Dosimetric data and radiation risk analysis for new procedures in interventional cardiology.

Abstract:

:The purpose of this study was to evaluate radiation doses to the patients and operators during interventional cardiology procedures, with a particular focus on the transcatheter aortic valve implantation (TAVI). Patient doses for 5549 diagnostic and therapeutic procedures and 76 TAVI were examined, as well as occupational doses to Cardiology Department operators. The average patient dose for TAVI was double that of PTCA and six times higher than a simple CA; statistically significant differences were shown in the average patient dose for both transfemoral and transapical access; the measurements show a corresponding increase in the average occupational dose for the cardiologist. Interventional cardiology could increase the collective dose and occupationally exposed worker doses; this increase could be significant if the use of certain procedures is extended to younger people; particular attention in the choice of procedure, optimisation and staff education and organisation is therefore suggested.

journal_name

Radiat Prot Dosimetry

authors

Signorotto P,del Vecchio A,Montorfano M,Maisano F,Giagnorio M,Bellanca R,Colombo A,Calandrino R

doi

10.1093/rpd/ncq208

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

201-8

issue

2-4

eissn

0144-8420

issn

1742-3406

pii

ncq208

journal_volume

142

pub_type

杂志文章
  • Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation.

    abstract::In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiograp...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr355

    authors: Paulo G,Santos J,Moreira A,Figueiredo F

    更新日期:2011-09-01 00:00:00

  • Occupational radiation exposure to norms in a gold mine.

    abstract::Preliminary studies have been conducted into the occupational radiation exposure to NORMS from surface and underground mining operations in a gold mine in the Ashanti Region of Ghana. A brief description of the methods and instrumentation is presented. The annual effective dose has been estimated to be 0.26 +/- 0.11 m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci300

    authors: Darko EO,Tetteh GK,Akaho EH

    更新日期:2005-01-01 00:00:00

  • Sub-slab depressurisation systems used in the Czech Republic and verification of their efficiency.

    abstract::Design principles for sub-slab depressurisation systems recently used in the Czech Republic for remediating existing buildings are described. Results of an efficiency analysis performed on the basis of data from >60 single-family houses are presented. It was found out that the efficiency varies between 70 and 98 %, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu219

    authors: Jiránek M

    更新日期:2014-11-01 00:00:00

  • SIMULATION OF OSL AND TLD DOSEMETER RESPONSE FOR THE DEVELOPMENT OF NEW EXTREMITY DOSEMETERS.

    abstract::The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry developed by Dosimetrics. In the design process for the new eye lens d...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy299

    authors: Hoedlmoser H,Brönner J,Bandalo V,Wahl F,Greiter MB

    更新日期:2019-12-23 00:00:00

  • NATURAL RADIATION EXPOSURE TO THE PUBLIC IN MINING AND ORE BEARING REGIONS OF CAMEROON.

    abstract::Within the framework of a joint research project on natural radiation exposure and its health effects in Cameroon from 2014 to 2017, the Institute of Geological and Mining Research and the Hirosaki University worked together to carry out natural radiation survey in mining and ore bearing regions of Cameroon. Air kerma...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz176

    authors: Tokonami S,Hosoda M,Joseph Emmanuel NNI,Akata N,Flore TSY,Modibo OB,Samuel BG,Didier TSS

    更新日期:2019-10-01 00:00:00

  • Simulation of DNA damage after proton and low LET irradiation.

    abstract::A module for proton track structure simulation in liquid water was implemented in the biophysical model PARTRAC. Simulated tracks of energy deposition events from the radiation under investigation were superimposed on a higher-order DNA target model describing the whole genome inside a human cell. The parameters contr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006848

    authors: Friedland W,Bernhardt P,Jacob P,Paretzke HG,Dingfelder M

    更新日期:2002-01-01 00:00:00

  • Neutron spectrometry in a PET cyclotron with a Bonner sphere system.

    abstract::Positron emission tomography (PET) is a non-invasive medical imaging technique normally used for diagnostic purposes to determine the location and concentration of physiologically active compounds in a human body. An unshielded cyclotron is used for PET at the Clinica Universitaria de Navarra to produce short-lived po...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm077

    authors: Fernández F,Amgarou K,Domingo C,García MJ,Quincoces G,Martí-Climent JM,Méndez R,Barquero R

    更新日期:2007-01-01 00:00:00

  • INVESTIGATION OF EXTERNAL RADIATION DOSES DURING RESIDENTS' TEMPORAL STAY TO NAMIE TOWN, FUKUSHIMA PREFECTURE.

    abstract::Namie Town in Fukushima Prefecture, the majority of which was an evacuation area as a result of the effects of the Fukushima Daiichi Nuclear Power Plant accident, carried out a 'temporal stay' in September 2016 so that residents could check their houses. Therefore, in cooperation with the town authorities, the authors...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz107

    authors: Tsujiguchi T,Shiroma Y,Suzuki T,Tamakuma Y,Yamaguchi M,Iwaoka K,Hosoda M,Tokonami S,Kashiwakura I

    更新日期:2019-10-01 00:00:00

  • Comparison of different methods for shielding design in computed tomography.

    abstract::The purpose of this work is to compare different methods for shielding calculation in computed tomography (CT). The BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) and NCRP (National Council on Radiation Protection) method were used for shielding thickness calculation. Sca...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr287

    authors: Ciraj-Bjelac O,Arandjic D,Kosutic D

    更新日期:2011-09-01 00:00:00

  • The measurements of thoron, radon and their decay products thanks to Pinocchio, Tengu and Trolls.

    abstract::In the present paper, the long noses of Pinocchio, Tengu and Trolls are used to measure, respectively, radon, thoron, and their decay products both by track-etch detectors and by Geiger-Müller (G-M) counters. Just recently, four new passive samplers (termed quatrefoil) have been developed which greatly simplify the de...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq248

    authors: Tommasino L,Tokonami S,Tommasino PM

    更新日期:2010-10-01 00:00:00

  • Can default ICRP f1 values be applied to determine radiation dose from the intake of diet-incorporated thorium?

    abstract::Data on the daily urinary excretion of thorium (Th) was obtained from 15 non-exposed adult German subjects. A radiochemical neutron activation analysis method was developed and standardised especially for this purpose. The daily urinary excretion of 232Th was found to be in the range 1.9-14.9 microBq d(-1) with a mean...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch482

    authors: Höllriegl V,Li WB,Oeh U,Röhmuss M,Roth P

    更新日期:2005-01-01 00:00:00

  • Neutron and photon fields in the BNCT room with closed beam shutters.

    abstract::The epithermal neutron beam at the LVR-15 reactor was designed for the Boron Neutron Capture Therapy (BNCT) of cancers, but it has also been used for material testing. In the case where the beam is closed with two designed shutters, there is still an indispensable background in the irradiation room, which limits the m...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci112

    authors: Marek M,Viererbl L

    更新日期:2005-01-01 00:00:00

  • Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

    abstract::The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The I...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci627

    authors: Kim JL,Lee JI,Ji YH,Kim BH,Kim JS,Chang SY

    更新日期:2006-01-01 00:00:00

  • ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

    abstract::The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci702

    authors: Vano E,Faulkner K

    更新日期:2005-01-01 00:00:00

  • Radiation exposure received by the medical radiation workers in Lithuania at the Institute of Oncology, Vilnius University, 2004-2011.

    abstract::The occupational radiation exposure of medical radiation workers at the Institute of Oncology, Vilnius University (IOVU) was analysed. Quartile dose measurements were collected and routinely analysed for a period of 8 y from 1 January 2004 to 31 December 2011. A total of 193 medical radiation workers were monitored, c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct111

    authors: Samerdokiene V,Atkocius V,Ofomala R

    更新日期:2013-11-01 00:00:00

  • MEASUREMENT OF THE POTENTIAL ALPHA ENERGY CONCENTRATION OF RADON PROGENY BY USING LIQUID SCINTILLATION COUNTING METHOD.

    abstract::For more accurate measurement of the potential alpha energy concentration (PAEC) of radon progeny by the liquid scintillation counting (LSC) method, its counting efficiency was studied in this work. A radon progeny standard source was used to provide different concentrations of radon progeny, and the progeny collected...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncz069

    authors: Feng B,Tang Q,Zhang H,Chen B,Qiu S,Zhuo W

    更新日期:2019-10-01 00:00:00

  • KINETIC SIMULATIONS OF THE THERMOLUMINESCENCE CHARACTERISTICS OF LiF:Mg, Ti INCORPORATING LOCALISED AND DELOCALISED RECOMBINATION.

    abstract::Kinetic simulations of the thermoluminescence characteristics of LiF:Mg, Ti are reviewed in the framework of conduction band/valence band models. Delocalised recombination models have been mainly applied to the simulation of glow peak shapes, although comparison with experimental data has proven difficult if not impos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa209

    authors: Eliyahu I,Oster L

    更新日期:2021-01-13 00:00:00

  • A solid state microdosimeter based on a monolithic silicon telescope.

    abstract::A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl468

    authors: Agosteo S,Colautti P,Fazzi A,Moro D,Pola A

    更新日期:2006-01-01 00:00:00

  • The influence of caesium-137 distribution in Poland's north-eastern ecosystem on effective dose 10 years after the Chernobyl disaster.

    abstract::A comparison is presented of particular methods of exposure in the first year after the Chernobyl disaster and ten years later. This comparison shows that the population exposure due to the presence of radiocaesium in the environment results from the presence of caesium contained in the soil, which provides 68% of the...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006725

    authors: Zalewski M,Kapala J,Tomczak M

    更新日期:2002-01-01 00:00:00

  • Generation of a head phantom according to the 95th percentile Chinese population data for evaluating the specific absorption rate by wireless communication devices.

    abstract::A Chinese head phantom (CHP) is constructed for evaluating the specific absorption rate (SAR) by the wireless transceivers. The dimensions of the head phantom are within 4 % difference compared with the 95th percentile data from the China's standard. The shell's thickness and the configuration of the pinna are the sam...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct254

    authors: Ma Y,Wang Y,Shao Q,Li C,Wu T

    更新日期:2014-03-01 00:00:00

  • Childhood leukaemia near British nuclear installations: methodological issues and recent results.

    abstract::In 2008, the German Childhood Cancer Registry published the results of the Kinderkrebs in der Umgebung von Kernkraftwerken (KiKK) study of childhood cancer and leukaemia around German nuclear power stations. The positive findings appeared to conflict with the results of a recent British analysis carried out by the Com...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncn254

    authors: Bithell JF,Keegan TJ,Kroll ME,Murphy MF,Vincent TJ

    更新日期:2008-01-01 00:00:00

  • Specific features of the influence of high-energy electron beams on the luminescent properties of undoped and Nb, Fe-doped Al₂O₃ crystals.

    abstract::The influence of 10 MeV high-current electron beams accelerated by the M-30 microtron on the luminescent properties of the α-Al₂O₃, Al₂O₃:Nb and Al₂O₃:Fe crystals has been studied. The effect of the long-term phosphorescence at room temperature has been found that can be used to monitor electron and gamma accelerator ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu213

    authors: Maslyuk VT,Megela IG,Okunieva TO,Pekar JM,Pekar VJ

    更新日期:2014-11-01 00:00:00

  • AEROSOL SIZE DISTRIBUTION IN URANIUM PROCESSING FACILITY FOR APPLICATION IN THE ASSESSMENT OF INTERNAL EXPOSURE.

    abstract::In circumstances of inhalation exposure the radiotoxicity of radionuclide depends on the fractional deposition of inhaled activity, which is governed by the aerodynamic characteristics of the particles. Although International Commission on Radiological Protection (ICRP) provides default size distribution parameters fo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx231

    authors: Shailesh M,Das T,Prabhat M,Kolekar RV,Gopalakrishnan RK

    更新日期:2018-04-01 00:00:00

  • Response of the Nrf2 protection system in human monocytic cells after ionising irradiation.

    abstract::In response to reactive oxygen species (ROS) or electrophiles, the transcription factor nuclear factor-erythroid 2 (NF-E2)-related factor 2 (Nrf2) rapidly translocates into the nucleus and induces the expression of various antioxidant genes, such as heme oxygenase-1 (HO-1). Low linear energy transfer (LET) ionising ra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs201

    authors: Yoshino H,Kiminarita T,Matsushita Y,Kashiwakura I

    更新日期:2012-11-01 00:00:00

  • Patient dose in neonatal units.

    abstract::Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn237

    authors: Smans K,Struelens L,Smet M,Bosmans H,Vanhavere F

    更新日期:2008-01-01 00:00:00

  • Individual monitoring in mixed neutron/photon fields using a single silicon detector.

    abstract::A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 Me...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005962

    authors: Luszik-Bhadra M

    更新日期:2002-01-01 00:00:00

  • Radiation Protection Studies for Medical Particle Accelerators using Fluka Monte Carlo Code.

    abstract::Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw302

    authors: Infantino A,Cicoria G,Lucconi G,Pancaldi D,Vichi S,Zagni F,Mostacci D,Marengo M

    更新日期:2017-04-01 00:00:00

  • Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy.

    abstract::On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of (131)I. Radiation doses for the designated caregivers were ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl084

    authors: Marriott CJ,Webber CE,Gulenchyn KY

    更新日期:2007-01-01 00:00:00

  • Inter-laboratory test program (PTI) in 'neutron dosimetry'.

    abstract::The Laboratory of External Dosimetry Studies and Researches (LRDE), associated laboratory to the Bureau National de Métrologie, is strongly involved in the reference establishment and calibration of instruments in neutron radiation fields provided by 241Am-Be, 252Cf and (252Cf + D2O)/Cd sources. In 1997, on the reques...

    journal_title:Radiation protection dosimetry

    pub_type: 指南,杂志文章,多中心研究

    doi:10.1093/rpd/nch193

    authors: Van-Ryckeghem L,Pelcot G,Suder F,Bureau National de Métrologie.

    更新日期:2004-01-01 00:00:00

  • Naturally occurring radioactive materials (NORM) in ashes from a fuel-oil power plant in Cienfuegos, Cuba, and the associated radiation hazards.

    abstract::The radioactivity of NORM was measured in ashes collected from a fuel-oil power plant in Cienfuegos, Cuba, using an HPGe gamma-ray spectrometer. The (226)Ra, (210)Pb, (40)K, (232)Th and (238)U activity concentrations reached 240, 77, 59, 70 and 15 Bq kg(-1), respectively. The potential radiological hazard of these res...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct237

    authors: Alonso-Hernández CM,Bernal-Castillo J,Morera-Gómez Y,Guillen-Arruebarrena A,Cartas-Aguila HA,Acosta-Milián R

    更新日期:2014-03-01 00:00:00