Patient dosimetry in nuclear medicine.

Abstract:

:In diagnostic nuclear medicine, the biokinetics of the radiopharmaceutical (actually of the radionuclide) is determined for a number of representative patients. At therapy, it is essential to determine the patient's individual biokinetics of the radiopharmaceutical in order to calculate the absorbed doses to critical normal organs/tissues and to the target volume(s) with high accuracy. For the diagnostic situations, there is still a lack of quantitative determinations of the organ/tissue contents of radiopharmaceuticals and their variation with time. Planar gamma camera imaging using the conjugate view technique combined with a limited number of SPECT/CT images is the main method for such studies. In a similar way, PET/CT is used for 3D image-based internal dosimetry for PET substances. The transition from stylised reference phantoms to voxel phantoms will lead to improved dose estimates for diagnostic procedures. Examples of dose coefficients and effective doses for diagnostic substances are given. For the therapeutic situation, a pre-therapeutic low activity administration is used for quantitative measurements of organ/tissue distribution data by a gamma camera or a SPECT- or PET-unit. Together with CT and/or MR images this will be the base for individual dose calculations using Monte Carlo technique. Treatments based on administered activity should only be used if biological variations between patients are small or if a pre-therapeutic activity administration is impossible.

journal_name

Radiat Prot Dosimetry

authors

Mattsson S

doi

10.1093/rpd/ncv061

subject

Has Abstract

pub_date

2015-07-01 00:00:00

pages

416-23

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

ncv061

journal_volume

165

pub_type

杂志文章
  • PRE-ANTHROPIC AND PRESENT OUTDOOR GAMMA EQUIVALENT DOSE RATE OF THE HISTORIC CENTER OF ROME (ITALY).

    abstract::The outdoor gamma background of the historic center of Rome was studied by in situ measurements and average values of the outcropping geological formations. The survey resulted in two maps of dose equivalent rate, related to pre-anthropic and present conditions. Presently, the average of the dose equivalent rate from ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz247

    authors: Daniela G,Carloni S,Voltaggio M,Di Lisa GA

    更新日期:2019-12-31 00:00:00

  • A comparative review of charged particle microbeam facilities.

    abstract::At the low doses (and low dose rates) relevant to environmental and occupational radiation exposure (0-50 mSv), which are of practical concern for radiation protection, very few cells in the human organism experience more than one traversal by densely ionising particles in their lifetime, the intervals between the tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncl444

    authors: Gerardi S

    更新日期:2006-01-01 00:00:00

  • Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations.

    abstract::Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq104

    authors: Hoeschen C,Mattsson S,Cantone MC,Mikuz M,Lacasta C,Ebel G,Clinthorne N,Giussani A

    更新日期:2010-04-01 00:00:00

  • DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    abstract::The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx291

    authors: Forouzan F,Waker AJ

    更新日期:2018-08-01 00:00:00

  • An in vitro L-band electron paramagnetic resonance study of highly irradiated whole teeth.

    abstract::Regarding in vivo L-band dosimetry with human teeth, a number of preliminary experiments were carried out that were linked to the resonators response and the relative contribution of enamel to the EPR signal intensity of irradiated whole teeth. The sensitivity of the extended loop resonator varies in the antenna plane...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006036

    authors: Zdravkova M,Wieser A,El-Faramawy N,Gallez B,Debuyst R

    更新日期:2002-01-01 00:00:00

  • RADON EXHALATION FROM SOIL AND ITS DEPENDENCE FROM ENVIRONMENTAL PARAMETERS.

    abstract::An automatic measuring apparatus called exhalometer for measurement of the radon exhalation rate from soil is introduced. It consists of a pneumatic driven accumulation chamber with an open bottom, a PC-based control system, six Lucas cells for radon measurement and sensors for environmental parameters. It allows movi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx165

    authors: Yang J,Buchsteiner M,Salvamoser J,Irlinger J,Guo Q,Tschiersch J

    更新日期:2017-11-01 00:00:00

  • VALIDATION OF A BEAMNRC MONTE CARLO SIMULATION OF A BROAD BEAM DIAGNOSTIC X-RAY UNIT.

    abstract::A BEAMnrc Monte Carlo simulation of a diagnostic X-ray unit in a broad beam geometry intended for the derivation of effective linear attenuation coefficients was validated against measurements made on the X-ray unit on which the simulation was based. The validation process assessed the size of the beam, the first and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz032

    authors: Worrall M,Sutton DG

    更新日期:2019-12-31 00:00:00

  • Dose assessment for ingestion of a 330 kilobecquerel 60Co hot particle.

    abstract::On leaving the irradiated fuel bay at Pickering A nuclear power station, a worker triggered a whole body monitor alarm with activity in or on his head, and despite careful decontamination techniques he subsequently swallowed a hot particle. Over the next 3 d, the radioactivity was tracked through the body. It was then...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm256

    authors: Whillans DW,Chase WJ,Wolodarsky WH

    更新日期:2007-01-01 00:00:00

  • Narrow beam dosimetry for high energy hadrons and electrons.

    abstract::Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10-400 GeV. The target organs considered were right eye, thyroid,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006556

    authors: Pelliccioni M,Silari M,Ulrici L

    更新日期:2001-01-01 00:00:00

  • Skin dose measurements using radiochromic films, TLDS and ionisation chamber and comparison with Monte Carlo simulation.

    abstract::Estimation of the surface dose is very important for patients undergoing radiation therapy. The purpose of this study is to investigate the dose at the surface of a water phantom at a depth of 0.007 cm as recommended by the International Commission on Radiological Protection and International Commission on Radiation U...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct315

    authors: Alashrah S,Kandaiya S,Maalej N,El-Taher A

    更新日期:2014-12-01 00:00:00

  • Investigation of mean glandular dose versus compressed breast thickness relationship for mammography.

    abstract::The relationship between the mean glandular dose (MGD) and the compressed breast thickness (CBT) is commonly used for the presentation of mammographic dose survey results and could also be useful for the assessment of individual breast doses retrospectively in case of lack of necessary dosimetric instrumentation. The ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn140

    authors: Bor D,Tukel S,Olgar T,Toklu T,Aydin E,Akyol O

    更新日期:2008-01-01 00:00:00

  • Radiation dose to premature new-borns in the Belgian neonatal intensive care units.

    abstract::In the neonatal intensive care units (NICU), premature new-borns may be exposed to important doses. Because of their increased radiosensitivity and longer life expectancy, dose optimisation is of importance. The present study aimed at evaluating the dose of the most common radiographs in the Belgian NICU. Entrance sur...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct184

    authors: Dabin J,Struelens L,Vanhavere F

    更新日期:2014-01-01 00:00:00

  • CYTOGENETIC BIODOSIMETRY OF ACCIDENTAL EXPOSURES IN THE LONG TERMS AFTER IRRADIATION.

    abstract::The group of radiation victims who had received radiation injures similar to those of Chernobyl accident victims was evaluated in terms of retrospective cytogenetic biodosimetry in the long term period of from 17 y up to 50 y after irradiation. Based on the existing results of the long-term cytogenetic examination of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz040

    authors: Nugis VY,Kozlova MG,Nadejina NM,Galstyan IA,Nikitina VA,Khvostunov IK,Golub EV

    更新日期:2019-12-31 00:00:00

  • Dosimetric data and radiation risk analysis for new procedures in interventional cardiology.

    abstract::The purpose of this study was to evaluate radiation doses to the patients and operators during interventional cardiology procedures, with a particular focus on the transcatheter aortic valve implantation (TAVI). Patient doses for 5549 diagnostic and therapeutic procedures and 76 TAVI were examined, as well as occupati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq208

    authors: Signorotto P,del Vecchio A,Montorfano M,Maisano F,Giagnorio M,Bellanca R,Colombo A,Calandrino R

    更新日期:2010-12-01 00:00:00

  • ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE.

    abstract:OBJECTIVE:The aim of this study was to propose first established diagnostic reference levels (DRLs) in computed tomography (CT) for adults, based on volume-averaged CTDI and dose length product (DLP) metrics in Yazd Province. MATERIALS AND METHODS:Six multislice CT scanners located at diverse areas of Yazd Province an...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz279

    authors: Zamani H,Masjedi H,Omidi R,Hosein Zare M

    更新日期:2020-06-13 00:00:00

  • Filter, collimator and moderating material to achieve boron neutron capture enhanced fast neutron therapy.

    abstract::The combination of fast neutron therapy and boron neutron capture therapy is currently being studied as a possible treatment for some radio-resistant brain tumours. In an attempt to design a boron-enhanced fast neutron therapy beam for the Fermilab Fast Neutron Therapy Facility, the use of moderating material surround...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci256

    authors: Sweezy J,Hertel N,Lennox A

    更新日期:2005-01-01 00:00:00

  • Secondary neutron doses in proton therapy treatments of ocular melanoma and craniopharyngioma.

    abstract::Monte Carlo simulations were used to assess secondary neutron doses received by patients treated with proton therapy for ocular melanoma and craniopharyngioma. MCNPX calculations of out-of-field doses were done for ∼20 different organs considering realistic treatment plans and using computational phantoms representati...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct283

    authors: Farah J,Sayah R,Martinetti F,Donadille L,Lacoste V,Hérault J,Delacroix S,Nauraye C,Vabre I,Lee C,Bolch WE,Clairand I

    更新日期:2014-10-01 00:00:00

  • Dental CBCT equipment and performance issues.

    abstract::Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncs289

    authors: Horner K,Jacobs R,Schulze R

    更新日期:2013-02-01 00:00:00

  • Thermoluminescence properties of LiMgF3 doped with Ce, Er and Dy.

    abstract::The main dosimetric properties are reported of a new perovskite, LiMgF3, doped with Ce, Er and Dy impurities. An annealing temperature of 400 degrees C for one hour is necessary to erase any previous signal and to stabilise its sensitivity. A readout up to 450 degrees C gives the same result. The glow curve structure ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005858

    authors: Kitis G,Furetta C,Sanipoli C

    更新日期:2002-01-01 00:00:00

  • Calculation of the maximum allowed ambient dose rate outside CT rooms to quantitatively assess the structural shielding performance.

    abstract::The goal of this study was to develop a method to quantitatively assess the structural shielding performance of computed tomography (CT) rooms in Switzerland. The method was based on the comparison between calculated maximum allowed ambient dose rate (DR) and measured ambient DR in adjacent spaces. If the measured DR ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw131

    authors: Treier R,Landis R,Theiler T,Stritt N,Trueb PR,Baechler S

    更新日期:2017-04-25 00:00:00

  • Evaluation of occupational exposure to naturally occurring radioactive materials in the Iranian ceramics industry.

    abstract::Zircon contains small amounts of uranium, thorium and radium in its crystalline structure. The ceramic industry is one of the major consumers of zirconium compounds that are used as an ingredient at ∼10-20 % by weight in glaze. In this study, seven different ceramic factories have been investigated regarding the prese...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq441

    authors: Fathabadi N,Farahani MV,Amani S,Moradi M,Haddadi B

    更新日期:2011-06-01 00:00:00

  • Determination of committed effective doses to skin due to ²³⁸U, ²³²Th and ²²²Rn from the application of various Moroccan black soap (Saboun Beldi) samples by members of the general public.

    abstract::(238)U, (232)Th, (222)Rn and (220)Rn concentrations were measured inside various Moroccan black soap samples widely used by the Moroccan population in traditional baths (Hammans) by using both CR-39 and LR-115 type II solid state nuclear track detectors. The measured (238)U, (232)Th, (222)Rn and (220)Rn concentrations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq275

    authors: Misdaq MA,Outeqablit K

    更新日期:2010-12-01 00:00:00

  • Cellular signal transduction events as a function of linear energy transfer (LET).

    abstract::In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation, the number and size of pATM (S1981) and gamma-H2AX foci were compared in cultures of diploid human fibroblasts after exposure to charged particles of varying species, energ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm086

    authors: Fürweger C,Hajek M,Vana N,Kodym R,Okayasu R

    更新日期:2007-01-01 00:00:00

  • Dose distribution in the Russian Segment of the International Space Station.

    abstract::Absorbed dose and average linear energy transfer (LET) were assessed by means of (7)LiF:Mg,Ti (TLD-700) thermoluminescent (TL) detectors for different panels on-board the Russian Segment of the International Space Station in the timeframe between March and November 2002 (233 d). A technique is presented to correct the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci566

    authors: Hajek M,Berger T,Fugger M,Fürstner M,Vana N,Akatov Y,Shurshakov V,Arkhangelsky V

    更新日期:2006-01-01 00:00:00

  • Individual monitoring in mixed neutron/photon fields using a single silicon detector.

    abstract::A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 Me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005962

    authors: Luszik-Bhadra M

    更新日期:2002-01-01 00:00:00

  • Nuclear theory for high-energy nuclear reactions of biomedical relevance.

    abstract::A full description of all possible nuclear reactions that take place in a macroscopic device can only be accomplished with a nuclear model code in combination with key experimental data. To address this issue, the authors demonstrate some of the capabilities of TALYS, a nuclear reaction program which simulates nuclear...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm008

    authors: Koning AJ,Duijvestijn MC

    更新日期:2007-01-01 00:00:00

  • Design of a multi-element TEPC for neutron monitoring.

    abstract::Tissue-equivalent proportional counters (TEPCs) have long been considered suitable candidate instruments for more accurate neutron monitors in nuclear power plants. It has also been recognised that the production of truly light-weight devices based on TEPCs requires further effort directed towards increasing their sen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq538

    authors: Waker AJ,Aslam,Lori J

    更新日期:2011-02-01 00:00:00

  • Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle.

    abstract::Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiose...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl545

    authors: Krol M,Lankoff A,Buraczewska I,Derezinska E,Wojcik A

    更新日期:2007-01-01 00:00:00

  • Deformation luminescence produced during application and release of pressure on to gamma-irradiated CaF2:RE crystals.

    abstract::Calcium fluoride CaF2 is an interesting host lattice for rare earth (RE) activators. CaF2 crystals doped with different concentrations of Dy, Ce, Er and Gd have been grown by the Bridgman technique and their deformation luminescence (DL) induced by room temperature gamma irradiation has been recorded. When a uniaxial ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci606

    authors: Kher RS,Brahme N,Banerjee M,Dhoble SJ,Khokhar MS

    更新日期:2006-01-01 00:00:00

  • COMPARISON OF MCNP AND VISIPLAN DOSE-FIELD CALCULATIONS FOR MULTILAYER SHIELDING.

    abstract::An important factor in calculation of quantities describing the radiation situation is the selection of a calculation code. In this article, the radiation situation for selected geometries with multilayer shields was judged. Calculations were carried out using deterministic code VISIPLAN and stochastic code MCNP5. Int...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz224

    authors: Bednár D,Lištjak M,Slimák A,Nečas V

    更新日期:2019-12-31 00:00:00