstract::Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm455

    authors: Becková V,Malátová I

    更新日期:2008-01-01 00:00:00

  • COMMITTED EFFECTIVE DOSE DUE TO THE INTAKE OF 40K, 226Ra, 228Ra AND 228Th CONTAINED IN FOODS INCLUDED IN THE DIET OF THE RIO DE JANEIRO CITY POPULATION, BRAZIL.

    abstract::Annual effective dose due to the consumption of 40K, 226Ra, 228Ra and 228Th was estimated from high-resolution gamma spectrometry, food consumption data for the inhabitants of Rio de Janeiro City and dose coefficients published by the ICRP 119. A total of 31 samples of cereals, grains, vegetables, flours, liquid and p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx310

    authors: Lopes JM,Garcêz RWD,Filgueiras RA,Silva AX,Braz D

    更新日期:2018-10-01 00:00:00

  • CALCULATION OF CONVERSION COEFFICIENTS FOR VOXELIZED PHANTOMS FOR CRITICALITY ACCIDENT DOSIMETRY.

    abstract::In the event of a criticality accident, not only the maximal doses received by the victims must be determined but it is also crucial to evaluate the doses to the different organs. With a neutron component, morphology is a key parameter in the organ dose calculation. As the simulation tools can be time consuming to pro...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa123

    authors: Chevallier MA,Pontier JB,Morin H,Duluc M,Evo S,Letang E,Trompier F

    更新日期:2020-11-06 00:00:00

  • Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical X-ray imaging sensor.

    abstract::CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-dope...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci515

    authors: Kurata N,Kubota N,Takei Y,Nanto H

    更新日期:2006-01-01 00:00:00

  • PATIENT DOSE ASSESSMENT AFTER INTERVENTIONAL CARDIOLOGY PROCEDURES: A MULTI-CENTRIC APPROACH TO TRIGGER OPTIMISATION.

    abstract::As the number and complexity of fluoroscopically guided interventions increase, a serious effort has to be put on the optimisation of the X-ray dose delivered to the patient. In order to set up this optimisation process, the clinical practice for a given cardiology centre has to be analysed with relevant statistical p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncv525

    authors: Ryckx N,Goy JJ,Stauffer JC,Verdun FR

    更新日期:2016-06-01 00:00:00

  • Determination of natural radioactivity in drinking water in private dug wells in Akure, Southwestern Nigeria.

    abstract::Gamma spectrometry of well water was done to measure the activity concentrations of gamma-emitters 226Ra and 228Ra from 238U and 232Th series, respectively, and 40K in their waters. Measurements were done using high-purity (HPGe) co-axial detectors (Canberra, GC 2018-7500 ) coupled to Canberra Multichannel Analyser sy...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm429

    authors: Ajayi OS,Owolabi TP

    更新日期:2008-01-01 00:00:00

  • ESTE-DECISION SUPPORT SYSTEM FOR NUCLEAR AND RADIOLOGICAL ACCIDENTS.

    abstract::Described are functions, models and approaches of software tool Emergency Source Term code (ESTE), which is decision support system for crisis staff in case of nuclear or radiological accidents. The first task of ESTE in emergency situation at nuclear facility is to evaluate state of reactor core or state of fuel in s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz226

    authors: Fojcíková E,Lipták Ľ,Krpelanová M,Chylý M,Čarný P

    更新日期:2019-12-31 00:00:00

  • Discrimination between natural and other gamma ray sources from environmental gamma ray dose rate monitoring data.

    abstract::In this study, a method to discriminate between natural and other γ-ray sources from environmental γ-ray dose rate monitoring data was developed, and it was successfully applied to actual monitoring data around nuclear facilities. The environmental dose rate is generally monitored by NaI(Tl) detector systems in the lo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv265

    authors: Kumagai K,Ookubo H,Kimura H

    更新日期:2015-11-01 00:00:00

  • Protocols for dosimetry and patient reference levels.

    abstract::Doses in radiology should be as low as reasonably achievable. In order to compare practice in different centres it is necessary to compare patient doses. This can only be undertaken if dosimetry studies are similar. In order to facilitate comparisons, the DIMOND consortium developed a patient dosimetry protocol. Refer...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci715

    authors: Faulkner K

    更新日期:2005-01-01 00:00:00

  • Natural radioactivity levels of geothermal waters and their influence on soil and agricultural activities.

    abstract::All over the world geothermal sources are used for different purposes. The contents of these waters are important to understand positive/negative effects on human life. In this study, natural radioactivity concentrations of geothermal waters were investigated to evaluate the effect on soils and agricultural activities...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct220

    authors: Murat Saç M,Aydemir S,Içhedef M,Kumru MN,Bolca M,Ozen F

    更新日期:2014-01-01 00:00:00

  • Hp(3)/Φ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens.

    abstract::The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating Hp(3) for neutron realistic workplace spectra ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct246

    authors: Ferrari P,Gualdrini G,Tanner R,Fantuzzi E

    更新日期:2014-10-01 00:00:00

  • Methods and materials for the measurement of subjective and objective measurements of image quality.

    abstract::The evaluation of medical imaging systems may be performed using both subjective (e.g. high contrast limiting resolution, and low contrast detail detectability), and objective/physical (e.g. characteristic curve, signal-to-noise ratio, modulation transfer function, and Wiener spectra) indices of image quality. For the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006476

    authors: Marsh DM,Malone JF

    更新日期:2001-01-01 00:00:00