Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical X-ray imaging sensor.

Abstract:

:CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-doped CsBr (CsBr:Eu) exhibited intense optically stimulated luminescence (OSL). The peak wavelength of the OSL emission and stimulation spectra of CsBr:Eu phosphor ceramic sample were 450 and 690 nm, respectively. The dependence of OSL properties on the conditions of preparation of phosphor ceramic samples, such as Eu concentration, sintering temperature and sintering time, were studied. The optimum preparation conditions were also studied. It was found that the OSL intensity of CsBr:Eu phosphor ceramics fabricated under optimum preparation conditions is higher than that of commercially available imaging plates using BaFBr:Eu.

journal_name

Radiat Prot Dosimetry

authors

Kurata N,Kubota N,Takei Y,Nanto H

doi

10.1093/rpd/nci515

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

398-401

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

nci515

journal_volume

119

pub_type

杂志文章
  • MEASUREMENT OF THE POTENTIAL ALPHA ENERGY CONCENTRATION OF RADON PROGENY BY USING LIQUID SCINTILLATION COUNTING METHOD.

    abstract::For more accurate measurement of the potential alpha energy concentration (PAEC) of radon progeny by the liquid scintillation counting (LSC) method, its counting efficiency was studied in this work. A radon progeny standard source was used to provide different concentrations of radon progeny, and the progeny collected...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz069

    authors: Feng B,Tang Q,Zhang H,Chen B,Qiu S,Zhuo W

    更新日期:2019-10-01 00:00:00

  • IMPORTANCE OF ENGAGING IN DIALOGUE WITH THE POPULATION AFTER A NUCLEAR ACCIDENT.

    abstract::Human behaviour is primarily driven by perceptions and this is particularly important in the aftermath of a nuclear accident. One of the main lessons we can draw from the Chernobyl and Fukushima accidents is that once the acute phase of the accident is over, it is important to engage in dialogue with the affected popu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw320

    authors: Vanmarcke H

    更新日期:2017-04-01 00:00:00

  • Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetry.

    abstract::The performance of radiation dosemeters that are issued by approved individual monitoring services generally meet international standards, with typical results within a few tens of per cent of the reference value. Experienced dosimetry practitioners will understand the uncertainties and treat monitoring results with d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq298

    authors: Gilvin P,McWhan A

    更新日期:2011-03-01 00:00:00

  • Current status of radiological protection at nuclear power stations in Japan.

    abstract::The radiation dose to workers at nuclear power stations (NPSs) in Japan was drastically reduced between the late-1970s and the early-1990s by continuous dose-reduction programmes. The total collective dose of radiation workers in FY 2008 was 84.04 person Sv, while the average collective dose was 1.5 person Sv per reac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr185

    authors: Suzuki A,Hori S

    更新日期:2011-07-01 00:00:00

  • A dose index as a tool to estimate paediatric patient doses in digital projection radiography.

    abstract::Radiation exposure during childhood is estimated to have a lifetime risk up to seven times greater than exposures at adult age. Therefore, paediatric patient dose monitoring is a major concern in radiology. The aim of this study is to evaluate the validity of a dose index, displayed at the digital imaging and communic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr313

    authors: Garcia Castañon P,España Lopez ML,Fernandez Bedoya V,Bermudez Luna R,Rodriguez Martin G

    更新日期:2012-05-01 00:00:00

  • Analysis of the reliability of the local effect model for the use in carbon ion treatment planning systems.

    abstract::In radiotherapy with carbon ions, biological effects of treatments have to be predicted. For this purpose, one of the most used models is the local effect model (LEM) developed at the Gesellschaft für Schwerionenforschung (GSI), Germany. At the Istituto Nazionale di Fisica Nucleare, Italy, the reliability of the last ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq407

    authors: Russo G,Attili A,Bourhaleb F,Marchetto F,Peroni C,Schmitt E,Bertrand D

    更新日期:2011-02-01 00:00:00

  • CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II.

    abstract::Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx236

    authors: Harrison J,Moreno B,Van Hoey O,Mihailescu LC,Vanhavere F,Million M,Fomenko V,Akselrod M

    更新日期:2018-08-01 00:00:00

  • Achievements in workplace neutron dosimetry in the last decade: lessons learned from the EVIDOS project.

    abstract::The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm095

    authors: Tanner RJ,Bolognese-Milsztajn T,Boschung M,Coeck M,Curzio G,d'Errico F,Fiechtner A,Lillhök JE,Lacoste V,Lindborg L,Luszik-Bhadra M,Reginatto M,Schuhmacher H,Vanhavere F

    更新日期:2007-01-01 00:00:00

  • Energy dependence of W values of protons in water.

    abstract::The W values of protons in water vapour were measured for energies from 1 keV to 100 keV with uncertainties lower than 1%. To study the energy and phase dependence of W values, the W values of protons in water vapour and liquid water were calculated for energies from 0.1 keV and 10 MeV and then compared to the experim...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006798

    authors: Willems G,Back WY,Grosswendt B

    更新日期:2002-01-01 00:00:00

  • The impact of automatic wedge filter on photoneutron and photon spectra of an 18-MV photon beam.

    abstract::The effect of an automatic wedge filter on photon and photoneutron spectra of a medical linac was evaluated using the Monte Carlo method. The head of an Elekta SL75/25 was simulated using the MCNPX Monte Carlo code. The photon and photoneutron spectra for open and wedged beams were calculated at the isocentre with a s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp204

    authors: Ghavami SM,Mesbahi A,Mohammadi E

    更新日期:2010-02-01 00:00:00

  • INVESTIGATION OF THE INFLUENCE OF THE POSITION INSIDE A SMALL AIRCRAFT ON THE COSMIC-RADIATION-INDUCED DOSE.

    abstract::This article report the measurements on-board a small aircraft at the same altitude and around the same geographic coordinates. The measurements of Ambient Dose Equivalent Rate (H*(10)) were performed in several positions inside the aircraft, close and far from the pilot location and the discrimination between neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw384

    authors: Prado ACM,Pazianotto MT,Gonçalez OL,Dos Santos LR,Caldeira AD,Pereira HHC,Hubert G,Federico CA

    更新日期:2017-11-01 00:00:00

  • Methodology for Simple Spot Measurement of Equilibrium Equivalent Radon Concentration.

    abstract::Estimation of the effective inhalation dose of short half-life radon progeny requires the quantification of radon equilibrium equivalent activity concentrations (EEC, Ceq). The aim of the present study is to develop new methodology that focuses on spot measurements to determine EEC from single gross alpha counts and d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa176

    authors: Sakoda A,Ishimori Y,Kanzaki N,Tanaka H

    更新日期:2020-11-13 00:00:00

  • Neutron area survey instrument measurements in the EVIDOS project.

    abstract::Neutron survey instruments have been exposed at all the measurement locations used in the EVIDOS project. These results have an important impact in the interpretation of the results from the project, since operationally the survey instrument will be used for an initial assessment of and routine monitoring of the ambie...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm160

    authors: Tanner RJ,Bolognese-Milsztajn T,Boschung M,Coeck M,Curzio G,d'Errico F,Fiechtner A,Hager LG,Hussien M,Kyllönen JE,Lacoste V,Lindborg L,Luszik-Bhadra M,Molinos C,Reginatto M,Schuhmacher H,Vanhavere F

    更新日期:2007-01-01 00:00:00

  • New data on direct ion storage dosemeters.

    abstract::The DIS-1 dosemeter from the Finnish company RADOS is an innovative kind of passive electronic dosemeter for photon and beta radiation. This study examines the 'long-term' linear response behaviour, the calibration and readout accuracy with large samples of 'used' DIS-1 dosemeters especially in the low-dose region, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm240

    authors: Fuchs H,Stähler S,Dittmar M

    更新日期:2008-01-01 00:00:00

  • A combination study of indoor radon and in situ gamma spectrometry measurements in Greek dwellings.

    abstract::The aim of the present study was to investigate of a possible correlation between indoor radon and indoor gamma dose rates deduced by in situ gamma spectrometry measurements by using a portable HPGe detector. Indoor radon and high resolution in situ gamma spectrometry measurements were performed in 60 apartments in Th...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006154

    authors: Clouvas A,Xanthos S,Antonopoulos-Domis M

    更新日期:2003-01-01 00:00:00

  • Harmonization of individual dosimetry quality control within metrology system of a small country.

    abstract::A programme of harmonization of individual dosimetry quality control organized in the framework of a distributed metrology system is presented as seen from the experiences gained in Slovenia. As a part of the programme intercomparison of dosimetry services was organized and basic characteristics of dosimetry systems c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm198

    authors: Stuhec M,Zorko B,Vekić B,Miljanić S,Ban R,Basić B

    更新日期:2007-01-01 00:00:00

  • Indoor radon measurements in the dwellings of Punjab and Himachal Pradesh, India.

    abstract::The measurement of indoor radon concentrations were performed in the dwellings of the Punjab and Himachal Pradesh, India by using LR-115 type II Solid-State Nuclear Track Detectors in the bare mode. The annual average indoor radon concentrations in the dwellings are found to vary from 114 to 400 Bq m(-3) with an avera...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct041

    authors: Rani A,Singh S,Duggal V

    更新日期:2013-01-01 00:00:00

  • Maximum likelihood estimates of mean and variance of occupation radiation doses subjected to minimum detection levels.

    abstract::Data collection and its analysis in the field of nuclear safety is an important task in the sense that it powers the improvement of safety as well as reliability of the plant. Thus, occupational exposure data analysis is presented to measure the safety or reliability of radiation protection of a given facility. It als...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm483

    authors: Datta D,Singh S,Johnson BE,Kushwaha HS

    更新日期:2008-01-01 00:00:00

  • The TRADE experiment: shielding calculations for the building hosting the subcritical system.

    abstract::The TRADE project (TRiga Accelerator Driven Experiment), to be performed at the existing TRIGA reactor at ENEA Casaccia, has been proposed as a validation of the accelerator-driven system (ADS) concept. TRADE will be the first experiment in which the three main components of an ADS--the accelerator, spallation target ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci219

    authors: Burn KW,Carta M,Casalini L,Kadi Y,Monti S,Nava E,Palomba M,Petrovich C,Picardi L,Rubbia C,Troiani F

    更新日期:2005-01-01 00:00:00

  • Occurrence of natural radioactivity in public water supplies in Germany: (238)U, (234)U, (235)U, (228)RA, (226)RA, (222)RN, (210)PB, (210)PO and gross alpha activity concentrations.

    abstract::The Federal Office for Radiation Protection performed a representative survey on the radiological quality of drinking water in Germany. The aim of this study was to determine regional variations of natural radionuclide concentrations and to estimate radiation exposures caused by drinking water consumption. The study i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq139

    authors: Beyermann M,Bünger T,Schmidt K,Obrikat D

    更新日期:2010-09-01 00:00:00

  • Variations in radon concentration in groundwater of Kumaon Himalaya, India.

    abstract::The radon content in groundwater sources depends on the radium concentration in the rock of the aquifer. Radon was measured in water in many parts of the world, mostly for the risk assessment due to consumption of drinking water. The exposure to radon through drinking water is largely by inhalation and ingestion. Airb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs186

    authors: Bourai AA,Gusain GS,Rautela BS,Joshi V,Prasad G,Ramola RC

    更新日期:2012-11-01 00:00:00

  • Qualifying the use of RIS data for patient dose by comparison with DICOM header data.

    abstract::A system was developed in 2008 to calculate patient doses using Radiology Information System (RIS) data and presents these data as a patient dose audit. One of the issues with this system was the quality of user-entered data. It has been shown that Digital Imaging and Communication in Medicine (DICOM) header data can ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr352

    authors: Wilde R,Charnock P,McDonald S,Moores BM

    更新日期:2011-09-01 00:00:00

  • OCCUPATIONAL EXPOSURE CHARACTERISTICS AND FACTORS ASSOCIATED WITH RADIATION DOSES AMONG KOREAN RADIATION WORKERS.

    abstract::This study identified occupational factors associated with radiation exposure in Korea. Survey data of 16 037 workers from 2016 to 2017, including lifestyle factors and occupational characteristics, were combined with the National Dose Registry. Higher average annual doses were observed in groups exhibiting health ris...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa019

    authors: Kim J,Seo S,Lee DN,Park S,Im KJ,Park S,Jin YW

    更新日期:2020-07-07 00:00:00

  • Combined TL and 10B-alanine ESR dosimetry for BNCT.

    abstract::The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with (10)B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch110

    authors: Bartolotta A,D'Oca MC,Lo Giudice B,Brai M,Borio R,Forini N,Salvadori P,Manera S

    更新日期:2004-01-01 00:00:00

  • EXPOSURE ASSESSMENT OF PORTABLE WIRELESS DEVICES ABOVE 6 GHz.

    abstract::The emerging 5 G wireless devices working at frequencies above 6 GHz are expected to have antenna arrays formed by dipoles, slots, patches or their combination. At lower frequencies, the accepted criteria for exposure compliance is stated in terms of specific absorption rate. IEEE and ICNIRP are adopting epithelial or...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy177

    authors: Carrasco E,Colombi D,Foster KR,Ziskin M,Balzano Q

    更新日期:2019-06-01 00:00:00

  • ISO 4037:2019 VALIDATION OF RADIATION QUALITIES BY MEANS OF HALF-VALUE LAYER AND HP(10) DOSIMETRY.

    abstract::Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updated ISO 4037:2019 standard. As the ISO 4037 contains a somewhat vague d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz185

    authors: Bandalo V,Greiter MB,Brönner J,Hoedlmoser H

    更新日期:2019-12-31 00:00:00

  • Results of field trials using the NPL simulated reactor neutron field facility.

    abstract::The NPL simulated reactor neutron field facility provides neutron spectra similar to those found in the environs of UK gas-cooled reactors. Neutrons are generated by irradiating a thick lithium-alloy target with monoenergetic protons between 2.5 and 3.5 MeV (depending on the desired spectrum), and then moderated by a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm018

    authors: Taylor GC,Thomas DJ,Bennett A

    更新日期:2007-01-01 00:00:00

  • A review of the properties of the dosimetric systems and the quality assurance programmes of 48 dosimetric services in the European Union and Switzerland.

    abstract::This paper summarises the evaluation of the 1997 EURADOS questionnaire on dosimetric systems able to assess personal dose equivalent. In total, 56 approved dosimetric services in the European Union and Switzerland responded, together monitoring approximately 615,000 occupationally exposed persons. Of these services, 4...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006572

    authors: van Dijk JW,Bordy JM,Vanhavere F,Wernli C,Zamani-Valasiadou M

    更新日期:2001-01-01 00:00:00

  • BYSTANDER WI-38 CELLS MODULATE DNA DOUBLE-STRAND BREAK REPAIR IN MICROBEAM-TARGETED A549 CELLS THROUGH GAP JUNCTION INTERCELLULAR COMMUNICATION.

    abstract::Bi-directional signaling involved in radiation-induced bystander effect (RIBE) between irradiated carcinoma cells and their surrounding non-irradiated normal cells is relevant to radiation cancer therapy. Using the SPICE-NIRS microbeam, we delivered 500 protons to A549-GFP lung carcinoma cells, stably expressing H2B-G...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy249

    authors: Kobayashi A,Autsavapromporn N,Ahmad TAFT,Oikawa M,Homma-Takeda S,Furusawa Y,Wang J,Konishi T

    更新日期:2019-05-01 00:00:00

  • The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography.

    abstract::The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv114

    authors: Dyakov I,Stoinova V,Groudeva V,Vassileva J